The evaluation of measurement system for high power tests (대전력시험에 사용되는 측정시스템의 평가)

  • Lee, Dong-Jun;Jung, Heung-So;Kim, Won-Man;Kim, Sun-Koo;Ra, Dae-Ryeol;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.286-288
    • /
    • 2002
  • The rapid development of measurement systems for high power tests makes it possible to measure signals as well as analyze with the help of computer. Also, methods to evaluate such measurement systems are required recently. Uncertainty has been regarding as the most important factor in evaluating the measurement systems. Because of the character of the measurement systems for high power tests. the uncertainty shall be evaluated by each component. If the uncertainty evaluated by each component, it is convenient to evaluate total uncertainty of the measurement systems according to each component setting's combination. In this paper each component of high current measurement system of high power testing Dept. II in Korea Electrotechnology Research Institute is evaluated except sensors such as shunts and CTs. The total uncertainty of the measurement systems can be determined by that of each component including uncertainty of sensors.

  • PDF

Design of a MEMS sensor array for dam subsidence monitoring based on dual-sensor cooperative measurements

  • Tao, Tao;Yang, Jianfeng;Wei, Wei;Wozniak, Marcin;Scherer, Rafal;Damasevicius, Robertas
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.15 no.10
    • /
    • pp.3554-3570
    • /
    • 2021
  • With the rapid development of the Chinese water project, the safety monitoring of dams is urgently needed. Many drawbacks exist in dams, such as high monitoring costs, a limited equipment service life, long-term monitoring difficulties. MEMS sensors have the advantages of low cost, high precision, easy installation, and simplicity, so they have broad application prospects in engineering measurements. This paper designs intelligent monitoring based on the collaborative measurement of dual MEMS sensors. The system first determines the endpoint coordinates of the sensor array by the coordinate transformation relationship in the monitoring system and then obtains the dam settlement according to the endpoint coordinates. Next, this paper proposes a dual-MEMS sensor collaborative measurement algorithm that builds a mathematical model of the dual-sensor measurement. The monitoring system realizes mutual compensation between sensor measurement data by calculating the motion constraint matrix between the two sensors. Compared with the single-sensor measurement, the dual-sensor measurement algorithm is more accurate and can improve the reliability of long-term monitoring data. Finally, the experimental results show that the dam subsidence monitoring system proposed in this paper fully meets the engineering monitoring accuracy needs, and the dual-sensor collaborative measurement system is more stable than the single-sensor monitoring system.

Experimental Study on the Characteristics of Rapid Chilled Converter Slag by Watering

  • Lee, Keun-Jae;Yoo, Seung-Yeup;Koo, Ja-Sul;Cho, Bong-Suk;Lee, Hoon-Ha
    • International Journal of Concrete Structures and Materials
    • /
    • v.5 no.2
    • /
    • pp.133-137
    • /
    • 2011
  • In this study, a physical and chemical properties analysis was conducted for PCSP to evaluate properties of its materials and, for comparison purpose, was also conducted for CSP. The result of experiment confirmed improvement of iron recovery rate due to introduction of rapid water-cooling equipment and greater density of exterior and interior structure through SEM observation and porosity measurement. Also, SEM, XRD and DSC-TGA analysis showed that content of f-CaO in PCSP was minuscule so it was decided that problems of material stability including f-CaO-caused bulging failure, which has been problematic, can be solved.

Evaluation of Dynamic Behavior of Rail Joints on Personal Rapid Transit Track (소형무인경전철(PRT)궤도 레일이음매의 동적거동 분석)

  • Choi, Jung-Youl;Kim, Jun-Hyung
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.5
    • /
    • pp.89-94
    • /
    • 2016
  • The objective of this study was to estimate the dynamic behavior of a personal rapid transit(PRT) track system using a rail of rectangular tube section and a rail joint of sliding type, and to compare the results with the normal rail and rail joint of a PRT track system by performing field measurements using actual vehicles running along the service lines. The measured vertical displacement of rail and sleeper, and vertical acceleration of rail for the normal rail and rail joint section were found to be similar, and the rail joint of sliding type satisfied the design specifications of the track impact factor for a conventional railway track. The experimental results showed that the overall dynamic response of the rail joint were found to be similar to or less than that of the normal rail, therefore the rail joint of sliding type for PRT track system was sufficient to ensure a stability and safety of PRT track system.

Electrochemistry and Leaching Kinetics of Gold-Silver Alloys in Cyanide Solutions

  • Guan, Y.Charles;Sun, Xiaowei;Han, Kenneth N.
    • Resources Recycling
    • /
    • v.10 no.1
    • /
    • pp.42-48
    • /
    • 2001
  • The dissolution behavior of gold and silver from gold-silver alloys in aerated cyanide solutions has been investigated by an electrochemical means as well as a direct measurement of gold and silver ions reported in the bulk solution as a function of time using rotating disc electrodes. The variables studied included oxygen partial pressure, rotating speed of the disc, concentration of cyanide, temperature and composition of the allyos. The dissolution potential and the rate of dissolution were obtained in view of the anodic and cathodic current-potential relationships. The results were discussed in terms of the mixed potential theory. The results showed that the dissolution rate of gold and silver from the alloys was controlled partially by chemical reaction. but largely by transport of either oxygen or cyanide, depending on their relative concentration under the experimental conditions employed in this study.

  • PDF

A System for Rapid Design and Manufacturing of Custom-Tailored Shoes

  • Park, Sang-Kun;Lee, Kun-Woo;Kim, Jong-Won;Park, Jong-Woo
    • Journal of Mechanical Science and Technology
    • /
    • v.14 no.6
    • /
    • pp.675-689
    • /
    • 2000
  • Rapid design and production techniques are indispensable for the custom-made production systems. For manufacturing custom-made shoes, the shoelast should be designed rapidly from the individual foot model. In this paper, we develop an integrated system for rapid design and manufacturing of custom-tailored shoes. The foot shape measurement sub-system allows scanning a standard shoelast and an individual foot and then extracts the three-dimensional crosssectional data of the shoelast and the human foot shape from the captured image data. The shoelast design sub-system uses the scanned data to design new customized shoelast curves or surfaces with the heeling and mixing algorithms built in this system. The pattern design subsystem provides a method, which transforms a shoe-upper surface designed by a stylist into a flat-pattern that can be manufactured. We also export the surface model to an NC machine to manufacture the physical shoelast model.

  • PDF

Temperature Measurement in Concentric Diffusion Flames by Rapid Insertion Technique (급속 삽입법에 의한 화염 내부 온도 분포 측정)

  • Lee, Gyo-Woo;Chung, Young-Rok;Jurng, Jong-Soo
    • Journal of the Korean Society of Combustion
    • /
    • v.4 no.2
    • /
    • pp.75-83
    • /
    • 1999
  • The effect of temperature distributions on soot volume fraction in double-concentric diffusion flames have been investigated experimentally. Using fine thermocouple wires and a rapid insertion mechanism, we have measured temperature without the effect of soot particles attached to the thermocouple junction, which can lower the temperature signal about 100 K by increasing the heat loss from the junction by radiation. The temperature at the flame axis is higher in the double-concentric diffusion flames than in normal co-flow diffusion flames because of the inverse diffusion flame. However, it is almost the same as that at the periphery of normal flames, on which the inverse flame does not have an effect. Thus, the lower soot concentration found in the double-concentric diffusion flame can be explained by the effect of nitrogen diffusion from the central air jet.

  • PDF

Biosensors and their Applications in Food Safety: A Review

  • Yasmin, Jannat;Ahmed, Mohammed Raju;Cho, Byoung-Kwan
    • Journal of Biosystems Engineering
    • /
    • v.41 no.3
    • /
    • pp.240-254
    • /
    • 2016
  • Background: Foodborne pathogens are a growing concern with respect to human illnesses and death. There is an increasing demand for improvements in global food safety. However, it is a challenge to detect and identify these harmful organisms in a rapid, responsive, suitable, and effective way. Results: Rapid developments in biosensor designs have contributed to the detection of foodborne pathogens and other microorganisms. Biosensors can automate this process and have the potential to enable fast analyses that are cost and time-effective. Various biosensor techniques are available that can identify foodborne pathogens and other health hazards. Conclusions: In this review, biosensor technology is briefly discussed, followed by a summary of foodborne pathogen detection using various transduction systems that exhibit specificity for particular foodborne pathogens. In addition, the recent application of biosensor technology to detect pesticides and heavy metals is briefly addressed.

Wireless Bio-signal Monitoring System (무선 생체신호 모니터링 시스템)

  • Kim, Do-Kyoung;Lee, In-Kwang;Cha, Eun-Jong;Kim, Kyung-Ah
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2055-2056
    • /
    • 2011
  • As rapid aging and high economic level, people are interested in their wellness. And it needs to examine the condition of their health constantly. Proposed device can measure bio-signal by connecting several measurement modules such as spirometric module, blood glucose measurement module, uro-flow measurement module and temperature measurement module. These modules can be chosen as occasion demands. In addition, developed user program enables patients to monitor bio-signal at their own place via the personal computer.

  • PDF

Nonlinearity-Compensation Extended Kalman Filter for Handling Unexpected Measurement Uncertainty in Process Tomography

  • Kim, Jeong-Hoon;Ijaz, Umer Zeeshan;Kim, Bong-Seok;Kim, Min-Chan;Kim, Sin;Kim, Kyung-Youn
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1897-1902
    • /
    • 2005
  • The objective of this paper is to estimate the concentration distribution in flow field inside the pipeline based on electrical impedance tomography. Special emphasis is given to the development of dynamic imaging technique for two-phase field undergoing a rapid transient change. Nonlinearity-compensation extended Kalman filter is employed to cope with unexpected measurement uncertainty. The nonlinearity-compensation extended Kalman filter compensates for the influence of measurement uncertainty and solves the instability of extended Kalman filter. Extensive computer simulations are carried out to show that nonlinearity-compensation extended Kalman filter has enhanced estimation performance especially in the unexpected measurement environment.

  • PDF