• Title/Summary/Keyword: Rapid heating

Search Result 392, Processing Time 0.038 seconds

Sterilization of Gochujang Sauce with Continuous Ohmic Hea (연속 옴가열 장치를 이용한 고추장 소스의 살균)

  • Choi, Jun-Bong;Cho, Won-Il;Jung, Jung-Yoon;Chung, Myong-Soo
    • Korean Journal of Food Science and Technology
    • /
    • v.47 no.4
    • /
    • pp.474-479
    • /
    • 2015
  • In this study, five different Gochujang (a traditional Korean sauce prepared using fermented red pepper paste) sauces were heated at $100^{\circ}C$ for 5 min using a continuous ohmic heating system. Ohmic heating yielded greater reduction in microbial counts (90-95% reduction) than did conventional heating (65-75% reduction). The sterilization effect of the continuous ohmic heater increased with increasing sample flow rate and decreasing Reynolds number inside the pipe. Low-viscosity samples had higher electrical conductivity and were better suited for ohmic heating than were high-viscosity samples. The color and texture were also satisfactorily maintained after ohmic heating. Compared with conventional heating, ohmic heating provided rapid and uniform heating, which is more suitable for aseptic thermal processing of viscous foods.

Studies on the Rapid Plasma Reagin(RPR) Card Test for the Diagnosis of Syphilis (매독진단(梅毒診斷)을 위(爲)한 신속(迅速)한 혈장항체검사법(血漿抗體檢査法)에 관(關)한 연구(硏究))

  • Kim, Joo-Deuk;Lew, Joon;Kim, Hyun-Joo
    • The Journal of the Korean Society for Microbiology
    • /
    • v.3 no.1
    • /
    • pp.15-23
    • /
    • 1968
  • For the effective control of Syphilis, many investigators have developed a more rapid, simple and economical screening serological test which is adequately sensitive and specific. To fulfill the requirements of a more rapid serologic test for syphlis, a substitute for the conventional serum specimen was needed since considerable time and labor are involved in the processing of blood to serum. Burdon suggested the use of plasma in the serologic tests for syphilis as a substitute for serum. He noticed that plasma was more sensitive than serum in the Kline and Kahn tests, and attributed this to the presence of more antibody-like substance, "reagin" in plasma than in serum. However, to make plasma sufficiently sensitive, it was necessary to inactivate plasma by heating at a temperature of $56^{\circ}C$ for about 30 minutes. Heating of plasma resulted in the precipitation of fibrinogen which made centrifugation necessary to obtain dear plasma. Since the chief disadvantage to the use of unheated plasma(or serum) was a reduction in sensitivity of results-which probably was due to a labile factor such as complement-Portnoy et al began to consider rapid chemical methods of inactivation of plasma(or serum). They experienced that choline chloirde was shown to be anticomplementary which suggested its use as an inactivating agent for unheated plasma(or serum). In 1959 Portnoy et al reported the Rapid Plasma Reagin(RPR) Test for syphilis which is a more rapid, economical and simple. But still this test has many disadvantages as a rapid performing, field and office procedure, because it requires the usual laboratory equipments such as centrifuge, rotating machine, microscope etc. To substitute these disadvantages of the RPR test, in 1962, Portnoy et al developed the Rapid Plasma Reagin(RPR) card test for syphilis, which has the following advantages: a) Simplicity and rapidity of performance, b) Requires no laboratory equipments, c) Stable antigen suspension, d) Adequate sensitivity and specificity. This RPR card test can be used as a rapidly performing and screening test in field investigation, outpatient clinics, small laboratories and hospitals doing limited syphilis serology, and predonor in blood bank. Private clinic which has limited laboratory equipment and technic for syphilis serology can also use this RPR card test as a tool in the rapid diagnosis of syphilis. It was thought that this RPR card test is a useful tool in Korea for private physician and mass survey for syphilis diagnosis. But Portnoy patented the reagents needed for the performing the RPR card test. Therefore authors developed newly the reagents and according to Portnoy's method evaluated the newly developed. RPR card test compared with the VDRL, Kolmer CF, and RPCF tests. The RPR card and VDRL tests were performed plasma and serum from the total 1,132 cases. Among these 1,131 cases, 521 were syphilis suspected laboratory specimens, and 611 were syphilis unsuspected healthy young men. After screening with these two tests, the RPR card and VDRL tests, reactive specimens to the above one or both tests were retested by the Kolmer CF and RPCF tests.

  • PDF

Rapid Preparation and Quality Control of $^{99m}Tc$-ECD, $MAG_3$ and MIBI using Microwave Heating and Sep-Pak Cartridges (마이크로웨이브와 Sep-Pak 카트리지를 이용한 $^{99m}Tc$-ECD, $MAG_3$, MIBI의 신속한 제조 및 정도관리)

  • Oh, Seung-Jun;Moon, Dae-Hyuk;Ryu, Jin-Sook;Lee, Hee-Kyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.4
    • /
    • pp.430-438
    • /
    • 1999
  • Purpose: We evaluated a rapid preparation procedures for the labeling and quality control of $^{99m}Tc$-ECD, $MAG_3$, and MIBI using microwave heating and Sep-Pak cartridges. Materials and Methods: $^{99m}Tc$ labeling of ECD, $MAG_3$, and MIBI kit preparation was performed according to the package inserts with microwave heating modification. Heating time was 10-15 sec, and heating was performed with 3 mm plastic bottle with screw cap to prevent radiation contamination. Labeling efficiency was obtained with $C_{18}$ or Alumina N Sep-Pak cartridges. Results: The radiochemical purity of $93{\sim}96%$ for $^{99m}Tc$-ECD and $95{\sim}99%$ for $^{99m}Tc$-MIBI was obtained using Alumina N Sep-Pak cartridge. The optimum irradiation time of microwave method for 3 ml $^{99m}Tc$-labeled radiopharmaceutical solution was 10 sec for $^{99m}Tc$-ECD and $^{99m}Tc$-MIBI, and 15 sec for $^{99m}Tc-MAG_3$. The results of quality control data with Sep-Pak cartridges were well correlated with TLC method. The total preparation time of these radiopharmcaeuticals was $5{\sim}6min$ including quality control procedure. Conclusion: This study demonstrates that radiopharmaceuticals preparation by microwave heating and quality control by Sep-Pak cartridges can be efficiently utilized as an alternative to the recommended method by manufacturer's manual.

  • PDF

Studies on the Characteristics of Rubber Vulcanization Exotherm by Differential Scanning Calorimetry. (Differential Scanning Calorimetry에 의(依)한 고무의 가황발열특성(加黃發熱特性)에 관(關)한 연구(硏究))

  • Choi, Sei-Young;Paik, Nam-Chul
    • Elastomers and Composites
    • /
    • v.19 no.1
    • /
    • pp.13-31
    • /
    • 1984
  • The purposes of this dissertation are to demonstrate that DSC theromoanaytical methods of vulcanization can provide useful informations on the vulcanization characteristics of industrial formulations and also provides the potential basis for a rapid and complete method of sulfur and vulcanizing accelerator analysis for quality control. The influences of those factors such as heating rate, scan temperature, vucanizing accelerator's type and concentration upon vulcanization exotherm in NR and NBR compounds in the presence of vulcanizing accelerators such as TMTD,MBTS,DPG,TMTM,CBS, and MBT were evaluated by means of DSC. In order to examine the credibility in the DSC method, the same samples which were used for DSC method were studied to compare the DSC results with the ODR (Oscillating Disk Rheometer) data. The results obtained were as follows 1. In the DSC dynamic experiments, the observed enthalpy results from vulcanization depends upon the heating rate; In the range of 2 to $20^{\circ}C/min$ of heating rate, as the heating rate was increased the enthalpy change was also increased. However, over the heating rate of $30^{\circ}C/min$ it was observed that the enthalpy change was decreased as the heating rate was further increased. Without regard to the change of enthalpy, tremendous instantaneous heat evolving was observed in the range of high heating rates. 2. For the samples which are added with various vulcanizing accelerators, the activation energies of vulcanization were as follows; 3. Regarding to the influences of vulcanizining accelerator's types upon the characteristics of vulcanization exotherm, NR and NBR compounds in the presence of thiuramsulphide compounds type accelerators such as TMTD, TMTM, were exhibited sharper and higher vulclanization exotherm than others. From the resuts of DSC thermograms which was distributed in even shape in the broad temperature range, it was clearly shown that the guanidine compounds type accelerator such as DPG acts as a delayed acting accelerator. 4. In the comparison of DSC and ODR results, the dependency of temperature in the cure rate and the observed conversions show good agreements between two results. 5. In the same curatives, by the comparison of glass transition temperatures, it was possible to predict relative values of maximum torques. Consequently, from the present studies, it is shown that the DSC thermoanalytical method can provide an alternate new method for rapid and complete quality control analysis of rubber industry.

  • PDF

A Sutdy on the Apllicability of the Energy Pile System on Substation (변전소 구조물의 에너지파일 시스템 적용성 연구)

  • Lee, Daesoo;Oh, Gidae;Lee, Kangyul
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.198-198
    • /
    • 2011
  • Cooling and Heating system using Geothermal energy in the country has shown rapid development in the research and business field during about 10 years. However, like other renewable energy sources, high initial construction cost is acting as an obstacle to apply widely. Therefore Energy pile system(Heat Exchanger inserted inside the structure pile) that can save about 25 % initial construction cost has been studied in European countries and recently being studied in our country. Therefore, KPECO(Korea Electric Power Corporation) is also studying energy pile system to improve cooling & heating system in substation that install about 200 pile. KPECO is aimed to make energy pile design, construction and maintenance standards because substation has good applicability. In this study, we studied to make new grout material and design program to make optimized design & counstruction method of energy pile system. And planing to peform field test for energy pile system in a 154 kV substation to obtain long-term behavior and efficiency of the system.

  • PDF

A Study on the Dyeing of Polyester Fabric by Microwave Heating(I) (Microwave 가열에 의한 Polyester직물의 염색에 관한 연구(I))

  • 서수정;임수경;김삼수
    • Textile Coloration and Finishing
    • /
    • v.10 no.4
    • /
    • pp.7-14
    • /
    • 1998
  • Microwaves are high frequency radiation capable of generating very rapid, uniform and efficient heating of textile material. Microwave heated dyeing of polyester fabric was tried with different solvent systems, irradiation time and dye concentration. Microwave fixation methods were used with 100% water,30% urea, EG and DMF, respectively, pad-baths in which the padded fabrics were exposed over a heated or boiling water bath to maintain sufficient moisture content during irradiation. In order to ascertain the relation between the dyeing property of polyester fabric and the microwave irradiation condition caused by microwave heating, the K/S values and fastness properties of dyed fabrics such as light, washing and sublimation fastness were measured.

  • PDF

Densification of Ultrafine $Si_3-N_4-SiC$ Powder Compacts by Rapid Heating under Controlled Thermograms (급속가열 이력 제어에 의한 $Si_3-N_4-SiC$계 미분말 시편의 치밀화)

  • 이형직
    • Journal of the Korean Ceramic Society
    • /
    • v.32 no.7
    • /
    • pp.832-838
    • /
    • 1995
  • The densifying behavior of ultrafine amorphous Si3N4 (about 20 nm)-$\beta$-SiC (about 40~80 nm) powders (O2 : 1.3~15wt%, 0$700^{\circ}C$ within 15 sec and then immediately cooled and held at 135$0^{\circ}C$ for 10 min in N2 atmosphere without resorting to additives using a Xe image heating apparatus. Using an ultrafine pure Si3N4 powder with particle size less than 30nm, further more, mixed with an appropriate amount of $\beta$-SiC, was found to be advantageous to obtain uniform and homogeneous microstructure. In addition, ultrafine Si3N4 powders were also proved to be effective as sintering additive on densifying large sized Si3N4 powder compacts.

  • PDF

A Study on Control System Of Induction Heating (유도 가열기의 제어시스템에 관한 연구)

  • Kim, Dong-Un;Sung, Nark-Kuy;Han, Kyung-Hee;Choi, Gi-Soo;Ahn, Gyu-Bok;Lee, Seung-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1254-1256
    • /
    • 2000
  • In this paper, a control scheme for induction heating is proposed. The propose scheme estimates, resonant frequency by PI control subbing a phase of output voltage and resonant capacitor voltage. There are would be two advantages in the proposed system over existing induction heating system. One is the rapid resonant frequency estimation. A other is the just control of temperature. Power Circuit is used a inverter stack and transformer rated on 5.5kw.

  • PDF

Confirmation of Applicability of Heating and Curing Method of Concrete in Winter Using Electric Heating System (전기열풍기를 이용한 동절기 콘크리트 가열양생공법 적용 및 적정성 효과 검증)

  • Kim, Se-Jong;Park, Jong-Hoon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.131-132
    • /
    • 2022
  • Looking at recent construction cases at winter construction sites, there is a risk that heat sources such as kerosene fans and fossil fuels (brown coal, molded carbon) used in concrete will cure rapidly, so in situations where further curing is impossible after formwork removal, the outer wall and the entire slab are exposed to rapid external deterioration, resulting in delays in concrete strength expression and until collapse accidents. In this study, we applied kerosene fans and tropical circulating electric heat fans mainly used as curing heat sources at construction sites, comparative analysis. also verified the performance of structures during concrete curing due to thermal convention / circulation performance, concrete demand strength expression, and implementation of electric heat fans by heavy disaster methods.

  • PDF

A study on coil temperature bariation in 75% hydrogen batch annealing furnace (75% 수소 BATCH 소둔시에서의 코일 온도변화에 관한 연구)

  • Jeon, Eon-Chan;Kim, Soon-Kyung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.11 no.2
    • /
    • pp.173-181
    • /
    • 1994
  • A Cold spot temperature control system for the batch annealing furnace has been estabilished in order to reduce energy consumption to improve productivity and stabilize the propertics of products. Therefore we confirmed a relation between annealing cycle time and atmospheric gas, variation of coil cold spot temperature with time during heating and actual temperature measurements at mid-width of each coil during heating and actual temperature measurements at mid-width of each coil during soaking. The results of the tempaeature variation effect on the batch annealing are as follows. 1) Heating time is reduced to one half with increasing atmospheric gas flow rate and changing of atmospheric gas component from HNx to Ax gas, and annealing cycle time is reduced to 2.7 times. 2) In case of short time healing, the slowest heating part is the center of B coil, in case of long time heating, the low temperature point moves from the center of coil to inside coil. And the temperature in this part is higher than other parts when cooling. When finished heating, the cold spot is located 1/3 of coil inside in case of HNx atmospheric gas. But center of coil in case of Ax atmospheric gas. 3) The outside of top coil is the highest temperature point when heating, which becomes the lowest temperature point when cooling. So, this point becomes high temperature zone at heating and low temperature zone at cooling, It has relation according to atmospheric gas component and flow rate. 4) Soaking time at batch annealing cycle determination is made a decision by the input coil width, and soaking time for quality homogenization of 1214mm width coil must be 2.5 hours longer than that of 914mm width coil for the same ciol weight. 5) Annealing cycle time with Ax atmospheric gas is extended 1 hour in of slow cooling during 5 hours in order to avoid rapid cooling.

  • PDF