• 제목/요약/키워드: Rapid evaluation

검색결과 1,644건 처리시간 0.027초

건축 산업에서의 신속조형기술 응용과 교육 연구 -미국의 중소규모 사무소와 대학원 CAAD 교육을 중심으로- (Research of Application of Rapid Prototyping in Architectural Industry and Its Educational Status - With Focus on the Mid-size Firm and Graduate CAAD Education in U.S-)

  • Jung, C. H.
    • 한국CDE학회논문집
    • /
    • 제9권1호
    • /
    • pp.77-91
    • /
    • 2004
  • Integrating computer-aided design with computer-aided fabrication and construction will fundamentally redefine the relationship between design and construction. Rapid prototyping(RP) is evaluated as one of the integration method available but it has been regarded as very expensive and complex design evaluation tool and is only suitable for large mechanical design shops in automobile and aerospace industry. However current status of rapid prototyping is changing since the new generation of RP equipment, less expensive and more user-friendlier, now can be installed and use in design firms. Simultaneously increasing use of 3D CAAD software is also helping to use rapid prototyping widely. It is crucial to acknowledge rapid prototyping technologies are not only for avant-garde architect such as Frank O. Gehry but ordinary 90% architects, who can have benefit from fast and cost-effective technology. With its fast development and adaptation in architectural industry, it is quite necessary to include rapid prototyping education in regular CAAD courses either undergraduate or graduate level.

전립선특이항원검사 Kit에 의한 정액의 신속 검출법 (Forensic Evaluation of Prostate-Specific-Antigen (PSA) Rapid Test Kit for Identification of Human Semen)

  • 임채원;이종훈;김형락
    • 대한임상검사과학회지
    • /
    • 제41권2호
    • /
    • pp.76-82
    • /
    • 2009
  • It would be one of the most important tests that determination of semen in crime scene as a matter of significant evidences. Recently, it has been developed for the identification of semen in forensic specimens which was used simply, easily and reproductively. In this study, Prostate-Specific-Antigen (PSA) Rapid Test kit was evaluated for the forensic identification of semen and compared with one step semen inspection forensic rapid test kit. The sensitivity and specificity of the rapid PSA kit were examined in addition to the stability of PSA. The positive band of rapid PSA kit shown even with 1,000,000-fold diluted semen, which was at least 100 timed higher than qualitative one step semen inspection forensic rapid test kit. PSA was detected in urine from normal male adult, however, it was not detected in urine from young boys and female body fluids. It was shown that PSA was very stable to resist boiling for 20 minutes and the effect of bacteria. In crime scene investigation, rapid PSA kit is expected to help to identify semen easily in the evidences.

  • PDF

Validation of One-Step Real-Time RT-PCR Assay in Combination with Automated RNA Extraction for Rapid Detection and Quantitation of Hepatitis C Virus RNA for Routine Testing in Clinical Specimens

  • KIM BYOUNG-GUK;JEONG HYE-SUNG;BAEK SUN-YOUNG;SHIN JIN-HO;KIM JAE-OK;MIN KYUNG-IL;RYU SEUNG-REL;MIN BOK-SOON;KIM DO-KEUN;JEONG YONG-SEOK;PARK SUE-NIE
    • Journal of Microbiology and Biotechnology
    • /
    • 제15권3호
    • /
    • pp.595-602
    • /
    • 2005
  • A one-step real-time quantitative RT-PCR assay in combination with automated RNA extraction was evaluated for routine testing of HCV RNA in the laboratory. Specific primers and probes were developed to detect 302 bp on 5'-UTR of HCV RNA. The assay was able to quantitate a dynamic linear range of $10^7-10^1$ HCV RNA copies/reaction ($R^2=0.997$). The synthetic HCV RNA standard of $1.84{\pm}0.1\;(mean{\pm}SD)$ copies developed in this study corresponded to 1 international unit (IU) of WHO International Standard for HCV RNA (96/790 I). The detection limit of the assay was 3 RNA copies/reaction (81 IU/ml) in plasma samples. The assay was comparable to the Amplicor HCV Monitor (Monitor) assay with correlation coefficient r=0.985, but was more sensitive than the Monitor assay. The assay could be completed within 3 h from RNA extraction to detection and data analysis for up to 32 samples. It allowed rapid RNA extraction, detection, and quantitation of HCV RNA in plasma samples. The method provided sufficient sensitivity and reproducibility and proved to be fast and labor-saving, so that it was suitable for high throughput HCV RNA test.

Hydrometer를 이용한 고로슬래그 미분말의 분말도 품질 신속평가 가능성 분석 (Feasibility Analysis of Rapid Quality Evaluation Method for Blast Furnace Slag Using Hydrometer)

  • 한천구;주은희
    • 한국건설순환자원학회논문집
    • /
    • 제6권1호
    • /
    • pp.43-49
    • /
    • 2018
  • 본 연구에서는 고로슬래그의 원료인 수쇄슬래그를 Ball mill로 분말도에 다양한 변화를 주어 제조한 다음 종전에 진행되었던 Hydrometer를 이용한 비중계법 콘크리트 조기 강도 추정의 원리를 적용하여 BS의 분말도 품질을 저렴하면서도 간편하고 신속하게 평가함으로써 BS 분말도 수입검사에 효과적으로 활용할 수 있도록 함에 있어 그 가능성을 분석하고자 하였다. 실험 결과 BS의 분말도가 클수록 액체밀도계의 침하시간이 지연되는 것으로 나타났으며, 3분의 혼탁액 밀도와 분말도의 상관관계 회귀식 y = 198 120 x - 193 936(R=0.9398)을 활용할 시 BS 분말도의 신속한 품질평가가 가능할 것으로 판단되었다. 따라서 레미콘 인수검사에서 BS의 분말도 품질 신속평가로 본 연구에서 제시하는 방법을 적용할 경우 저렴하고 간단하며 신속하게 BS 분말도 평가가 가능할 수 있을 것으로 분석되었다.

Evaluation of Rapid filtration System with Particle Size Distribution and Turbidity in Different Effective Sizes

  • Park, J.A.;Eo, S.M.;Shin, J.S.;Kim, M.H.;Yu, M.J.;Chung, S.H.
    • 한국환경보건학회:학술대회논문집
    • /
    • 한국환경보건학회 2005년도 국제학술대회
    • /
    • pp.381-385
    • /
    • 2005
  • Characterization of particle behavior is becoming more important in performance evaluation of water treatment system as well as in operation of the system because conventional parameter, turbidity has lack of explaining ability on small sized microorganisms such like Cryptosporidium etc. Accordingly, particle counter has been introduced in evaluation and operation of the treatment system. However researches on the relationship between turbidity, particle count and/or different sand/anthracite sizes have not been concurrent. Therefore in this study, the relationship was investigated to improve performance evaluation of sand filter so as to help choosing sand/anthracite effective size as a design parameter of water treatment facility. According to the results, too small or too large effective size media filter reached to turbidity limit(0.1 NTU)earlier. However, because shallow sand layer may cause early breakthrough, the depth of sand layer should be provided enough in order to compromise water quality and productivity.

  • PDF

RP 공정의 정밀도 비교 평가 (Comparison of Accuracy of RP Processes)

  • 변홍석;신행재;이관행
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 추계학술대회 논문집
    • /
    • pp.330-333
    • /
    • 2000
  • Dimensional accuracy and surface quality are very important in rapid prototyping especially when the models are used for the production of tools. This paper presents the development of benchmarking part to investigate dimensional accuracy and surface finish. A new test part is designed to perform benchmarking of major rapid prototyping processes such as selective laser sintering, laminated object manufacturing, stereolithography apparatus, and fused deposition modeling. The test part design includes basic manufacturing features such as holes, walls, squares, cylinder and etc. In addition, the small features are included in order to evaluate the fine details that can be manufactured by a specific RP process. The CMM program that automatically measures different features in the test part is also developed. The evaluation of accuracy as well as surface roughness are discussed for major rapid prototyping processes.

  • PDF

Evaluation of Rapid Immunochromatographic Assay Kit for HBsAg-Screening Using Whole Blood

  • Shin, Hyeong-Soon;Heo, Tae-Ryeon
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제5권5호
    • /
    • pp.362-365
    • /
    • 2000
  • A rapid immunochromatographic assay kit using whole blood to screen hepatitis B surface antigen was developed and evaluated by using sera from 240 patients. The reference diagnosis was based on the results obtained with GENEDIA Anti-HBs Rapid kit which is very similar to the above kit except for the use of serum. The test demonstrated a good correlation with the reference immunochromatographic assay kit, that is, the sensitivity and the specificity of the kit was 100%, respectively. The rapid test kit using whole blood should be more convenient and useful for the diagnosis of hepatitis B virus because the kit does not need machines and time to prepare serum. In addition, this kit is safe from inadvertent infection during sample treatment because the blood is sterilized with hydrogen peroxide, eliminates the procedure required to prepare serum and reduces the possibility of exposure to infectious agents.

  • PDF

개인고속이동(Personal Rapid Transit) 시스템의 운전시격에 대한 연구 (A Study on the Headway of the Personal Rapid Transit System)

  • 신덕호;김용규;이준호
    • 한국철도학회논문집
    • /
    • 제8권6호
    • /
    • pp.586-591
    • /
    • 2005
  • We deal with the headway which effects on the performance of the PRT(Personal Rapid Transit) system and the system safety. The headway, time between passage of one vehicle and the next, is one of the important factors to assess the line capacity, which has a cue to solve the problem of the congestion in public transportation. To decide the headway there are many important factors, especially such as the failure vehicle deceleration rate, the following simple analytical equation can be made to assess the relation between the line speed and the minimum headway. In this paper we employ a numerical analysis method using a simple analytical equations for the evaluation of the minimum headway and show simple simulation results.

적외선 램프를 이용하여 소결한 구리 나노잉크의 전기적 특성 평가에 관한 연구 (Electrical Property Evaluation of Printed Copper Nano-Ink Annealed with Infrared-Lamp Rapid Thermal Process)

  • 한현숙;김창규;양승진;김윤현
    • 한국재료학회지
    • /
    • 제26권4호
    • /
    • pp.216-221
    • /
    • 2016
  • A sintering process for copper based films using a rapid thermal process with infrared lamps is proposed to improve the electrical properties. Compared with films produced by conventional thermal sintering, the microstructure of the copper based films contained fewer internal and interfacial pores and larger grains after the rapid thermal process. This high-density microstructure is due to the high heating rate, which causes the abrupt decomposition of the organic shell at higher temperatures than is the case for the low heating rate; the high heating rate also induces densification of the copper based films. In order to confirm the effect of the rapid thermal process on copper nanoink, copper based films were prepared under varying of conditions such as the sintering temperature, time, and heating rate. As a result, the resistivity of the copper based films showed no significant changes at high temperature ($300^{\circ}C$) according to the sintering conditions. On the other hand, at low temperatures, the resistivity of the copper based films depended on the heating rate of the rapid thermal process.

MediaPipe를 이용한 목재 제조업 작업자의 근골격계 유해요인 평가 방법 (An Evaluation Method for the Musculoskeletal Hazards in Wood Manufacturing Workers Using MediaPipe)

  • 정성오;국중진
    • 반도체디스플레이기술학회지
    • /
    • 제21권2호
    • /
    • pp.117-122
    • /
    • 2022
  • This paper proposes a method for evaluating the work of manufacturing workers using MediaPipe as a risk factor for musculoskeletal diseases. Recently, musculoskeletal disorders (MSDs) caused by repeated working attitudes in industrial sites have emerged as one of the biggest problems in the industrial health field while increasing public interest. The Korea Occupational Safety and Health Agency presents tools such as NIOSH Lifting Equations (NIOSH), OWAS (Ovako Working-posture Analysis System), Rapid Upper Limb Assessment (RULA), and Rapid Entertainment Assessment (REBA) as ways to quantitatively calculate the risk of musculoskeletal diseases that can occur due to workers' repeated working attitudes. To compensate for these shortcomings, the system proposed in this study obtains the position of the joint by estimating the posture of the worker using the posture estimation learning model of MediaPipe. The position of the joint is calculated using inverse kinetics to obtain an angle and substitute it into the REBA equation to calculate the load level of the working posture. The calculated result was compared to the expert's image-based REBA evaluation result, and if there was a result with a large error, feedback was conducted with the expert again.