• 제목/요약/키워드: Rapid diagnostic kit

Search Result 52, Processing Time 0.027 seconds

Development of a High-performance COVID-19 Diagnostic Kit Employing Improved Antibody-quantum dot Conjugate

  • Seongsoo Kim;Hyunsoo Na;Hong-Geun Ahn;Han-Sam Park;Jaewoong Seol;Il-Hoon Cho
    • Biomedical Science Letters
    • /
    • v.29 no.4
    • /
    • pp.344-354
    • /
    • 2023
  • This study emphasizes the importance of early diagnosis and response to COVID-19, leading to the development of a rapid diagnostic kit using quantum dots. The research focuses on finely tuning bioconjugation with quantum dots to enhance the accuracy and sensitivity of COVID-19 diagnosis. We have developed a COVID-19 rapid diagnostic kit that exhibits a sensitivity more than 50 times higher than existing COVID-19 diagnostic kits. Quantum dots enable the accurate detection of COVID-19 viral antigens even at low concentrations, providing a rapid response in the early stages of infection. The COVID-19 quantum dot diagnostic kit offers quick analysis time, utilizing the quantum properties of particles to swiftly measure COVID-19 infection for immediate response and isolation measures. Additionally, this diagnostic kit allows for multiple analyses with ease, as multiple quantum dots can detect various antigens and antibodies simultaneously in a single experiment. This efficiency enhances testing, reduces sample requirements, and lowers experimental costs. The application of this diagnostic technology is anticipated in the future for early diagnosis and monitoring of other infectious diseases.

Evaluation of the Malaria Rapid Diagnostic Kit in Ganghwa County (강화군에서 시행한 말라리아 신속진단킷트의 유용성 평가)

  • Kweon, Su-Jung;Kweon, Oh-Jun;Youn, Sung-Tae;Yim, Jun;Im, Jeong-Soo
    • Journal of agricultural medicine and community health
    • /
    • v.31 no.2
    • /
    • pp.157-164
    • /
    • 2006
  • Objectives: Early diagnosis and treatment is the most important strategy to control malaria effectively. Microscopic examination of blood films is a traditional and standard method for diagnosing malaria, which takes a long time and needs expertise, Therefore, the alternative method, rapid diagnostic kit has been used for quick diagnosis in some counties, a highly infectious region by P. vivax. The purpose of this study was to evaluate the utility of malaria rapid diagnostic kit in Ganghwa county. Methods: The utility was evaluated by mean diagnosis time and sensitivity and specificity. For monitoring mean diagnosis time, 942 cases which were diagnosed for P. vivax were collected between 1998 and 2005, And for calculating sensitivity and specificity, 434 whole bloods in EDTA which were presented for P. vivax by microscopy and rapid diagnostic kit were collected between 2004 and 2005. Results: After malaria rapid diagnostic kit was used in 2003, mean diagnosis time has decreased to 3.36-3.14 day. The sensitivity and specificity of the rapid diagnostic kit was 98.2% and 98,5% and comparable to that of microscopic examination. Conclusions: The malaria rapid diagnostic kit is useful tool in a highly infectious region like Ganghwa county.

  • PDF

How accurate are rapid diagnostic tests for covid-19? (코로나19 신속진단검사는 얼마나 정확한가?)

  • Yeo, In-Kwon
    • The Korean Journal of Applied Statistics
    • /
    • v.35 no.3
    • /
    • pp.435-443
    • /
    • 2022
  • In this paper, using Covid-19 diagnostic data provided by the Korea Disease Control and Prevention Agency (KDCA), we examine the probability of confirmed cases and the probability of actually being confirmed when the rapid test is negative according to the sensitivity and specificity of the rapid diagnostic kit. When we know the conditional probability of confirmation given a positive test, we induce the relationship between sensitivity and specificity, and compute the actual sensitivity of the rapid diagnosis kit based on the data of KDCA.

Development of Automated Rapid Influenza Diagnostic Test Method Based on Image Recognition (영상 인식 기반 신속 인플루엔자 자동 판독 기법 개발)

  • Lee, Ji Eun;Joo, Yoon Ha;Lee, Jung Chan
    • Journal of Biomedical Engineering Research
    • /
    • v.40 no.3
    • /
    • pp.97-104
    • /
    • 2019
  • To examine different types of influenza diagnostic test kits automatically, automated rapid influenza diagnostic test method based on image recognition is proposed in this paper. First, the proposed methods classify a variety of the rapid influenza diagnostic test kit based on support vector machine that analyzes the kits' feature point. Then, to improve the accuracy of test, the proposed methods match the histogram of both the target image of influenza kit and the input image of influenza kit for minimizing the effect of environment factors, such as lighting and exposure variations. And, to minimize the effect from composition of the hand-helds devices, the proposed methods extract the feature point and match point-by-point between target image of influenza kit and input image of influenza kit. Experimental results of 124 experimental group show that the proposed methods significantly have effectiveness, which shows 90% accuracy in moderate antigen, for the preliminary examination of influenza, and provides the opportunity for taking action against influenza.

Analysis of prevalence and risk factors of diarrhea in dairy calf using a rapid diagnostic kit in Gyeonggi province (신속진단키트를 활용한 경기지역 젖소 송아지 설사병 유병률과 위험요인 분석)

  • Taemook Park;Gil Jae Cho;Young Jin Yang;Il-Sun Ryu
    • Korean Journal of Veterinary Service
    • /
    • v.46 no.2
    • /
    • pp.147-156
    • /
    • 2023
  • Between February 2020 and September 2021, a total of 452 dairy calves with diarrhea were investigated across 17 dairy farms in Gyeonggi province, Korea, using a rapid diagnostic kit. The study aimed to examine the infection rates of major pathogens causing diarrhea in dairy calves, categorizing them by season, age, and birth month. Additionally, logistic regression analysis was conducted to investigate the factors affecting the infection rate. The infection rates of the major pathogens causing infectious diarrhea in dairy calves, including bovine rotavirus, bovine coronavirus, Cryptosporidium, and E. coli, are influenced by season, age, and birth month. Bovine coronavirus and Cryptosporidium showed variations in infection rates according to season, age, and birth month, while bovine coronavirus was influenced by age and birth month, and E. coli showed variations in infection rates based on age. Furthermore, in the analysis of risk factors influencing the infection rates of these pathogens, age and birth month were identified as risk factors for bovine rotavirus, bovine coronavirus, and Cryptosporidium.

Clinical evaluation of a rapid diagnostic test kit for detection of canine coronavirus

  • Yoon, Seung-Jae;Seo, Kyoung-Won;Song, Kun-Ho
    • Korean Journal of Veterinary Research
    • /
    • v.58 no.1
    • /
    • pp.27-31
    • /
    • 2018
  • Canine coronavirus is a single-stranded RNA virus that causes enteritis in dogs of any age. Coronaviral enteritis is seldom definitively diagnosed, since it is usually much less severe than many other types of enteritis and is self-limiting. Conventional diagnostics for the canine coronaviral enteritis such as polymerase chain reaction (PCR), virus isolation, and electron microscopic examination are inappropriate for small animal clinics due to the complicated experimental processes involved. Therefore, a commercially available lateral flow test kit based on chromatographic immunoassay techniques was tested to evaluate its performance as a first-line diagnostic test kit that could be used in clinics. The coronavirus antigen test kit detected canine coronavirus-infected dogs with 93.1% sensitivity and 97.5% specificity. The detection limit of the test kit was between $1.97{\times}10^4/mL$ and $9.85{\times}10^3/mL$ for samples with a 2-fold serial dilution from $1.25{\times}10^6\;TCID_{50}$ ($TCID_{50}$, 50% tissue culture infectious dose). Additionally, the test kit had no cross-reactivity with canine parvovirus, distemper virus, or Escherichia coli. Overall, the commercially available test kit showed good diagnostic performance in a clinical setting, with results similar to those from PCR, confirming their potential for convenient and accurate use in small animal clinics.

Development of Rapid Diagnostic Technology for Pig Disease (2) - Rapid detection of PPE in the pig feces -

  • Kim, Hyuck-Joo;Hong, Jong-Tae;Yu, Byeong-Kee;Kim, Giyoung;Kim, Suk
    • Journal of Biosystems Engineering
    • /
    • v.38 no.2
    • /
    • pp.121-128
    • /
    • 2013
  • Purpose: Porcine proliferative enteropathy (PPE), caused by the obligate intracellular bacterium Lawsonia intracellularis, is a widely distributed disease throughout the world causing substantial economic loss. In order to diagnose PPE rapidly, the rapid kit was developed and tested. Methods: In this study, a rapid kit was developed to screen the PPE rapidly at the pig farm. Also, occult blood test with fecal occult blood (FOB) kit was done for detecting the blood in pig feces which might be the evident of hemorrhagic PPE. For developing the kit, we tested fecal samples of PPE infected pigs diagnosed by polymerase chain reaction (PCR) method. Results: With the developed rapid kit, Lawsonia intracellularis was detected in high density emulsion of ileum. On the other hand, the test result of detecting Lawsonia in feces showed too high non-specific response. In addition, nevertheless the FOB test result showed that blood evident could be founded in pig feces, the diagnosing result was not fit to PCR test result, which shows blood in pig feces could be from not only hemorrhagic PPE but also many reasons. Conclusions: To deal with the PPE effectively, it will be better for farmers to screen the PPE in earlier stage with easy and rapid diagnosing tool on farm. This study found out that the rapid kit could detect the Lawsonia intracellularis and hemoglobin in pig feces. However, the non-specific response to negative samples of PPE was too high to use at a pig farm. Further research is needed for lowering the non-specific response with the rapid kit.

Development and Clinical Evaluation of a Rapid Serodiagnostic Test for Toxoplasmosis of Cats Using Recombinant SAG1 Antigen

  • Chong, Chom-Kyu;Jeong, Woo-Seog;Kim, Hak-Yong;An, Dong-Jun;Jeoung, Hye-Young;Ryu, Jeong-Eun;Ko, A-Ra;Kim, Yong-Joo;Hong, Sung-Jong;Yang, Zhaoshou;Nam, Ho-Woo
    • Parasites, Hosts and Diseases
    • /
    • v.49 no.3
    • /
    • pp.207-212
    • /
    • 2011
  • Rapid serodiagnostic methods for Toxoplasma gondii infection in cats are urgently needed for effective control of transmission routes toward human infections. In this work, 4 recombinant T. gondii antigens (SAG1, SAG2, GRA3, and GRA6) were produced and tested for the development of rapid diagnostic test (RDT). The proteins were expressed in Escherichia coli, affinity-purified, and applied onto the nitrocellulose membrane of the test strip. The recombinant SAG1 (rSAG1) showed the strongest antigenic activity and highest specificity among them. We also performed clinical evaluation of the rSAG1-loaded RDT in 182 cat sera (55 household and 127 stray cats). The kit showed 0.88 of kappa value comparing with a commercialized ELISA kit, which indicated a significant correlation between rSAG1-loaded RDT and the ELISA kit. The overall sensitivity and specificity of the RDT were 100% (23/23) and 99.4% (158/159), respectively. The rSAG1-loaded RDT is rapid, easy to use, and highly accurate. Thus, it would be a suitable diagnostic tool for rapid detection of antibodies in T. gondii-infected cats under field conditions.

Development of a Rapid Diagnostic Test Kit to Detect IgG/IgM Antibody against Zika Virus Using Monoclonal Antibodies to the Envelope and Non-structural Protein 1 of the Virus

  • Kim, Yeong Hoon;Lee, Jihoo;Kim, Young-Eun;Chong, Chom-Kyu;Pinchemel, Yanaihara;Reisdorfer, Francis;Coelho, Joyce Brito;Dias, Ronaldo Ferreira;Bae, Pan Kee;Gusmao, Zuinara Pereira Maia;Ahn, Hye-Jin;Nam, Ho-Woo
    • Parasites, Hosts and Diseases
    • /
    • v.56 no.1
    • /
    • pp.61-70
    • /
    • 2018
  • We developed a Rapid Diagnostic Test (RDT) kit for detecting IgG/IgM antibodies against Zika virus (ZIKV) using monoclonal antibodies to the envelope (E) and non-structural protein 1 (NS1) of ZIKV. These proteins were produced using baculovirus expression vector with Sf9 cells. Monoclonal antibodies J2G7 to NS1 and J5E1 to E protein were selected and conjugated with colloidal gold to produce the Zika IgG/IgM RDT kit (Zika RDT). Comparisons with ELISA, plaque reduction neutralization test (PRNT), and PCR were done to investigate the analytical sensitivity of Zika RDT, which resulted in 100% identical results. Sensitivity and specificity of Zika RDT in a field test was determined using positive and negative samples from Brazil and Korea. The diagnostic accuracy of Zika RDT was fairly high; sensitivity and specificity for IgG was 99.0 and 99.3%, respectively, while for IgM it was 96.7 and 98.7%, respectively. Cross reaction with dengue virus was evaluated using anti-Dengue Mixed Titer Performance Panel (PVD201), in which the Zika RDT showed cross-reactions with DENV in 16.7% and 5.6% in IgG and IgM, respectively. Cross reactions were not observed with West Nile, yellow fever, and hepatitis C virus infected sera. Zika RDT kit is very simple to use, rapid to assay, and very sensitive, and highly specific. Therefore, it would serve as a choice of method for point-of-care diagnosis and large scale surveys of ZIKV infection under clinical or field conditions worldwide in endemic areas.

A Comparative Evaluation of Three Rapid Tests of Syphilis and ARCHITECT Syphilis TP

  • Kim, Won-Shik
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.43 no.1
    • /
    • pp.1-5
    • /
    • 2011
  • The infection rate of syphilis is still increasing in the world especially in developing countries and the infection is often seen in large amounts of clinical specimens. For the diagnosis of this disease, Rapid Plasma Reagin (RPR)/Venereal Disease Research Laboratory (VDRL) has still been used as one of major primary methods to diagnose syphilis even though the test readings are somewhat subjective with high false positive rates. Recently, the automatic ARCHITECT Syphilis TP, which is based on the detection of the TP-specific antibodies, has been introduced in many laboratories. Therefore, the clinical assessment of the method is needed to provide primary diagnosis of syphilis at the moment. We evaluated 3 different manual rapid kits and ARCHITECT Syphilis TP comparing with RPR/FTA-ABS and analysed their diagnostic properties. From February 2006 to April 2008, 203 positive and 250 negative specimens, obtained from Chungbuk National University Hospital were used for the evaluation. In the evaluation between manual rapid kits, their specificities were as high as 99.2 ~ 99.6% while their sensitivities were observed with little differences; 98.0% (199/203) for Kit A, 96.6% (196/203) for Kit B, and 97.4% (197/203) for Kit S. In the case of ARCHITECT Syphilis TP test, it showed 100% specificity (250/250) and 98.5% sensitivity (249/250). Kappa values comparing with RPR/FTA-ABS were 0.978 for Kit A, 0.964 for Kit B and Kit S, and 0.987 for ARCHITECT Syphilis TP. From our evaluation, we found out that manual rapid tests and ARCHITECT Syphilis TP have very good clinical accuracies and high kappa agreements with RPR/FTA-ABS. Due to its automation and quick simultaneous diagnosis with another serological markers, we suggest that the ARCHITECT Syphilis TP is one of best suitable method for the primary diagnosis of syphilis and that it might be able to replace RPR method in the laboratories.

  • PDF