Evaluation of Rapid Immunochromatographic Assay Kit for HBsAg-Screening Using Whole Blood

  • Shin, Hyeong-Soon;Heo, Tae-Ryeon
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.5 no.5
    • /
    • pp.362-365
    • /
    • 2000
  • A rapid immunochromatographic assay kit using whole blood to screen hepatitis B surface antigen was developed and evaluated by using sera from 240 patients. The reference diagnosis was based on the results obtained with GENEDIA Anti-HBs Rapid kit which is very similar to the above kit except for the use of serum. The test demonstrated a good correlation with the reference immunochromatographic assay kit, that is, the sensitivity and the specificity of the kit was 100%, respectively. The rapid test kit using whole blood should be more convenient and useful for the diagnosis of hepatitis B virus because the kit does not need machines and time to prepare serum. In addition, this kit is safe from inadvertent infection during sample treatment because the blood is sterilized with hydrogen peroxide, eliminates the procedure required to prepare serum and reduces the possibility of exposure to infectious agents.

  • PDF

The Evaluation of Immunochromatographic Assay kit for Rapid Detection of Hepatitis B Surface Antigen (Hepatitis B Surface Antigen을 신속히 검출하기 위한 Immunochromatographic Assay kit의 성능 평가)

  • Shin, Hyeong-Soon;Kim, Young-Bong;Shin, Jung-Woo;Kim, Chang-Kyu;Lee, Wang-Sik;Kim, Han-Kyeom;Shin, Kwang-Soon
    • The Journal of Korean Society of Virology
    • /
    • v.27 no.2
    • /
    • pp.137-141
    • /
    • 1997
  • We evaluated Immunochromatographic assay kit to screen HBsAg in human serum. When the reference HBsAg was applyed to ICA, HA and EIA kits, the limit of detection for HBsAg were found out to be 4, 2 and 0.25 ng/ml respectively. But ICA kit required 5 minutes to read the result whereas HA and EIA kit more than one hour. The sensitivity was 97% (29 of 30 samples) and the specificity 100% (45 samples) compared with conventional EIA. The ICA kit needs no instrument or machine to perform the test contrary to the conventional methods. Therefore, this rapid and sensitive ICA kit can be used for HBsAg-screening, especially in the emergency room and in the scene of the accident.

  • PDF

Quantitation of Antigen-Antibody Reaction Condition for Development of Fluorescence Image-based CD4 Rapid Test (형광 영상 기반 CD4 신속 검사법 개발을 위한 항원-항체 반응 조건 정량화)

  • Kim, Subin;Kim, Jung Kyung
    • Journal of the Korean Society of Visualization
    • /
    • v.13 no.1
    • /
    • pp.35-42
    • /
    • 2015
  • CD4+ T-cell count determines the effectiveness for antiretroviral therapy (ART) in patients with human immunodeficiency virus (HIV). Although ART slows the progression of HIV to AIDS, rapid counting of CD4+ T lymphocytes with a drop of patient's blood sample is urgently needed to ensure timely ART treatment in rural areas. Recently point-of-care CD4 testing devices have been developed by using non-flow based imaging cytometer incorporated with a sample cartridge where CD4+ T cells are reacted with fluorescently tagged specific antibodies. Here we conducted an experimental study using a conventional fluorescence microscope-based imaging system to quantitate the interaction of CD4 antibodies with CD4+ T cells at different reaction conditions. We demonstrated that a fast and affordable point-of-care CD4 test is feasible with a far less amount of antibodies and a shorter incubation time compared with a conventional sample preparation protocol for flow cytometry. We also proposed a general method to evaluate and compare the detection limit across different CD4 counting platforms by using fluorescently labelled microbeads for intensity calibration.

Diagnostic value of a dot immunobinding assay for human pulmonary hydatidosis

  • OLUT Ali I.;ERGUVEN Sibel;EMRI Salih;OZUNLU Haluk;AKAY Hadi
    • Parasites, Hosts and Diseases
    • /
    • v.43 no.1 s.133
    • /
    • pp.15-18
    • /
    • 2005
  • The diagnosis of human hydatidosis is primarily made using radiological and serological methods. Radiological methods are generally of low specificity and serological methods lack sensitivity, especially for pulmonary disease. In this study the capabilities of a new rapid test, the hydatid antigen dot immunobinding assay (HA-DIA), which was developed for the diagnosis of pulmonary hydatidosis, were studied and compared with another immunodiagnostic method, indirect hemagglutination (IHA). The study subjects included 18 patients, 9 women, 9 men; range 7 to 63 years; mean 30 years, with surgically proven pulmonary hydatidosis, a control group comprised of 14 patients; viral respiratory infections (1), cirrhosis (2), connective tissue disease (2), taeniasis (3), and 6 healthy donors. We found that the HA-DIA test had a sensitivity of $67\%$ and specificity of $100\%$, and that the IHA test had a sensitivity of $50\%$ and specificity of $100\%$. We conclude that HA-DIA is a simple, rapid, low cost assay that does not require instrumentation and has a higher sensitivity than IHA for the diagnosis of pulmonary hydatidosis.

Quantitative Assay of Recombinant Hepatitis B Surface Antigen by Using Surface Plasmon Resonance Biosensor (Surface plasmon resonance 바이오센서를 이용한 재조합 B형 간염 표면항원의 정량분석)

  • Lee, E. K.;Ahn, S. J.;Yoo, C. H.;Ryu, K.;Jeon, J. Y.;Lee, H. I.;Choi, S. C.;Lee, Y. S.
    • KSBB Journal
    • /
    • v.17 no.1
    • /
    • pp.20-25
    • /
    • 2002
  • We performed a basic experiment for rapid, on-line, real-time measurement of HBsAg by using a surface plasmon resonance biosensor to quantify the recognition and interaction of biomolecules. We immobilized the anti-HBsAg polyclonal antibody to the dextran layer on a CM5 chip surface which was pre-activated by N-hydroxysuccinimide for amine coupling. The binding of the HBsAg to the immobilized antibody was measured by the mass increase detected by the change in the SPR signal. The binding characteristics between HBsAg and its antibody followed typical monolayer adsorption isotherm. When the entire immobilized antibody was interacted, there was no additional, non-specific binding observed, which suggested the biointeraction was very specific as expected and independent of the ligand density. No significant steric hindrance was observed at 17.6 nm/$mm^2$ immobilization density. The relationship between the HBsAg concentration in the sample solution and the antigen bound to the chip surface was linear up to ca. $40\mu\textrm{g}$/mL, which is much wider than that of the ELISA method. It appeared the antigen-antibody binding was increased as the immobilized ligand density increased, but verification is warranted. This study showed the potential of this biosensor-based method as a rapid, simple, multi-sample, on-line assay. Once properly validated, it can serve as a more powerful method for HBsAg quantification replacing the current ELISA method.

Evaluation of the Clinical Usefulness of the Xeniss Rapid TB kit for the Diagnosis of Tuberculosis (결핵진단에서 Xeniss Rapid TB kit의 임상적 유용성)

  • Park, Seung-Kyu;Lee, Woo-Chul;Hwang, Soo-Hee;Kwon, Eun-Si;Lee, Hung-Soon;Lee, Duk-Hyoung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.53 no.4
    • /
    • pp.389-400
    • /
    • 2002
  • Background : The rapid diagnostic tests for tuberculosis are needed to facilitate early treatment of tuberculosis and prevention of Mycobacterium tuberculosis transmission. The Xeniss Rapid TB kit is a rapid, card-based immunochromatographic test for the detection of antibodies directed against M. tuberculosis antigens including antigen 5(38-kDa antigen). The objective of this study was to evaluate the performance of the Xeniss Rapid TB kit for the diagnosis of active tuberculosis with serums from patients, asymptomatic healthy and close contact controls. Methods : 188 patients with active tuberculosis were tested; 177 with pulmonary tuberculosis(18 with combined pleurisy), and 11 with extrapulmonary tuberculosis. The control groups were composed of 82 close contacts and 57 healthy adults. Study subject were drawn from one national tuberculosis hospital for patients and close contacts, and another private hospital for healthy adults in Masan city, Korea. The Xeniss Rapid TB kit(Xeniss Life Science Co., Ltd., Seoul, Korea) was evaluated by using serum samples according to the instructions of the manufacturer by an investigator masked to the clinical and microbiological status of the study subjects. Results : The diagnostic sensitivity of the Xeniss Rapid TB kit was 73.9% in patients and specificities were 73.2% and 93.0% in close contact and healthy adults respectively. The positive predictive value in patients was 84.2% and the negative predictive value in controls was 85.8%. Conclusion : This study shows that the Xeniss Rapid TB test is a simple and fast method to diagnose active TB. The results of the sensitivity and specificites suggest that serodiagnosis using this point of care testing(POCT) device would be valuable and advantageous for screening tuberculosis in the clinical field.

Dot-Blot Immunoassay of Fasciola gigantica Infection using 27 kDa and Adult Worm Regurge Antigens in Egyptian Patients

  • Kamel, Hanan H.;Saad, Ghada A.;Sarhan, Rania M.
    • Parasites, Hosts and Diseases
    • /
    • v.51 no.2
    • /
    • pp.177-182
    • /
    • 2013
  • The purpose of the present study was to evaluate the potential role of the 27-Kilodalton (KDa) antigen versus Fasciola gigantica adult worm regurge antigens in a DOT-Blot assay and to assess this assay as a practical tool for diagnosis fascioliasis in Egyptian patients. Fasciola gigantica antigen of an approximate molecular mass 27- (KDa) was obtained from adult worms by a simple elution SDS-PAGE. A Dot-Blot was developed comparatively to adult worm regurge antigens for the detection of specific antibodies from patients infected with F. gigantica in Egypt. Control sera were obtained from patients with other parasitic infections and healthy volunteers to assess the test and compare between the antigens. The sensitivity, specificity, positive and negative predictive values of Dot-Blot using the adult worm regurge were 80%, 90%, 94.1%, and 69.2% respectively, while those using 27-KDa were 100% which confirms the diagnostic potential of this antigen. All patients infected with Fasciola were positive, with cross reactivity reported with Schistosoma mansoni serum samples. This 27-KDa Dot-Blot assay showed to be a promising test which can be used for serodiagnosis of fascioliasis in Egyptian patients especially, those presenting with hepatic disease. It is specific, sensitive and easy to perform method for the rapid diagnosis particularly when more complex laboratory tests are unavailable.

Production of recombinant nucleocapsid protein of Newcastle disease virus in Escherichia coli for a diagnostic ELISA

  • Kim, Hyun-Il;Park, Kyoung-Phil;Park, Chan-Hee;Cho, Hyun-Ah;Yang, Ho-Suk;Hahn, Tae-Wook
    • Korean Journal of Veterinary Research
    • /
    • v.49 no.1
    • /
    • pp.39-44
    • /
    • 2009
  • Transmission of avian viruses both bird-to-bird and from birds to non-avian species is a major health concern. Newcastle disease virus (NDV) is an economically important avian virus that poses substantial risks to the poultry industry. Rapid and sensitive diagnostic methods, such as the enzymelinked immunosorbent assay (ELISA), are required to track such infections. To develop an ELISA for detecting anti-NDV antibody in avian sera, the nucleocapsid protein (NCP) gene of the NDV La Sota strain was cloned and expressed in Escherichia coli and the 513-amino acid recombinant NCP was purified by Ni-NTA affinity chromatography. To evaluate its ability to replace NDV whole virus antigen as a coating antigen, NCP-coated and whole NDV-coated ELISAs were tested and compared using a panel of NDV positive antisera from chickens. Results using purified NCP were highly correlated with those obtained using whole NDV (r= 0.927), demonstrating that recombinant NCP expressed in Escherichia coli is a suitable substitute antigen for whole NDV in a diagnostic ELISA.

Serological Test of Virus disease of Tussah Silkworm. (작잠농병 Virus의 면역학혈청학적 반응)

  • 임종성
    • Journal of Sericultural and Entomological Science
    • /
    • v.6
    • /
    • pp.42-48
    • /
    • 1966
  • Throughout the studies the following experimental results were obtained and so are summarized here. 1) What caused tussah silkworms terrible disease broken ous all over the Korea in 1965, was examined to be “Inclusion body of virus” through microscope. 2) The examined inclusion bodies are easily stained as purple by seller's staining. 3) The proper speed of centrifugation for the purification of inclusion bodies is 1,000 r. p. m for 10 minutes. 4) It is possible, cleanly resulted, to attempt the “Rapid Agglatination Test & Complement Fixation test” with autigen of inclusion bodies. 5) The Anti-polyhedra rabbit serum from antigen of the dilution of 2${\times}$10$\^$6//l$m\ell$ polyhedra made the Ropid Agglutination test possible even with dilution of 1/8 infected pupa blood(antigen).

  • PDF

Clinical Usefulness of Rapid Antigen Test on the Diagnosis of Influenza (인플루엔자 진단을 위한 신속 항원검사의 유용성)

  • Kim, Jae Seon;Choi, Hyon Joo;Ahn, Young Min;Hwang, Young Ok
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.12
    • /
    • pp.1348-1353
    • /
    • 2005
  • Purpose : Influenza is a respiratory disease which prevails widely every year and shows high morbidity and mortality among not only chronic invalids and the old, but also among infants and young children. To prevent community-acquired influenza infection, to facilitate prompt antiviral therapy and to avoid unnecessary use of antibiotics, an easy, rapid diagnostic method for the influenza virus is needed. We evaluated a lateral-flow immunoassay(QuickVue Influenza Test), compared to viral culture. Methods : During two consecutive years from Jan. 2004 to June 2004 and from Feb. 2005 to Jan. 2005, 408 patients who were suffering from fever, cough and/or sore throat and myalgia were enrolled in our study. A total of 408 patients were tested with $QuickVue^{(R)}$(Quidel Co., San Diego, USA) influenza rapid antigen test and virus cultures at the same time. Results : Of the 408 patients tested, children who showed positive results at the virus culture numbered 77; among them, 55(71.4 percent) were type A/H3N2 and 22(28.5 percent) were type B. QuickVue influenza test had a sensitivity of 71.4 percent and a specificity of 95.8 percent. The positive and negative predictive values were 79.7 percent and 93.5 percent, respectively. Conclusion : In our study, this test had comparable high sensitivity and high specificity and many advantages, such as being easy to perform and simple to interpret, and showing rapid results. If rapid influenza antigen tests are widely applied in the clinic, we can begin treatment more rapidly and reduce influenza complications and the abuse of antibiotics.