• Title/Summary/Keyword: Rapid Shutdown

Search Result 9, Processing Time 0.024 seconds

Characteristic Analysis and Configuration of the Protection System to Improve the Safety of the BIPV System (BIPV 시스템의 안전성 향상을 위한 보호시스템 구성 및 특성 분석)

  • Seok-Hwan Cho;Jae-Sub Ko;Dae-Kyong Kim
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.27 no.3
    • /
    • pp.591-599
    • /
    • 2024
  • This paper presents the configuration and characteristic analysis of the protection system to improve the safety of the building integrated photovoltaic(BIPV) system. BIPV is a solar power system installed in buildings. Since the BIPV system is installed in buildings, there is a high risk of electric shock and fire accidents. Therefore, in order to improve the safety of BIPV, a protective system is required to block or quickly detect risk factors. In this paper, as a protection system to improve the safety of the BIPV system, it is composed of a rapid shutdown (RSD) that can quickly separate the PV system to prevent fire and electric shock accidents and a system to detect Arc faults that cause PV system fires. RSD and Arc Fault Detector analyzed the operating characteristics according to each condition and confirmed that the safety of the BIPV system can be improved through this.

Rapid and massive throughput analysis of a constant volume high-pressure gas injection system

  • Ren, Xiaoli;Zhai, Jia;Wang, Jihong;Ren, Ge
    • Nuclear Engineering and Technology
    • /
    • v.51 no.3
    • /
    • pp.908-914
    • /
    • 2019
  • Fusion power shutdown system (FPSS) is a safety system to stop plasma in case of accidents or incidents. The gas injection system for the FPSS presented in this work is designed to research the flow development in a closed system. As the efficiency of the system is a crucial property, plenty of experiments are executed to get optimum parameters. In this system, the flow is driven by the pressure difference between a gas storage tank and a vacuum vessel with a source pressure. The idea is based on a constant volume system without extra source gases to guarantee rapid response and high throughput. Among them, valves and gas species are studied because their properties could influence the velocity of the fluid field. Then source pressures and volumes are emphasized to investigate the volume flow rate of the injection. The source pressure has a considerable effect on the injected volume. From the data, proper parameters are extracted to achieve the best performance of the FPSS. Finally, experimental results are used as a quantitative benchmark for simulations which can add our understanding of the inner gas flow in the pipeline. In generally, there is a good consistency and the obtained correlations will be applied in further study and design for the FPSS.

COVID-19's Rapid Digitalization of Construction Education: Built Environment Instructor Experience in Kwazulu-Natal, South Africa.

  • Mall, Ayesha;Haupt, Theodore C
    • International conference on construction engineering and project management
    • /
    • 2022.06a
    • /
    • pp.476-483
    • /
    • 2022
  • The novel coronavirus pandemic has had a significant impact on society and everyday life. The pandemic imposed a global shutdown leading to many challenges such as the suspension of academic programs at universities. The result of this suspension contributed to the rapid overnight migration of educational activities from traditional face-to-face learning to a virtual environment which until then was unfamiliar to both instructors and students. This study identified the experiences faced by built environment higher education instructors in KwaZulu-Natal, South Africa during this sudden switch to online teaching and learning. This pilot study employed a quantitative research approach to survey instructor experiences on online teaching and learning during a global pandemic. The data was computed and analyzed using IBM Statistical Package for Social Sciences (SPSS) version 27. Descriptive statistics were used to analyze the data collected. The study sample comprised of 20 higher education instructors in the region of the KwaZulu Natal province in South Africa. Findings from the study revealed that instructors faced adaptive challenges with rapidly having to redesign and remodel the mode of academic course delivery and assessments to suit an online platform. Additionally, instructors observed that students faced technological challenges such as connectivity and navigating the online learning management system platforms. The challenges identified by instructors and students can be effectively transformed to opportunities for future learning under the 'new normal'.

  • PDF

Performance test and factor analysis on the performance of shutoff units with the research reactor (연구용 원자로의 정지봉 장치 성능에 미치는 인자 분석과 성능 시험)

  • Kim, Kyoung-Rean;Kim, Seoug-Beom;Ko, Jae-Myoung;Moon, Gyoon-Young;Park, Jong-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.10 no.2 s.41
    • /
    • pp.41-45
    • /
    • 2007
  • The shutoff unit was designed to provide rapid insertion of neutron absorbing material into the reactor core to shutdown the reactor quickly and also to withdraw the absorber slowly to avoid a log-rate trip. Four shutoff units were installed on the HANARO reactor but the half-core test facility was equipped with one shutoff unit. The reactor trip or shutdown is accomplished by four shutoff units by insertion of the shutoff rods. The shutoff rod(SOR) is actuated by a directly linked hydraulic cylinder on the reactor chimney, which is pressurized by a hydraulic pump. The rod is released to drop by gravity, when triplicate solenoid valves are de-energized to vent the cylinder. The hydraulic pump, pipe and air supply system are provided to be similar with the HANARO reactor. The shutoff rod drops for 647mm stroke within 1.13 seconds to shut down the reactor and it is slowly inserted to the full down position, 700mm, with a damping. We have conducted the drop test of the shutoff rod in order to show the performance and the structural integrity of operating system of the shutoff unit. The present paper deals with the 647mm drop time and the withdrawal time according to variation of the pool water temperature, the water level and the core flow.

Drop Time Evaluation for SMART Control Rod Assembly (스마트 제어봉집합체의 낙하시간 평가)

  • Kim, Kyoung-Rean;Jang, Ki-Jong;Park, Jin-Seok;Lee, Won-Jae
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.2
    • /
    • pp.25-28
    • /
    • 2011
  • The control rod assemblies do freely fall into the reactor core by the gravity from the control rod drive mechanism. In order to achieve a rapid shutdown and control the reactor power, it is required to insert control rod assemblies as soon as possible. In this paper, we evaluated the drop time and flow characteristics caused around guide tube for SMART(System-integrated modular advanced reactor) control rod assembly. Numerical analyses are carried out with FLUENT program of computational fluid dynamics. This study results show that the drop time of the control rod assembly in the operating condition of SMART is more 20 percent rapidly than the drop time of the room temperature and ambient atmosphere condition.

Study on an On-line Measurement System of Corrosion Rate by Linear Polarization Resistance (분극저항에 의한 온라인 부식속도 측정 시스템에 관한 연구)

  • Moon, Jeon Soo;Lee, Jae Kun;Lee, Jae Bong;Park, Pyl Yang
    • Corrosion Science and Technology
    • /
    • v.11 no.4
    • /
    • pp.135-140
    • /
    • 2012
  • The linear polarization resistance method is one of the widely used techniques for the corrosion rate monitoring in the water circulating systems of plants. The measurement is simple and rapid, so that a continuous on-line monitoring is possible without any shutdown of plants. A 2-electrode polarization corrosion rate measurement system was installed in a laboratory using a data acquisition board and PC. The signal processing parameters were optimized for the accurate corrosion rate measurement, and the polarization resistance was compensated with the solution resistance measured by the high frequency sine wave signal of an output channel. The precision of corrosion rate data was greatly improved by removing the initial noise signals on measuring the polarization resistance.

Development of Water Hammer Simulation Model for Safety Assessment of Hydroelectric Power Plant (수력발전설비의 안전도 평가를 위한 수충격 해석 모형 개발)

  • Nam, Myeong Jun;Lee, Jae-Young;Jung, Woo-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.1
    • /
    • pp.760-767
    • /
    • 2020
  • Sustainable growth of hydroelectric power plants is expected in consideration of climate change and energy security. However, hydroelectric power plants always have a risk of water hammer damage, and safety assurance is very important. The water hammer phenomenon commonly occurs during operations such as rapid opening and closing of the valves and pump/turbine shutdown in pipe systems, which is more common in cases of emergency shutdown. In this study, a computational numerical model was developed using the MOC-FDM scheme to reflect the mechanism of water hammer occurrence. The proposed model was implemented in boundary conditions such as reservoir, pipeline, valve, and pump/turbine conditions and then applied to simulate hypothetical case studies. The analysis results of the model were verified using the analysis results at the main points of the pipe systems. The model produced reasonably good performance and was validated by comparison with the results of the SIMSEN package model. The model could be used as an efficient tool for the safety assessment of hydroelectric power plants based on accurate prediction of transient behavior in the operation of hydropower facilities.

Improving Accident Tolerance of Nuclear Fuel with Coated Mo-alloy Cladding

  • Cheng, Bo;Kim, Young-Jin;Chou, Peter
    • Nuclear Engineering and Technology
    • /
    • v.48 no.1
    • /
    • pp.16-25
    • /
    • 2016
  • In severe loss of coolant accidents (LOCA), similar to those experienced at Fukushima Daiichi and Three Mile Island Unit 1, the zirconiumalloy fuel claddingmaterials are rapidlyheateddue to nuclear decay heating and rapid exothermic oxidation of zirconium with steam. This heating causes the cladding to rapidly react with steam, lose strength, burst or collapse, and generate large quantities of hydrogen gas. Although maintaining core cooling remains the highest priority in accident management, an accident tolerant fuel (ATF) design may extend coping and recovery time for operators to restore emergency power, and cooling, and achieve safe shutdown. An ATF is required to possess high resistance to steam oxidation to reduce hydrogen generation and sufficient mechanical strength to maintain fuel rod integrity and core coolability. The initiative undertaken by Electric Power Research Institute (EPRI) is to demonstrate the feasibility of developing an ATF cladding with capability to maintain its integrity in $1,200-1,500^{\circ}C$ steam for at least 24 hours. This ATF cladding utilizes thin-walled Mo-alloys coated with oxidation-resistant surface layers. The basic design consists of a thin-walled Mo alloy structural tube with a metallurgically bonded, oxidation-resistant outer layer. Two options are being investigated: a commercially available iron, chromium, and aluminum alloy with excellent high temperature oxidation resistance, and a Zr alloy with demonstratedcorrosionresistance.Asthese composite claddings will incorporate either no Zr, or thin Zr outer layers, hydrogen generation under severe LOCA conditions will be greatly reduced. Key technical challenges and uncertainties specific to Moalloy fuel cladding include: economic core design, industrial scale fabricability, radiation embrittlement, and corrosion and oxidation resistance during normal operation, transients, and severe accidents. Progress in each aspect has been made and key results are discussed in this document. In addition to assisting plants in meeting Light Water Reactor (LWR) challenges, accident-tolerant Mo-based cladding technologies are expected to be applicable for use in high-temperature helium and molten salt reactor designs, as well as nonnuclear high temperature applications.

A Study on Protection Coordination Algorithm for Separating Fault Section in LVDC Distribution System (LVDC 배전계통에 있어서 사고구간분리 보호협조 알고리즘에 관한 연구)

  • Kang, Min-Kwan;Lee, Hu-Dong;Tae, Dong-Hyun;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.1
    • /
    • pp.768-776
    • /
    • 2021
  • Current protection-coordination methods use the reverse time characteristics of the T-C curve, which is not effective for a LVDC distribution system because the protective operation time of converters and DC circuit breakers is much faster than AC protection devices. Therefore, an algorithm is proposed for fault-section isolation using the fault current slope to minimize the blackout region and coordinate between converters and protection devices in a rapid and accurate manner. The method deals with the slope characteristics of a fault current, which may depend on the fault location in an LVDC distribution system. Thus, an LVDC distribution system can be operated in a stable manner by isolating the fault section selectively before the shutdown of the main converter using slope characteristics, which change in proportion to the line impedance and fault location. A 1.5-kV LVDC distribution system was modeled to verify the effectiveness of the proposed algorithm using PSCAD/EMTDC. The system is composed of a distribution substation, LVDC converter, and distribution lines. The simulation results confirm that the proposed algorithm is a useful tool for minimizing the fault section in an LVDC distribution system.