• Title/Summary/Keyword: Rank Reduction

Search Result 108, Processing Time 0.02 seconds

Options Manageing for Radioactive Metallic Waste From the Decommissioning of Kori Unit 1 (고리1호기 해체시 발생할 방사성금속폐기물 관리 옵션 연구)

  • Kessel, David S.;Kim, Chang-Lak
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.15 no.2
    • /
    • pp.181-189
    • /
    • 2017
  • The purpose of this paper is to evaluate several leading options for the management of radioactive metallic waste against a set of general criteria including safety, cost effectiveness, radiological dose to workers and volume reduction. Several options for managing metallic waste generated from decommissioning are evaluated in this paper. These options include free release, controlled reuse, and direct disposal of radioactive metallic waste. Each of these options may involve treatment of the metal waste for volume reduction by physical cutting or melting. A multi-criteria decision analysis was performed using the Analytic Hierarchy Process (AHP) to rank the options. Melting radioactive metallic waste to produce metal ingots with controlled reuse or free release is found to be the most effective option.

Comparison of the Quality of Various Polychromatic and Monochromatic Dual-Energy CT Images with or without a Metal Artifact Reduction Algorithm to Evaluate Total Knee Arthroplasty

  • Hye Jung Choo;Sun Joo Lee;Dong Wook Kim;Yoo Jin Lee;Jin Wook Baek;Ji-yeon Han;Young Jin Heo
    • Korean Journal of Radiology
    • /
    • v.22 no.8
    • /
    • pp.1341-1351
    • /
    • 2021
  • Objective: To compare the quality of various polychromatic and monochromatic images with or without using an iterative metal artifact reduction algorithm (iMAR) obtained from a dual-energy computed tomography (CT) to evaluate total knee arthroplasty. Materials and Methods: We included 58 patients (28 male and 30 female; mean age [range], 71.4 [61-83] years) who underwent 74 knee examinations after total knee arthroplasty using dual-energy CT. CT image sets consisted of polychromatic image sets that linearly blended 80 kVp and tin-filtered 140 kVp using weighting factors of 0.4, 0, and -0.3, and monochromatic images at 130, 150, 170, and 190 keV. These image sets were obtained with and without applying iMAR, creating a total of 14 image sets. Two readers qualitatively ranked the image quality (1 [lowest quality] through 14 [highest quality]). Volumes of high- and low-density artifacts and contrast-to-noise ratios (CNRs) between the bone and fat tissue were quantitatively measured in a subset of 25 knees unaffected by metal artifacts. Results: iMAR-applied, polychromatic images using weighting factors of -0.3 and 0.0 (P-0.3i and P0.0i, respectively) showed the highest image-quality rank scores (median of 14 for both by one reader and 13 and 14, respectively, by the other reader; p < 0.001). All iMAR-applied image series showed higher rank scores than the iMAR-unapplied ones. The smallest volumes of low-density artifacts were found in P-0.3i, P0.0i, and iMAR-applied monochromatic images at 130 keV. The smallest volumes of high-density artifacts were noted in P-0.3i. The CNRs were best in polychromatic images using a weighting factor of 0.4 with or without iMAR application, followed by polychromatic images using a weighting factor of 0.0 with or without iMAR application. Conclusion: Polychromatic images combined with iMAR application, P-0.3i and P0.0i, provided better image qualities and substantial metal artifact reduction compared with other image sets.

Comparing Chewable and Manual Toothbrushes for Reducing Dental Plaque: A Pilot Study

  • Jeong, Moon-Jin;Shin, Hye-Sun;Jeong, Soon-Jeong;Lim, Do-Seon
    • Journal of dental hygiene science
    • /
    • v.17 no.3
    • /
    • pp.267-274
    • /
    • 2017
  • This study aimed to compare the effectiveness of chewable toothbrush and manual toothbrush and provide basic data for recommendation of the chewable toothbrush in specific groups and situations. A total of 20 subjects participated in this study (rolling method, 10; non-rolling method, 10). After professional prophylaxis, participants used the manual toothbrush to brush their teeth for 3 minutes. After a 7-day wash-out period, participants used the chewable toothbrush according to the manufacturer's instructions. Pre- and post-plaque indexing of the teeth was performed. The dental plaque index was assessed using the Turesky Modification of the Quigley-Hein Plaque Index (TMQHPI) for amount of plaque and Silness-Loe Plaque Index (SLPI) for plaque thickness. The difference between pre- and post-dental plaque index was analyzed using a paired t-test and the Wilcoxon signed-rank test. The Mann-Whitney U test was also used to compare the dental plaque index reduction rates. The dental plaque index differed significantly between the chewable toothbrush and the manual toothbrush. The TMQHPI reduction rate was significantly different between the rolling and non-rolling method groups for the manual toothbrush but not the chewable toothbrush. The difference in SLPI reduction rate between the rolling and non-rolling method groups was significant for the manual toothbrush but not for the chewable toothbrush. Differences in the dental plaque index reduction rates between the chewable and manual toothbrushes were not significant in the non-rolling method group. The results of this study showed higher reduction rates in dental plaque with manual toothbrush use than with chewable toothbrush use. However, the non-rolling method group did not show statistically significant differences according to toothbrush type. The present study showed that a chewable toothbrush can be an alternative to a manual toothbrush for individuals who have difficulty using the generally recommended rolling method.

Ultrasonic Effect on the Extraction of Ash-free coal from Low Rank Coal (저등급 석탄으로부터 초청정석탄의 추출과 초음파의 영향)

  • Lee, Sihyun;Kim, Sangdo;Jeong, Soonkwan;Rhim, Youngjun;Kim, Daehun;Woo, Kwangjae
    • Korean Chemical Engineering Research
    • /
    • v.46 no.3
    • /
    • pp.555-560
    • /
    • 2008
  • Extraction was performed to prepare ash-free coal from low rank coal under the temperature of $200-430^{\circ}C$ and initial pressure of 0.1MPa. Three kinds of coal samples with different rank were used and N-methyl-2-pyrrolidinone(NMP, polar), 1-methyl naphthalene(I-MN, non-polar), Light Cycle Oil(LCO, non-polar) were used as solvents. Results showed that higher extraction yield could be obtained with NMP than with 1-MN and LCO, but the ash concentration shows minimun in the case of 1-MN. Three operation modes were compared, that is, idle, agitation and ultrasonic extraction mode. From the results, it was found that the extraction yield and ash concentration were 70.09% and 1.03% under the agitation mode, 80.7% and 0.76% under the ultrasonic operation mode respectively in the case of NMP used at the temperature of $350^{\circ}C$. Similar results were obtained with 1-MN. Effect of ultrasonic on the extraction was estimated as 15-20% increase in the yields and 26% reduction in the ash concentration.

A comparative study of the improvement after different self-assessment methods of tooth preparation (치아 삭제의 다른 자가 평가 방법 후 개선에 대한 비교 연구)

  • Kim, JungHan;Son, Keunbada;Lee, Kyu-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.35 no.4
    • /
    • pp.220-227
    • /
    • 2019
  • Purpose: The purpose of this study was to compare the degree of tooth preparation abilities of students according to three self-assessment methods. Materials and Methods: forty-eight sophomores in Kyungpook National University College of Dentistry were divided into three experimental groups. Students performed tooth preparation of the left mandibular first molar for full gold crown. They performed self-assessment using the three methods (visual, digital, and putty index self-assessment group), and reperformed tooth preparation. An intraoral scanner was used to scan each tooth model (prepared tooth and unprepared tooth), and data were acquired in standard tessellation language (STL) file format. The STL files of prepared tooth and unprepared tooth were superimposed using the 3-dimensional analysis software (Geomagic control X). And the reduction amount was measured. In the statistical analysis, all values of reduction amount were analyzed with the Wilcoxon signed rank test and Kruskal-Wallis test (α = 0.05). Results: The three self-assessment methods showed statistically significant differences (P < 0.001). The putty index self-assessment group showed the highest reduction in error than the digital self-assessment method. Conclusion: Within limitations of this study, students showed significant differences in improvement of tooth preparation ability according to the three self-evaluation methods.

Single-Channel Seismic Data Processing via Singular Spectrum Analysis (특이 스펙트럼 분석 기반 단일 채널 탄성파 자료처리 연구)

  • Woodon Jeong;Chanhee Lee;Seung-Goo Kang
    • Geophysics and Geophysical Exploration
    • /
    • v.27 no.2
    • /
    • pp.91-107
    • /
    • 2024
  • Single-channel seismic exploration has proven effective in delineating subsurface geological structures using small-scale survey systems. The seismic data acquired through zero- or near-offset methods directly capture subsurface features along the vertical axis, facilitating the construction of corresponding seismic sections. However, substantial noise in single-channel seismic data hampers precise interpretation because of the low signal-to-noise ratio. This study introduces a novel approach that integrate noise reduction and signal enhancement via matrix rank optimization to address this issue. Unlike conventional rank-reduction methods, which retain selected singular values to mitigate random noise, our method optimizes the entire singular value spectrum, thus effectively tackling both random and erratic noises commonly found in environments with low signal-to-noise ratio. Additionally, to enhance the horizontal continuity of seismic events and mitigate signal loss during noise reduction, we introduced an adaptive weighting factor computed from the eigenimage of the seismic section. To access the robustness of the proposed method, we conducted numerical experiments using single-channel Sparker seismic data from the Chukchi Plateau in the Arctic Ocean. The results demonstrated that the seismic sections had significantly improved signal-to-noise ratios and minimal signal loss. These advancements hold promise for enhancing single-channel and high-resolution seismic surveys and aiding in the identification of marine development and submarine geological hazards in domestic coastal areas.

A Plot Scale Experiment to Analysis the NPS Reduction by Silt Fence and Vegetated Ridge for Non-Irrigated Cropland (실트펜스와 식생밭두렁 적용을 통한 밭 비점오염 저감효과 분석을 위한 포장실험 연구)

  • Kim, Sung-Jae;Park, Tae-Yang;Kim, Sung-Min;Jang, Jeong-Ryeol;Kim, Sang-Min
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.54 no.4
    • /
    • pp.19-27
    • /
    • 2012
  • The objective of this study was to test the pollutant reduction effect by the silt fence and vegetated ridge through field monitoring. The experiment plots were established with two replication and three treatments. Each plot was designed with 5 m width, 22 m length, and 3 % slope. Flumes with the floating type stage gages were installed at the outlet of each plot to monitor the runoff. For a rainfall monitoring, tipping bucket rain gage was installed within the experiment site. Cultivated crops were spring daikon and autumn chinese cabbage. Analysis of variance (ANOVA) indicated that the water quality concentration from three experiment plots were not significantly different in 5 % of significant level. The monitoring results showed that the average pollution loads reduced by silt fence compared to control were SS 75.33 %, TN 40.87 %, TP 56.58 %, BOD 52.12 %, COD 36.07 %, TOC 34.99 %; by vegetated ridge compard to control were SS 65.27 %, TN 81.80 %, TP 54.26 %, BOD 67.09 %, COD 46.55 %, TOC 43.30 %. Analysis of Spearman's rank correlation coefficient showed that BOD-SS and SS-Turbidity were highly related at the silt fence and vegetated ridge plots. In all plots, SS-Turbidity and TP-TN relations were relatively high. The monitoring results showed that the silt fence and vegetated ridge were effect method to reduce the pollutant loads from the field runoff. Long-term monitoring is required to obtain more quantitative reduction effect for diverse crops and to increase the reliability of results.

Internal evaluation of provisional restorations according to the dental CAD/CAM manufacturing method : Three-dimensional superimpositional analysis (치과 CAD/CAM 가공방식에 따른 임시보철물의 내면 적합도 : 3차원 중첩 분석)

  • Kim, Jae-Hong;Kim, Ki-Baek
    • Journal of Technologic Dentistry
    • /
    • v.41 no.2
    • /
    • pp.81-86
    • /
    • 2019
  • Purpose: The purpose of the present study was to compare the internal fit of two different temporary restorations fabricated by dental CAD/CAM system and to evaluate clinical effectiveness. Methods: Composite resin tooth of the maxillary first molar was prepared as occlusal reduction(2.0mm), axial reduction(1mm offset), vertical angle(6 degree) and chamfer margin for a temporary crown and duplicated epoxy die was fabricated. The epoxy dies were used to fabricate provisional restorations by CAD/CAM milling technique or 3D-printing technique. The inner data from all crowns were superimposed on the master die file in the 'best-fit alignment' method using 3D analysis software. Statistical analysis was performed using a Wilcoxon's rank sum test for differences between groups. Results: It showed that the internal RMS(Root Mean Square) values of the additive group were significantly larger than those of other group. No significant differences in internal discrepancies were observed in the temporary crowns among the 2 groups with different manufacturing method. Conclusion: All the groups had the internal fit within the clinical acceptable range (< $50{\mu}m$). The continuous research in the future to be applied clinically for the adaptation of additive manufacturing technique are needed.

Frequency Estimation of Multiple Sinusoids From MR Method (MR 방법으로부터 다단 정현파의 주파수 추정)

  • 안태천;탁현수;이종범
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.29B no.2
    • /
    • pp.18-26
    • /
    • 1992
  • MR(Model Reduction) is presented in order to estimate the frequency of multiple sinusoids from the finite noisy data with the white or colored noises. MR, using the reduced rank models, is designed, appling the approximation of linear system to LP(Linear Prediction). The MR method is analyzed. Monte-carlo simulations are conducted for MR and Lp. The results are compared with in terms of mean, root-mean square and relative bias. MR eliminates effectevely the extremeous and exceptional poles appearing in LP and improves the accuracy of LP. Especially, MR gives promising results in short noisy measurements, low SNR's and colored noises. Power spectral density and angular frequency position are showed by figures, for examples. Finally, the new method is utilized to the communication and biomedical systems estimating the characteristics of the signal and the system identification modelling the dynamic systems from experimental data.

  • PDF

Robust $L_2$Optimization for Uncertain Systems

  • Kim, Kyung-Soo;Park, Youngjin
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1995.10a
    • /
    • pp.348-351
    • /
    • 1995
  • This note proposes a robust LQR method for systems with structured real parameter uncertainty based on Riccati equation approach. Emphasis is on the reduction of design conservatism in the sense of quadratic performance by utilizing the uncertainty structure. The class of uncertainty treated includes all the form of additive real parameter uncertainty, which has the multiple rank structure. To handle the structure of uncertainty, the scaling matrix with block diagonal structure is introduced. By changing the scaling matrix, all the possible set of uncertainty structures can be represented. Modified algebraic Riccati equation (MARE) is newly proposed to obtain a robust feedback control law, which makes the quadratic cost finite for an arbitrary scaling matrix. The remaining design freedom, that is, the scaling matrix is used for minimizing the upper bound of the quadratic cost for all possible set of uncertainties within the given bounds. A design example is shown to demonstrate the simplicity and the effectiveness of proposed method.

  • PDF