• Title/Summary/Keyword: Range resolved

Search Result 250, Processing Time 0.023 seconds

Construction and Performance Characterization of Time-correlated Single Photon Counting System having Picosecond Resolution (피코초 분해능의 시간 상관 단광자 계수 장치 구성 및 동작 특성)

  • 이민영;김동호
    • Korean Journal of Optics and Photonics
    • /
    • v.5 no.1
    • /
    • pp.90-99
    • /
    • 1994
  • Picosecond time-correlated single photon counting system and time-resolved luminescence spectrometer were constructed, employing a mode-locked picosecond laser, fast electronics, and microchannel plate tube. It has been shown that the instrument response function critically depends on laser pulse shape, timing jitter and walk of the electronics, and characteristics of detector and amplifier. Correcting time dispersion in the optical system, the best instrument response function obtained appears to be 25 ps, which made it possible to measure the luminescence lifetime with less than 10 ps resolution in the picosecond to microsecond range. range.

  • PDF

Complex Conjugate Resolved Retinal Imaging by One-micrometer Spectral Domain Optical Coherence Tomography Using an Electro-optical Phase Modulator

  • Fabritius, Tapio E.J.;Makita, Shuichi;Yamanari, Masahiro;Myllyla, Risto A.;Yasuno, Yoshiaki
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.2
    • /
    • pp.111-117
    • /
    • 2011
  • Full-range spectral domain optical coherence tomography (SD-OCT) with a 1-${\mu}m$ band light source is shown here. The phase of the reference beam is continuously stepped while the probing beam scans the sample laterally (B-scan). The two dimensional spectral interferogram obtained is processed by a Fourier transform method to obtain a complex spectrum leading to a full-range OCT image. A detailed mathematical explanation of the complex conjugate resolving method utilized is provided. The system's measurement speed was 7.96 kHz, the measured axial resolution was $9.6{\mu}m$ in air and the maximum sensitivity 99.4 dB. To demonstrate the effect of mirror image elimination, In vivo human eye pathology was measured.

Near-IR Spectral Features of Haze Particles in the Atmosphere of Titan

  • Kim, Sang Joon
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.1
    • /
    • pp.62.1-62.1
    • /
    • 2013
  • The Cassini/Visual Infrared Mapping Spectrometer (VIMS) observed the sun through the atmosphere of Titan, and provided vertically-resolved 63 spectra from 49 km to 987 km for the 1 - 5 micron range (Bellucci, 2008). Bellucci et al. (2009) analyzed selected spectral ranges where the band absorptions of $CH_4$ and CO are strong by constructing synthetic spectra including $CH_4$ and CO lines, but without including haze absorptions in their synthetic spectra. Kim et al. (2011) and Sim et al. (2013) were able to extract detailed spectral features of fundamental (Dv = 1) and overtone (Dv = 2) bands of the haze from the VIMS spectra by excluding the adjacent influences of strong $CH_4$ absorptions using a radiative transfer program, which includes effects of absorption and emission of lines of these molecules, and absorption and scattering of haze particles. In this presentation, we extend our detailed analyses to other remaining wavelengths in order to provide the spectral characteristics of the Titanian haze for the entire 1 - 5 micron range and to identify any additional haze spectral features and an unidentified feature near 4.3 microns reported by Bellucci et al. (2009).

  • PDF

Prosodic aspects of ambiguous sentences in Korean produced by Chinese speakers (한국어 중의성 문장에 대한 중국인학습자들의 발화양상)

  • Yune, Youngsook
    • Phonetics and Speech Sciences
    • /
    • v.9 no.2
    • /
    • pp.61-68
    • /
    • 2017
  • The aim of this study is to investigate the prosodic aspects of ambiguous sentences in Korean produced by Chinese Korean Learners (L1: Chinese, L2: Korean). In Korean, sentence ambiguity can be caused by homonym or syntactically ambiguous structure. In spoken language however all ambiguity can be resolved by different prosodic features according to the meaning that they transmit. In this study we examined whether Chinese Korean Leaners also distinguish, in production, ambiguous sentences on the basis of prosodic characteristics. For this study 4 Korean natives speakers and 10 advanced Chinese Korean learners participated in the production test. The material analysed constituted 10 Korean sentences in which 6 sentences are lexically ambiguous and 4 sentences contain structural ambiguity. The results show that Korean native speakers produced ambiguous sentences by different prosodic structure depending on their semantic and syntactic structure. Chinese speakers also show distinct prosodic structure for different ambiguous sentences in most cases. But in the phonetic realization, the internal pitch range was greater for Korean native speakers than Chinese learners.

A Numerical Simulation of Aerodynamic Focusing of Nanoparticles in a Wide Range of 30nm~3000nm (30nm~3000nm 광범위 직경 입자의 공기역학적 집속에 대한 수치해석)

  • Lee, Kwang-Sung;Lee, Donggeun
    • Particle and aerosol research
    • /
    • v.7 no.4
    • /
    • pp.123-130
    • /
    • 2011
  • Previous designs of conventional aerodynamic lenses have a limitation of narrow range of focusable particle size, e.g. 30 to 300nm or 3 to 30nm. To enlarge the focusable size range to 30-3000nm, it is necessary to avoid a significant loss of particles larger than 300nm inside the lenses. From numerical simulations on size-resolved particle trajectories, we confirmed that the traveling losses of such large particles could be avoided only when the radial position of particles approaching the orifice lens was near the lens axis. Hence, we designed the lens system consisting of a converging-diverging nozzle and 7 orifices to fulfill the requirement. In particular, the orifices were aligned in a way that their diameters were descending and ascending to the downstream. As a result, 30-2800nm particles can be focused to the particle beam of 0.2mm or less in radius with above 85% transmission efficiency. Even $10{\mu}m$ particles can be focused with 74% of transmission efficiency.

Color Noise Reduction Method in Non-constant Luminance Signal for High Dynamic Range Video Service

  • Lee, Jinho;Jun, Dongsan;Kang, Jungwon;Ko, Hyunsuk;Kim, Hui Yong;Choi, Jin Soo
    • ETRI Journal
    • /
    • v.38 no.5
    • /
    • pp.858-867
    • /
    • 2016
  • A high dynamic range (HDR) video service is an upcoming issue in the broadcasting industry. For compatibility with legacy devices receiving a non-constant luminance (NCL) signal, new tools supporting an HDR video service are required. The current pre-processing chain of HDR video can produce color noise owing to the chroma component down-sampling process for video encoding. Although a luma adjustment method has been proposed to solve this problem, some disadvantages still remain. In this paper, we present an adaptive color noise reduction method for an NCL signal of an HDR video service. The proposed method adjusts the luma component of an NCL signal adaptively according to the information of the luma component from a constant luminance signal and the level of color saturation. Experiment results show that the color noise problem is resolved by applying our proposed method. In addition, the speed of the pre-processing is increased more than two-fold compared to a previous method.

The Characteristics of the Aerosol Number Concentration in Jeju Area During Asian Dust Events (황사 시 제주지역 에어로졸의 수농도 특성)

  • Kang, Chang-Hee;Hu, Chul-Goo
    • Journal of Environmental Science International
    • /
    • v.22 no.3
    • /
    • pp.347-358
    • /
    • 2013
  • The aerosol number concentration have measured with an aerodynamic particle sizer spectrometer(APS) at Gosan in Jeju Island, which is known as background area in Korea, from March 2010 to February 2011. The obtained results of asian dust events and non-asian dust period have been compared. The results show that the entire averaged aerosol number concentration from APS measurement during asian dust events and non-asian dust period are about 341 particles/$cm^3$ and 240 particles/$cm^3$, respectively. During asian dust events, the number concentration in small size ranges(${\leq}0.4{\mu}m$) are similar to non-asian dust period, however, those in large size ranges(${\geq}0.7{\mu}m$) are very higher than non-asian dust period. The contributions of the size resolved number concentration(23 channel in $0.25{\sim}10.0{\mu}m$) to total number concentration in that range are dramatically decreased with increased particle size. The contributions of smaller size ranges(${\leq}0.4{\mu}m$) during asian dust events are very low compared with non-asian dust period, on the other hand, those of larger size ranges(${\geq}0.4{\mu}m$) are higher than non-asian dust period. The number concentration in each size range are strongly correlated with the concentration in adjacent size range. And the total aerosol number concentration are depended on the number concentration in range of smaller than $0.58{\mu}m$ during non-asian dust period and asian dust events. On the other hand, $PM_{10}$ mass concentration has mainly affected with the number concentration in range of smaller than $1.0{\mu}m$ during non-asian dust period, however, during asian dust events, the mass concentration has mainly affected with the number concentration in range of $0.65{\sim}3.0{\mu}m$.

Glue Embolization of Lymphopseudoaneurysm for Chylous Ascites after Retroperitoneal Surgery

  • Lyo Min Kwon;Saebeom Hur;Chang Wook Jeong;Hwan Jun Jae;Jin Wook Chung
    • Korean Journal of Radiology
    • /
    • v.22 no.3
    • /
    • pp.376-383
    • /
    • 2021
  • Objective: To assess the safety and efficacy of lymphopseudoaneurysm (LPA) glue (n-butyl cyanoacrylate [NBCA]) embolization in the management of chylous ascites after retroperitoneal surgery. Materials and Methods: A retrospective analysis from January 2014 to October 2018 was performed in six patients (4 females and 2 males; mean age, 45.3 ± 14.2 years; range, 26-61 years) who underwent LPA embolization for chylous ascites developing after retroperitoneal surgery involving the perirenal space (four donor nephrectomies, one partial nephrectomy, and one retroperitoneal lymphadenectomy). After placing a percutaneous drainage catheter into the LPA or adjacent lymphocele, embolization was performed by filling the LPA itself with a mixture of glue and Lipiodol (Guerbet). Results: Daily drainage from percutaneously placed drains exceeded 300 mL/day despite medical and surgical treatment (volume: mean, 1173 ± 1098 mL; range, 305-2800 mL). Intranodal lymphangiography was performed in four of the six patients and revealed leakage in 2 patients. Percutaneous embolization of the LPA was successful in all patients using an NBCA and Lipiodol mixture in a ratio of 1:1-1:2 (volume: mean, 4.3 ± 1.1 mL; range, 3-6 mL). Chylous ascites was resolved and the drainage catheter was removed in all patients within 4 days after the procedure (mean, 2.0 ± 1.8 days; range, 0-4 days). No procedure-related complications or recurrence of chylous ascites occurred during a mean follow-up period of 37.3 months (range, 21.1-48.4 months). Conclusion: Glue embolization of LPA has the potential to be a feasible and effective treatment method for the management of chylous ascites after retroperitoneal surgery.

A case of regression of atypical dense deposit disease without C3 deposition in a child

  • Kim, Min-Sun;Hwang, Pyoung-Han;Kang, Mung-Jae;Lee, Dae-Yeol
    • Clinical and Experimental Pediatrics
    • /
    • v.53 no.7
    • /
    • pp.766-769
    • /
    • 2010
  • Dense deposit disease (DDD) is a rare disorder characterized by the deposition of abnormal electron-dense material within the glomerular basement membrane of the kidneys. The diagnosis is made in most patients between 5 and 15 years of age, and within 10 years, approximately half of the affected patients progress to end-stage renal disease. We report a rare case of regressive DDD without C3 deposition after steroid therapy in an 11-year-old boy. The patient presented with edema, gross hematuria, and nephrotic-range proteinuria. Laboratory testing revealed a serum creatinine level of 1.17 mg/dL, albumin level of 2.3 g/dL, and serum C3 level of 125 mg/dL (range 90-180 mg/dL). The results of the renal biopsy were consistent with DDD without C3 deposition. After 6 weeks of steroid therapy, the nephrotic syndrome completely resolved. The follow-up renal biopsy showed a significant reduction in mesangial proliferation and disappearance of electron-dense deposits in the GBM.

Efficiency Enhancement of Wireless Power Transfer with Optimum Coupling Mechanism for Mid-range Operation

  • Anowar, Tanbir Ibne;Kumar, Narendra;Ramiah, Harikrishnan;Reza, Ahmed Wasif
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.4
    • /
    • pp.1556-1565
    • /
    • 2017
  • This paper depicts the design, implementation and analysis of efficient resonant based wireless power transfer (WPT) technique using three magnetic coupled coils. This work is suitable for mid ranged device due to small form factor while minimizing the loading effect. A multi turned loop size resonator is exploited for both the transmitter and receiver for longer distance. In this paper, class-E power amplifier (class-E PA) is introduced with an optimum power tracking mechanism of WPT system to enhance the power capability at mid-range with a flat gain. A robust method of finding optimum distance is derived with an experimental analysis of the designed system. In this method, the load sensitive issue of WPT is resolved by tuning coupling coefficient at considerable distances. Our designed PA with a drain efficiency of 77.8% for a maximum output of 5W is used with adopted tuning technique that improves the overall WPT system performance by 3 dB at various operating points.