• Title/Summary/Keyword: Range profile image

Search Result 57, Processing Time 0.023 seconds

Optical Lens Design of Image Sensor (이미지 센서용 광학렌즈설계)

  • Lee, Chan-Ku;Lee, Su-Dae;Joung, Maeng-Sig
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.2
    • /
    • pp.99-103
    • /
    • 2003
  • This paper presents lens optimization of the resolution and the distortion for a four-element lens design. In order to have compact optical system, we used the tele-photo type lens composed of a positive and a negative power elements instead of retro-focus lens. The specifications of optical lens design are the focal length of 7.2 mm, the F/number of 2.8 and the field angle of $54.7^{\circ}C$. The MTF values are higher than 0.5 in the spatial frequency range up to 110 lp/mm for all of the designed object heights. Also, it is expected to fulfill all the requirements of a digital still camera lens and especially suited for building low-cost, compact digital cameras because of the low-profile property of the lens design.

  • PDF

HU Threshold Value for IV Catheter Fragment in Peripheral Vein of Volume Rendering 3D MDCT Imaging (정맥 내의 IV 카테터 조각을 3D MDCT 볼륨렌더링 영상으로 구현하기 위한 HU 임계치)

  • Jang, Keun-Jo;Kweon, Dae-Cheol
    • The Journal of the Korea Contents Association
    • /
    • v.7 no.4
    • /
    • pp.206-212
    • /
    • 2007
  • To evaluate the HU value of the IV catheter fragment of CT on the accuracy and size in the peripheral vein. Pilot study of profile and table functions on PC by software was calculated of HU value of IV catheter fragment. This study demonstrates the utility of volume rendering technique to localize a small, subtle IV catheter, which can easily be reformatted of MDCT reformations. IV catheter fragment optimal image described as threshold range. Volume rendering of HU using a MDCT is an excellent method for evaluation the IV catheter fragment in three dimension.

Face Detection for Cast Searching in Video (비디오 등장인물 검색을 위한 얼굴검출)

  • Paik Seung-ho;Kim Jun-hwan;Yoo Ji-sang
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.10C
    • /
    • pp.983-991
    • /
    • 2005
  • Human faces are commonly found in a video such as a drama and provide useful information for video content analysis. Therefore, face detection plays an important role in applications such as face recognition, and face image database management. In this paper, we propose a face detection algorithm based on pre-processing of scene change detection for indexing and cast searching in video. The proposed algorithm consists of three stages: scene change detection stage, face region detection stage, and eyes and mouth detection stage. Experimental results show that the proposed algorithm can detect faces successfully over a wide range of facial variations in scale, rotation, pose, and position, and the performance is improved by $24\%$with profile images comparing with conventional methods using color components.

Analysis of Target Identification Performances Using Bistatic ISAR Images (바이스태틱 ISAR 영상을 이용한 표적식별 성능 분석)

  • Lee, Seung-Jae;Lee, Seong-Hyeon;Kang, Min-Seok;Yang, Eunjung;Kim, Kyung-Tae
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.6
    • /
    • pp.566-576
    • /
    • 2016
  • Inverse synthetic aperture radar(ISAR) image generated from bistatic radar(Bi-ISAR) represents two-dimensional scattering distribution of a target, and the Bi-ISAR can be used for bistatic target identification. However, Bi-ISAR has large variability in scattering mechanisms depending on bistatic configurations and do not represent exact range-Doppler information of a target due to inherent distortion. Thus, an efficient training DB construction is the most important factor in target identification using Bi-ISARs. Recently, a database construction method based on realistic flight scenarios of a target, which provides a reliable identification performance for the monostatic target identification, was applied to target identification using high resolution range profiles(HRRPs) generated from bistatic radar(Bi-HRRPs), to construct efficient training DB under bistatic configurations. Consequently, high identification performance was achieved using only small amount of training Bi-HRRPs, when the target is a considerable distance away from the bistatic radar. Thus, flight scenarios based training DB construction is applied to target identification using Bi-ISARs. Then, the capability and efficiency of the method is analyzed.

Characteristics of Shear Layer Vortices in Crossflow Jets According to the Inlet Conditions (초기조건변화에 따른 횡단류 제트 유동의 전단층와류 거동 특성)

  • Kim, Gyeong-Cheon;Kim, Sang-Gi;Yun, Sang-Yeol;Lee, Seok-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.3
    • /
    • pp.394-401
    • /
    • 2002
  • The instantaneous flow characteristics of a round jet issuing normally into a crossflow has been studied using a flow visualization technique and particle image velocimetry. The effects of parameters such as jet inflow profile and turbulence intensity of the jet are evaluated for various Reynolds numbers in range between 735 and 3150, which are based on the crossflow velocity and jet-pipe diameter. The jet-to-crossflow velocity ratio is fixed at the value of 3.3. Instantaneous later tomographic images of the symmetry plane of the crossflow jet show that there exist very different natures in the flow structures of the near-field of the jet even though the velocity ratio is same. It is found that when the turbulence intensity of jet is elevated, the shear layer becomes much thicker due to the strong entrainment of the ambient fluid by turbulent interaction between the jet and crossflow. The detailed characteristics of instantaneous velocity and vorticity fields are presented to illustrate the effects of the above parameters on the vertical structures of the crossflow jet.

A Study on the RCS Analysis and Reduction Method of Unmanned Surface Vehicles (무인수상정의 RCS 해석 및 감소 방법에 대한 연구)

  • Han, Min-Seok;Ryu, Jae-Kwan;Hong, Soon-Kook
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.12 no.4
    • /
    • pp.425-433
    • /
    • 2019
  • In this paper, the RCS analysis of the 10m unmanned surface vehicles was performed, and the factors of RCS increase were analyzed. Modeling techniques by transforming a geometric shape can reduce the RCS area, which can be used to develop stealth unmanned surface vehicles. In order to reduce the RCS, the existing Top Mast part was moved 1m to the tail part, the 5 degree tilt angle was moved below 0.5 m, and additional guided walls were installed to minimize the influence on the center and surrounding corner reflecting structures. As a result of comparing and analyzing the RCS analysis value with the existing model, it can be seen that the reduced countermeasure model is -3.79 dB lower than the existing model for all elevations. In particular, it can be seen that the strong scattering phenomenon is substantially removed in the region except the sacrificial angle region. In addition, it can be seen that in the case of -5m to 2m where the guide wall is added, the reflected signal is improved up to 20 to 40 dB or more, so that it does not appear on the 2D ISAR image. RCS analysis of unmanned surface vehicles explained the process of analyzing and identifying problem location through distance profile analysis and ISAR image analysis.

A Study on the Development and usefulness of the x/y Plane and z Axis Resolution Phantom for MDCT Detector (MDCT 검출기의 x/y plane과 z축 분해능 팬텀 개발 및 유용성에 관한 연구)

  • Kim, Yung-Kyoon;Han, Dong-Kyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.1
    • /
    • pp.67-75
    • /
    • 2022
  • The aim of this study is to establish a new QC method that can simultaneously evaluate the resolution of the x/y plane and the z-axis by producing a phantom that can reflect exposure and reconstruction parameter of MDCT system. It was used with Aquilion ONE(Cannon Medical System, Otawara, Japan), and the examination was scanned using of 120 kV, 260 mA, and the D-FOV of 300 mm2. It produced new SSP phantom modules in which two aluminum plates inclined at 45° to a vertical axis and a transverse axis to evaluate high contrast resolution of x/y plane and z axis. And it changed factors such as the algorithm, distance from gantry iso-center. All images were reconstructed in five steps from 0.6 mm to 10.0 mm slice thickness to measure resolution of x/y plane and z-axis. The image data measured FWHM and FWTM using Profile tool of Aquarius iNtusion Edition ver. 4.4.13 P6 software(Terarecon, California, USA), and analysed SPQI and signal intensity by ImageJ program(v1.53n, National Institutes of Health, USA). It decreased by 4.09~11.99%, 4.12~35.52%, and 4.70~37.64% in slice thickness of 2.5 mm, 5.0 mm, and 10.0 mm for evaluating the high contrast resolution of x/y plane according to distance from gantry iso-center. Therefore, the high contrast resolution of the x/y plane decreased when the distance from the iso-center increased or the slice thickness increased. Additionally, the slice thicknesses of 2.5 mm, 5.0 mm, and 10.0 mm with a high algorithm increased 74.83, 15.18 and 81.25%. The FWHM was almost constant on the measured SSP graph for evaluating the accuracy of slice thickness which represents the resolution of x/y plane and z-axis, but it was measured to be higher than the nominal slice thickness set by user. The FWHM and FWTM of z-axis with axial scan mode tended to increase significantly as the distance increased from gantry iso-center than the helical mode. Particularly, the thinner slice thickness that increased error range compare with the nominal slice thickness. The SPQI increased with thick slice thickness, and that was closer to 90% in the helical scan than the axial scan. In conclusion, by producing a phantom suitable for MDCT detectors and capable of quantitative resolution evaluation, it can be used as a specific method in the management of research quality and management of outdated equipment. Thus, it is expected to contribute greatly to the discrimination of lesions in the field of CT imaging.

Evaluation of Usefulness of Iterative Metal Artifact Reduction(IMAR) Algorithm In Proton Therapy Planning (양성자 치료계획에서 Iterative Metal Artifact Reduction(IMAR) Algorithm 적용의 유용성 평가)

  • Han, Young Gil;Jang, Yo Jong;Kang, Dong Heok;Kim, Sun Young;Lee, Du Hyeon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.1
    • /
    • pp.49-56
    • /
    • 2017
  • Purpose: To evaluate the accuracy of the Iterative Metal Artifact Reduction (IMAR) algorithm in correcting CT (computed tomography) images distorted due to a metal artifact and to evaluate the usefulness when proton therapy plan was plan using the images on which IMAR algorithm was applied. Materials and Methods: We used a CT simulator to capture the images when metal was not inserted in the CIRS model 062 Phantom and when metal was inserted in it and Artifact occurred. We compared the differences in the CT numbers from the images without metal, with a metal artifact, and with IMAR algorithm by setting ROI 1 and ROI 2 at the same position in the phantom. In addition, CT numbers of the tissue equivalents located near the metal were compared. For the evaluation of Rando Phantom, CT was taken by inserting a titanium rod into the spinal region of the Rando phantom modelling a patient who underwent spinal implant surgery. In addition, the same proton therapy plan was established for each image, and the differences in Range at three sites were compared. Results: In the evaluation of CIRS Phantom, the CT numbers were -6.5 HU at ROI 1 and -10.5 HU at ROI 2 in the absence of metal. In the presence of metal, Fe, Ti, and W were -148.1, -45.1 and -151.7 HU at ROI 1, respectively, and when the IMAR algorithm was applied, it increased to -0.9, -2.0, -1.9 HU. In the presence of metal, they were 171.8, 63.9 and 177.0 HU at ROI 2 and after the application of IMAR algorithm they decreased to 10.0 6,7 and 8.1 HU. The CT numbers of the tissue equivalents were corrected close to the original CT numbers except those in the lung located farthest. In the evaluation of the Rando Phantom, the mean CT numbers were 9.9, -202.8, and 35.1 HU at ROI 1, and 9.0, 107.1, and 29 HU at ROI 2 in the absence, presence of metal, and in the application of IMAR algorithm. The difference between the absence of metal and the range of proton beam in the therapy was reduced on the average by 0.26 cm at point 1, 0.20 cm at point 2, and 0.12 cm at point 3 when the IMAR algorithm was applied. Conclusion: By applying the IMAR algorithm, the CT numbers were corrected close to the original ones obtained in the absence of metal. In the beam profile of the proton therapy, the difference in Range after applying the IMAR algorithm was reduced by 0.01 to 3.6 mm. There were slight differences as compared to the images absence of metal but it was thought that the application of the IMAR algorithm could result in less error compared with the conventional therapy.

  • PDF

The Most Suitable Reference White Setting for Three-tube Projection HDTV (3 관식 프로젝션 HDTV의 기준 백색 설정)

  • Gwon, Yong-Dae;Jeong, Jae-Yeong;Lee, Gwang-Sun;Kim, Eun-Su;Lee, Sang-Hun;Song, Gyu-Ik
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.38 no.5
    • /
    • pp.529-537
    • /
    • 2001
  • According to increase of preference to the large display device, demand of a three-tube projection TV increase in the display market. But luminance per unit area of a 3-tube projection TV is less bright than that of original one -tube TV The color gamut of phosphor used in the projection TV is different to standard gamut of phosphor in NTSC. In this paper, we analyze the relationship between coordinates of RGB phosphor and RGB beam currents according to the color temperature in projection HDTV. We also proposed the range of reference white which maximize the luminance that viewer feel based on both Helmholtz-Kohlrausch effect which is visual property and degradation of image according to the change of beam profile by current-ratio.

  • PDF

Comparative proteome analysis of diploid and tetraploid root in Platycodon grandiflorum

  • Kwon, Soo Jeong;Roy, Swapan Kumar;Yoo, Jang-Hawan;Cho, Seong-Woo;Kim, Hag Hyun;Boo, Hee Ock;Woo, Sun-Hee
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2017.06a
    • /
    • pp.123-123
    • /
    • 2017
  • In spite of the potential medicinal significance and a wide range of pharmacologic properties of Platycodon grandiflorum, the molecular mechanism of its roots is still unknown. The present study was conducted to profile proteins from 3, 4 and 5 months aged diploid and tetraploid roots of Platycodon grandiflorum using high throughput proteome approach. Two-dimensional gels stained with CBB, a total of 68 differential expressed proteins were identified from the diploid root out of 767 protein spots using image analysis by Progenesis SameSpot software. Out of total differential expressed spots, 29 differential expressed protein spots (${\geq}2-fold$) were analyzed using LTQ-FTICR MS whereas a total of 24 protein spots were up-regulated and 5 protein spots were down-regulated. On the contrary, in the case of tetraploid root, a total of 86 differential expressed proteins were identified from tetraploid root out of 1033 protein spots of which a total of 39 differential expressed protein spots (${\geq}2-fold$) were analyzed using LTQ-FTICR MS whereas a total of 21 protein spots were up-regulated and a total of 18 protein spots were down-regulated. It was revealed that the identified proteins from the explants were mainly associated with the nucleotide binding, oxidoreductase activity, transferase activity. Taken together, the identified proteins may be helpful to identify key candidate proteins for genetic improvement of plants.

  • PDF