• Title/Summary/Keyword: Range of variation

Search Result 3,245, Processing Time 0.031 seconds

A Fundamental Study on the Estimation of Water Content in Fresh Concrete by the Heat-Drying Method (가열건조법에 의한 굳지않은 콘크리트의 단위수량 추정에 관한 기초적 연구)

  • 김영득;황인성;전충근;한천구;김광서
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.341-346
    • /
    • 2002
  • This study is intended to check the possibility to estimate water content by heat-drying method with variation of W/C and slump. According to the results, in case of electric range method, when water content is less than 165kg/m$^3$ in mixture, it is estimated more and in more than 165kg/m$^3$, it is estimated less. It shows that water content in gas burner method is estimated less by about 2kg/m$^3$. Also, estimated water content shows difference by less than 12kg/m$^3$ in electric range method and by less than 12kg/m$^3$ in gas burner method. Therefore, it is thinked that if tested without error from preparing a sample to calculating amount of water, water content will be estimated exactly in the construction field.

  • PDF

A New Pressure-Based PISO-Finite Element Method for Navier-Stokes Equations in All Speed Range (Navier-Stokes 점성유동의 전속도 영역 해석을 위한 새로운 압력기반 PISO-유한요소법)

  • Shim E. B.;Chang K. S.
    • Journal of computational fluids engineering
    • /
    • v.1 no.1
    • /
    • pp.112-122
    • /
    • 1996
  • A finite element scheme using the concept of PISO method has been developed to solve the Navier-Stokes viscous flows in all speed range. This scheme includes development of new pressure equation that retains both the hyperbolic term related with the density variation and the elliptic term reflecting the incompressibility constraint. The present method is applied to the incompressible two-dimensional driven cavity flow problems(Re=100, 400 and 1,000). For compressible flows, the Carter plate problem(M=3 and Re=1,000) is computed. Finally, we have simulated the shock-boundary layer interaction(M=2 and Re=2.96×10/sup 5/), a more difficult problem, and compared its results with the experiment to demonstrate the shock capturing capability of the present solution algorithm.

  • PDF

Geographic variation of song on Great Tit, Parus major of by latitude (위도(latitude)에 따른 한국산 박새(Parus Major) 소리(song)의 지리적 변이)

  • 강정훈
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1998.06d
    • /
    • pp.46-55
    • /
    • 1998
  • 본 논문은 한국산 박새의 소리를 이용한 위도에 따른 지리적 변이에 관한 논문이다. Note types은 2 음절에서는 low note가 16개, high note에서는 18개 type을 나타내었고, 3음절의 secondary-high note에서 11개의 유형을 나타내었고, low note에서는 대체로 Nm VFV type을 많이 사용하였고, high note에서는 특이하게 모든 sitedptj M type을 선호하는 것으로 나타났다. 위도에 따른 지역적이 변이는 해안지역이 내륙지역보다 더 많이 나타났고(MANOVA , p<0.001) , factor 별 공유정도는 phrase와 phraserks duration, low note의 frequency range, high note의 frequency range에서는 차이를 보였고 (ANOVA, p<0.05), 다른 factor들에서는 대부분 factor의 유형이 유사한 것으로 나타났다.

  • PDF

Radioimmunoassay Using Quality Control Materials BIO-RAD of the Suggestions for Setting Acceptable Range (BIO-RAD 정도관리 물질을 이용한 방사면역측정법의 Acceptable Range 설정에 대한 제언)

  • Park, Hee-Won;Kim, Tae-Hoon;Roh, Gyeong-Un;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.108-114
    • /
    • 2012
  • Purpose: Immunosorbent assay most commonly used in the laboratory and commercial third-party quality control material is a substance that provided by BIO-RAD. However, in Reference Sheet by radioimmunoassay test kit or a measuring device for the mention of Acceptable Range is somewhat lacking. Radioimmunoassay for the inspection of test results by setting Acceptable Range to increase the objectivity of the recommendations on the data accumulated by the manufacturer listed in the Reference Sheet is to be issued. Materials and Methods : In our hospital since 2009 partially BIO-RAD using quality control materials in 2011, excluding certain items, some items were most of the BIO-RAD third-party quality control materials are used. Thus, internal quality control data accumulated BIO-RAD's Unity Real Time program by using the items were measured. Results : BIO-RAD using quality control material items were about 50 of the 20 Point Data averages, standard deviations, variation coefficients were calculated to measure the Acceptable Range of kit, automated immunoassay attributed Roche Elecsys / E170 / cobas e Systems the measures and compared. Conclusions : BIO-RAD QC materials commonly used hospital and peer group by setting the measurement kit, suitable for laboratory equipment for radioimmunoassay of Acceptable Range manufacturer recommendation to increase the objectivity of the test results by national and international recognition for radioimmunoassay should seek to increase.

  • PDF

A study on medium-low pressure gauge for domestic production (중.저기압 압력계의 국산화에 관한 연구)

  • 백용현
    • 전기의세계
    • /
    • v.29 no.8
    • /
    • pp.519-523
    • /
    • 1980
  • The traditional mechanical manometer is improved to develop more convenient and precise manometer in continuous measurement of the gas pressure in medium-low vacuum range (1x10$^{-1}$ -10 Torr.) Glass (solid) is used as a detector material of the improved manometer. Using the strain gauge adhered to thin glass board, mechanical strain corresponding to variation of pressure in measurement system is converted into quantity of electricity, and the quantity of electricity is amplified. Experiments have also shown that the improved manometer have more advantages in reproducibility, measured sensibility, and responsible velocity than taditional one.

  • PDF

7-Phase BLDC Motor Drive System using MSTC (MSTC를 이용한 7상 BLDC 모터 구동시스템)

  • 전윤석
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.429-433
    • /
    • 2000
  • Recently the demand of motor for industrial household machinery is increasing. As Switching devices and control technology are progressing so the use of BLDC Motor is increasing But 3-Phase BLDC Motor generally used has pulsating torque and speed variation in commutation so the range of it's application is limited high speed application Especially to solve these problems it is necessary to increase phase to Motor so study of Poly-Phase BLDC Motor is progressing. In this paper we designed 7-Phase BLDC Motor drive system and MSTC(Minimum Switching Time Controller)

  • PDF

$\pi$-A Characteristics of Arachidic Acid Monolayer (Arachidic Acid 단분자막의 $\pi$-A 특성)

  • 이대일;최용성;장상묵;권영수
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1991.10a
    • /
    • pp.10-11
    • /
    • 1991
  • In this paper, Arachidic Acid of long-chain fatty acid was soluted by chloroform and observed $\pi$-A curve in trough. In our experimental result, optimum pressure for fabricating the LB film was 30mN/m. In $\pi$-A curve measurment, temperature dependence was investigated between 20-50($^{\circ}C$). However, in this temperature range, the variation of solid phase pressure was not observed.

Fiber-optic interferometric accelerometer using silicon micromachining. (실리콘 마이크로머시닝을 이용한 광섬유 간섭계형 가속도 센서)

  • 권혁춘;김응수;김경찬;강신원
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.02a
    • /
    • pp.322-323
    • /
    • 2003
  • Silicon substrate was fabricated by bulk silicon micromachining and it's structure is based on a proof mass suspended by two beam. To monitor the acceleration, dynamic excitation of accelerometer was performed using a shaker. The attached FFPI and suspension beam are bent because support beam move with variation of the proof mass. Thus phase difference detected by the acceleration change. So we can know that resonance frequency of fabricated accelerometer is about 557 Hz and dynamic range was measured from 0 g to 2 g.

  • PDF

LNA Module Development for the Ka-Band Satellite Transponder (Ka-대역 위성중계기용 저잡음 증폭기 모듈 개발)

  • 유영근;염인복
    • Proceedings of the IEEK Conference
    • /
    • 1998.10a
    • /
    • pp.323-326
    • /
    • 1998
  • A LNA(Low Nosise Amplifer) module for the Ka-band satellite transponder has been developed, which is composed of developed two MMIC chips and 50$\Omega$ line. This LNA exhibited noise figure less than 3.12dB, linear gain higher than 32dB from 30.085GHz to 30.885GHz frequency range. Temperature test from $20^{\circ}to$ $60^{\circ}C$ of the LNA Module showed very small noise figure and linear gain variation of 0.2 dB and 0.4dB.

  • PDF

교류전동기구동을 위한 광역전류원콘버어터 1

  • 조규형
    • 전기의세계
    • /
    • v.29 no.11
    • /
    • pp.733-741
    • /
    • 1980
  • A novel six-step current source inverter (CSI) with DC-side commutation and energy rebound capability is presented with detailed explanation of the circuit operation. The prposed inverter can operate in a very wide range of frequency and load variation by employing DC-side commutation. Also, the energy rebound makes the use of low voltage SCR's possible and increases the inverter efficiency. Motor operation is also possible in four quadrants in this proposed current source inverter. The advantages of the proposed CSI over conventional ones are described and experimental results are given in oscillograms.

  • PDF