• 제목/요약/키워드: Range of Angle

검색결과 2,451건 처리시간 0.027초

The Immediate Effects of Five-Toed Shoes on Foot Structure

  • Yi, Kyung-Ock
    • 한국운동역학회지
    • /
    • 제21권4호
    • /
    • pp.397-403
    • /
    • 2011
  • The purpose of this study is to analyze the immediate effects of five toed shoes on foot structure. Subjects consisted of 26 college-aged women with pes planus. X-ray analysis of student feet were performed both barefooted and with five toed shoes. Dependent variables were hallux valgus angle, calcaneal inclination angle, 1st metatarsal declination angle, and intermetartarsal angle. Independent t-test was used for statistical analysis along with SAS. Overall, there were statistically significant changes of test subject's dependent variables when wearing five toed shoes. Specifically, the hallux valgus angle decreased, the calcaneal inclination angle and 1st metatarsal inclination angle increased, and intermetatasal angles both increased and decreased, shifting towards normal range. In every case the dependent variables shifted towards a more normal range while subjects wore five toed shoes. This study only examined the immediate corrective effects of five toed shoes on foot structure, but long-term studies are needed to understand the prolonged effects of five toed shoes on foot structure.

레인지 후드용 시로코 홴의 성능 향상을 위한 연구 (Numerical study on the Performance Improvement of the Sirocco Fan in a Range Hood)

  • 박상태;최영석;박문수;김철호;권오명
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.572-577
    • /
    • 2004
  • This paper presents numerical study on the performance improvement of the sirocco fan in a range hood. The performance of sirocco fan means a higher flowrate, a higher static pressure and a lower required motor power in a fixed geometry constraint. Various impeller geometric parameters, such as blade profile, blade diameter, blade thickness profile and blade exit angle, were investigated by numerically and the results were compared with each other to know the effects on the performance. In this approach, the volute geometry were fixed with the original shape. The numerical results show that the blade profile with airfoil shape and small exit blade thickness increases the performance. The blade exit angle shows optimum angle within a varied range. The efficiency of the optimized exit angle was about $10\%$ higher than the base blade exit angle and the static pressure was about $28\%$ higher at the flow coefficient 0.22.

  • PDF

자동회전의 트림 범위와 특성(I): 로터 스피드 한계와 피치범위 (Trim Range and Characteristics of Autorotation(I): Rotor Speed Limit and Pitch Range)

  • 김학윤;최성욱
    • 한국항공우주학회지
    • /
    • 제39권6호
    • /
    • pp.487-497
    • /
    • 2011
  • 자동회전 상태로 속도 증가 시 로터 속도의 변화와 피치 범위를 조사하기 위하여 수치 해석을 수행하였다. 정상 자동회전 상태를 구하기 위하여 과도모사법(Transient Simulation Method:TSM)을 사용하였다. 풍속의 증가에 대응하기 위하여 로터 블레이드를 2차원 압축성 Navier-Stokes 솔버로 해석하여 공력계수를 계산하였고 이를 과도모사법에 사용하였으며 유도 속도장 변화를 모사하기 위하여 Pitt/Peters 유도속도 이론을 적용하였다. 설정된 토크 평형 조건에서 풍속, 샤프트각, 피치각의 조합을 출력하여 로터의 회전속도와 변수의 범위를 조사하였다. 깃 끝 마하수의 변화에 따른 로터 회전속도의 변화를 살펴보았고 샤프트각의 감소에 따른 피치각의 트림 범위를 고찰하였다.

추적레이다의 표적 탐지 및 추적 기술 동향 (Target Acquisition and Tracking of Tracking Radar)

  • 신한섭;최지환;김대오;김태형
    • 항공우주산업기술동향
    • /
    • 제7권1호
    • /
    • pp.113-118
    • /
    • 2009
  • 추적레이다는 안테나로부터 폭이 매우 좁은 펄스를 표적에 위치시켜 표적에서 돌아오는 신호를 수신하여 표적의 위치 (거리, 각도, 속도 등)를 추적하는 장비이다. 추적레이다가 특정한 표적을 탐지하고 추적하기에 앞서 표적과 주변 환경의 특성을 예측하기 위해 잡음 신호와 표적 신호의 수학적 모델이 필요하다. 본 논문에서는 일반적으로 적용되는 잡음 신호와 표적 신호의 모델에 대한 이론적인 내용을 소개하였고, 이와 더불어 표적의 탐지와 추적을 위한 거리 추적, 각도 추적 및 도플러 주파수 추적에 대한 일반적인 기법들을 기술하였다.

  • PDF

절단 볏짚의 물리적 성질 (Some Physical Properties of Chopped Rice Straw)

  • 박승제;김명호
    • Journal of Biosystems Engineering
    • /
    • 제23권6호
    • /
    • pp.583-590
    • /
    • 1998
  • This study was performed to determine the kinetic friction coefficient bulk density, dynamic and static angle of repose, and terminal velocity of the chopped rice straw in the moisture range of 8~23%, which could be used for better design and operation of the processing machinery and handling facilities. Friction coefficient was determined from the horizontal traction force measured by pulling the container holding the mass of rice straw on the various plate materials. Bulk density was measured with an apparatus consisting of a filling funnel and a receiving vessel. Dynamic angle of repose was calculated from the photos of bulk samples piled by gravity flow on a circular platform. Static angle of repose was determined by measuring the side angle of the bulk material which was left in the cylindrical container after natural discharge of the bulk sample through a circular hole in the bottom plate. Kinetic friction coefficients of rice straw on the PVC, mild steel, stainless steel, and galvanized steel were in the range of 0.303~0.434, 0.222~0.439, 0.204~0.448, and 0.206~0.407, respectively. and indicated linear increase with moisture content. The effects of moisture change on the friction coefficients were in the order of PVC, mild steel, galvanized steel, and stainless steel. Bulk density, dynamic and static angle of repose, and terminal velocity were in the range of 56.8~60.3 kg/m$^3$, 41.4~45.9$^{\circ}$, 94.4~100.8$^{\circ}$, and 1.07~4.48 m/s, respectively, and were increased linearly with the moisture content.

  • PDF

왕겨의 물리적 성질 (Physical Properties of Rice Husk)

  • 박승제;김명호;신형명
    • Journal of Biosystems Engineering
    • /
    • 제30권4호
    • /
    • pp.229-234
    • /
    • 2005
  • Kinetic friction coefficient, bulk density, dynamic and static angle of repose, and terminal velocity of rice husk at the moisture range 7 to $23\%$ w.b. were determined. It could lead to better design and operation of the processing machinery and handling facilities. Friction coefficient was determined from the horizontal traction force measured by pulling the container holding a mass of rice husk on various plate materials. Dynamic angle of repose was calculated from the photos of bulk samples piled by gravity flow on a circular platform. Static angle of repose was determined by measuring the side angle of the bulk material which was left in a cylindrical container after natural discharge of the bulk sample through a circular hole in the bottom plate. Kinetic friction coefficients of rice husk were in the range of $0.254\~0.410,\;0.205\~0.520,\;0.229\~0.400,\;and 0.133\~0.420$ on PVC, mild steel, galvanized steel, and stainless steel, respectively. Bulk density, dynamic and static angle of repose, and terminal velocity were in the range of $91.7\~98.3$ $kg/m^3$, $40.2\~47.6^{\circ},\;52.8\~83.7^{\circ},$ and $1.36\~1.73$ m/s, respectively. These physical properties of rice husk increased linearly as the moisture content increased.

베인 회전각의 변화에 따른 디퓨저의 성능특성에 관한 실험적 연구 (Experimental Study on the Performance Characteristics of the Diffuser as a Relation of the Variation of Vane Turning Angle)

  • 조성국;강신형
    • 한국유체기계학회 논문집
    • /
    • 제2권2호
    • /
    • pp.74-80
    • /
    • 1999
  • Recently, impressive gains of performance and efficiency with apparently little or no loss in flow range have been seen with the use of LSVD(Low Solidity Vaned Diffuser) over vaneless diffuser. Experiments of the effects of the vane turning angle variations(positive, negative, zero), with the other design parameters fixed, on the performance and flow range were carried out. Diffusers with a zero turning angle have the best characteristics in terms of performance and efficiency and the FFT results show different frequency characteristics due to vane turning angles in low flow range.

  • PDF

Clinical Comparison of Posterolateral Fusion with Posterior Lumbar Interbody Fusion

  • Kim, Chang-Hyun;Gill, Seung-Bae;Jung, Myeng-Hun;Jang, Yeun-Kyu;Kim, Seong-Su
    • Journal of Korean Neurosurgical Society
    • /
    • 제40권2호
    • /
    • pp.84-89
    • /
    • 2006
  • Objective : The purpose of this study is to compare the outcomes of two methods for stabilization and fusion : Postero-Lateral Fusion [PLF, pedicle screw fixation with bone graft] and Posterior Lumbar Interbody Fusion [PLIF, cage insertion] for spinal stenosis and recurred disc herniation except degenerative spondylolisthesis. Methods : Seventy one patients who underwent PLF [n=36] or PLIF [n=35] between 1997 and 2001 were evaluated prospectively. These two groups were compared for the change of interbody space, the range of segmental angle, the angle of lumbar motion, and clinical outcomes by Prolo scale. Results : The mean follow-up period was 32.6 months. The PLIF group showed statistically significant increase of the interbody space after surgery. However, the difference in the change of interbody space between two groups was insignificant [P value=0.05]. The range of segmental angle was better in the PLIF group, but the difference in the change of segmental angle was not statistically significant [P value=0.0l7]. Angle of lumbar motion was similar in the two groups. Changes of Prolo economic scale were not statistically significant [P value=0.193]. The PLIF group showed statistically significant improvement in Prolo functional scale [P value=0.003]. In Prolo economic and functional scale, there were statistically significant relationships between follow-up duration [P value<0.001]. change of interbody space [P value<0.001], and range of segmental angle [P value<0.001]. Conclusion : Results of this study indicate that PLIF is superior to PLF in interbody space augmentation and clinical outcomes by Prolo functional scale. Analysis of clinical outcomes showed significant relationships among various factors [fusion type, follow-up duration, change of interbody space, and range of segmental angle]. Therefore, the authors recommend instrumented PLIF to offer better clinical outcomes in patients who needed instrumented lumbar fusion for spinal stenosis and recurred disc herniation.

Short-range Visible Light Positioning Based on Angle of Arrival for Smart Indoor Service

  • Lee, Yong Up;Park, Seop Hyeong
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권3호
    • /
    • pp.1363-1370
    • /
    • 2018
  • In visible light (VL) positioning based on angle of arrival (AOA) estimation for smart indoor service, the AOA parameters obtained at the receiver has sometimes a random and distributed angle form instead of a point angle form due to the multipath transfer of the actual visible light and short positioning distance. The AOA estimation of a VL signal with a random and parametric distributed angle form may give incorrect AOA parameter estimates, which may result in poor VL positioning performance. In this paper, we classify the AOA parameters of the received VL signal into three forms according to the actual positioning channel environment and consider the short-range VL positioning method. We propose a subspace-based AOA parameter estimation technique and a data fusion method, and analyzed the proposed method by simulation and the measurement of the real VL channel characteristics.

에어커튼형 레인지후드의 슬롯 토출 각도 변화와 배기 효율 (Effect of Slot Discharge-Angle Change on Exhaust Efficiency of Range Hood System with Air Curtain)

  • 성순경
    • 설비공학논문집
    • /
    • 제27권9호
    • /
    • pp.468-474
    • /
    • 2015
  • When oil is used for cooking in detached or apartment houses, large amounts of oil-mist, smoke, and particulate substances are generated and dispersed into the indoor-air environment. These pollutants diffuse into the surroundings and spread their odor while rising fast at a high temperature due to the heat energy from the gas range. Although the exhaust gas is discharged from the exhaust hood, which is installed on the top of a gas range to remove the diffuse pollutants, the exhaust conditions can vary greatly because they depend on the shape of the exhaust hood and the discharge rate. In this paper, the air that is required for the gas-exhaustion process is supplied by an air curtain that surrounds the kitchen hood, and the pollutant-capturing efficiency varies depending on the angle of the discharge grills; the pollutant-capturing efficiency was studied using a numerical-analysis method. The results indicate that the pollutant-capturing efficiency is not significantly changed by a change of the discharge-grill angle at a low air-discharge rate; however, at a high air-discharge rate, the efficiency value increases with an increase of the discharge-grill angle, whereby the best value occurs at 30 degrees and the efficiency decreases above this angle. Below 30 degrees, the effect of the discharge rate on the capturing efficiency is more than that of the discharge-grill angle.