• 제목/요약/키워드: Range hood system

검색결과 20건 처리시간 0.023초

An active system for unnecessary noise reduction in kitchen range hoods

  • Kim, Eunhee;Jang, Jaechun;Lim, Changmok
    • 한국컴퓨터정보학회논문지
    • /
    • 제21권3호
    • /
    • pp.91-96
    • /
    • 2016
  • We have surrounded undesired living noises in our life. One of biggest noises coming out of range hood during cooking in the kitchen. A range hood is one of the most important appliances in the kitchen because it ventilates polluted air out during cooking, and maintains air quality in the kitchen. But current kitchen range hoods bring up some issues; First, the range hoods consume massive amount of standby power not in use condition. Second, current models have designed manual fan operating system with sudden onset of noise with starting. In this paper, we propose an auto control system entire processes from air ventilation to noise reduction. Our system is consist of three parts (Eco-sensors pack, Main Controller and Active Noise Controller); Eco-sensors pack detects air pollution of kitchen areas and sends the detection values to Main Controller. Main Controller determines operation of range hood by detected values. Active Noise Controller is located inside of the range hood. It received starting signals from Main Controller which elicits degrees of polluted air condition and fan operating speed from 1 to 3. Once Active Noise Controller detected the signals, it runs a ventilating fan until new value from Main Controller becomes 0. while the range hood works, A noise cancellation algorithm inside of Active Noise Controller become activated to reduce levels of noise. As a result, the proposed system clearly shows reduction in power consumption include standby power and decreases in levels of noise.

미세 다공판을 이용한 레인지 후드의 소음저감 (Noise Reduction of a Range Hood using Micro-Perforated Panel)

  • 김덕한;송화영;이동훈;이창근;김동윤
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.1205-1208
    • /
    • 2006
  • This paper introduces a study for the noise reduction of a range hood for household. Generally, range hoods have a built-in sirocco fan from which rumbling noise is generated. Though the rumbling noise has low noise level. this noise makes most of the users nervous due to the its low frequency characteristics. For the purpose of noise reduction, in this study, a micro-perforated panel system is installed in the fan housing of range hood. From the experimental results, it is confirmed that the noise level emitted from the range hood is decreased over 2dB(A) in all frequency regions due to the effect of noise reduction by micro-perforated panel system.

  • PDF

가정용 레인지 후드의 소음저감에 관한 연구 (A Research on the Noise Reduction of Range Hood for Household)

  • 홍병국;송화영;이동훈;이창근;김동윤
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.449-452
    • /
    • 2005
  • This paper introduces a study for the noise reduction of a range hood for household. Generally, range hoods have a built-in sirocco fan from which squawky noises are generated. Though the squawky noises have low noise level, these kinds of noises make most of the users nervous. For the purpose of noise reduction, in this study, a perforated plate system is installed in the fan housing of range hood. From the experimental results, it is confirmed that the noise level omitted front the range hood is decreased above 2dB(A) in all frequency regions due to the effect of noise reduction by perforated panel system.

  • PDF

레인지후드 역류 저감 시스템 개발 (Range Hood Backflow Reduction Device Development)

  • 이원섭
    • 한국기계기술학회지
    • /
    • 제20권6호
    • /
    • pp.906-911
    • /
    • 2018
  • This study was conducted to develop an efficient high performance range hood and exhaust system for quickly discharging flue gas, smoke, and odor generated when food is cooked in the kitchen, and the following results were obtained. Reverse current rate of 1.53 m/s of the range exhaust system was improved to achieve the inlet speed of 0.3 m/s or less. An efficient range system was constructed by improving the hood exhaust flow by 5.6 m/s at the existing 4.5 m/s.

주방환기 시스템의 소음 저감과 실내 음장분포 예측에 관한 연구 (A Research on the Noise Reduction of a Kitchen Ventilation System and the Prediction of Sound Distribution in a Kitchen and Room)

  • 송화영;이동훈;이창근;김동윤;홍병국
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.494-499
    • /
    • 2005
  • This paper introduces a study for the noise reduction of a range hood for household. Generally, range hoods have a built-in sirocco fan from which harsh noises are generated. Though the harsh noises have low noise level, these kinds of noises make most of the users nervous. For the purpose of noise reduction, in this study, a perforated plate system is installed in the fan housing of range hood. From the experimental results, it is confirmed that the noise level emitted from the range hood was decreased more than 10dB(A) in all 1/3 octave bands due to the effect of noise reduction by perforated plate systems.

  • PDF

주방 환기 시스템에서 렌지 후드의 소음 감소 방안 (Noise Reduction of Range Hood in Kitchen Ventilation System)

  • 최영석;김철호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.848-851
    • /
    • 2004
  • This paper studied a method for minimizing the noise level emitted from range hoods. Range hoods were used for discharging various hazardous materials generated during household cooking to the outdoors, thus preventing them from being diffused through rooms in the house since they are the main cause of air pollution within dwellings. This study assumed that static pressure was not applied at the discharge outlet of the range hood. As such, the range hood was installed on the wall without the use of a connecting duct or other connectors attached to its discharge outlet. The vibration having the greatest influence on the noise level was determined by measuring the vibration at the front side of the hood where the acoustic omission was at its maximum. A method was then proposed to reduce the noise by simply suppressing the vibration at the vibrating part.

  • PDF

렌지 후드 용 개선된 시로코 홴의 소음특성 변화 (Noise Characteristics of Improved Sirocco Fan for Range Hood)

  • 김철호;최영석
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.209-212
    • /
    • 2005
  • Recently, since structures have become extremely airtight with the development of high-rise apartments, mixed use residential and commercial buildings and offices, large capacity range hoods have become commonly implemented. However, the high noise level caused by this range hood system made of thin plate is the cause of increased complaints among users. In this study, the level of noise emitted from this type of range hood was measured by height at the user's location in the kitchen. It was confirmed that a great deal of noise was emitted in the downward direction of the hood. In order to minimize the noise emitted from this type of range hood, a new type of fan was manufactured. This was done by changing only the material and shape of the fan, since it was determined to be the primary source of noise emission. Then a comparison and evaluation were carried out regarding the noise characteristics between the new type of fan and the existing type of fan. As a result, it was confirmed that the noise from the new fan was reduced by more than 2 dB compared to the existing fan without noise interference at the discharge end.

  • PDF

에어커튼형 주방 레인지후드의 배기 특성 (Exhaust Characteristics of Kitchen Hood System with Inclined Air Curtain)

  • 성순경
    • 설비공학논문집
    • /
    • 제26권12호
    • /
    • pp.594-599
    • /
    • 2014
  • There have been many cases that the air curtain installed in the apartment can not well remove the gases such as carbon dioxide and particles such as smokes, oils and vapors generated during the cooking to disperse the pollutants into the room. This study uses the numerical analysis to show how the pollutant-removing performance of the range hood is changed when the air curtain is installed on the range hood of kitchen. As a result of the study, it turned out that, when the air amount supplied by air curtain through the slot was about 60% of exhaust amount, the capturing efficiency of range hood for pollutants increased by 70~80% more than the case without the air curtain. Even when the exhaust amount was small, the capturing efficiency was improved a lot with the use of air curtain. In case that the air flow velocity of slot was greater than 2 m/s, the capturing efficiency turned out to decrease.

주방용 후드 수평급기의 최적속도 결정에 관한 연구 (Study on the Optimal Velocity of Horizontal Air Jet of a Range hood system)

  • 김상규;박성근;용호택;김동윤;최형권
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.63-68
    • /
    • 2005
  • In the present paper, the study on the optimal horizontal air jet velocity of a range hood system has been studied by three dimensional numerical simulation. It has been shown that the air jet of a range flood system generates coanda effect confining the contaminated (high temperature) air in a certain region while the jet pushes out more contaminated air into a room as the jet velocity increases. Therefore, the optimal jet velocity has been determined by the combination of the two mechanism.

  • PDF

조리대에 급기구를 가진 주방 레인지후드의 배기 성능 (Exhaust Performance of a Kitchen Hood System with a Supply Air Slot on a Kitchen Table)

  • 성순경
    • 설비공학논문집
    • /
    • 제28권12호
    • /
    • pp.489-494
    • /
    • 2016
  • There have been many cases when an air curtain installed in the apartment could not remove the gases well, such as carbon dioxide and particles like as smoke, oils, and vapors generated during cooking to disperse pollutants into the room. This study used a numerical analysis to show how the pollutant-removing performance of the range hood is changed when the air curtain is installed front of the kitchen table. The result of this study was that when the air amount supplied by an air curtain through the slot was about 50% of the exhaust amount, the capturing efficiency of the range hood for pollutants increased 90% more than without an air curtain. Even when the amount of supplied air was small, the capturing efficiency improved markedly with the use of an upward air curtain. In case that the air flow rate of the slot was greater than 60%, the capturing efficiency decreased.