• 제목/요약/키워드: Range Sensor

검색결과 2,611건 처리시간 0.03초

광섬유 EFPI 센서를 이용한 실시간 고정밀 변위 측정 (Real-time Measurement of Precision Displacement using Fiber Optic EFPI Sensor)

  • 박상욱;김대현;김천곤;홍창선
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2003년도 추계학술발표대회 논문집
    • /
    • pp.154-157
    • /
    • 2003
  • Precision displacement of less than a few nm resolution was measured in real-time using fiber optic EFPI sensor. The novel method for real-time processing of analyzing EFPI output signal was developed and verified. Linearity in the mean values of interferometric light intensity among adjacent fringes was shown, and the sinusoidal approximation algorithm that estimates past and coming fringe values was verified through the linearity. Real-time signal processing program was developed, and the intensity signal of the EFPI sensor was transformed to the phase shift with this program. The resolution below 0.4 ~ 10 nm in the displacement range of $0 ~ 300\mu\textrm{m}$ was obtained by reducing the photodetector noise using low-pass filter and signal averaging. The nano-translation stage with a Piezo-electric actuator and the EFPI sensor system was designed and tested. This stage successfully reached to the desired destination in $15\mu\textrm{m}$ range within 1 nm accuracy.

  • PDF

구조가 간단한 마이크로파 센서 개발 (Development of Simple Structure Microwave Sensor)

  • 정순원;이재진;구경완
    • 전기학회논문지P
    • /
    • 제57권3호
    • /
    • pp.270-274
    • /
    • 2008
  • The microwave sensor in which the sensitivity was excellent and a structure is simple was developed and it manufactured. And the sensing range that uses the developed product was confirmed. When the developed microwave sensor was set up in the ceiling of a building, we confirmed that the amplitude of the sensitive area increased as the tilting angle was enlarged. The sensitive area became a greatest in case the tilting angle was 65 degree. According to the height of a ceiling, because the sensing range is determined, in case of using in the building in which the height of a ceiling is enough secured it is determined to secure the more wide sensitive area. Moreover, the configuration of the circuit having the simple structure makes the miniaturization of a product, and the light weight possible. It is considered to have the price competitive power which it reduces the manufacturing cost, is sufficient.

화상센서의 잡음 특성 측정 (Measurement of noise characteristics of an image sensor)

  • 이태경;한재원
    • 정보저장시스템학회논문집
    • /
    • 제5권2호
    • /
    • pp.89-95
    • /
    • 2009
  • We setup the system to measure the noise characteristics of the 5M complementary metal-oxide semiconductor (CMOS) image sensor by generic measurement indicator of Standard mobile imaging architecture (SMIA) which is one of internal standard of mobile imaging architecture. To evaluate the effect of environment and setting parameters, such as temperature and integration time, we measure the variation of the dark signal, dynamic range and fixed pattern noise of image sensor. We also detect the number of defective pixels and cluster defects defined as adjacent single defect pixels at 5M CMOS image sensor. Then, we find the existence of some cluster defects in experiment, which are not expected in calculation.

  • PDF

A Highly Sensitive Humidity Sensor Using a Modified Polyimide Film

  • Kim, Yong-Ho;Lee, Joon-Young;Kim, Yong-Jun;Kim, Jung-Hyun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제4권2호
    • /
    • pp.128-132
    • /
    • 2004
  • This paper presents the design, fabrication sequence and measurement results of a highly sensitive capacitive-type humidity sensor using a polyimide film without hydrophobic elements. The structure of the humidity sensor is MIM (metalinsulator-metal). For a high sensitivity, a modified aromatic polyimides as a moisture absorbing layer has been synthesized instead of using general polyimides containing hydrophobic elements. The polyimide film was obtained by synthesizing and thermally polymerizing polyamic acid composed of m-pyromellitic dianhydride, phenelenediamine and dimethylacetamide. Characteristics of fabricated sensors which include sensitivity, hysteresis and stability have been measured. The measurement result shows the percent normalized capacitance change of 0.37/%RH over a range from 10 to 90%RH, hysteresis of 0.77% over the same %RH range and maximum drift of 0.25% at 50%RH. The result shows that the developed humidity sensor can be applied to evaluate a hermeticity of various sensors and actuator systems as well as micro packages.

A Design of a Variable Interval Sensing Scheme for the Sensor Networks

  • Cha, Hyun-Chul
    • 한국컴퓨터정보학회논문지
    • /
    • 제20권11호
    • /
    • pp.63-68
    • /
    • 2015
  • In this paper, we propose a new energy efficient scheme which can prolong the life of sensor networks, it should be able to reduce the number of sensing. We use the concept of safe zone for manage the appropriate range of properties. We measure the distance between the sensed temperature value and the center of the zone, and calculate the next sensing interval based on this distance. We name our proposed scheme "VIS". To assess the performance of the proposed scheme the actual temperature data was collected using the sensor node. The algorithm was implemented through the programming and was evaluated in a variety of settings. Experimental results show that the proposed algorithm is to significantly reduce the number of sensing in terms of energy efficiency while having the ability to know the state of the sensor nodes periodically. Our VIS algorithm can be useful in applications which will require the ability of control to the temperature within a proper range.

FMCW 레이더 센서 기반의 강의용 광역 마이크 시스템 (Widerange Microphone System for Lecture using FMCW Radar Sensor)

  • Oh, Woojin
    • 한국정보통신학회논문지
    • /
    • 제25권4호
    • /
    • pp.611-614
    • /
    • 2021
  • In this paper, we propose a widerange array microphone for lecturer tracked with Frequency Modulated Continuous Waveform (FMCW) radar sensor. Time Difference-of-Arrival (TDoA) is often used as audio tracking, but the tracking accuracy is poor because the frequency of the voice is low and the relative frequency change is large. FMCW radar has a simple structure and is used to detect obstacles for vehicles, and the resolution can be archived to several centimeter. It is shown that the sensor is useful for detecting a speaker in open area such as a lecture, and we propose an wide range 4-element array microphone beamforming system. Through some experiments, the proposed system is able to adequately track the location and showed a 8.6dB improvement over the selection of the best microphone.

Practical Data Transmission in Cluster-Based Sensor Networks

  • Kim, Dae-Young;Cho, Jin-Sung;Jeong, Byeong-Soo
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제4권3호
    • /
    • pp.224-242
    • /
    • 2010
  • Data routing in wireless sensor networks must be energy-efficient because tiny sensor nodes have limited power. A cluster-based hierarchical routing is known to be more efficient than a flat routing because only cluster-heads communicate with a sink node. Existing hierarchical routings, however, assume unrealistically large radio transmission ranges for sensor nodes so they cannot be employed in real environments. In this paper, by considering the practical transmission ranges of the sensor nodes, we propose a clustering and routing method for hierarchical sensor networks: First, we provide the optimal ratio of cluster-heads for the clustering. Second, we propose a d-hop clustering scheme. It expands the range of clusters to d-hops calculated by the ratio of cluster-heads. Third, we present an intra-cluster routing in which sensor nodes reach their cluster-heads within d-hops. Finally, an inter-clustering routing is presented to route data from cluster-heads to a sink node using multiple hops because cluster-heads cannot communicate with a sink node directly. The efficiency of the proposed clustering and routing method is validated through extensive simulations.

0.4nm 해상도의 엔코더 타입 전기용량형 변위센서 (An 0.4nm Resolution Encoder-like Capacitive Displacement Sensor)

  • 강대실;김무진;문원규
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.1450-1454
    • /
    • 2007
  • A Contact-type Linear Encoder-like Capacitive Displacement Sensor (CLECDiS) has been developed to measure displacements at high accuracy within a long measurement range. In this paper, we have worked on improving the performance and reliability of the sensor. The performance increase can be done by introducing the smaller electrode patterns of $4{\mu}m$ width. In order to improve the reliability of the sensor we have changed the electrode layers from chrome-gold to chrome-gold-chrome and re-design its supporting structure. The newly-designed sensor is fabricated and tested to show that its sensitivity is $35pF/{\mu}m$, which implies that its resolution may be 0.36nm if SNR (Signal-to-Noise-Ratio) is 80.1dB. It is about ten times of that $(3.14pF/{\mu}m)$ of its previous version with 10${\mu}m$ electrodes. The total measurement range remains the same as the previous one; 15mm. The calibration experiments show its improved performance and reliability.

  • PDF

다자유도 탄소섬유판 힘/토크 센서 개발 (Development of Multi-Degree of Freedom Carbon Fiber Plate Force/Torque Sensor)

  • 이동혁;김민규;조남규
    • 한국정밀공학회지
    • /
    • 제29권2호
    • /
    • pp.170-177
    • /
    • 2012
  • A force/torque sensor using carbon fiber plate was designed and developed to make the sensor be able to measure a wide range of multi degree of force and torque. Using carbon fiber plate of 0.3 mm thickness, the sensor was designed and developed, which has a ${\mu}N$ level order of resolution and about 0.01 N ~ 390 N of wide measurement range. The elastic deformation part has a tripod plate structure and strain gauges are attached on the part to detect the force/torque. The coefficient of determination for the sensor is over 0.955 by the calibration experiment so that the linearity of the sensor is confirmed to be good. Also, experiments on applying 0.005 ~ 40 kg (0.05 ~ 390 N) to each axis were implemented and the sensor is proved to be safe under a high load. Finally, to verify the function calculating the direction of load vector, the directions of various load vectors which have the same magnitude but different directions and the directions of the calculated load vectors are compared and analyzed to accord well.

멀티센서 시스템을 이용한 3차원 형상의 기상측정에 관한 연구 (A Study on the 3-dimensional feature measurement system for OMM using multiple-sensors)

  • 권양훈;윤길상;조명우
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2002년도 추계학술대회 논문집
    • /
    • pp.158-163
    • /
    • 2002
  • This paper presents a multiple sensor system for rapid and high-precision coordinate data acquisition in the OMM (On-machine measurement) process. In this research, three sensors (touch probe, laser, and vision sensor) are integrated to obtain more accurate measuring results. The touch-type probe has high accuracy, but is time-consuming. Vision sensor can acquire many point data rapidly over a spatial range but its accuracy is less than other sensors. Also, it is not possible to acquire data for invisible areas. Laser sensor has medium accuracy and measuring speed among the sensors, and can acquire data for sharp or rounded edge and the features with very small holes and/or grooves. However, it has range- constraints to use because of its system structure. In this research, a new optimum sensor integration method for OMM is proposed by integrating the multiple-sensor to accomplish mote effective inspection planning. To verify the effectiveness of the proposed method, simulation and experimental works are performed, and the results are analyzed.

  • PDF