• Title/Summary/Keyword: Range Safety

Search Result 2,996, Processing Time 0.032 seconds

Influence of the change of driving confidence level upon driving behavior in the age groups (운전확신수준의 변화가 연령별 운전행동에 미치는 영향)

  • Soonyeol Lee;Soonchul Lee;Sunjin Park
    • Korean Journal of Culture and Social Issue
    • /
    • v.12 no.3
    • /
    • pp.23-47
    • /
    • 2006
  • The purpose of this research is to study the relation between the change of driver's driving confidence level in the age categories and driving behavior. To survey the driving confidence level, we used the 'Driving Confidence Scale' questionnaire and surveyed the drive career, mileage, driving days, violation of traffic regulation (drunk driving, overspeed), traffic accident experience (assaulter, sufferer) together. The subjects of investigation were from 19-year-old to 80-year-old and 1,055 persons were participated in the research totally. To examinethe structure of driving confidence level, we executed the factor analysis. We compared the driving confidence level in the age categories (under 29-year-old, 30~39, 40~49, 50~64, over 65-year-old) and studied the relation between driving confidence level and driving behavior. Driving confidence level was composed of 4 factors such as 'insensibility to situation', 'unsafe driving', 'careless concentration' and 'self-efficacy of driving', and there was decreasing tendency for driving confidence level and overall driving behavior according to increasing age. Driving confidence level had the interrelation with age range, assaulting accident, suffered accident, driving period, drunk driving, overspeed, driving career and so on. We examined the difference of driving confidence level and driving behavior by dividing the participated drivers' groups into the traffic accident experienced group, drunk driving group and overspeed driving group, and there was a significant difference on driving confidence level and driving behavior between the group who had not experienced the violation of traffic regulation or traffic accident and another group who had experienced the violation of traffic regulation or traffic accident.

The Current State of Intended Equipment for Heating in Medical Use Based on Domestic Licensed Medical Devices (국내 인·허가 온열의료기기 기술 현황 조사 및 분석)

  • Su-Ran Lim;Jung-Hwan Park;Ji-Yeun Park;Song-Yi Kim
    • Korean Journal of Acupuncture
    • /
    • v.40 no.4
    • /
    • pp.156-168
    • /
    • 2023
  • Objectives : This study aimed to determine the status of thermal stimulation devices approved in Korea for medical applications over the past 10 years, and based on this, to obtain insight for future thermal treatment in Korean medical institutions. Methods : We searched the item classification list entitled "Regulations on Medical Device Items and Rating by Item" from the Ministry of Food and Drug Safety Notice No. 2021-24, 2021 (Enforced March 19, 2021; www.mfds.go.kr) for individually licensed heaters using the terms "heat" and "heating". Results : We identified 17 items of thermal stimulation product group, of which 1,308 devices were licensed by February 4, 2022, and 53.2% of them (n=696) were devices with valid permits for distribution in Korea. Among the licensed devices, heating pad systems under/overlay (electric, home use) were approved the most, but combinational stimulator (for medical use, home use; Grade 2) accounted for the highest percentage among the current valid permission. Moxibustion apparatuses were licensed separately for electrical use and non-electrical use, and occupied a low percentage of the total devices. We analyzed 307 devices that were accompanied by technical documents and found that the heat sources were wires in 145 (47.2%), infrared rays in 44 (14.3%) and ultrasonic waves in 42 (13.7%) devices. Most (83.1%) devices were used for pain relief, while other applications included beauty, cancer treatment, maintenance of infant body temperature, and healing fractures. Conclusions : Thermal stimulation devices accounted for about 0.9% of all medical devices, and among them, combinational stimulators and heating pad systems under/overlay had the most valid permits. Thermal stimulation devices using heating wires and infrared rays were the most prevalent, and most were used to relieve pain. In order to develop a range of thermal stimulation devices that can be utilized in Korean medical institutions, it is imperative that they have potential applications beyond pain management, addressing various medical purposes. To achieve this, foundational research is necessary to effectively apply diverse heat sources based on medical objectives.

Detection Fastener Defect using Semi Supervised Learning and Transfer Learning (준지도 학습과 전이 학습을 이용한 선로 체결 장치 결함 검출)

  • Sangmin Lee;Seokmin Han
    • Journal of Internet Computing and Services
    • /
    • v.24 no.6
    • /
    • pp.91-98
    • /
    • 2023
  • Recently, according to development of artificial intelligence, a wide range of industry being automatic and optimized. Also we can find out some research of using supervised learning for deteceting defect of railway in domestic rail industry. However, there are structures other than rails on the track, and the fastener is a device that binds the rail to other structures, and periodic inspections are required to prevent safety accidents. In this paper, we present a method of reducing cost for labeling using semi-supervised and transfer model trained on rail fastener data. We use Resnet50 as the backbone network pretrained on ImageNet. At first we randomly take training data from unlabeled data and then labeled that data to train model. After predict unlabeled data by trained model, we adopted a method of adding the data with the highest probability for each class to the training data by a predetermined size. Futhermore, we also conducted some experiments to investigate the influence of the number of initially labeled data. As a result of the experiment, model reaches 92% accuracy which has a performance difference of around 5% compared to supervised learning. This is expected to improve the performance of the classifier by using relatively few labels without additional labeling processes through the proposed method.

A Study on Real-Time Monitoring for Moisture Measurement of Organic Samples inside a Drying Oven using Arduino Based on Open-Source (오픈 소스 기반의 아두이노를 이용한 건조기 내 유기 시료의 실시간 수분측정 모니터링에 관한 연구)

  • Kim, Jeong-hun
    • Journal of Venture Innovation
    • /
    • v.5 no.2
    • /
    • pp.85-99
    • /
    • 2022
  • Dryers becoming commercially available for experimental and industrial use are classified to general drying oven, hot-air dryer, vacuum dryer, freezing dryer, etc. and kinds of them are various from the function, size and volume, etc. But the moisture measurement is not applied although it is important factor for the quality control and the performance improvement of products, and then now is very passive because the weight is weighed arbitrarily after dry-end. Generally the method for measuring moisture is divided by a direct measurement method and a indirect measurement method, and the former such as the change of weight or volume on the front and rear of separation of moisture, etc. is mainly used. Relatively a indirect measurement is very limited to apply due to utilize measurement apparatuses using temperature conductivity and micro-wave etc. In this research, we easily designed the moisture measurement system using the open-source based Arduino, and monitored moisture fluctuations and weight profiles in the real-time without the effect of external environment. Concretely the temperature-humidity and load cell sensors were packaged into a drying oven and the various change values were measured, and their sensors capable to operate 60℃ and 80℃ were selected to suitable for the moisture sensitive materials and the food dry. And also the performance safety using the organic samples of banana, pear, sawdust could be secured because the changes of evaporation rate as the dry time and temperature, and the measurement values of load cell appeared stable response characteristics through repeated experiments. Hereafter we judge that the reliability can be improved increasingly through the expansion of temperature-humidity range and the comparative analysis with CFD(Computational Fluid Dynamics) program.

Histogram-Based Singular Value Decomposition for Object Identification and Tracking (객체 식별 및 추적을 위한 히스토그램 기반 특이값 분해)

  • Ye-yeon Kang;Jeong-Min Park;HoonJoon Kouh;Kyungyong Chung
    • Journal of Internet Computing and Services
    • /
    • v.24 no.5
    • /
    • pp.29-35
    • /
    • 2023
  • CCTV is used for various purposes such as crime prevention, public safety reinforcement, and traffic management. However, as the range and resolution of the camera improve, there is a risk of exposing personal information in the video. Therefore, there is a need for new technologies that can identify individuals while protecting personal information in images. In this paper, we propose histogram-based singular value decomposition for object identification and tracking. The proposed method distinguishes different objects present in the image using color information of the object. For object recognition, YOLO and DeepSORT are used to detect and extract people present in the image. Color values are extracted with a black-and-white histogram using location information of the detected person. Singular value decomposition is used to extract and use only meaningful information among the extracted color values. When using singular value decomposition, the accuracy of object color extraction is increased by using the average of the upper singular value in the result. Color information extracted using singular value decomposition is compared with colors present in other images, and the same person present in different images is detected. Euclidean distance is used for color information comparison, and Top-N is used for accuracy evaluation. As a result of the evaluation, when detecting the same person using a black-and-white histogram and singular value decomposition, it recorded a maximum of 100% to a minimum of 74%.

Study on the Occurrence of Tunnel Damage when a Large-scale Fault Zone Exists at the Top and Bottom of a Tunnel (대규모 단층대가 터널 상하부에 존재하는 조건에서 터널 변상 사례 연구)

  • Jeongyong Lee;Seungho Lee;Nagyoung Kim
    • Journal of the Korean GEO-environmental Society
    • /
    • v.24 no.12
    • /
    • pp.53-60
    • /
    • 2023
  • Recently, along with the improvement of high-speed rail and road design speed, the proportion of tunnel construction work is increasing proportionally. In particular, the construction of long tunnels is rapidly increasing due to the mountainous terrain of our country. In this way, due to the trend of tunnels becoming longer, it is difficult to design and construct tunnels by avoiding fault zones. In the case of tunnel construction in mountainous areas, ground investigation is often difficult even during design due to the topographical conditions, making precise ground investigation difficult, and as a result, the upper part of the tunnel is damaged during tunnel construction. When fault zones, which are vulnerable to weathering, exist, the stability of the tunnel during excavation is directly affected by the fault zone distribution, strength characteristics, and groundwater distribution range. In particular, when a fault zone is distributed in the upper part of a tunnel, damage such as tunnel collapse and excessive displacement may occur, and in order to prevent this in advance, countermeasures must be established through analysis of similar cases. Therefore, in this study, when a large-scale fault zone exists in the upper part of a tunnel, the relationship and characteristics of damage to the tunnel structure were analyzed.

Estimation Method of Resilience Pads Spring Stiffness for Sleeper Floating Tracks based on Track Vibration (궤도 진동기반의 침목플로팅궤도 침목방진패드 스프링강성 추정 기법 연구)

  • Jung-Youl Choi;Sang-Wook Park;Jee-Seung Chung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.6
    • /
    • pp.1057-1063
    • /
    • 2023
  • The urban railway sleeper floating track, the subject of this study, is an anti-vibration track to reduce vibration transmitted to the structure. currently, the replacement cycle of resilience pad for sleeper floating tracks is set and operated based on load. however, most previous studies were conducted on load-based structural safety aspects, such as fatigue life evaluation of sleeper anti-vibration pads and increase in track impact coefficient and track support stiffness due to increase in spring stiffness. therefore, in this study, we measure the vibration acceleration of the ballast for each analysis section and use the results of 7 million fatigue tests to calculate the spring stiffness of the resilience pad for each section. the spring stiffness of the resilience pad calculated for each section was set as the analysis data and the concrete vibration acceleration was derived analytically. the adequacy of analysis modeling was verified as the analyzed concrete bed vibration acceleration for each section was within the field-measured concrete bed vibration acceleration range. using the vibration acceleration curve according to the derived spring stiffness change, the spring stiffness of the resilience pad is estimated from the measured vibration acceleration. therefore, we would like to present a technique that can estimate the spring stiffness of resilience pad of a running track using the vibration acceleration of the measured concrete bed.

Evaluation of Harmless Crack Size of SCM822H Steel by Double Shot Peening (이중 쇼트 피닝에 의한 SCM822H 강의 무해화 균열 크기 평가)

  • Jin-Woo Choi;Seo-Hyun Yun;Yung-Kug Kwon;Gum-Hwa Lee;Ki-Woo, Nam
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.6_2
    • /
    • pp.1011-1017
    • /
    • 2023
  • In this study, the harmless crack size (ahml) by double shot peening (DSP) using shot balls with different diameters was evaluated on carburized, quenched-tempered SCM822H steel. The minimum crack size (aNDI) detectable by non-destructive inspection was also evaluated. The relationship between the crack size (a25,50) that reduces the fatigue limit by 25% and 50% and ahml was evaluated. The residual stress of DSP was greater in SP(0.6+0.08) than SP(0.8+0.08) and appeared deeper in the depth direction. In addition, the hardness below the surface appeared larger. The fatigue limit of DSP increased 2.07 times and 1.95 times compared to non-SP. All ahml of the DSP specimen was determined at the depth (a). The compressive residual stress distribution affects ahml, and the ahml of SP(0.6+0.08), which has a large compressive residual stress and a high fatigue limit, appeared large. ahml of SP(0.6+0.08) introduced deeper than the residual stress of SP(0.8+0.08) is larger in the range of As=1.0-0.3. Since the residual stress in the thickness direction has a greater effect on ahml than the residual stress at the surface, it is necessary to introduce it more deeply. The relation of ahml, a25,50, and aNDI were evaluated in the point for safety and reliability.

Opto-Mechanical Detailed Design of the G-CLEF Flexure Control Camera

  • Jae Sok Oh;Chan Park;Kang-Min Kim;Heeyoung Oh;UeeJeong Jeong;Moo-Young Chun;Young Sam Yu;Sungho Lee;Jeong-Gyun Jang;Bi-Ho Jang;Sung-Joon Park;Jihun Kim;Yunjong Kim;Andrew Szentgyorgyi;Stuart McMuldroch;William Podgorski;Ian Evans;Mark Mueller;Alan Uomoto;Jeffrey Crane;Tyson Hare
    • Journal of The Korean Astronomical Society
    • /
    • v.56 no.2
    • /
    • pp.169-185
    • /
    • 2023
  • The GMT-Consortium Large Earth Finder (G-CLEF) is the first instrument for the Giant Magellan Telescope (GMT). G-CLEF is a fiber feed, optical band echelle spectrograph that is capable of extremely precise radial velocity measurement. G-CLEF Flexure Control Camera (FCC) is included as a part in G-CLEF Front End Assembly (GCFEA), which monitors the field images focused on a fiber mirror to control the flexure and the focus errors within GCFEA. FCC consists of an optical bench on which five optical components are installed. The order of the optical train is: a collimator, neutral density filters, a focus analyzer, a reimager and a detector (Andor iKon-L 936 CCD camera). The collimator consists of a triplet lens and receives the beam reflected by a fiber mirror. The neutral density filters make it possible a broad range star brightness as a target or a guide. The focus analyzer is used to measure a focus offset. The reimager focuses the beam from the collimator onto the CCD detector focal plane. The detector module includes a linear translator and a field de-rotator. We performed thermoelastic stress analysis for lenses and their mounts to confirm the physical safety of the lens materials. We also conducted the global structure analysis for various gravitational orientations to verify the image stability requirement during the operation of the telescope and the instrument. In this article, we present the opto-mechanical detailed design of G-CLEF FCC and describe the consequence of the numerical finite element analyses for the design.

Optimizing analytical method in Health Functional Food code with adjustable chromatographic parameters: A case study of vitamin C (건강기능식품공전 시험법의 크로마토그래프법 조건의 조정 및 비타민C에 대한 적용성 평가 연구)

  • Junghoon Shin;Yooseong Jeong;Yong Seok Choi;Sang Beom Han;Dong-Kyu Lee
    • Analytical Science and Technology
    • /
    • v.37 no.3
    • /
    • pp.143-154
    • /
    • 2024
  • In this study, we improved the vitamin C test method and reviewed data on the adjustable range of chromatography conditions for quantification. First, we adjusted the mobile phase conditions such as solvent composition, salt concentration, pH and column temperature and in particular, it was confirmed through an improved test method that the peak derived from the buffer solution could be clearly separated from the target component, vitamin C by adjusting the pH. The retention time of vitamin C was partially changed by adjusting the column diameter, length and particle size but the number of theoretical plates indicated similar values and did not affect the separation and quantitative analysis of the target component. The flow rate according to the column specifications was derived from the equation proposed by the U.S. FDA (Food and Drug administration) and the Korean MFDS (Ministry of Food and Drug Safety), and evaluation of the applicability to vitamin complexes showed high selectivity for vitamin C even with altered stationary phase conditions and flow rates. In conclusion, vitamin C can be optimally separated and detected by changing the chromatographic method conditions and it was confirmed that the mobile and stationary phase conditions of liquid chromatography can be slightly adjusted in case the assay method uses an isocratic elution.