• Title/Summary/Keyword: Range Measurement

Search Result 4,376, Processing Time 0.034 seconds

Location of pressure sensing holes in MPA flowmeter and discharge coefficients (MPA 유량계 압력감지공의 위치와 유출계수)

  • Kim, Raymond K.;Choi, Sung Kil
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.160-165
    • /
    • 2004
  • MPA (Multi-Point Averaging) flow element is a new type of differential pressure (DP) flow-sensing device that was developed by Seojin Instech to improve the operating characteristics of the conventional Averaging Pilot Tube (APT) flow elements. Operating characteristics of a flowmeter in general can be defined in terms of measurement accuracy and range. Improvement of accuracy and expanding the range of flow measurement were the two main objectives of the development. To achieve these dual objectives several upstream and downstream pressure-sensing holes were placed in MPA flow element. During the course of the development it was found that certain arrangements of the pressure-sensing holes improved measurement accuracy but did not expand operating flow range of Averaging Pilot Tubes. Development tests were performed with water between Reynolds number of 50,000 and 1,000,000 in the four-inch test line at the Alden Research Laboratory, U.S.A. Purpose of this paper is to present the relationship between the various locations of the pressure-sensing holes and the performance characteristics of MPA flow element. Furthermore, the operating characteristics of the best performing MPA are compared with those of typical orifice and APT.

  • PDF

Development of the laser measurement system for the wide output power range (광범위 출력 측정이 가능한 레이저 계측장치 개발)

  • Hwang Daeseok;Lee Young-Woo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.8
    • /
    • pp.1799-1804
    • /
    • 2005
  • We have developed and estimated the measurement system of $CO_2$ and Nd:YAG laser power of wide range. The absorber is made of gold-plated copper cavity. The calibration heater is using a manganin(CuMn12Ni) coil, and output power is measured by using or resistance bridge with composed manganin and copper coil. Developed system can measure 5${\~}$1000W laser output power range. Calibration factors are 489.13J/mV at 100W and 497.04(J/mV) at 500W. correction factors are 0.99 at 100W and 1.006 at 500W.

Assessment of the Implementation of a Neutron Measurement System During the Commissioning of the Jordan Research and Training Reactor

  • Bae, Sanghoon;Suh, Sangmun;Cha, Hanju
    • Nuclear Engineering and Technology
    • /
    • v.49 no.3
    • /
    • pp.504-516
    • /
    • 2017
  • The Jordan Research and Training Reactor (JRTR) is the first research reactor in Jordan, the commissioning of which is ongoing. The reactor is a 5-MWth, open-pool type, light-water-moderated, and cooled reactor with a heavy water reflector system. The neutron measurement system (NMS) applied to the JRTR employs a wide-range fission chamber that can cover from source range to power range. A high-sensitivity boron trifluoride counter was added to obtain more accurate measurements of the neutron signals and to calibrate the log power signals; the NMS has a major role in the entire commissioning stage. However, few case studies exist concerning the application of the NMS to a research reactor. This study introduces the features of the NMS and the boron trifluoride counter in the JRTR and shares valuable experiences from lessons learned from the system installation to its early commissioning. In particular, the background noise relative to the signal-to-noise ratio and the NMS signal interlock are elaborated. The results of the count rates with the neutron source and the effects of the discriminator threshold are summarized.

Design of Continuous Passive Motion Medical Device System with Range of Motion Measurement Function (관절가동범위 측정 기능을 갖는 연속수동운동 의료기기 시스템 설계)

  • Kang Won Lee;Min Soo Park;Do Woo Yu;Oh Yang;Chang Ho Lee
    • Journal of the Semiconductor & Display Technology
    • /
    • v.22 no.4
    • /
    • pp.87-92
    • /
    • 2023
  • As the elderly population increases, the number of patients with various joint diseases, including degenerative arthritis, is steadily increasing. CPM medical devices are needed to effectively treat degenerative arthritis that is common in the elderly population. Domestic CPM medical devices have limited functions and are highly dependent on imports for expensive imported medical devices. To solve this problem, we designed a ROM measurement function using a current sensor that is not present in existing composite joint CPM medical devices. The algorithm was designed using the fact that the force caused by joint stiffness greatly increases the current flowing through the DC motor. In addition, the need for digital healthcare in the medical field is gradually expanding as the proportion of chronically ill patients increases due to the spread of the non-face-to-face economy due to COVID-19 and the aging population. Therefore, this paper aims to improve the performance of CPM medical devices by allowing real-time confirmation of rehabilitation exercise information and operation range measurement results in accordance with digital healthcare trends through a Bluetooth application developed as an Android studio.

  • PDF

A Study on the Error Detection of Attached Cadastral Maps using GIS (GIS를 이용한 연속지적도 오류검증 방안)

  • Jung, Gu-Ha;Jun, Chul-Min;Koh, Jun-Hwan;Park, Yu-Ri
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2007.04a
    • /
    • pp.243-248
    • /
    • 2007
  • This study proposed a procedure to improve the error defection of attached cadastral maps using digital map data. In addition, this study also provided the direction for the accuracy improvement of attached cadastral maps by comparing analysis methods. - such as centroid, Lee Sallee shape index, and area index. The analysis is performed as follows. First, by using centroid measurement, the center point of cadastral maps and attached cadastral maps are compared. Secondly by using Lee Sallee shape measurement, the location accuracy of range area is investigated. Thirdly, by using area measurement, the range area within allowable error scope is verified. Based on analysis, the discrepancy between cadastral maps and the attacked cadastral maps are detected as follows; 98.2% from Lee Sallee shape index, 41.8% from centroid, 15.4% from area index in the whole error.

  • PDF

A geometric analysis of range measurement error (거리 영상 측정 오차의 기하학적 분석)

  • 윤강식;이병욱;박래홍
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.6
    • /
    • pp.1259-1265
    • /
    • 1997
  • We investigate depth measurement error of a range finder based on triangulation method. Geometric analysis resulted in intuitive understanding of the error sensitivity. We show that the depth error is propostional to the distance between the object andthe camera. The measurement value has the highest accuracy when the line connecting the focal point of the camera and the object is perpendicular to the line joining the object and the light source of herange finder. Also we analyze the error using a perturbation method and verify that the results are identical through an experiment.

  • PDF

A Study on the Measurement and Analysis of Whirling Vibration Behavior of Marine Propulsion Shafting System using Gap-sensors

  • Sun, Jin-Suk;Han, Tae-Min;Lee, Kang-Ki;Kim, Ue-Kan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.2
    • /
    • pp.130-135
    • /
    • 2015
  • Recently, as a result of the application of large and multi-blade propellers with high efficiency for large vessels, the vertical bending stiffness of propulsion shafting system tends to be declined. For some specific vessels, the shaft arrangement leads to the forward stern tube bearing to be omitted, decreasing vertical bending stiffness. In this respect, decreased vertical bending stiffness causes the problem which is the blade order resonance frequency to be placed within the operational rpm range of propulsion shafting system. To verify whirling vibration, the measurement should be carried out covering from operating rpm up to target rpm, however, the range is un-measurable generally. In order to resolve the measurement issue, this study shows the measuring method and the assessment method of relevant natural frequency of whiling vibration by using measured harmonic order component of whirling vibration.

Study on the partially premixed flames produced by a coflow burner as temperature calibration source (동축류 버너에서 생성된 부분 예혼합 화염을 이용한 화염 온도 측정 검정원 연구)

  • Park, Chul-Woung;Hahn, Jae-Won;Shin, Hyun-Dong
    • 한국연소학회:학술대회논문집
    • /
    • 2000.12a
    • /
    • pp.160-167
    • /
    • 2000
  • We investigated a uniform temperature zone, produced by double flame structure of a coflow CH4/air partially premixed flame, to be used as a temperature calibration source for laser diagnostics. A broadband N2 CARS(coherent anti-Stokes Raman spectroscopy) system with a modeless laser was used for temperature measurement. When the stoichiometric ratio was 1.5, we found the uniform temperature zone in radial direction of the flame of which the averaged temperature was 2110 K with standard deviation 24 K. In the stoichiometric ratio range between 2.0 and 2.5, we found very stable temperature-varying zones in vertical direction at the center of the flame. The size of the zone was approximately 15 mm and it covered a temperature range from 300 K to 1900 K. We also suggest that this zone can be used as a calibration source for 2-D PLIF(planar laser induced flurescence) temperature measurement.

  • PDF

Dynamical Characteristics of a Fiber-Optic Strain Gauge by a Single-Mode Fiber-Optic Mach-Zehnder Interferometer (단일모드 광섬유 Mach-Zehnder 간섭계를 이용한 광섬유 스트레인 게이지의 동적 특성)

  • 이기완;홍봉식
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.27 no.5
    • /
    • pp.793-801
    • /
    • 1990
  • A single mode fiber-optic Mach-Zehnder interferometer for the measurement of strain is described. A fiber-optic strain gauge with great resolution and wide measurement range is realized. In order to varify the dynamic response, the measurements of strain below 1涅 with frequency range 5-50Hz are compared with a semiconductor strain gauge. We report theoretical evaluation for mechanical analysis, PZT-plate, the phase change in a fiber-optic strain gauge and a semiconductor strain gauge. The dynamical characteristics of a fiber-optic strain gauge and a semiconductor strain gauge output siganl show equivalent behavior. This result is shown in very good usage as the dynamical measurement of the low strain below 1涅 by this system.

  • PDF

A GPS/DR Integration Scheme using Carrier Measurements (반송파 정보를 이용한 GPS/DR 통합 방법)

  • Seo, Hung-Seok;Sung, Tae-Kyung;Lee, Sang-Jeong
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.10
    • /
    • pp.1279-1286
    • /
    • 1999
  • In conventional GPS/DR integration schemes, the GPS position (or pseudo-range) information is used in calibrating DR sensors. In those schemes, however, an inaccurate calibration may degrade the position accuracy when the GPS measurement is not available. This paper presents a new integration scheme where the GPS velocity information is used in calibrating DR sensors. Also proposed is a new error model of DR sensors for calibrating the bias error and the tilt error in dynamic environments. The proposed model makes it possible that the errors of both the DR sensor parameters and the velocity are calibrated using the GPS carrier-based velocity(or the pseudo-range rate) measurement while the DR position error is calibrated using the GPS position measurement. Since the DR sensors are calibrated accurately, the positioning accuracy is drastically improved when the GPS measurements are unavailable.

  • PDF