• Title/Summary/Keyword: Range Difference

Search Result 5,069, Processing Time 0.029 seconds

A Myometric and Electromyographic Analysis of Hip Abductor Musculature in Healthy Right-Handed Persons (股關節外轉の時の中臀筋の筋力及び活動電位の變化に關する硏究)

  • Kwon, Hyuk-Cheol
    • Physical Therapy Korea
    • /
    • v.5 no.4
    • /
    • pp.41-51
    • /
    • 1998
  • The right hip abductor musculature has been reported to demonstrate "stretch weakness" attributable to chronic elongation imposed by standing posture common to right-handed healthy persons. Kendall and associates have described the concept of "stretch weakness",. The purpose of this study was to assess isometric hip abduction torque and surface electromyographic activity (using MYOMED 432) in a sample of 40 healthy right-handed persons (20 male, 20 female), all of whom agreed to participate in the study, and compare side difference in the hip abductor musculature. In order to assure the statistical significance of the results, the paired t test was applied at the .05 level of significance. The results were as follows: 1) The difference in apparent leg length of right and left legs was significant at the .05 level. 2) There was a significant difference between right and left pelvic height (standing position) at the 05 level measurements, and scapula height at the .05 level. 3) Power measurements and action potentials of right hip abductor were greater than the left hip abductor regardless of the range of joint motion (inner range, outer range) 4) The difference in muscle power and action potentials according to inner or outer range of both hip abductor were significant at the .05 level. 5) In supine during active left hip abduction, the appearance of action potentials in the right hip abductors is indicative of contra-lateral effect (p<.05) These results suggest: In healthy right-handed persons, the apparent leg length on the right is longer than on the left, and pelvic height is elevated on the right side. Muscle those and muscle action potentials of the right hip abductor are higher than those of the left hip abductor in the lengthened position. Therefore, the results in this study are contrary to Kendall's. This type of study should be carried out in many physical therapy departments.

  • PDF

Prediction of Fatigue Crack Initiation Direction around a Hole under Biaxial Loads Considering Phase Difference and Biaxiality (이축성과 위상차의 영향을 고려한 이축 하중하에서 구멍 주위에서의 피로 균열 발생 방향 예측)

  • Huh, Yong-Hak;Park, Pil-Ip;Kim, Dong-Jin
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.156-161
    • /
    • 2004
  • To predict the direction of the fatigue crack initiated from a hole under various types of biaxial fatigue loads with different phase difference and biaxiality, fatigue parameters were investigated. Axial and torsional biaxial fatigue loads were selected with the respective combination of five different phase differences of 0, 45, 90, 145 and 180 degrees and five biaxialities of 0, $1/{\sqrt{3}}$, 1, ${\sqrt{3}}$, ${\infty}$. Directions of the fatigue crack initiation around the hole were found to approach to the circumferential direction of the specimen with increment of the phase difference for fatigue tests with phase differences less than $90^{\circ}$. Whereas directions for tests with phase differences greater than $90^{\circ}$ went away from the circumferential direction and those were symmetric to the directions for tests with phase difference less than $90^{\circ}$. With increase of biaxilities, the fatigue crack initiated more apart from the circumferential direction of the specimen. These crack initiation direction were predicted using maximum tangential stress range and maximum shear stress range obtained at far-field and around the hole. Comparing these two stress parameters, The crack initiation direction can be successfully explained by using the direction of the maximum tangential stress range obtained around the hole and at far-field.

  • PDF

A Myometric and Electromyographic Analysis of Hip Abductor Musculature in Healthy Right-Handed Persons (고관절 외전시 중둔근의 근력 및 활동전위 변화에 관한 연구)

  • Kwon Hyuk-Cheol
    • The Journal of Korean Physical Therapy
    • /
    • v.2 no.1
    • /
    • pp.35-46
    • /
    • 1990
  • The right hip adbuctor musculature has been reported to demonstrate 'stretch weakness' attributable to chronic elongation imposed by standing posture common to right-handed healthy persons. Kendall and associates have described the concept of 'stretch weakness'. The purpose of this study was to assess isometric hip abduction torque and surface electro-myographic activity (using MYOMED 432) in a sample of 40 healthy right-handed persons (20 male, 20 female), all of whom agreed to participate in the study, and compare side difference in the hip abductor musculature. In order to assure the statistical significance of the results, the paired t-test was applied at the .05 level of significance. The results were as follows : 1. The difference in apparent leg length of right and left legs was significant at the .05 leve1. 2. There was a significant difference between right and left pelvic height (standing position) at the .005 level measurements, and scapula height at the .05 level. 3. Power measurements and action potentials of right hip adbuctor were greater than the left hip adbuctor regardless of the range of joint motion (inner range, outer range). 4. The difference in muscle power and action potentials according to inner or outer range of both hip abductor were significant at the .05 level. 5. In supine during active left hip abduction, the appearance of action potentials in the right hip abductors is indicative of contra-lateral effect (p<.005). These results suggest : In healthy right-handed persons. the apparent leg length on the right is longer than on the left, and pelvic height is elevated on the right side. Muscle torque and muscle action potentials of the right hip adbuctor art higher than those of the hip abductor in the lengthened position. Therefore, the results in this study are contrary to Kendall's. This type of study should be carried out in many physical therapy departments.

  • PDF

Impact of Firefighters' Protective Clothing and Equipment on Upper Body Range of Motion (소방용 방화복 및 방화 장비에 따른 상반신 관절 각도의 동작 범위 연구)

  • Kim, Seonyoung;Park, Huiju
    • Fashion & Textile Research Journal
    • /
    • v.17 no.4
    • /
    • pp.635-645
    • /
    • 2015
  • This study analyzed the range of motion of upper body in different configurations of firefighters' protective clothing and equipment. The purpose of this study was to understand the influence of firefighters' protective clothing and equipment over upper body motion in order to improve design of firefighters' protective clothing and equipment. 12 firefighters' upper body range of motion was analyzed while performing standing and walking trials in five different garment configurations including turnout ensemble, fire boots and the self-contained breathing apparatus. Analysis of upper body range of motion included spinal joints of L5S1, L4L3, T1C7, and C1Head. During standing trials, garment configurations caused a significant difference in range of motions at joints of L5S1, L4L3, T1C7, and C1Head. Analysis on the mean of range of motions at L5S1 and L4L3, showed that firefighters' waist bent forward significantly to a greater extent while they wore a self-contained breathing apparatus. A significantly increased range of motion was found for T1C7 and C1Head while carrying a self-contained breathing apparatus, which indicated an increase in the extension of the trunk and neck backward to stand upright and look squarely. A significant difference in range of motion was also found for L5S1 and L4L3 during walking trials.

Treatment of Old Achilles Tendon Rupture using Modified Flexor Hallucis Longus Tendon Transfer (변형된 장 족무지 굴건 이전술을 이용한 진구성 아킬레스 건 파열의 치료)

  • Kim, Hyong-Nyun;Suh, Il-Woo;Park, Yong-Wook
    • Journal of Korean Foot and Ankle Society
    • /
    • v.13 no.2
    • /
    • pp.133-137
    • /
    • 2009
  • Purpose: The purpose of this study was to evaluate the clinical results of the old Achilles tendon rupture treated with modified flexor hallucis longus (FHL) tendon transfer. Materials and Methods: Seventeen patients with old Achilles tendon rupture treated with modified FHL tendon transfer between March 2004 and February 2008 were enrolled in this study. Technically FHL was pass through the distal portion of the ruptured tendon instead of the drilled hole made on the calcaneus. The mean age of the patients was 37 years (range, 22~67 years), mean follow-up period was 28 months (range, 12~30 months). Patients' subjective satisfaction, calf circumferential diameter, range of motion of ankle and AOFAS ankle-hind foot score and Arner-Lidholm score was evaluated. Results: The average gap between the ruptured tendon was 52 mm (range, 47~56 mm). The AOFAS score improved from 47 pre-operatively to 91 points at the last follow-up. Sixteen patients were satisfied with the result free from discomfort, a patient had mild discomfort who had DM. fourteen patients had decreased range of motion less than 5 degrees while 2 patients had more than 7 degrees decrease compared to the intact side but had no discomfort in daily activities. Nine patients had less than 1 cm calf circumferential diameter difference and 7 patients had 1 to 3 cm diameter difference compared to the intact side. One who had more than 3 cm diameter difference had deteriorated muscle strength. Conclusion: Modified FHL tendon transfer can be a useful technique for the treatment of old Achilles tendon rupture when the gap is with large gap placed too proximal.

  • PDF

The Influence of Augmented Reality based Knee Exercise in Short Period on Range of Motion and Balance - Pilot study (증강현실 기반의 단기간 무릎운동이 관절가동범위와 균형에 미치는 영향 - 예비연구)

  • Im, JongHun;Yu, JaeHo
    • Archives of Orthopedic and Sports Physical Therapy
    • /
    • v.14 no.2
    • /
    • pp.1-8
    • /
    • 2018
  • Purpose: This study investigated the effect of the augmented reality (AR)-based knee joint short period exercise program and used a motion analyzer with a 3D camera to determine the range of motion and dynamic balance and further investigate the effects of therapeutic exercise on patients. Methods: This study used AR-based motion analysis and a Y-balance test to measure the range of motion (ROM) of each joint: the hip joint and the knee joint. After the measurements, an exercise program was applied to the subjects, using the knee motion program function, and the muscles of the quadriceps femoris and the hamstring were stretched or strengthened. Results: Our results showed knee joint extension at the dominant hip joint flexion position. While there was no significant difference (p>.05) at this position, there were significant differences in the non-dominant hips, unbalanced knee joint flexion, and superior knee joint flexion (p<.05). The Y-balance test using the non-dominant leg supported by the dominant legs showed that the absolute reach was $69.70{\pm}7.06cm$ before the exercise, and the absolute reach after the exercise was $77.56{\pm}6.09cm$ (p<.05). Conclusions: There was a significant difference when the movement of the lower limbs supported the superior limbs, and a significant difference was found in the ROM when the non-dominant side supported the dominant side. Therefore, the AR-based exercise program improves the balance of the human body and the range of motion of the joints, and research that aims to improve patients abilities should continue.

A Research on Time-Dependent Fundamental Frequency Variations after Waking up in the Morning (기상 후 시간에 따른 음도 변화에 대한 연구)

  • Ahn, Jong-Bok;Nam, Hyun-Wook;Jeong, Ok-Ran
    • Speech Sciences
    • /
    • v.15 no.2
    • /
    • pp.169-176
    • /
    • 2008
  • This study was intended to analyze difference of vocal folds movements between upon wakeup and in several hours later in the morning. The difference of vocal fold movements was compared with fundamental frequency and a range of fundamental frequencies from maximum to minimum. The participants were 30 female adults between 20 and 29 years old. Voice samples were collected from their reading sentence (Jeong, 1993). The first sampling was conducted within 5 minutes after wakeup, while the second on 1 hour after the first sampling. Finally, the third voice sample was collected on 6 hours after the second sampling. The results of this study were as follows: First, fundamental frequency of the participants were by hour significantly time-dependent(F=7.843). Post-hoc multiple comparison (LSD) was conducted to determine when the difference could be observed. The result showed significant differences between upon wakeup and 6 hours later (p< .001) and between 1 hour later and 6 hours later (p< .05). Second, there were a significantly time-dependent ranges of fundamental frequencies of participants by hour (F=3.130). According to the results of the LSD analysis the significant differences in range of fundamental frequencies were found between upon wakeup and 1 hour later and also between wakeup and 6 hours later (p< .05). The results above indicate that vocal fold movements upon wakeup is different from those of several hours later.

  • PDF

Development of Small Size Coriolis Mass Flowmeter (소형 코리올리 질량 유량계의 개발)

  • Lim Ki-Won;Ji Jueng-Keun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.6 s.249
    • /
    • pp.497-504
    • /
    • 2006
  • A Coriolis mass flowmeter(CMF), which has U-Shaped unique measurins tube was developed fo. direct mass flow measurement. In order to convert the time difference between two measuring tubes motion into mass flowrate and flow quantity, a signal processing circuit, as a part of CMF, was also developed. The CMF was designed as the 15 mm nominal diameter of pipe connection and the 8 mm stainless steel(sus 316) pipe was used for measuring tube. To maximize the flow signal(time difference) from the measuring tubes, the natural frequency of measuring tube was adjusted as 220 Hz, which is same as the frequency of exciter. The maximum displacement at the end of the measuring tube was measured as 0.05 mm and the maximum time difference between two measuring tubes was observed as $20{\mu}s$, which was proper for discrimination and measuring range of CMF. The developed CMF was tested against the gravimetric flowmeter calibrator in the range of 3 kg/min and 30 kg/min. The results showed that the CMF has good linearity and repeatability in the tested flow range. Large size of CMF base on the current study experience will be developed.

Analysis and Comparison of Rock Spectroscopic Information Using Drone-Based Hyperspectral Sensor

  • Lee, So-Jin;Jeong, Gyo-Cheol;Kim, Jong-Tae
    • The Journal of Engineering Geology
    • /
    • v.31 no.4
    • /
    • pp.479-492
    • /
    • 2021
  • We conducted a fundamental study on geological and rock detection via drone-based hyperspectral imaging on various types of small rock samples and interpreted the obtained information to compare and classify rocks. Further, we performed hyperspectral imaging on ten rocks, and compared the peak data value and reflectance of rocks. Results showed a difference in the reflectance and data value of the rocks, indicating that the rock colors and minerals vary or the reflectance is different owing to the luster of the surface. Among the rocks, limestone used for hyperspectral imaging is grayish white, inverted rock contains various sizes and colors in the dark red matrix, and granite comprises colorless minerals, such as white, black, gray, and colored minerals, resulting in a difference in reflectance. The reflectance of the visible ray range in ten rocks was 16.00~85.78%, in the near infrared ray range, the average reflectance was 23.94~86.43%, the lowest in basalt and highest in marble in both cases. This is because of the pores in basalt, which caused the difference in reflectance.

Fatigue Crack Initiation around a Hole under Out-of-phase Biaxial Loading (이상 이축 하중 하에서 구멍 주위에서의 피로 균열 발생)

  • Huh, Yong-Hak;Park, Pi-Lip;Kim, Dong-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.10
    • /
    • pp.1695-1702
    • /
    • 2003
  • Fatigue crack initiation around a hole subjected to biaxial fatigue loads with a phase difference was investigated. Axial and torsional biaxial fatigue loads with different phase differences and biaxiality of 1/√3 were applied to thin-walled tubular specimens. Five phase differences of 0, 45, 90, 145 and 180 degrees were selected. Directions of the fatigue crack initiation around the hole were found to approach to the circumferential direction of the specimen with increment of the phase difference for fatigue tests with phase differences less than 90$^{\circ}$. Whereas directions for tests with phase differences greater than 90$^{\circ}$ got away from the circumferential direction and those were symmetric to the directions for tests with phase difference less than 90. . Furthermore, it was shown that the fatigue initiation life decreased with increment of phase difference for fatigue tests with phase differences less than 90$^{\circ}$, but it increased for tests with phase difference greater than 90$^{\circ}$. The crack initiation direction can be successfully explained by using the direction of the maximum tangential stress range obtained around the hole and at far-field.