• Title/Summary/Keyword: Range Accuracy

Search Result 2,648, Processing Time 0.034 seconds

A Study on the Fitness of Adjustable Dental Impression Trays on the Chinese and Japanese (중국인과 일본인에 대한 가변형 치과 인상용 트레이의 적합성에 관한 연구)

  • Kang, Han-Joong;Lee, Jin-Han;Choi, Jong-In;Lee, In-Seop;Dong, Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.175-184
    • /
    • 2008
  • Purpose: This study was designed to investigate the fitness of adjustable dental impression trays on the Chinese and the Japanese. Material and methods: Initial design of the adjustable dental trays was developed from the results of the dental arch size of Korean adults. This design was applied to the CAD-CAM process in order to create tray model samples. Simple silicon-base molds were then replicated based on these sample models. Polyurethane injection into the silicon- base molds completed the process of creating a large number of test products. 60 Chinese dental students (male:30, female:30) from the Shanghai Second Medical University and 60 Japanese alumni from the Kumamoto high school (male:30, female:30) were selected for taking irreversible hydrocolloid impression with these trays. The width and length of the impression body were measured on several measuring points by Vernier caliper. The results were analyzed statistically to evaluate the fitness of the trays. Results: 1. Uniform impression material thickness was achieved on the Chinese and Japanese by controlling the width of the tray using stops and beveled guides. The material thickness was generally within the range of 3 mm to 6 mm. 2. In the maxillary tray of the Chinese, average thickness of the impression material of the labial vestibule of the incisal teeth was 6.2 mm, the canine was 5.9 mm and the midpalatal part 10.5 mm and the posterior palatal part 9.7 mm. These were relatively large values. 3. In the mandibular tray of the Chinese, average length of the impression material of the lingual vestibule of first, second premolar contact point was 8.9 mm, the incisal teeth was 7.8 mm and thickness of the labial part of canine was 6.8 mm and premolars 7.0 mm. These were relatively large values. 4. In the maxillary tray of the Japanese, average thickness of the impression material of the labial vestibule of the incisal teeth was 7.4 mm, the canine was 7.7 mm and the midpalatal part 9.1 mm. These were relatively large values. 5. In the mandibular tray of the Japanese, average thickness of the impression material of the labial vestibule of first, second premolar contact point was 8.4 mm, and thickness of the labial part of canine was 7.4 mm. These were relatively large values. Conclusion: This adjustable dental tray shows good accuracy to Korean because it was designed by the analysis of the dental arch size of Korean adult model. With this result, it can be applied to Chinese and Japanese, we can take more easy and accurate dental impressions.

Method Validation for the Determination of Eleutherosides and β-Glucan in Acanthopanax koreanum (탐라오가피의 Eleutheroside B, E 및 β-Glucan 함량 분석 및 분석법 검증)

  • Kim, Young-Hyun;Bae, Da-Bin;Park, Sun-Ok;Lee, Sang-Jong;Cho, Ok-Hyun;Lee, Ok-Hwan
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.42 no.9
    • /
    • pp.1419-1425
    • /
    • 2013
  • The aim of this study was to investigate the method validation for the determination of eleutherosides (B and E) and ${\beta}$-glucan in Acanthopanax (A.) koreanum. This medicinal plant reportedly mainly included eleutherosides which exhibit the pharmacological effects, and ${\beta}$-glucan substantially enhances the function of the immune system by activating macrophages. The specificity, linearity, precision, accuracy, limit of detection (LOD, S/N=3), and limit of quantification (LOQ, S/N=10) were measured by HPLC and enzymatic methods. Our results showed that the coefficient of calibration correlation ($R^2$) for eleutheroside B and E were 0.9997 and 0.9999, respectively. The limits of detection (LOD) for eleutheroside B and E were $0.050{\mu}g/mL$ and $0.025{\mu}g/mL$, respectively. The recovery rate of eleutheroside B and E were revealed in the high range of 100.66~110.04% and 94.26~111.62%, respectively. The inter-day precision of eleutheroside B and E in the root and stem in A. koreanum were 1.4~5.0% and 1.1~2.5%, respectively. The intra-day precision of eleutheroside B and E in the root and stem in A. koreanum were 2.8~2.9% and 0.4~1.1%, respectively. Furthermore, the inter-day and intra-day precision of ${\beta}$-glucan in the stem, leaf, and fruit of A. koreanum were 1.32~5.67% and 8.01~11.76%, respectively. In conclusion, the methods were validated for the detection of eleutherosides and ${\beta}$-glucan in A. koreanum.

Prediction of Correct Answer Rate and Identification of Significant Factors for CSAT English Test Based on Data Mining Techniques (데이터마이닝 기법을 활용한 대학수학능력시험 영어영역 정답률 예측 및 주요 요인 분석)

  • Park, Hee Jin;Jang, Kyoung Ye;Lee, Youn Ho;Kim, Woo Je;Kang, Pil Sung
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.4 no.11
    • /
    • pp.509-520
    • /
    • 2015
  • College Scholastic Ability Test(CSAT) is a primary test to evaluate the study achievement of high-school students and used by most universities for admission decision in South Korea. Because its level of difficulty is a significant issue to both students and universities, the government makes a huge effort to have a consistent difficulty level every year. However, the actual levels of difficulty have significantly fluctuated, which causes many problems with university admission. In this paper, we build two types of data-driven prediction models to predict correct answer rate and to identify significant factors for CSAT English test through accumulated test data of CSAT, unlike traditional methods depending on experts' judgments. Initially, we derive candidate question-specific factors that can influence the correct answer rate, such as the position, EBS-relation, readability, from the annual CSAT practices and CSAT for 10 years. In addition, we drive context-specific factors by employing topic modeling which identify the underlying topics over the text. Then, the correct answer rate is predicted by multiple linear regression and level of difficulty is predicted by classification tree. The experimental results show that 90% of accuracy can be achieved by the level of difficulty (difficult/easy) classification model, whereas the error rate for correct answer rate is below 16%. Points and problem category are found to be critical to predict the correct answer rate. In addition, the correct answer rate is also influenced by some of the topics discovered by topic modeling. Based on our study, it will be possible to predict the range of expected correct answer rate for both question-level and entire test-level, which will help CSAT examiners to control the level of difficulties.

The study of quantitative analytical method for pH and moisture of Hanji record paper using non-destructive FT-NIR spectroscopy (비파괴 분석 방법인 푸리에 변환 근적외선 분광 분석을 이용한 한지 기록물의 산성도 및 함수율 정량 분석 연구)

  • Shin, Yong-Min;Park, Soung-Be;Lee, Chang-Yong;Kim, Chan-Bong;Lee, Seong-Uk;Cho, Won-Bo;Kim, Hyo-Jin
    • Analytical Science and Technology
    • /
    • v.25 no.2
    • /
    • pp.121-126
    • /
    • 2012
  • It is essential to evaluate the quality of Hanji record paper without damaging the record paper by previous destructive methods. The samples were Hanji record paper produced in the 1900s. Near-infrared (NIR) spectrometer was used as a non destructive method for evaluating the quality of record papers. Fourier transform (FT) spectrometer was used with 12,500 to 4,000 $cm^{-1}$ wavenumber range for quantitative analysis and it has high accuracy and good signal-to-noise ratio. The acidity and moisture content of Hanji record paper were measured by integrating sphere as diffuse reflectance type. The acidity (pH) of chemical factors as a quality evaluated factor of Hanji was correlated to NIR spectrum. The NIR spectrum was pretreated to obtain the coefficients of optimum correlation. Multiplicative scatter correction (MSC) and First derivative of Savitzky-Golay were used as pretreated methods. The coefficients of optimum correlation were calculated by PLSR (partial least square regression). The correlation coefficients ($R^2$) of acidity had 0.92 on NIR spectra without pretreatment. Also the standard error of prediction (SEP) of pH was 0.24. And then the NIR spectra with pretreatment would have better correlation coefficient ($R^2$ = 0.98) and 0.19 as SEP on pH. For moisture contents, the linearity correlation without pretreatment was higher than the case with pretreatment (MSC, $1^{st}$ derivative). As the best result, the $R^2$ was 0.99 and SEP was 0.45. This indicates that it is highly proper to evaluate the quality of Hanji record papers speedily with integrated sphere and FT NIR analyzer as a non-destructive method.

Partial transmission block production for real efficient method of block and MLC (Partial transmission block 제작 시 real block과 MLC를 이용한 방법 중 효율적인 방법에 대한 고찰)

  • Choi JiMin;Park JuYoung;Ju SangGyu;Ahn JongHo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.2
    • /
    • pp.19-24
    • /
    • 2004
  • Introduction : The Vaginal, the urethra, the vulva and anal cancer avoid the many dose to femur head and the additional treatment is necessary in inguinal LN. The partial transmission block to use inguinal LN addition there is to a method which it treats and produce partial transmission block a method and the MLC which to it analyzes. Material & Methode : The Inguinal the LN treatment patient partial transmission it used block and the MLC in the object and with solid water phantom with the patient it reappeared the same depth. In order to analyze the error of the junction the EDR2 (Extended dose range, the Kodak and the U.S) it used the Film and it got film scanner it got the beam profile. The partial transmission block and the MLC bias characteristic, accuracy and stability of production for, it shared at hour and comparison it analyzed. Result : The partial the transmission block compares in the MLC and the block production is difficult and production hour also above 1 hours. The custom the block the place where it revises the error of the junction is a difficult problem. If use of the MLC the fabrication will be break and only the periodical calibration of the MLC it will do and it will be able to use easily. Conclusion : The Inguinal there is to LN treatment and partial transmission block and the MLC there is efficiency of each one but there is a place where the junction of block for partial transmission block the production hour is caught long and it fixes and a point where the control of the block is difficult. like this problem it transfers with the MLC and if it treats, it means the effective treatment will be possible.

  • PDF

The Individual Discrimination Location Tracking Technology for Multimodal Interaction at the Exhibition (전시 공간에서 다중 인터랙션을 위한 개인식별 위치 측위 기술 연구)

  • Jung, Hyun-Chul;Kim, Nam-Jin;Choi, Lee-Kwon
    • Journal of Intelligence and Information Systems
    • /
    • v.18 no.2
    • /
    • pp.19-28
    • /
    • 2012
  • After the internet era, we are moving to the ubiquitous society. Nowadays the people are interested in the multimodal interaction technology, which enables audience to naturally interact with the computing environment at the exhibitions such as gallery, museum, and park. Also, there are other attempts to provide additional service based on the location information of the audience, or to improve and deploy interaction between subjects and audience by analyzing the using pattern of the people. In order to provide multimodal interaction service to the audience at the exhibition, it is important to distinguish the individuals and trace their location and route. For the location tracking on the outside, GPS is widely used nowadays. GPS is able to get the real time location of the subjects moving fast, so this is one of the important technologies in the field requiring location tracking service. However, as GPS uses the location tracking method using satellites, the service cannot be used on the inside, because it cannot catch the satellite signal. For this reason, the studies about inside location tracking are going on using very short range communication service such as ZigBee, UWB, RFID, as well as using mobile communication network and wireless lan service. However these technologies have shortcomings in that the audience needs to use additional sensor device and it becomes difficult and expensive as the density of the target area gets higher. In addition, the usual exhibition environment has many obstacles for the network, which makes the performance of the system to fall. Above all these things, the biggest problem is that the interaction method using the devices based on the old technologies cannot provide natural service to the users. Plus the system uses sensor recognition method, so multiple users should equip the devices. Therefore, there is the limitation in the number of the users that can use the system simultaneously. In order to make up for these shortcomings, in this study we suggest a technology that gets the exact location information of the users through the location mapping technology using Wi-Fi and 3d camera of the smartphones. We applied the signal amplitude of access point using wireless lan, to develop inside location tracking system with lower price. AP is cheaper than other devices used in other tracking techniques, and by installing the software to the user's mobile device it can be directly used as the tracking system device. We used the Microsoft Kinect sensor for the 3D Camera. Kinect is equippedwith the function discriminating the depth and human information inside the shooting area. Therefore it is appropriate to extract user's body, vector, and acceleration information with low price. We confirm the location of the audience using the cell ID obtained from the Wi-Fi signal. By using smartphones as the basic device for the location service, we solve the problems of additional tagging device and provide environment that multiple users can get the interaction service simultaneously. 3d cameras located at each cell areas get the exact location and status information of the users. The 3d cameras are connected to the Camera Client, calculate the mapping information aligned to each cells, get the exact information of the users, and get the status and pattern information of the audience. The location mapping technique of Camera Client decreases the error rate that occurs on the inside location service, increases accuracy of individual discrimination in the area through the individual discrimination based on body information, and establishes the foundation of the multimodal interaction technology at the exhibition. Calculated data and information enables the users to get the appropriate interaction service through the main server.

Development of Devices for Improving the Reducibility of Patient Positioning on a Breast Board (Breast Board를 이용한 방사선치료에서 환자 위치 재현성 향상 방안에 대한 연구)

  • Huh Soon Nyung;Cho Woong;Park Yang Kyun;Ha Sung Whan
    • Radiation Oncology Journal
    • /
    • v.23 no.2
    • /
    • pp.123-130
    • /
    • 2005
  • Purpose: We wanted to improve the setup reproducibility of breast cancer patients when utilizing a commercially available breast board for radiation therapy. The breast board was modified by using a new head rest and 2 types of board fixation devices. Materials and Methods: A conventional head/neck rest was modified to be positioned in various slots of the breast board, and it was fabricated 1 cm thinner to provide more comfort to a patient when the patient's neck was rotated. This rest improves the uncertainty of the daily setup. Also, the sagging problems at the left and right sides became negligible with the two types of board fixation devices: (1) the stair type, and (2) the arm type. The first device consists of an upper/lower holder with 4 stair-types of grooves and 4 rectangular Inserts. In order to cover the whole range of vertical setup of the breast board, 4 rectangular inserts were needed, and each covered 10 steps. The arm-type fixation device was also fabricated and attached to the breast board, It had two aluminum bars that were fixed by utilizing a lock-type of screw. These devises were evaluated with two volunteers in order to prove the effectiveness of the improved setup accuracy. Results; The developed cranio-caudal fixation device demonstrated that it could reduce the cranio-caudal error by nearly $55\%$ compared to the old device. As for left-and-right inclination, the stair-type and arm-type fixation devices can reduce the relative inclination by nearly $80\%$ and $90\%$, respectively, compared to the breast board without the fixation device. Conclusion: It was verified that the developed devices were effective for positioning the patients and for avoiding inclination of the breast board.

Studies on the Simplified Hemagglutination Reaction to Pasteurella multocida and the Stabilization of Erythrocytes (Pasteurella multocida에 대(對)한 간이적혈구(簡易赤血球) 응집반응(凝集反應)과 적혈구(赤血球)의 안정화(安定化)에 관(關)한 연구(硏究))

  • Lee, Hak Cheul;Chung, Yung Gun;Kim, Kyo-Joon
    • Korean Journal of Veterinary Research
    • /
    • v.10 no.1
    • /
    • pp.11-23
    • /
    • 1970
  • Recently Carter(1952) reported the capsule antigens of Pasteurella multocida could be divided into four serological types A,B,C and D by means of precipitation tests. Subsequently he showed that the most sensitive for identification of these types involved the use of capsule substance adsorbed by erythrocytes in hemagglutination test. It may be somewhat difficult to conduct the hemagglutination test in small laboratory, because relatively large amounts of antisera and erythrocytes of the human O type are required for the test. A simple method for serological typing of P. multocida was the slide agglutination test employed by Little et al. (1943) and Namioka et al. (1962), but this method is still in controversy. The author tried adapting Carter's hemagglutination method to the slide method so called "micromethod technique", and studied on the stabilization of erythrocytes for use of slide hemagglutination to P. multocida although many invesigators reported the stabilization of erythrocytes. The results obtained are summarized as follows: 1. A simplified method (slide method) for capsule typing of the organism was developed by adapting Carter's hemagglutination reaction(tube method). Antibody-containing serum can be diluted serially on Boerner's microtest slide with capillary or serological pipetts with a considerable accuracy. The slide reaction can be carried out with case on the slide by adding $0.05m{\ell}$ of antigen-sensitized erythrocytes suspension diluted to one percent on $0.05m{\ell}$ of serially diluted antibody-containing sera, and the final result can be read after 60 minutes at the room temperature ($15^{\circ}C$). 2. It is difficult to determine superiority of inferiority between the slide method and the tube method on the pattern of the reaction of hemagglutination. 3. The pH range of 6.6 to 8.3 is optimal for the slide hemagglutination reaction. 4. The antigen-sensitization against erythrocytes at $37^{\circ}C$ is optimal for the slide hemagglutination. 5. Both the doses and concentration of antigen do not influence the antigen-adsorbing capacity of erythrocytes. 6. The reduction of antigen-sensitizing hours does not influence the antigen-adsorbing capacity of erythrocytes even 30 minutes. 7. The tannic acid treatment against formalinized and non-formalinized erythrocytes showed no effect on the reaction of hemagglutination. 8. The erythrocytes preserved at $4^{\circ}C$ in the ACD solution do not decrease the reactivity on the reaction of hemagglutination for 60 days, while they begin slight hemolysis 30 days after preserving. 9. The stable preparation of erythrocytes can be obtained by treating the cells at $37^{\circ}C$ for 20 hours with from 4 to 8 percent of formalin in saline or buffer. These cells can be preserved at $4^{\circ}C$ for more than 8 months experimented without hemolysis. With low concentration of formalin, the cells were not sufficiently stabilized resulting in the hemolysis after short period of preservation at $4^{\circ}C$. 10. The erythrocytes treated with 16 percent of formalin remain constantly or increase the reactivity for the reaction of hemagglutination. On the contrary, the cells treated with I to 8 percent of formalin decrease the reactivity. 11. There is no difference between nontreated fresh erythrocytes and the erythrocytes preserved in the ACD solution on the reactivity against the hemagglutination, and the erythrocytes treated with 16 percent of formalin showed the reactivity of higher level than that of the above two kinds of erythrocytes. 12. There is no difference between the saline and the isotonic buffer solution on the reaction of hemagglutination.

  • PDF

Determination of plasma C16-C24 globotriaosylceramide (Gb3) isoforms by tandem mass spectrometry for diagnosis of Fabry disease (패브리병(Fabry) 진단을 위한 혈장 중 Globotriaosylceramide (Gb3)의 탠덤매스 분석법 개발과 임상 응용)

  • Yoon, Hye-Ran;Cho, Kyung-Hee;Yoo, Han-Wook;Choi, Jin-Ho;Lee, Dong-Hwan;Zhang, Kate;Keutzer, Joan
    • Journal of Genetic Medicine
    • /
    • v.4 no.1
    • /
    • pp.45-52
    • /
    • 2007
  • Purpose : A simple, rapid, and highly sensitive analytical method for Gb3 in plasma was developed without labor-ex tensive pre-treatment by electrospray ionization MS/ MS (ESI-MS/MS). Measurement of globotriaosy lceramide (Gb3, ceramide trihex oside) in plasma has clinical importance for monitoring after enzyme replacement therapy in Fabry disease patients. The disease is an X-linked lipid storage disorder that results from a deficiency of the enzyme ${\alpha}$-galactosidase A (${\alpha}$-Gal A). The lack of ${\alpha}$-Gal A causes an intracellular accumulation of glycosphingolipids, mainly Gb3. Methods : Only simple 50-fold dilution of plasma is necessary for the extraction and isolation of Gb3 in plasma. Gb3 in diluted plasma was dissolved in dioxane containing C17:0 Gb3 as an internal standard. After centrifugation it was directly injected and analyzed through guard column by in combination with multiple reaction monitoring mode of ESI-MS/MS. Results : Eight isoforms of Gb3 were completely resolved from plasma matrix. C16:0 Gb3 occupied 50% of total Gb3 as a major component in plasma. Linear relationship for Gb3 isoforms w as found in the range of 0.001-1.0 ${\mu}g$/mL. The limit of detection (S/N=3) was 0.001 ${\mu}g$/mL and limit of quantification was 0.01 ${\mu}g$/mL for C16:0 Gb3 with acceptable precision and accuracy. Correlation coefficient of calibration curves for 8 Gb3 isoforms ranged from 0.9678 to 0.9982. Conclusion : This quantitative method developed could be useful for rapid and sensitive 1st line Fabry disease screening, monitoring and/or diagnostic tool for Fabry disease.

  • PDF

Characteristics of the Differences between Significant Wave Height at Ieodo Ocean Research Station and Satellite Altimeter-measured Data over a Decade (2004~2016) (이어도 해양과학기지 관측 파고와 인공위성 관측 유의파고 차이의 특성 연구 (2004~2016))

  • WOO, HYE-JIN;PARK, KYUNG-AE;BYUN, DO-SEONG;LEE, JOOYOUNG;LEE, EUNIL
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.23 no.1
    • /
    • pp.1-19
    • /
    • 2018
  • In order to compare significant wave height (SWH) data from multi-satellites (GFO, Jason-1, Envisat, Jason-2, Cryosat-2, SARAL) and SWH measurements from Ieodo Ocean Research Station (IORS), we constructed a 12 year matchup database between satellite and IORS measurements from December 2004 to May 2016. The satellite SWH showed a root mean square error (RMSE) of about 0.34 m and a positive bias of 0.17 m with respect to the IORS wave height. The satellite data and IORS wave height data did not show any specific seasonal variations or interannual variability, which confirmed the consistency of satellite data. The effect of the wind field on the difference of the SWH data between satellite and IORS was investigated. As a result, a similar result was observed in which a positive biases of about 0.17 m occurred on all satellites. In order to understand the effects of topography and the influence of the construction structures of IORS on the SWH differences, we investigated the directional dependency of differences of wave height, however, no statistically significant characteristics of the differences were revealed. As a result of analyzing the characteristics of the error as a function of the distance between the satellite and the IORS, the biases are almost constant about 0.14 m regardless of the distance. By contrast, the amplitude of the SWH differences, the maximum value minus the minimum value at a given distance range, was found to increase linearly as the distance was increased. On the other hand, as a result of the accuracy evaluation of the satellite SWH from the Donghae marine meteorological buoy of Korea Meteorological Administration, the satellite SWH presented a relatively small RMSE of about 0.27 m and no specific characteristics of bias such as the validation results at IORS. In this paper, we propose a conversion formula to correct the significant wave data of IORS with the satellite SWH data. In addition, this study emphasizes that the reliability of data should be prioritized to be extensively utilized and presents specific methods and strategies in order to upgrade the IORS as an international world-wide marine observation site.