A Study on Calibration Procedures for Ir-192 High Dose Rate Brachytherapy Sources (고선량률(HDR) 근접치료의 동위원소 Ir-192에 대한 측정방법에 관한 고찰)

  • Baek, Tae-Seong;Lee, Seung-Wook;Na, Soo-Kyong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.1
    • /
    • pp.19-26
    • /
    • 2007
  • Purpose: To compare of the accuracy among various measurement procedures of HDR Brachytherapy, and to evaluate the clinical suitability and usefulness of alternative PMMA (polymethylmethacrylateplastics: $C_5H_8O_2$) plate phantom without any additional cost due to the purchase of measuring apparatus. Materials and Methods: We made a comparative study on three types of measuring systems: well type chamber, source calibration jig, and PMMA plate phantom. Farmer type chamber was used for source calibration jig method and PMMA plate phantom method. Measurement was done 5 times each in comparison with the measurement values from manufacturer. Measurement results from experiment were compared with that from the manufacturer which is offered with the source whenever a source is substituted by a new one and evaluate the accuracy of source activity. Results: As a consequence of Ir-192 source measurement using well type chamber, source calibration jig and PMMA plate phantom, RMS (Root Mean Square) values for the relative error are 0.6%, 1.57%, 2.1%, respectively, compared with the data from manufacturer. And the mean errors with standard deviation are given $-0.2{\pm}0.5%$, $0.97{\pm}1.23%$, $-0.89{\pm}1.87%$ respectively. Conclusion: From the results shown by the three types of measurement system (well type chamber, source calibration jig, and PMMA plate phantom), the measurement with well type chamber produced the best accuracy. It turns out that we can also use the alternative system of PMMA plate phantom clinically without purchasing any additional particular apparatus since the system does not exceed the recommendation of AAPM (American Association of Physicists in Medicine), which requires the error range of within ${\pm}5%$.

  • PDF

Accuracy and Clinical Outcomes of Ultrasound-guided Glenohumeral joint Injection: Acromioclavicular Approach in Patients with Adhesive Capsulitis (초음파를 이용한 견관절 관절강내 주사의 정확성과 임상적 결과: 유착성 관절낭염 환자의 견봉 쇄골 접근법)

  • Lhee, Sang-Hoon;Hwang, Seok-Min
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.5 no.1
    • /
    • pp.9-14
    • /
    • 2012
  • Purpose: The purpose of the study was to evaluate the accuracy and clinical outcome of ultrasound-guided glenohumeral joint steroid injection on adhesive capsulitis. Materials and Methods: Patients who were diagnosed as adhesive capsulitis by MRI and physical examination and did not improve their symptom with physical therapy and NSAIDS treatment more than 6 months were included in the study. Patients who showed any other shoulder pathology or history if trauma were excluded from the study. 33 patients including 15 males and 18 females were enrolled in the study, the average age being 55.1 (age 42~72). Cocktail of steroid, lidocaine, saline and contrast medium injected inside shoulder glenohumeral joint using novel approach (which we called acromioclavicular approach) under ultrasound guidance. Clinical outcome was measured through passive range of motion and VAS scoring system. Results: Based on radiographic findings, cases were classified according to the leakage of contrast medium; perfect confinement of contrast-medium inside the capsule, partial leakage of the medium and contrast-medium found at outside the joint. Total 25 cases (76%) out of 33 cases showed perfect confinement of contrast-medium inside the glenohumeral joint. Partial leakage was observed in 6 cases (18%), and contrast medium was observed outside of the glenohumeral joint in 2 cases (6%). Perfect-confinement group showed $111^{\circ}$($80{\sim}140^{\circ}$) of forward flexion and $48^{\circ}$($0{\sim}90^{\circ}$) of external rotation before injection, and improved to $134^{\circ}$($90{\sim}150^{\circ}$) of forward flexion and $70^{\circ}$($30{\sim}90^{\circ}$) of external rotation after injection (p<0.01). Partial leakage showed $120^{\circ}$($90{\sim}150^{\circ}$) of forward flexion and $70^{\circ}$($10{\sim}90^{\circ}$) of external rotation before injection, and improved to $139^{\circ}$($135{\sim}140^{\circ}$) of forward flexion and $78^{\circ}$($50{\sim}90^{\circ}$) of external rotation after injection (p<0.01). VAS score improved from 7.1 (score 3~9) to 2.6 (score 0~5) (p<0.01) in perfect confinement group, from 7.5 (score 7~9) to 3.3 (score 2~4) (p<0.01) in partial leakage group. Two group showed no significant difference. Conclusion: Accuracy of Acromioclavicular approach was 94% which is better than any other methods published so far. Partial leakage of the injection material did not show inferior result compared to perfect injection.

  • PDF

Diagnostic Accuracy of 2-mm Minithoracoscopic Pleural Biopsy for Pleural Effusion (흉수 환자에서 Minithoracoscopy를 이용한 흉막 생검의 진단적 유용성)

  • Kim, Woo Jin;Lee, Hui Young;Lee, Sung Ho;Cho, Seong Joon;Park, Weon-Seo;Kim, Ja Kyoung;Lee, Seung-Joon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.57 no.2
    • /
    • pp.138-142
    • /
    • 2004
  • Background : To evaluate exudative pleural fluid, thoracentesis for microbiological and cytological examination and pleural biopsy by using a Cope needle are traditionally performed. Even after these studies, about 20% of patients remain undiagnosed. We evaluated the diagnostic accuracy and complications of 2-mm minithoracoscopy instead of blind biopsy in patients with undiagnosed exudative pleural effusion. Method : Fifteen patients with exudative pleural effusion underwent thoracoscopy between April 2002 and August 2003. The indication was undiagnosed pleural effusions after having performed sputum and pleural fluid exami-nations both microbiologically and cytologically. Results : The median age of the patients was 56 years (range 21-77). Pleural effusions were lymphocyte-dominant in 11 patients (73.3%) and neutrophil-dominant in 3 (20.0%). The remaining patient (6.7%) had pleural-fluid eosinophilia. Minithoracoscopic biopsy revealed accurate diagnosis in 14 patients (93.3%), consisting of tuberculous pleurisy in 8 (66.7%), malignant effusions in 4 (33.3%), and parapneumonic effusions in 2 (13.3%). One was diagnosed as having paragonimiasis from thoracoscopic findings and clinical considerations. There was no procedure-associated mortality. There were six cases of new onset fever (40%) and one of pneumothorax (6.7 %). Conclusion : Two-millimeter minithoracoscopy, which is less invasive than conventional thoracoscopy, was an accurate and safe method for undiagnosed exudative pleural effusion.

Accurate Quality Control Method of Bone Mineral Density Measurement -Focus on Dual Energy X-ray Absorptiometry- (골밀도 측정의 정확한 정도관리방법 -이중 에너지 방사선 흡수법을 중심으로-)

  • Kim, Ho-Sung;Dong, Kyung-Rae;Ryu, Young-Hwan
    • Journal of radiological science and technology
    • /
    • v.32 no.4
    • /
    • pp.361-370
    • /
    • 2009
  • The image quality management of bone mineral density is the responsibility and duty of radiologists who carry out examinations. However, inaccurate conclusions due to lack of understanding and ignorance regarding the methodology of image quality management can be a fatal error to the patient. Therefore, objective of this paper is to understand proper image quality management and enumerate methods for examiners and patients, thereby ensuring the reliability of bone mineral density exams. The accuracy and precision of bone mineral density measurements must be at the highest level so that actual biological changes can be detected with even slight changes in bone mineral density. Accuracy and precision should be continuously preserved for image quality of machines. Those factors will contribute to ensure the reliability in bone mineral density exams. Proper equipment management or control methods are set with correcting equipment each morning and after image quality management, a phantom, recommended from the manufacturer, is used for ten to twenty-five measurements in search of a mean value with a permissible range of ${\pm}1.5%$ set as standard. There needs to be daily measurement inspections on the phantom or at least inspections three times a week in order to confirm the existence or nonexistence of changes in values in actual bone mineral density. in addition, bone mineral density measurements were evaluated and recorded following the rules of Shewhart control chart. This type of management has to be conducted for the installation and movement of equipment. For the management methods of inspectors, evaluation of the measurement precision was conducted by testing the reproducibility of the exact same figures without any real biological changes occurring during reinspection. Bone mineral density inspection was applied as the measurement method for patients either taking two measurements thirty times or three measurements fifteen times. An important point when taking measurements was after a measurement whether it was the second or third examination, it was required to descend from the table and then reascend. With a 95% confidence level, the precision error produced from the measurement bone mineral figures came to 2.77 times the minimum of the biological bone mineral density change. The value produced can be stated as the least significant change (LSC) and in the case the value is greater, it can be stated as a section of genuine biological change. From the initial inspection to equipment moving and shifter, management must be carried out and continued in order to achieve the effects. The enforcement of proper quality control of radiologists performing bone mineral density inspections which brings about the durability extensions of equipment and accurate results of calculations will help the assurance of reliable inspections.

  • PDF

Corporate Bond Rating Using Various Multiclass Support Vector Machines (다양한 다분류 SVM을 적용한 기업채권평가)

  • Ahn, Hyun-Chul;Kim, Kyoung-Jae
    • Asia pacific journal of information systems
    • /
    • v.19 no.2
    • /
    • pp.157-178
    • /
    • 2009
  • Corporate credit rating is a very important factor in the market for corporate debt. Information concerning corporate operations is often disseminated to market participants through the changes in credit ratings that are published by professional rating agencies, such as Standard and Poor's (S&P) and Moody's Investor Service. Since these agencies generally require a large fee for the service, and the periodically provided ratings sometimes do not reflect the default risk of the company at the time, it may be advantageous for bond-market participants to be able to classify credit ratings before the agencies actually publish them. As a result, it is very important for companies (especially, financial companies) to develop a proper model of credit rating. From a technical perspective, the credit rating constitutes a typical, multiclass, classification problem because rating agencies generally have ten or more categories of ratings. For example, S&P's ratings range from AAA for the highest-quality bonds to D for the lowest-quality bonds. The professional rating agencies emphasize the importance of analysts' subjective judgments in the determination of credit ratings. However, in practice, a mathematical model that uses the financial variables of companies plays an important role in determining credit ratings, since it is convenient to apply and cost efficient. These financial variables include the ratios that represent a company's leverage status, liquidity status, and profitability status. Several statistical and artificial intelligence (AI) techniques have been applied as tools for predicting credit ratings. Among them, artificial neural networks are most prevalent in the area of finance because of their broad applicability to many business problems and their preeminent ability to adapt. However, artificial neural networks also have many defects, including the difficulty in determining the values of the control parameters and the number of processing elements in the layer as well as the risk of over-fitting. Of late, because of their robustness and high accuracy, support vector machines (SVMs) have become popular as a solution for problems with generating accurate prediction. An SVM's solution may be globally optimal because SVMs seek to minimize structural risk. On the other hand, artificial neural network models may tend to find locally optimal solutions because they seek to minimize empirical risk. In addition, no parameters need to be tuned in SVMs, barring the upper bound for non-separable cases in linear SVMs. Since SVMs were originally devised for binary classification, however they are not intrinsically geared for multiclass classifications as in credit ratings. Thus, researchers have tried to extend the original SVM to multiclass classification. Hitherto, a variety of techniques to extend standard SVMs to multiclass SVMs (MSVMs) has been proposed in the literature Only a few types of MSVM are, however, tested using prior studies that apply MSVMs to credit ratings studies. In this study, we examined six different techniques of MSVMs: (1) One-Against-One, (2) One-Against-AIL (3) DAGSVM, (4) ECOC, (5) Method of Weston and Watkins, and (6) Method of Crammer and Singer. In addition, we examined the prediction accuracy of some modified version of conventional MSVM techniques. To find the most appropriate technique of MSVMs for corporate bond rating, we applied all the techniques of MSVMs to a real-world case of credit rating in Korea. The best application is in corporate bond rating, which is the most frequently studied area of credit rating for specific debt issues or other financial obligations. For our study the research data were collected from National Information and Credit Evaluation, Inc., a major bond-rating company in Korea. The data set is comprised of the bond-ratings for the year 2002 and various financial variables for 1,295 companies from the manufacturing industry in Korea. We compared the results of these techniques with one another, and with those of traditional methods for credit ratings, such as multiple discriminant analysis (MDA), multinomial logistic regression (MLOGIT), and artificial neural networks (ANNs). As a result, we found that DAGSVM with an ordered list was the best approach for the prediction of bond rating. In addition, we found that the modified version of ECOC approach can yield higher prediction accuracy for the cases showing clear patterns.

The Comparison between Single Shot Turbo Spin Echo and B-FFE (Balanced Turbo Field-echo) in the Differentiation of Focal Liver Lesions (국소 간병변 감별에서 단발고속스핀에코 기법과 균형항정상 태세차를 이용한 고속영역 기법간의 비교)

  • Kim, Young-Chul;Kim, Myeong-Jin;Cha, Seung-Whan;Chung, Yong-Eun;Han, Kwang-Hyup;Choi, Jin-Sub
    • Investigative Magnetic Resonance Imaging
    • /
    • v.11 no.1
    • /
    • pp.39-48
    • /
    • 2007
  • Purpose : To determine the diagnostic accuracy of four different sequences : moderately T2 weighted, two heavily T2-weighted single shot turbo spin-echo sequence and breath-hold axial-2D balanced turbo field-echo sequence(bFFE) for characterization of focal lesions. Materials and Methods : During the 3-month period between June and August 2005, seventy-six patients were proved to have ninety-three focal hepatic lesions on MR imaging. The patients consisted of 49 men and 27 women (age range, 15-75 years; mean age, 56.23 years). All MR images were acquired on a 1.5-T MR using the following sequences: 1. A breath-hold axial T2-weighted single shot turbo spin-echo sequence, 2. a breath-hold axial-2D balanced turbo field-echo sequence. Two radiologists performed quantitative analysis. Another radiologist measured the lesion-to-liver contrast-to-noise ratio at the region-of-interest in the four sequences. Results : There was no significant difference in inter-observer variability between the four sequences. The accuracy for both cyst and malignancy of moderate T2 weighted MRI (echo time: 80 msec) was also highest. There was significant difference for lesion characterization between moderate T2 weighted MRI and balanced steady state procession (p-value: 0.004) in the second reader. For longer echo time, the CNR of cystic lesions were markedly increased in comparison to lesions of other component. Conclusion : The accuracy and inter-observer variability of single shot turbo spin echo T2 weighted sequence was higher than bFFE. Although there was no statically significant difference, moderate T2 weighted MRI (echo time: 80 msec) was more accurate than heavily T2 weighted sequence (echo time: 300 msec). If the results for lesion characterization is equivocal in TE 80, the addition of heavily T2 weighted MRI (echo time: 180 msec) can be helpful.

  • PDF

A Study on the Establishment of Acceptable Range for Internal Quality Control of Radioimmunoassay (핵의학 검체검사 내부정도관리 허용범위 설정에 관한 고찰)

  • Young Ji, LEE;So Young, LEE;Sun Ho, LEE
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.26 no.2
    • /
    • pp.43-47
    • /
    • 2022
  • Purpose Radioimmunoassay implement quality control by systematizing the internal quality control system for quality assurance of test results. This study aims to contribute to the quality assurance of radioimmunoassay results and to implement systematic quality control by measuring the average CV of internal quality control and external quality control by plenty of institutions for reference when setting the laboratory's own acceptable range. Materials and Methods We measured the average CV of internal quality control and the bounce rate of more than 10.0% for a total of 42 items from October 2020 to December 2021. According to the CV result, we classified and compared the upper group (5.0% or less), the middle group (5.0~10.0%) and the lower group (10.0% or more). The bounce rate of 10.0% or more was compared by classifying the item of five or more institutions into tumor markers, thyroid hormones and other hormones. The average CV was measured by the overall average and standard deviation of the external quality control results for 28 items from the first quarter to the fourth quarter of 2021. In addition, the average CV was measured by the overall average and standard deviation of the proficiency results between institutions for 13 items in the first half and the second half of 2021. The average CV of internal quality control and external quality control was compared by item so we compared and analyzed the items that implement well to quality control and the items that require attention to quality control. Results As a result of measuring the precision average of internal quality control for 42 items of six institutions, the top group (5.0% or less) are Ferritin, HGH, SHBG, and 25-OH-VitD, while the bottom group (≤10.0%) are cortisol, ATA, AMA, renin, and estradiol. When comparing more than 10.0% bounce rate of CV for tumor markers, CA-125 (6.7%), CA-19-9 (9.8%) implemented well, while SCC-Ag (24.3%), CA-15-3 (26.7%) were among the items that require attention to control. As a result of comparing the bounce rate of more than 10.0% of CV for thyroid hormones examination, free T4 (2.1%), T3 (9.3%) showed excellent performance and AMA (39.6%), ATA (51.6%) required attention to control. When comparing the bounce rate of 10.0% or more of CV for other hormones, IGF-1 (8.8%), FSH (9.1%), prolactin (9.2%) showed excellent performance, however estradiol (37.3%), testosterone (37.7%), cortisol (44.4%) required attention to control. As a result of measuring the average CV of the whole institutions participating at external quality control for 28 items, HGH and SCC-Ag were included in the top group (≤10.0%), however ATA, estradiol, TSI, and thyroglobulin included in bottom group (≥30.0%). Conclusion As a result of evaluating 42 items of six institutions, the average CV was 3.7~12.2% showing a 3.3 times difference between the upper group and the lower group. Cortisol, ATA, AMA, Renin and estradiol tests with high CV will require continuous improvement activities to improve precision. In addition, we measured and compared the overall average CV of the internal quality control, the external quality control and the proficiency between institutions participating of six institutions for 41 items excluding HBs-Ab. As a result, ATA, AMA, Renin and estradiol belong to the same subgroup so we require attention to control and consider setting a higher acceptable range. It is recommended to set and control the acceptable range standard of internal quality control CV in consideration of many things in the laboratory due to the different reagents and instruments, and the results vary depending on the test's proficiency and quality control materials. It is thought that the accuracy and reliability of radioimmunoassay results can be improved if systematic quality control is implemented based on the set acceptable range.

Stand Growth Estimation Using Nonlinear Growth Equations (비선형(非線型) 생장함수(生長函數)를 이용(利用)한 임분생장(林分生長) 추정(推定))

  • Son, Yeong Mo;Lee, Kyeong Hak;Chung, Young Gyo
    • Journal of Korean Society of Forest Science
    • /
    • v.86 no.2
    • /
    • pp.135-145
    • /
    • 1997
  • This study aimed at evaluating one curvilinear equation and nine non-linear equations for estimating stand growth characteristics(mean dbh, mean height and volume per ha) for the plantations of Pinus koraiensis and the natural stands of Quercus mongolica. The data were collected from 92 plots in Pines koraiensis stands and 83 plots in Quercus mongolica stands, and the site index of all the stands is 14. The curvilinear equation, $Y=at^be^{-c/t}$, used in preparing the yield tables was well fitted within the range of data, but was likely to give overestimates when extrapolating in old stage due to the tendency of linear increase. Among the non-linear equations, logistic equation and Sloboda equation gave overestimates in young stands and reached the asymptotic status early which means underestimates in old stage. Extrapolating in old stage, Hossfeld equation generally gave larger values than others due to its large estimates of parameter a, the maximum value. On the other hand, Bertalanffy equation gave underestimates in young and old stands and overestimates in middle-aged stands. The estimates with Korf equation was relatively low for Pinus koraiensis stands, and this tendency was more obvious in dbh growth of Quercus mongolica stands. Ueno-Ohzaki equation was liable to give over or underestimates depending on the value of parameter b when extrapolating in old stands. Considering the accuracy of estimates and the biological base of the growth equations, Gompertz equation, Chapman-Richards equation and Weibull equation were generally applicable for estimating the stand growth characteristics of both species in the whole range of stand ages including extrapolated range. To get more accurate and precise parameter estimates, more data, especially in old stands, should be required in further study.

  • PDF

A Study For Optimizing Input Waveforms In Radiofrequency Liver Tumor Ablation Using Finite Element Analysis (유한 요소 해석을 이용한 고주파 간 종양 절제술의 입력 파형 최적화를 위한 연구)

  • Lim, Do-Hyung;NamGung, Bum-Seok;Lee, Tae-Woo;Choi, Jin-Seung;Tack, Gye-Rae;Kim, Han-Sung
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.2
    • /
    • pp.235-243
    • /
    • 2007
  • Hepatocellular carcinoma is significant worldwide public health problem with an estimated annually mortality of 1,000,000 people. Radiofrequency (RF) ablation is an interventional technique that in recent years has come to be used for treatment of the hepatocellualr carcinoma, by destructing tumor tissues in high temperatures. Numerous studies have been attempted to prove excellence of RF ablation and to improve its efficiency by various methods. However, the attempts are sometimes paradox to advantages of a minimum invasive characteristic and an operative simplicity in RF ablation. The aim of the current study is, therefore, to suggest an improved RF ablation technique by identifying an optimum RF pattern, which is one of important factors capable of controlling the extent of high temperature region in lossless of the advantages of RF ablation. Three-dimensional finite element (FE) model was developed and validated comparing with the results reported by literature. Four representative Rf patterns (sine, square, exponential, and simulated RF waves), which were corresponding to currents fed during simulated RF ablation, were investigated. Following parameters for each RF pattern were analyzed to identify which is the most optimum in eliminating effectively tumor tissues. 1) maximum temperature, 2) a degree of alteration of maximum temperature in a constant time range (30-40 second), 3) a domain of temperature over $47^{\circ}C$ isothermal temperature (IT), and 4) a domain inducing over 63% cell damage. Here, heat transfer characteristics within the tissues were determined by Bioheat Governing Equation. Developed FE model showed 90-95% accuracy approximately in prediction of maximum temperature and domain of interests achieved during RF ablation. Maximum temperatures for sine, square, exponential, and simulated RF waves were $69.0^{\circ}C,\;66.9^{\circ}C,\;65.4^{\circ}C,\;and\;51.8^{\circ}C$, respectively. While the maximum temperatures were decreased in the constant time range, average time intervals for sine, square, exponential, and simulated RE waves were $0.49{\pm}0.14,\;1.00{\pm}0.00,\;1.65{\pm}0.02,\;and\;1.66{\pm}0.02$ seconds, respectively. Average magnitudes of the decreased maximum temperatures in the time range were $0.45{\pm}0.15^{\circ}C$ for sine wave, $1.93{\pm}0.02^{\circ}C$ for square wave, $2.94{\pm}0.05^{\circ}C$ for exponential wave, and $1.53{\pm}0.06^{\circ}C$ for simulated RF wave. Volumes of temperature domain over $47^{\circ}C$ IT for sine, square, exponential, and simulated RF waves were 1480mm3, 1440mm3, 1380mm3, and 395mm3, respectively. Volumes inducing over 63% cell damage for sine, square, exponential, and simulated RF waves were 114mm3, 62mm3, 17mm3, and 0mm3, respectively. These results support that applying sine wave during RF ablation may be generally the most optimum in destructing effectively tumor tissues, compared with other RF patterns.

Habitat Distribution Change Prediction of Asiatic Black Bears (Ursus thibetanus) Using Maxent Modeling Approach (Maxent 모델을 이용한 반달가슴곰의 서식지 분포변화 예측)

  • Kim, Tae-Geun;Yang, DooHa;Cho, YoungHo;Song, Kyo-Hong;Oh, Jang-Geun
    • Korean Journal of Ecology and Environment
    • /
    • v.49 no.3
    • /
    • pp.197-207
    • /
    • 2016
  • This study aims at providing basic data to objectively evaluate the areas suitable for reintroduction of the species of Asiatic black bear (Ursus thibetanus) in order to effectively preserve the Asiatic black bears in the Korean protection areas including national parks, and for the species restoration success. To this end, this study predicted the potential habitats in East Asia, Southeast Asia and India, where there are the records of Asiatic black bears' appearances using the Maxent model and environmental variables related with climate, topography, road and land use. In addition, this study evaluated the effects of the relevant climate and environmental variables. This study also analyzed inhabitation range area suitable for Asiatic black and geographic change according to future climate change. As for the judgment accuracy of the Maxent model widely utilized for habitat distribution research of wildlife for preservation, AUC value was calculated as 0.893 (sd=0.121). This was useful in predicting Asiatic black bears' potential habitat and evaluate the habitat change characteristics according to future climate change. Compare to the distribution map of Asiatic black bears evaluated by IUCN, Habitat suitability by the Maxent model were regionally diverse in extant areas and low in the extinct areas from IUCN map. This can be the result reflecting the regional difference in the environmental conditions where Asiatic black bears inhabit. As for the environment affecting the potential habitat distribution of Asiatic black bears, inhabitation rate was the highest, according to land coverage type, compared to climate, topography and artificial factors like distance from road. Especially, the area of deciduous broadleaf forest was predicted to be preferred, in comparison with other land coverage types. Annual mean precipitation and the precipitation during the driest period were projected to affect more than temperature's annual range, and the inhabitation possibility was higher, as distance was farther from road. The reason is that Asiatic black bears are conjectured to prefer more stable area without human's intervention, as well as prey resource. The inhabitation range was predicted to be expanded gradually to the southern part of India, China's southeast coast and adjacent inland area, and Vietnam, Laos and Malaysia in the eastern coastal areas of Southeast Asia. The following areas are forecast to be the core areas, where Asiatic black bears can inhabit in the Asian region: Jeonnam, Jeonbuk and Gangwon areas in South Korea, Kyushu, Chugoku, Shikoku, Chubu, Kanto and Tohoku's border area in Japan, and Jiangxi, Zhejiang and Fujian border area in China. This study is expected to be used as basic data for the preservation and efficient management of Asiatic black bear's habitat, artificially introduced individual bear's release area selection, and the management of collision zones with humans.