• Title/Summary/Keyword: Ramp-up

Search Result 102, Processing Time 0.022 seconds

1D AND 3D ANALYSES OF THE ZY2 SCIP BWR RAMP TESTS WITH THE FUEL CODES METEOR AND ALCYONE

  • Sercombe, J.;Agard, M.;Struzik, C.;Michel, B.;Thouvenin, G.;Poussard, C.;Kallstrom, K.R.
    • Nuclear Engineering and Technology
    • /
    • v.41 no.2
    • /
    • pp.187-198
    • /
    • 2009
  • In this paper, three power ramp tests performed on high burn-up Re-crystallized Zircaloy2 - UO2 BWR fuel rods (56 to 63 MWd/kgU) within the SCIP project are simulated with METEOR and ALCYONE 3D. Two of the ramp tests are of staircase type up to Linear Heat Rates of 420 and 520 W/cm and with long holding periods. Failure of the 420 W/cm fuel rod was observed after 40 minutes. The third ramp test consisted of a more standard ramp test with a constant power rate of 80 W/cm/min up to 410 W/cm with a short holding time. The tests were first simulated with the METEOR 1D fuel rod code, which gave accurate results in terms of profilometry and fission gas releases. The behaviour of a fuel pellet fragment and of the cladding piece on top of it was then investigated with ALCYONE 3D. The size and the main characteristics of the ridges after base irradiation and power ramp testing were recovered. Finally, the failure criteria validated for PWR conditions and fuel rods with low-to-medium burn-ups were used to analyze the failure probability of the KKL rodlets during ramp testing.

Effects of the Gait Variable While Using Smartphones During Ramp Gait in Young Adults (젊은 성인에서 경사로 보행 시 스마트폰 사용이 보행 변수에 미치는 영향)

  • Yoon, Chae-Hyo;Kim, Bum-Su;Kang, Do-Young;Kim, Yeonseo;Lee, Myoung-Hee
    • PNF and Movement
    • /
    • v.19 no.2
    • /
    • pp.261-267
    • /
    • 2021
  • Purpose: This study aimed to investigate changes in gait variables depending on whether a task was performed using a smartphone while walking on a ramp. Methods: The participants of this study were 41 college students attending U University located in Gyeongju City, Gyeongsangbuk-do. In this study, gait variables were measured during ramp gait while using a smartphone to perform a task and during ramp gait without performing such tasks. In other words, four walking conditions were used: 1) walking up a ramp, 2) walking up a ramp while using a smartphone to perform a task, 3) walking down a ramp, and 4) walking down a ramp while using a smart phone to perform a task. Gait variables were measured using a gait analysis tool (Legsys; BioSensics, USA), and stride time, stride length, stride velocity, cadence, and double support were analyzed. The order of measurements was randomized to control for order effects due to repeated measurements. Results: The comparative analysis of gait variables according to the presence or absence of smartphone use during ramp gait showed that there were significant differences in stride time, stride length, and stride velocity during both ramp ascent and ramp descent (p < 0.05). In both ramp ascent and ramp descent, stride time increased when walking using a smartphone, compared to when walking without using a smartphone (p < 0.05). However, in both ramp ascent and ramp descent, stride length and stride velocity were decreased when walking using a smartphone compared to when walking without using a smartphone (p < 0.05). Conclusion: The study results showed that the use of a smartphone during walking can affect safety. Therefore, it is necessary to improve the awareness of risks associated with walking while using a smartphone, and further research needs to be conducted in various environments and with different ramps.

A Study on Discharge Characteristics of the PDP Packaged with In-situ Vacuum Sealing with the MgO Protective Layer Deposited by Optimal Evaporation Rate (최적 증착 속도로 형성된 MgO를 갖는 인-라인 진공 실장된 플라즈마 디스플레이 패널의 방전 특성에 관한 연구)

  • Li, Zhao-Hui;Cho, Eou-Sik;Kwon, Sang-Jik
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.10
    • /
    • pp.916-922
    • /
    • 2008
  • AC PDP with MgO protective layer coated with the optimum evaporation rate of $5{\AA}/s$ can generate more enhanced efficiency through the vacuum in-line sealing process. However, the optimized process conditions still require the optimum driving scheme on the ramp-up and ramp-down slope of the reset waveform for enhancing the efficiency. In this paper, for the in-situ vacuum sealed PDP with the optimum evaporation rate of MgO protective layer, the address delay time was investigated with various slopes of ramp waveform during a reset ramp-up and ramp-down period. In this study, the minimum statistical delay time was obtained at the ramp-up rate of $6.0 V/{\mu}s$ and the ramp-down rate of $0.7 V/{\mu}s$ of the reset waveform.

A new ramp reset waveform for reducing reset period using address pulse of AC-PDP

  • Kim, Gun-Su;Choi, Hoon-Young;Lee, Seok-Hyun;Kim, Jun-Hyoung;Mim, Byoung-Kuk
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.609-612
    • /
    • 2002
  • A new reset waveform is proposed for reducing the reset period. A square pulse is applied to the address electrode while reset pulse ramps and before a discharge between the sustain electrodes occurs. The square pulse induces a discharge between the address electrode and the X electrode, and the induced wall charge is opposite to the applied ramp pulse. Thus, the next discharge between the sustain electrodes becomes weaker. The weaker discharge lowers background luminance and improves contrast ratio. Thus, the new reset waveform can reduce ramp up time in the ramp reset waveform The experimental results show that the ramp up time can be reduced by about 90% compared with the conventional ramp reset waveform.

  • PDF

Practical Review of Analysis Techniques for Patronage Ramp-up (Ramp-up 분석기법에 대한 실증적 고찰)

  • Chung, Sung-Bong;Chang, Justin Su-Eun;Kim, Ki-Min;Kim, Jeong-Hyun
    • Journal of Korean Society of Transportation
    • /
    • v.26 no.5
    • /
    • pp.17-28
    • /
    • 2008
  • This study examines the ramp-up analysis techniques which have been introduced till now and presents the strength and weakness of each method. The applicability of each technique was reviewed using a case study involving the data of Cheonan-Nonsan motorway usages where seasonal variations of the data were removed. The results showed that all the techniques except F-test have the same ramp-up period of 12 months. The level of Tamp-up was 65%-72% compared to that of the real traffic volume at the beginning of opening. The demand recovered to the stabilized level as time goes on. To apply the methodology to practical demand forecasts actual surveys of real data of traffic demand should be performed. With these efforts to the patronage ramp-up, more reliable demand analyses can be accompanied.

The Effects of Ramp Gradients and Pushing-Pulling Techniques on Lumbar Spinal Load in Healthy Workers

  • Pinupong, Chalearmpong;Jalayondeja, Wattana;Mekhora, Keerin;Bhuanantanondh, Petcharatana;Jalayondeja, Chutima
    • Safety and Health at Work
    • /
    • v.11 no.3
    • /
    • pp.307-313
    • /
    • 2020
  • Background: Many tasks in industrial and health care setting are involved with pushing and pulling tasks up or down on a ramp. An efficient method of moving cart which reduces the risk of low back pain should be concerned. This study aimed to investigate the effects of handling types (HTs) and slope on lumbar spinal load during moving a cart on a ramp. We conducted a 2 × 2 × 4 factorial design with three main factors: 2 HTs, 2 handling directions of moving a cart and 4 degrees of ramp slope. Methods: Thirty healthy male workers performed 14 tasks consist of moving a cart up and down on the ramp of 0°, 10°, 15°, and 20° degrees with pushing and pulling methods. Joint angles from a 3D motion capture system combined with subject height, body weight, and hand forces were used to calculate the spinal load by the 3DSSPP program. Results: Our results showed significant effect of HT, handling directions and slope on compression and shear force of the lumbar spine (p < 0.001). When the ramp gradient increased, the L4/5 compression forces increased in both pushing and pulling (p < 0.001) Shear forces increased in pulling and decreased in pushing in all tasks. At high slopes, pulling generated more compression and shear forces than that of pushing (p < 0.01). Conclusion: Using the appropriate technique of moving a cart on the ramp can reduce the risk of high spinal load, and the pushing is therefore recommended for moving a cart up/down on ramp gradients.

Effects of Ramp Type-Common Electrode Bias on Reset Discharge Characteristics in AC-PDP

  • Park, Choon-Sang;Cho, Byung-Gwon;Tae, Heung-Sik
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.1258-1261
    • /
    • 2005
  • The ramp type bias voltage applied to the common electrode during a reset-period is newly proposed to lower the background luminance and to improve the address discharge characteristics in AC-PDP. The positive ramp bias voltage is applied during the ramp-up period, whereas the negative ramp bias voltage is applied during the ramp-down period. The effects of the voltage slopes in both the positive and negative ramp bias voltages on the background luminance and address voltage characteristics are examined intensively. It is observed that the optimized positive and negative ramp bias voltages applied to the common electrode during the ramp-period can lower the background luminance and also enhance the address discharge characteristics of the AC-PDP.

  • PDF

Walkability on Ramps by Gait Analysis (보행자세해석에 의한 경사로의 보행성)

  • 유남형
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.23 no.2
    • /
    • pp.157-166
    • /
    • 1995
  • To investigate walkability of ramps, walking patterns of 18 healthy adults,12 aged 20 to 26 and 6 aged 68 to 76,were studied at free,rhythm constrained walking up or down ramp using goniometer and footswitch Ramp inclinations were set 4,8,12,16,20 degrees. The results were as follows. 1)The step length of subjects were decreased significantly in12$^{\circ}C$′or 16′free downramp walking. With regard to step length, some subject groups walked abnormally in 16" or 20" ramp walking 2) The step width of subjects were increased significantly in 12" or 16" ramp walking. 3) The cadence duration of some subject groups were increased in 12" upramp walking. 4) The double stance duration and double stance ratio of some subject groups were increased significantly in 8",12", or 16"upramp walking. 5) The maximum knee flexion angle of stance phase were increased in 12" ramp walking. 6)Most temporal parameters and spatial parameters of gait were increased or decreassd greatly between 4" ramp and 8" ramp or between 8′ramp and 12′ramp. But statistics significancy were not recognized 7) The results suggest that ramp inclination less than 8′(14%) -12′(21%) is desirable for the normal gait the ramp inclination must not exceed 16" -20" in unavoidable circumstances.

  • PDF

A New Improved Reset Waveform for High Dark Room Contrast Ratio and Reduction of the Reset Time in ACPDPs (높은 암실 명암비와 초기화 시간 단축을 위한 새로운 초기화 파형)

  • Lee, In-Moo;Kim, Joon-Yub
    • Proceedings of the KIEE Conference
    • /
    • 2005.11a
    • /
    • pp.109-112
    • /
    • 2005
  • 본 논문에서는 초기화 구간에서의 시간단축과 높은 암실 명암비를 얻을 수 있는 새로운 초기화 파형을 제시한다. 새로운 초기화 파형에서 첫 번째 subfield는 기존의 conventional 구동파형과 마찬가지로 초기화 구간에서 ramp-up구간과 ramp-down구간이 필요하지만, 두 번째 subfield부터는 단지 ramp-up구간만이 적용된다. 한 frame에 8개의 subfield를 적용할 경우, 기존의 구동파형의 배경광이 $0.40cd/m^2$로 측정되는 반면, 새로운 초기화파형을 패널에 적용할 경우 배경광이 측정되지 않는다. 이러하여 우리는 새로운 초기화파형에서 무한대의 암실 명암비를 얻을 수 있다. 또한 새로운 초기화파형에서는 ramp-down구간을 없앰으로써 첫 번째 subfield를 제외하고는 초기화 시간을 165us로 시간을 줄일 수 있다.

  • PDF