• Title/Summary/Keyword: Ramp current

Search Result 129, Processing Time 0.029 seconds

Deterioration Test of IGBT Devices in Motor Driver (전동기 구동용 IGBT 소자의 열화 진단)

  • Ahn, Jong-Kon;Park, Soon-Myung;Kim, Tae-Gi;Kang, Ju-Hee
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.400-405
    • /
    • 2008
  • Motor is energy converting system to generate mechanical force from electrical power and there are various typed motors in home, office, factory, vehicles, aircraft, shipping, etc. Recently in compliance with performance and reliability and the applications of variable speed motors with invert driver are expanded. Almost high power inverter have IGBT and IGBT's fault cause motor system fault. If we can calculate and foresee troubles of IGBT, we can protect accident caused by motor system fault. In this paper, the deterioration test method of IGBT devices is proposed and the test results of proposed method are shown by evaluated equipment. The basic concept of proposed method is current-voltage characteristic curve test between drain and source of IGBT in open state. The applied voltage type is ramp and it is confirmed that the current-voltage curvet pattern of IGBT in open state represents IGBT's deterioration state.

  • PDF

Operation of a Single Flux Quantum 4-stage Shift Register Fabricated with High $T_c$ Ramp-edge Junction Technology (고온 초전도 경사형 모서리 접합을 이용한 4단 쉬프트 레지스터의 동작)

  • Kim, J. H.;Park, J. H.;Kim, S. H.;Jung, K. R.;Kang, J. H.;Sung, G. Y.;Hahn, T. S.
    • Progress in Superconductivity
    • /
    • v.3 no.1
    • /
    • pp.83-86
    • /
    • 2001
  • We have fabricated a single flux quantum 4-stage shift register with interface-controlled $Y_1$$Ba_2$$Cu_3$$O_{7-x}$(YBCO) Josephson junction. The YBCO Josephson junctions showed RSJ-like current-voltage(I-V) curves at temperatures 45~80K. We tested load and shift operation of shift register with binary data sequences “1000”, “1010”, “1011”, and “1111” at 58K. For all the binary data sequences, the shift register operated successfully. By operating the circuit with proper current pulses, we observed no errors during at least 12 hours operation for all the data sequences.s.

  • PDF

Ionic Dependence and Modulatory Factors of the Background Current Activated by Isoprenaline in Rabbit Ventricular Cells

  • Leem, Chae-Hun;Lee, Suk-Ho;So, In-Suk;Ho, Won-Kyung;Earm, Yung-E
    • The Korean Journal of Physiology
    • /
    • v.26 no.1
    • /
    • pp.15-25
    • /
    • 1992
  • In order to elucidate the properties of the background current whole cell patch clamp studies were performed in rabbit ventricular cells. Ramp pulses of ${\pm}80\;mV$ from holding potential of 40 mV(or 20 mV) at the speed of 0.8 V/sec were given every 30 sec(or 10 sec) and current-voltage diagrams(I-V curve) were obtained. For the activation of the background current isoprenaline, adenosine 3',5'-cyclic monophosphate(dBcAMP), guanosine 3',5'-cyclic monophosphate(cGMP), and $N^6$-2'-o-dibutyryladenosine 3',5'-cyclic monophosphate(dBcAMP) were applied after all known current systems were blocked with 2mM Ba, 1 mM Cd ,5 mM Ni, 10 ${\mu}M$ diltiazem, 10 ${\mu}m$ ouabain, and 20 mM tetraethylammonium(TEA). The conductance of background current in control was $0.65{\pm}0.69$ nS at 0 mV, its I-V curves was almost linear and reversed near 50 mV. When there was no taurine in pipette solution, isoprenaline hardly activated the background current but when taurine existed in pipette solution, isoprenaline activated the larger background current. Cyclic AMP or cyclic GMP alone had little effect on the activation of the background current, while cGMP potentiated cGMP effect. When the background current was activated with cGMP and cAMP, isoprenaline could not further increased the background current. The background current activated by isoprenaline depended on extracellular $Cl^-$ concentration and its reversal potential was shifted according to chloride equilibrium potential. The change of extracellular $Na+$ concentration had little effect on reversal potential of the background current activated by isoprenaline.

  • PDF

Effect of Metabolic Inhibition on Inward Rectifier K Current in Single Rabbit Ventricular Myocytes (토끼 단일 심근세포에서 대사억제시 Inward Rectifier$(I_{K1})$의 변화)

  • Chung, Yu-Jeong;Ho, Won-Kyung;Earm, Yung-E
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.1 no.6
    • /
    • pp.741-748
    • /
    • 1997
  • In the present study, we have investigated the effect of metabolic inhibition on the inward rectifier K current ($I_{K1}$). Using whole cell patch clamp technique we applied voltage ramp from +80 mV to -140 mV at a holding potential of -30 mV and recorded the whole cell current in single ventricular myocytes isolated from the rabbit heart. The current-voltage relationship showed N-shape (a large inward current and little outward current with a negative slope) which is a characteristic of $I_{K1}$. Application of 0.2 mM dinitrophenol (DNP, an uncoupler of oxidative phosphorylation as a tool for chemical hypoxia) to the bathing solution with the pipette solution containing 5 mM ATP, produced a gradual increase of outward current followed by a gradual decrease of inward current with little change in the reversal potential (-80 mV). The increase of outward current was reversed by glibenclamide ($10\;{\mu}M$), suggesting that it is caused by the activation of $K_{ATP}$. When DNP and glibenclamide were applied at the same time or glibenclamide was pretreated, DNP produced same degree of reduction in the magnitude of the inward current. These results show that metabolic inhibition induces not only the increase of $K_{ATP}$ channel but also the decrease of $I_{K1}$. Perfusing the cell with ATP-free pipette solution induced the changes very similar to those observed using DNP. Long exposure of DNP (30 min) or ATP-free pipette solution produced a marked decrease of both inward and outward current with a significant change in the reversal potential. Above results suggest that the decrease of $I_{K1}$ may contribute to the depolarisation of membrane potential during metabolic inhibition.

  • PDF

High Performance Current-Mode DC-DC Boost Converter in BiCMOS Integrated Circuits

  • Lee, Chan-Soo;Kim, Eui-Jin;Gendensuren, Munkhsuld;Kim, Nam-Soo;Na, Kee-Yeol
    • Transactions on Electrical and Electronic Materials
    • /
    • v.12 no.6
    • /
    • pp.262-266
    • /
    • 2011
  • A simulation study of a current-mode direct current (DC)-DC boost converter is presented in this paper. This converter, with a fully-integrated power module, is implemented by using bipolar complementary metal-oxide semiconductor (BiCMOS) technology. The current-sensing circuit has an op-amp to achieve high accuracy. With the sense metal-oxide semiconductor field-effect transistor (MOSFET) in the current sensor, the sensed inductor current with the internal ramp signal can be used for feedback control. In addition, BiCMOS technology is applied to the converter, for accurate current sensing and low power consumption. The DC-DC converter is designed with a standard 0.35 ${\mu}m$ BiCMOS process. The off-chip inductor-capacitor (LC) filter is operated with an inductance of 1 mH and a capacitance of 12.5 nF. Simulation results show the high performance of the current-sensing circuit and the validity of the BiCMOS converter. The output voltage is found to be 4.1 V with a ripple ratio of 1.5% at the duty ratio of 0.3. The sensing current is measured to be within 1 mA and follows to fit the order of the aspect ratio, between sensing and power FET.

Development of Prepolarization Coil Current Driver in SQUID Sensor-based Ultra Low-field Magnetic Resonance Apparatuses (SQUID 센서 기반의 극저자장 자기공명 장치를 위한 사전자화코일 전류구동장치 개발)

  • Hwang, S.M.;Kim, K.;Kang, C.S.;Lee, S.J.;Lee, Y.H.
    • Progress in Superconductivity
    • /
    • v.13 no.2
    • /
    • pp.105-110
    • /
    • 2011
  • SQUID sensor-based ultra low-field magnetic resonance apparatus with ${\mu}T$-level measurement field requires a strong prepolarization magnetic field ($B_p$) to magnetize its sample and obtain magnetic resonance signal with a high signal-to-noise ratio. This $B_p$ needs to be ramped down very quickly so that it does not interfere with signal acquisition which must take place before the sample magnetization relaxes off. A MOSFET switch-based $B_p$ coil driver has current ramp-down time ($t_{rd}$) that increases with $B_p$ current, which makes it unsuitable for driving high-field $B_p$ coil made of superconducting material. An energy cycling-type current driver has been developed for such a coil. This driver contains a storage capacitor inside a switch in IGBT-diode bridge configuration, which can manipulate how the capacitor is connected between the $B_p$ coil and its current source. The implemented circuit with 1.2 kV-tolerant devices was capable of driving 32 A current into a thick copper-wire solenoid $B_p$ coil with a 182 mm inner diameter, 0.23 H inductance, and 5.4 mT/A magnetic field-to-current ratio. The measured trd was 7.6 ms with a 160 ${\mu}F$ storage capacitor. trd was dependent only on the inductance of the coil and the capacitance of the driver capacitor. This driver is scalable to significantly higher current of superconducting $B_p$ coils without the $t_{rd}$ becoming unacceptably long with higher $B_p$ current.

Implementation of a Vector Control System of CRPWM Inverter Fed Induction Motor (CRPWM 인버터로 구동되는 유도전동기의 벡터제어 시스템 구현)

  • 김종진;김홍근
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.10 no.3
    • /
    • pp.55-63
    • /
    • 1996
  • In this paper, a vector control system is implemented to drive CRPWM inverter fed induction motor. The rotor flux is estimated using the rotor coordinates flux model and the stator coordinates ramp comparison controller is used as a current controller. The microcontroller 80C196 is used for the computation of the estimation of the rotor flux, the speed controller, the flux controller, the vector rotation, and the phase transformation The current controller is implemented using the analog circuit in order to reduce the burden of the microcontroller. For the proposed system, the digital simulation is performed to examine the feasibility and the superior characteristics of the current controller and the system transient response is verified through the experiment.

  • PDF

Gird-interactive PV Generation System with Power Quality Control (전력품질개선기능을 갖는 계통 연계형 태양광 발전시스템)

  • Lee, Seong-Ryong;Jeon, Chil-Hwan;Ko, Sung-Hun;Cho, Ah-Ran
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.994-995
    • /
    • 2006
  • This paper presents a grid-connected photovoltaic (PV) system with direct coupled power quality control (PQC) algorithm, which uses an inner current control loop (PRT : polarized ramp time) and outer feedback control loop to improve grid power quality and maximum power point tracking (MPPT) of PV arrays. To reduce the complexity, cost and number of power conversions, which results in higher efficiency, single stage CCVSI (Current Controlled Voltage Source Inverter) is used. The proposed system operation has been divided into two modes (sunny and night). In night mode, the proposed system operates to compensate the reactive power demanded by nonlinear or variation in loads. in sunny mode, the proposed system performs PQC to reduce harmonic current and improve power factor as well as MPPT to supply active power from the PV arrays simultaneously. it is shown that the proposed system improves the system utilization factor to 100% which is generally low for PV system (20%). To verify the proposed system, a comprehensive evaluation with theoretical analysis and simulation results are presented.

  • PDF

A Capacitance Deviation-to-Time Interval Converter Based on Ramp-Integration and Its Application to a Digital Humidity Controller (램프-적분을 이용한 용량치-시간차 변환기 및 디지털 습도 조절기에의 응용)

  • Park, Ji-Mann;Chung, Won-Sup
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.12
    • /
    • pp.70-78
    • /
    • 2000
  • A novel capacitance deviation-to-time interval converter based on ramp-integration is presented. It consists of two current mirrors, two schmitt triggers, and control digital circuits by the upper and lower sides, symmetrically. Total circuit has been with discrete components. The results show that the proposed converter has a linearity error of less than 1% at the time interval(pulse width) over a capacitance deviation from 295 pF to 375 pF. A capacitance deviation of 40pF and time interval of 0.2 ms was measured for sensor capacitance of 335 pF. Therefore, the high-resolution can be known by counting the fast and stable clock pulses gated into a counter for time interval. The application of a novel capacitance deviation-to time interval converter to a digital humidity controller is also presented. The presented circuit is insensitive to the capacitance difference in disregard of voltage source or temperature deviation. Besides the accuracy, it features the small MOS device count integrable onto a small chip area. The circuit is thus particularly suitable for the on-chip interface.

  • PDF

An Energy Efficient $V_{pp}$ Generator using a Variable Pumping Clock Frequency for Mobile DRAM (가변 펌핑 클록 주파수를 이용한 모바일 D램용 고효율 승압 전압 발생기)

  • Kim, Kyu-Young;Lee, Doo-Chan;Park, Jong-Sun;Kim, Soo-Won
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.6
    • /
    • pp.13-21
    • /
    • 2010
  • A energy efficient $V_{pp}$ generator using a variable pumping frequency for mobile DRAM is presented in this paper. The proposed $V_{pp}$ generator exploits 3 stages of a cross-coupled charge pump for energy efficiency. Instead of using a fixed pumping frequency in the conventional $V_{pp}$ generator, our proposed $V_{pp}$ generator adopts a voltage-controlled oscillator and uses variable frequencies to reduce the ramp-up time. As a result, our $V_{pp}$ generator generates 3.0 V output voltage with 24.0-${\mu}s$ ramp-up time at 2 mA current load and 1 nF capacitor load with 1.2 V supply voltage. Experimental results show that the proposed $V_{pp}$ generator consumes around 26% less energy (1573 nJ $\rightarrow$ 1162 nJ) and reduces 29% less ramp-up time (33.7-${\mu}s$ $\rightarrow$ 24.0-${\mu}s$) compared to the conventional approach.