• 제목/요약/키워드: Ramp Rate Control

검색결과 25건 처리시간 0.017초

풍력발전기의 출력 안정화를 위한 에너지 저장장치 용량 산정 사례연구 (Analysis on Required Capacity of Energy Storage System to Mitigate Wind Power Fluctuation)

  • 강민혁;채상헌;안진홍;김일환
    • 한국태양에너지학회 논문집
    • /
    • 제37권6호
    • /
    • pp.59-68
    • /
    • 2017
  • In accordance with the policy of local government, the large scale of wind farms have been installed in Jeju power system. However, The intermittent characteristics of wind power output may cause grid voltage and frequency variation, especially in weak power system. One of the solution to solve this problem is installation of Energy storage system (ESS). In this case, the ESS will regulate the active power generated from wind farm to mitigate fluctuation. Actually, the local government of Jeju island constructed ESS connected to Hangwon wind turbine in 2016. From this point, this paper analyzes requirement capacity of ESS to mitigate wind power fluctuation based on measured data from Hangwon wind turbine and ESS. The simulation results will be carried out by Matlab program.

전기식 온구기에 대한 안전성 및 성능 평가 가이드라인 개발 연구 (Study on Developing Assessment Guideline for Safety and Performance of Electric Moxibustion Apparatus)

  • 이승호;강중원;남동우;김은정;이혜정;김갑성;이재동
    • Journal of Acupuncture Research
    • /
    • 제27권1호
    • /
    • pp.75-86
    • /
    • 2010
  • Objectives : We developed and proposed a guideline for safety and performance assessment of electric moxibustion apparatus (class II medical device). Methods : We drafted the guideline for safety and performance assessment of electric moxibustion apparatus by referring the existing standards, guidelines and measurement data from commercially available products. Temperature characteristics such as maximum temperature and ramp time, and physical characteristics such as weight, noise and diameter were measured. User friendliness was also evaluated for commercial devices. Results : This guideline only can be applied to the electric moxibustion apparatus where moxa is being heated by electricity for medical proposes. Maximum temperature of higher than $50^{\circ}C$ can be achieved mostly. Ramp rate of temperature seems to be reliable. Control of temperature is needed to be improved. Moxa and its derivative products seem to be regulated for reliable temperature performance for clinical application. Requirements for design and development of electric moxibustion apparatus are suggested : temperature indicator, temperature control and its accuracy, safety measure, surge protection, user friendliness and instruction for use (IFU). Design recommendation of the reduction of noise level and energy loss are suggested for better products. Conclusions : We proposed a guideline for safety and performance assessment of electric moxibustion apparatus to improve the quality of relating products and aid their commercialization by aiming higher industrial competitiveness of the medical device sectors in Korea. Discussion with related institutes such as industry, academy and government is further required. Public hearings also need to be held prior to the establishment of a final guideline and standard.

수소 저장용 탱크의 튜브 형상에 따른 온도분포 특성에 대한 수치해석 연구 (A Study on the Characteristics of Temperature Distribution Related to Geometry of Tube in Hydrogen Storage Vessel)

  • 오승준;윤정환;전경숙;김재규;박준홍;최정주
    • 한국수소및신에너지학회논문집
    • /
    • 제32권4호
    • /
    • pp.205-211
    • /
    • 2021
  • Recently, it is necessary for study on renewable energy due to environmental pollution and fossil fuel depletion. Therefore, in this study, the filling temperature according to the nozzle geometry was evaluated based on the limit temperature specified in SAEJ2601 for charging hydrogen, a new energy. There are three types of nozzles, normal, angle and round, fixed the average pressure ramp rate at 52.5 MPa/min, and the injection temperature was set at 293.4 K. As a result, the lowest temperature distribution was found in the round type, although the final temperature did not differ significantly in the three types of nozzles. In addition, Pearson's coefficient was calculated to correlate the mass flow rate with the heat transfer rate at the inner liner wall, which resulted in a strong linear relationship of 0.98 or higher.

2000년대 국내 항공기 사고·준사고 발생유형 사례연구 (A case study on the Occurrence Category of aircraft accidents and serious incidents in Korea in the 2000's)

  • 최영재;안재형;유경인;박정권
    • 한국항공운항학회지
    • /
    • 제21권4호
    • /
    • pp.119-125
    • /
    • 2013
  • Since year 2001 to the present time, the aircraft accidents and serious incidents in our country have surpassed 150 occurrences. The Boeing has published the statistical summary of commercial jet airplane accidents annually for the past 10 years on the basis of the occurrence categories defined by the CICTT(CAST/ICAO Common Taxonomy Team), and the number of occurrences is in order of loss of control(LOC-I), controlled flight into terrain(CFIT) and runway excursion (RE). Like the NTSB and the EASA, when fatal and non-fatal accidents are aggregated, though fatality rate is low, abnormal runway contact(ARC), system/component failure(SCF-PP/NP), ground handling(RAMP) rank high in the CICTT occurrence categories. With the less occurrence frequency, it is difficult to statistically analyze the aircraft accidents in our country, thus customarily the accidents and the serious incidents on aggregate are consolidated, and the statistical analysis is performed. This study categorizes the accidents and serious incidents to the domestic transportation aircraft in the past 10 years according to the CICTT occurrence categories, that is compared with foreign practices, and the implications have been discussed. From years 2001 through 2010, the accidents to the domestic transportation aircraft occurred in order of system failure(SCF-NP), ARC and power plant failure(SCF-PP), and when the accidents and the serious incidents are consolidated and analyzed, it is verified that a distribution appears similar to the European accident occurrence categories defined from 300 accident occurrence data.

개 정자의 보존방법에 따른 첨체 및 생존성의 변화 1. 저온보존에 따른 효과 (Acrosomal Changes and Survivability of Following Preservation of Dog Spermatozoa I. The Effects of Different Chilling Duration)

  • 정정란;유재규;양성렬;여현진;박종식;예은하;노규진;최상용
    • 한국수정란이식학회지
    • /
    • 제16권1호
    • /
    • pp.35-40
    • /
    • 2001
  • Artificial insemination (AI) with frozen or cooled semen is widely used in commercial fields of cattle and pig. Little is known about characteristics of canine sperm after freezing or cooling. For both practical and commercial goal, the canine semen treated with cooling and freezing should be carried out to exam the fundamentals, including sperm motility, survivability and fertilizing capacity. The aim of this study, thus, was to identify the effects of extended exposure to 4$0^{\circ}C$ on canine semen by motility, survivability, acrosomal changes following different duration. Fifteen ejaculates collected by digital manipulation twice per week from 3 dogs (Shih-Tzu) were divided to 16 aliquots after adding Tris-egg yolk (TE) buffer formulated by our laboratory, and cooled from 37 to 4$^{\circ}C$, by ramp rate of 0.6$^{\circ}C$/min. Each sample was evaluated by their motility, survivability and the acrosomal status at 0h (control), 2h, 12h and 1 d~10 d, respectively. The motility of spermatozoa was graded to 6 levels using the modified method of Seager. The survivability of sperm was assessed using an epifluorescence microscope after Fert/Light (Mole-cular Probes Inc.) staining. To estimate the proportion of the spermatozoa of intact acrosome, 200 spermatozoa were assessed in randomly selected fields, using epifluorescence microscope after FITC/PSA (Sigma) staining. At 2 h after cooling, the motility of most spermatozoa were assessed to be grade 0 and 1. At 12 h, high number of sperm were in grade 0 to 1, however, it was significantly (P<0.05) lower than that of 2 h. From 1 d to 4 d, ~50% of sperm was assessed to grade 0 to 1. On day 7, a little sperm were in grade 0 to 1. No sperm showed motility on day 10. Sperm motility was rapidly reduced by the percent of 10% of grade 0 to 1. From 2 h to 6 h, the number of live sperm was 90% and the sperm chilled for 10 days lived>50%. Acrosomal intact of spermatozoa exposed to 4$^{\circ}C$ for 2 h was 51%, supposed the sperm of control was 100%. Our results suggest that 1) this is easy to transfer and preservation for short periods 2) AI can be used by semen chilled for 6-Day.

  • PDF