• Title/Summary/Keyword: Rainfall-runoff Relationship

Search Result 139, Processing Time 0.023 seconds

Characteristics of Pollutant Loading from Paddy Field Area with Groundwater Irrigation (지하수 관개지역 논에서의 배출부하 특성)

  • 윤춘경;김병희;전지홍;황하선
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.44 no.5
    • /
    • pp.116-126
    • /
    • 2002
  • Discharge pattern and water quality were investigated in the drainage water from about 10 ha of groundwater-irrigated paddy field in the growing season of 2001. Total discharge quantity was about 1,117.2 mm in which about 75% was caused by management drainage due to cultural practice of paddy rice farming and the rest by rainfall runoff where total rainfall was about 515 mm. Dry-day sampling data showed wide variations in constituent concentrations with average of 26.14 mg/L, 0.37 mg/L, 3.54 mg/L at the inlet, and 43.60 mg/L, 0.34 mg/L, 3.58 mg/L at the outlet for CO $D_{cr}$ , T-P, and T-N, respectively. Wet-day sampling data demonstrated that generally CO $D_{cr}$ followed the discharge pattern and T-P was in opposite to the discharge pattern, but T-N did not show apparent pattern to the discharge. Discharge and load are in strong relationship. And based on regression equation, pollutant loads from groundwater irrigation area are estimated to be 288.34, 1.17, and 5.45 kg/ha for CO $D_{cr}$ , T-P, and T-N, respectively, which was relatively lower than the literature value from surface water irrigation area which implies that groundwater irrigation area might use less irrigation water and result in less drainage water, Therefore, total pollutant load from paddies irrigation with groundwater could be significantly lower than that with surface water. This study shows that agricultural drainage water management needs a good care of drainage outlet as well as rainfall runoff. This study was based on limited monitoring data of one year, and further monitoring and successive analysis are recommended for more generalized conclusion.

Effect and Control of the Sediment in the Combined Sewer on CSOs (합류식 하수관거내 퇴적물이 CSOs에 미치는 영향 및 제어방안)

  • Lim, Bongsu;Kim, Doyoung;Lee, Kuangchun
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.1
    • /
    • pp.36-43
    • /
    • 2011
  • This study is selected two points of combined sewer that occurred Fish Kill after first flush, that analyzed generation of pollutants and stream runoff generation of combined sewer overflows (CSOs) as fine weather and rainfall. In addition, this study was to analyze the relationship between CSOs and sediments, to propose measures to reduce the sediment relevant with CSOs and rainfall runoff from entering sewage treatment plants and measures for discharged directly into streams when indicate relatively good water quality after overflow. Sediments in combined sewer system was discharged about 50~80% as overflows during rainfall and we can reduce the amount of the CSOs at least 50% or more if the sewer does not exist in the sediments because of the amount of discharge about the amount of intercept has been investigated by 3~5 times. Because of velocity at sediment interval in sewer is very low, sewage velocity of about 3~5 times as much as it can increase the amount of sediment can be reduced if the separation wall is installed. Effective control of BOD overflow load is respectively 77.5%, 75.8% at first point, second point by the separation wall is installed. Drainage area greater than area in this study or many combined sewer overflows region is increased the more effective control of separation wall. Turbidity to measure changes in water quality of overflows can be used as an factor to control the intercept flows because the intercept flows(3Q) after the first flush has lowered removal efficiency and increases the operational load of sewage treatment plants. Sewage water quality after a overflow when the reasonable turbidity was measured at this point flows to excluded intercept flow(1Q) can be discharged to stream.

Development of a Comprehensive Flood Index through Standardizing Distributions of Runoff Characteristics (유출특성 분포함수의 표준화를 통한 종합홍수지수의 개발)

  • Wi, Sung-Wook;Chung, Gun-Hui;Kim, Tae-Woong
    • Journal of Korea Water Resources Association
    • /
    • v.41 no.6
    • /
    • pp.605-617
    • /
    • 2008
  • This study developed a flood index which evaluates runoff characteristics. Runoff characteristics expressed in a hydrograph were reflected in the flood index in the form of characteristic factors such as a rising curve gradient, a peak discharge, a flood response time, and a flood discharge volume prior to peak. This study applied the standardization method to estimate the relative severity of the characteristic factors by transforming the distribution of characteristic factors into the standard normal distribution. The flood index developed in this study is a comprehensive flood index (CFI) which makes up for the weak points of a flash flood index (FFI) in determining relative severities. The CFI was applied to Han River basin and Selma River basin, and was compared with the FFI based on the correlation analysis and the regression analysis. The CFI could comprehensively evaluate flood runoff characteristics because the CFI is not dominated by a specific characteristic factor, and the CFI could explain more efficiently the relationship between rainfall and runoff than the FFI.

Characteristics of NPS Pollution from a Coal Mining (가행광산 지역의 비점오염물질 유출특성)

  • Seo, Jiyeon;Shin, Minhwan;Won, Chul-hee;Choi, Yong-hun;Jung, Myung-suk;Lim, Kyoung Jae;Choi, Joongdae
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.3
    • /
    • pp.474-481
    • /
    • 2010
  • This study was conducted to describe the characteristics of Non-point source (NPS) Pollution discharge from a coal mining area in Korea. The study areas is located on the Dogye site, Samchuk, Kangwon Province Coal Corporation and the Jangsung site, Taebaek, Kangwon Province Coal Corporation. The monitoring system was installed at a drainage channel and water samples and rainfall events were collected during March 2008 to February 2009. The collected water samples were analyzed with respect to SS, BOD, $COD_{Cr}$, $COD_{Mn}$, T-N, T-P, and TOC, respectively. It was observed that the runoff and water quality were largely influenced by mine drainage. Also a significant relationship was observed from the correlation between flow and water quality, flow and NPS. And estimated Event Mean Concentration (EMC), NPS pollution loads were Dogey coal mine and Taeback coal mine respectively. As the study progresses in the future, runoff and pollution loads will be updated.

Experimental study of rainfall spatial variability effect on peak flow variability using a data generation method (자료생성방법을 사용한 강우의 공간분포가 첨두유량의 변동성에 미치는 영향에 대한 실험적 연구)

  • Kim, Nam Won;Shin, Mun Ju
    • Journal of Korea Water Resources Association
    • /
    • v.50 no.6
    • /
    • pp.359-371
    • /
    • 2017
  • This study generated flood time series of ungauged catchments in the Andongdam catchment using a distributed rainfall-runoff model and data generation method, and extracted the peak flows of 50 catchments to investigate the effect of rainfall spatial variability on peak flow simulation. The model performance statistics for three gauged catchments were reasonable for all events. The flood time series of the 50 catchments were generated using distributed and mean rainfall time series as input. The distribution of the peak flow using the mean rainfall was similar or slightly different to that using the distributed rainfall when the distribution of the distributed rainfall was nearly uniform. However, the distribution of the peak flow using the mean rainfall was reduced significantly compared to that using the distributed rainfall when actual storms moved to the top or bottom of the study catchment, or the rainfall was randomly distributed. These cases were 35% of total number events. Therefore, the spatial variability of rainfall should be considered for flood simulation. In addition, the power law relationship estimated using the peak flow of gauged catchments cannot be used for estimating the peak flow of ungauged independent catchments due to latter's significant variation of the peak flow magnitude.

Influences of Forest Environmental Factors on Turbidity of Stream Water (산림환경인자가 계류수의 탁수화에 미치는 영향)

  • Ma, Ho-Seop;Kang, Won-Seok;Kang, Eun-Min
    • Journal of Korean Society of Forest Science
    • /
    • v.101 no.4
    • /
    • pp.574-578
    • /
    • 2012
  • This study was carried out to clarify the influences of forest environmental factors on turbidity of Stream water on three stands (Castanea crenata, Pinus densiflora and Plantation Land) of small watershed in Samgyeri Naedong-myeon Jinju-si Gyeongsangnam-do. The relationship between turbidity and forest environmental factors was a positive correlation at 1% level with chromaticity, suspended solid, sediment runoff erosion, slope, rainfall intensity, preceding dry days, watershed area and stream length and at 5% level with accumulative rainfall. The important factors that affected turbidity in small watershed showed in order of preceding dry days, rainfall intensity, stream length, chromaticity and suspended solid. In the stepwise regression between turbidity and forest environmental factors, the estimation equation is as follow; Y=-28.125+0.047x (suspended solid)+0.058x (chromaticity)+1.518x (rainfall intensity)+0.264x (stream length)+1.837x (preceding dry days). The results indicates that dangerous areas of landslide and soil runoff by land use could be applied to the mitigation measures such as afforestation, erosion check dam and revetment for erosion control and water quality management in small watershed.

Improvement of Mid-and Low-flow Estimation Using Variable Nonlinear Catchment Wetness Index (비선형 유역습윤지수를 이용한 평갈수기 유출모의개선)

  • Hyun, Sukhoon;Kang, Boosik;Kim, Jin-Gyeom
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.36 no.5
    • /
    • pp.779-789
    • /
    • 2016
  • The effective rainfall is calculated considering the soil moisture. It utilizes observed data directly in order to incorporate the soil moisture into the rainfall-runoff model, or it calculates indirectly within the model. The rainfall-runoff model, IHACRES, used in this study computes the catchment wetness index (CWI) first varying with temperature and utilize it for estimating precipitation loss. The nonlinear relationship between the CWI and the effective rainfall in the Hapcheondam watershed was derived and utilized for the long-term runoff calculation. The effects of variable and constant CWI during calibration and validation were suggested by flow regime. The results show the variable CWI is generally more effective than the constant CWI. The $R^2$ during high flow period shows relatively higher than the ones during normal or low flow period, but the difference between cases of the variable and constant CWI was insignificant. The results indicates that the high flow is relatively less sensitive to the evaporation and soil moisture associated with temperature. On the other hand, the variable CWI gives more desirable results during normal and low flow periods which means that it is crucial to incorporate evaporation and soil moisture depending on temperature into long-term continuous runoff simulation. The NSE tends to decrease during high flow period with high variability which could be natural because NSE index is largely influenced by outliers of underlying variable. Nevertheless overall NSE shows satisfactory range higher than 0.9. The utilization of variable CWI during normal and low flow period would improve the computation of long-term rainfall-runoff simulation.

Estimation of Pollutants Loading from Non-Point Sources Based on Rainfall Event and Land use Characteristics (강우강도와 토지이용을 고려한 비점오염물질 부하량 산정에 관한 연구)

  • Lee, Hye-Won;Choi, Nam-Hee;Lee, Yong-Seok;Choi, Jung-Hyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.8
    • /
    • pp.572-577
    • /
    • 2011
  • The unit load has simply been used to estimate total pollutant loading from non-point sources, however, it does not count on the variable pollutant loading according to land use characteristics and rainfall intensity. Since pollutant emission from the watershed is strongly dependent on the rainfall intensity, it is necessary to find out the relationship between pollutant loading and rainfall intensity. The objective of this study is to develop simple and easy method to compute non-point source pollution loads with consideration of rainfall intensity. Two non-point source removal facility at Gyeongan-dong (Gwangju-si) and Mohyeon-myeon (Yongin-si), Gyeonggi-do was selected to monitor total rainfall, rainfall intensity, runoff characteristics and water quality from June to November, 2010. Most of Event Mean Concentrations (EMC) of measured water quality data were higher in Gyeongan which has urban land use than in Mohyeon which has rural land use. For the case of TP (Total Phosphorus), Mohyeon has higher values by the influence of larger chemical uses such as fertilizer. The relationship between non-point source pollution load and rainfall intensity is perfectly well explained by cubic regression with 0.33~0.81 coefficients of determination($R^2$). It is expected that the pollution loading function based on the long-term monitoring would be very useful with good accuracy in computing non-point source pollution load, where a rainfall intensity is highly variable.

Estimating Runoff Curve Numbers for Paddy Fields (논의 유출곡선번호 추정)

  • Im, Sang-Jun;Park, Seung-U
    • Journal of Korea Water Resources Association
    • /
    • v.30 no.4
    • /
    • pp.379-387
    • /
    • 1997
  • This study involves field monitoring of hydrlolgic characteristics of paddy fields under common irrigation practice, statistical analysis of maximum retention storage, determination of CNs for antecedent moisture conditions. Curve numbers were estimated from observed rainfall-runoff relationship of two years data. The estimated CN for AMC-II was 78, and the CNs for AMC-I and II were 63 and 88, respectively. A water balance model was used to find the effect of ridge height changes and initial ponding depth in paddy fields on runoff. The probability distribution of initial ponding depth was also investigated. The initial ponding depth follows normal probability distribution. Initial ponding depth corresponding 10%, 50%, and 90% probability were considered to be equivalent to AMC-I, AMC-II, and AMC-III, respectively. Long-term runoff data from paddy fields were simulated by a water balance model using recorded climate data, ridge height and estimated initial ponding depth derived from probability distribution. The estimated CNs using simulated runoff were 70, 79, and 89 for CN-I, CN-II, and CN-III, respectively.

  • PDF

Adjustment of TRM/PR Data by Ground Observed Rainfall Data and SCS Runoff Estimation : Yongdam-Dam Watershed (지상강우 관측치에 의한 TRM/PR 관측치의 보정 및 SCS 유출해석 : 용담댐 유역을 대상으로)

  • Jang, Cheol-Hee;Kwon, Hyung-Joong;Koh, Deok-Ku;Kim, Seung-Joon
    • Journal of Korea Water Resources Association
    • /
    • v.36 no.4
    • /
    • pp.647-659
    • /
    • 2003
  • The purpose of this study is to evaluate hydrological applicability of spatially observed rainfall distribution data by the TRMM/PR (Tropical Rainfall Measuring Mission / Precipitation Radar). For this study, firstly, TRMM/PR data (Y) of the Yongdam-Dam Watershed (930.38$km^2$) was extracted and secondly, TRMM/PR data and the rainfall data (X) by AWS (Automatic Weather Station) were compared by executing a correlation analysis. As a result, the regression equations were deduced as two parts (under 60mm/day : Y = 18.55X-0.53, over 60mm/day : Y = 3.11X+51.16). SCS runoff analysis was conducted using 7 rainfall events in 1999 for Yongdam-Dam watershed and the Cheon-Cheon subwatershed for the revised TRMM/PR data. TRMM/PR data showed relative errors ranging from 19.6% ti 45.6%, and from 11.3% to 38.9% for Cheon-Cheon subwatershed and Yongdam-Dam watershed, respectively, AWS data showed relative errors ranging from 0.5% to 12.8%, and from -1.6% to -10.3%, for Cheon-Cheon subwatershed and Yongdam-Dam watershed, respectively. Futher researches are necessary to evaluate the relationship between TRMM/PR data and AWS data for practical hydrological applications.