• Title/Summary/Keyword: Railroad-tunnel

Search Result 233, Processing Time 0.031 seconds

Installation Standards of Urban Deep Road Tunnel Fire Safety Facilities (도심부 대심도 터널의 방재시설 설치 기준에 관한 연구(부산 승학터널 사례를 중심으로))

  • Lee, Soobeom;Kim, JeongHyun;Kim, Jungsik;Kim, Dohoon;Lim, Joonbum
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.6
    • /
    • pp.727-736
    • /
    • 2021
  • Road tunnel lengths are increasing. Some 1,300 tunnels with 1,102 km in length had been increased till 2019 from 2010. There are 64 tunnels over 3,000 m in length, with their total length adding up to 276.7 km. Safety facilities in the event of a tunnel fire are critical so as to prevent large-scale casualties. Standards for installing disaster prevention facilities are being proposed based on the guidelines of the Ministry of Land, Infrastructure and Transport, but they may be limited to deep underground tunnels. This study was undertaken to provide guidelines for the spacing of evacuation connection passages and the widths of evacuation connection doors. Evacuation with various spacing and widths was simulated in regards to evacuation time, which is the measure of safety, using the evacuation analysis simulation software EXODUS Ver.6.3 and the fire/smoke analysis software SMARTFIRE Ver.4.1. Evacuation connection gates with widths of 0.9 m and 1.2 m, and spacings of 150 m to 250 m, were set to every 20 m. In addition, longitudinal slopes of 6 % and 0 % were considered. It was determined to be safe when the evacuation completion time was shorter than the delay diffusion time. According to the simulation results, all occupants could complete evacuation before smoke spread regardless of the width of the evacuation connection door when the longitudinal slope was 6 % and the interval of evacuation connection passage was 150 m. When the evacuation connection passage spacing was 200 m and the evacuation connection gate width was 1.2 m, all occupants could evacuate when the longitudinal slope was 0 %. Due to difference in evacuation speed according to the longitudinal slope, the evacuation time with a 6 % slope was 114 seconds shorter (with the 190 m connection passage) than with a 0 % slope. A shorter spacing of evacuation connection passages may reduce the evacuation time, but this is difficult to implement in practice because of economic and structural limitations. If the width of the evacuation junction is 1.2 m, occupants could evacuate faster than with a 0.9 m width. When the width of a connection door is 1.2 m with appropriate connection passage spacing, it might provide a means to increase economic efficiency and resolve structural limitations while securing evacuation safety.

Analysis of Aerodynamic Noise Generation from Pantograph Using Panhead Models of Simple-Geometry and Its Reduction (팬헤드의 단순 형상 모델을 이용한 판토그라프 공력소음 발생 특성 분석 및 저감 방안)

  • Yi, Suk-Keun;Yang, Won-Seok;Koh, Hyo-In;Park, Junhong
    • Journal of the Korean Society for Railway
    • /
    • v.15 no.6
    • /
    • pp.531-536
    • /
    • 2012
  • This study presents a result on aero-acoustic characteristics of pantograph panheads. To analyze the fluid flow around the panhead and resulting sound radiation, simple models of panhead were used in the numerical simulations called Lattice-Boltzmann method. The simulation results were verified using the wind tunnel test. The main aerodynamic noise was generated from the vortex shedding which is characterized by the Strouhal number, flow speed and geometry. The reduction in the radiated noise with simultaneously achieving increased lifting force was implemented for the simple rectangular geometry used in this study. Also, it was shown that the radiated sound power was significantly reduced by minimizing vortex shedding using through-holes or streamline shapes.

AN INVESTIGATION ON HVLS FAN PERFORMANCE WITH DIFFERENT BLADE CONFIGURATIONS (날개 형상에 따른 HVLS의 성능에 관한 연구)

  • Moshfeghi, Mohammad;Hur, Nahmkeon;Kim, Young Joo;Kang, Hyun Wook
    • Journal of computational fluids engineering
    • /
    • v.19 no.4
    • /
    • pp.80-85
    • /
    • 2014
  • High-volume low-speed (HVLS) fans are one category of ceiling fan installed in large enclosings such as warehouses, large barns and health clubs in order to generate comfortable air circulation. As a rotary blade, aerodynamic performance of a HVLS fan is predominantly related to its airfoil(s), and the pitch and twist angles. This paper first, investigates the effects of airfoil on the performances of three different HVLS fans with NACA 5414, 6413 and 7415 airfoils. The fans have six untwisted blades with the diameter of 6 m and rotate at 60 RPM. The blades pitch angels are $12^{\circ}$, $12^{\circ}$ and $13^{\circ}$, respectively. The results are presented in the form of the aerodynamic forces and moments, volumetric flow rate and streamlines. Regarding the volumetric flow of air, the results show that the model with NACA 7415 has the best performance. Hence, two other HVLS fans with the same airfoil but, with four and five blades are studied in order to investigate the effects of number of blades. From the point of view of air circulation still the six-bladed fan is the best one; however, the five-bladed fan is more efficient in power consumption.

Development of Practical Rock Slope Hazard Evaluation Method (현장실무자용 암반사면 위험도평가법 개발)

  • Jung, Yong-Bok;SunWoo, Choon;Lee, Byung-Joo;Song, Won-Kyong
    • Tunnel and Underground Space
    • /
    • v.17 no.4
    • /
    • pp.322-331
    • /
    • 2007
  • Hundreds of rock slopes are constructed along the road, highway and railroad in mountainous Kangwon province and managed by each authorities concerned. It is practically not possible to carry out detailed rock slope investigation owing to the tremendous number of slopes and budgetary limit. Therefore, it is reasonable to perform a step-by-step investigation consisted of basic and detailed survey program and practical rock slope hazard assesment method for person in charge is strongly required. Through the development and application of KSMR (Korean Slope Mass Rating), it was found that KSMR could be practically used as an alternative of SMR though the number of inputs were reduced. In addition, the difference of hazard assessment between KSMR and experts decreased in case of considering the height of slope.

Load Bearing Capacity Evaluation of New Lattice Girder by Laboratory Test Techniques (실내평가기법에 의한 새로운 격자지보재의 하중지지력 평가)

  • Choi, Young-Nam;Kim, Dong-Gyou;Bae, Gyu-Jin;Jang, Yeon-Soo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.666-672
    • /
    • 2010
  • Load bearing capacity of new lattice girder has been evaluated with optimized spider for lattice girder utilized in the construction of tunnels. This newly developed lattice girder is different from existing lattice girder as its design is associated with existing spider with newly developed 2 types of form. The spacing of lattice girder's spider is linked with the weight and it decides the unit cost and construction therefore, different spacing of the developed spider has been produced to evaluate the measurement of load bearing capacity. As the result of the tests by producing the spacing of spider as 0cm and 4cm for developed lattice girder-2, the load bearing capacity of 0cm with spacing of 21%, and 4cm with 25% of increase when they are compared with the existing lattice girder, and the weight of specimen was decreased. As the result of the tests by producing the spacing of 1cm and 6cm for developed lattice girder-3, the spacing of 1cm with 42%, and the spacing of 6cm with 11% of increase which presented higher load bearing capacity in all newly developed forms, and there was a certain degree of increase in weight in case of 1cm of spacing. The result of evaluation regarding on the displacement by applying the evaluation method suggested by the German Railroad administration, the entire specimens were found to satisfy all the evaluation standard suggested by the administration.

  • PDF

Review of Collision Avoidance Systems for Mine Safety Management: Development Status and Applications (광산안전관리를 위한 충돌방지시스템의 개발현황과 적용사례)

  • Lee, Chaeyoung;Suh, Jangwon;Baek, Jieun;Choi, Yosoon
    • Tunnel and Underground Space
    • /
    • v.27 no.5
    • /
    • pp.282-294
    • /
    • 2017
  • This study analyzed the development status and applications of collision avoidance systems for mine safety management. The definitions of collision avoidance system used in Australia and USA were compared. Sensing technologies utilized in the collision avoidance systems were reviewed. In addition, several collision avoidance systems developed in oversea mining company, such as $MineAlert^{TM}$ Collision Awareness System, Cat $MineStar^{TM}$, and Intelligent Proximity Detection, were reviewed. In the domestic mining industry, no collision avoidance system was used. However, similar systems were utilized in the construction and railroad industry. Collision avoidance system can prevent unexpected collision accident and thus improve worker's safety in mine. Therefore, it is necessary to analyze and apply sensors and system appropriate for the domestic mining environment via review of overseas collision avoidance system.

Evaluation of Train Running Safety for Direct Fixation Concrete Track on Light Rapid Transit (경전철 직결식 콘크리트 궤도구조의 열차주행안전성 평가)

  • Choi, Jung-Youl;Kim, Jun-Hyung;Chung, Jee-Seung;Lee, Sun-Gil
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.5
    • /
    • pp.41-46
    • /
    • 2017
  • The coefficient of derailment and the rate of wheel load reduction were used as the index of train running safety that was directly affected the train derailment safety. In aspects of track, the train running safety depends on the complex interaction between wheel and rail, and the track-vehicle conditions (i.e., the curvature, cant, track system, vehicle speed and the operation conditions, etc). In this study, the relationship between the train running safety and the track curvature and vehicle speed for direct fixation concrete tracks currently employed in Korean light rapid transit was assessed by performing field tests using actual vehicles running along the service lines. The measured dynamic wheel load, lateral wheel load and lateral displacement of rail head were measured for same train running on four tested tracks under real conditions, which included curved and tangent tracks placed on the tunnel and bridge, thus increasing the train speed by approximately maximum design speed of each test site. Therefore, the measured dynamic track response was applied to the running safety analysis in order to evaluate the coefficient of derailment, the rate of wheel load reduction and the track gauge widening at each test site, and compare with the corresponding Korean train running safety standard. As the results, the lateral track response of direct fixation concrete track appeared to increase with the decreased track curvature; therefore, it was inferred that the track curvature directly affected the train running safety.

Lumped Parameter Modeling and Analysis of Electromagnetic Vibration Exciter for Vibrating Rapper of Electrostatic Precipitator (전기 집진기의 진동 탈진을 위한 전자기 진동 가진기의 집중매개변수 모델링 및 해석)

  • Kim, Je-Hoon;Lee, Jung-Hun;Kim, Jin-Ho;Jeong, Sang-Hyun;Han, Bang-Woo
    • Journal of the Korean Magnetics Society
    • /
    • v.21 no.2
    • /
    • pp.61-66
    • /
    • 2011
  • The miniaturization of electrostatic precipitator is becoming a key element to the success of the efficient electrostatic precipitator due to the limited space allowed to install electrostatic precipitator in subway tunnel. Nowadays, a research on electrostatic precipitator in urban railroad equipment technology is under an active study. Finite element method has been used one of the most popular techniques, but it consumes a lot of time especially in computation iterations. Accordingly, the lumped parameter analysis can be an alternative tool to FEM because of its computation iteration capability with fair accuracy. In this paper, lumped parameter model and the simulation results are presented. In addition, the result of lumped parameter analysis is compared with those obtained from finite element analysis for verification.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2010 (설비공학 분야의 최근 연구 동향 : 2010년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwa-Taik;Lee, Dae-Young;Kim, Seo-Young;Choi, Jong-Min;Kim, Su-Min;Kwon, Young-Chul;Baik, Yong-Kyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.6
    • /
    • pp.449-469
    • /
    • 2011
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering during 2010. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends of thermal and fluid engineering have been surveyed as groups of general thermal and fluid flow, fluid machinery, and new and renewable energy. Various topics were presented in the field of general thermal and fluid flow. Research issues mainly focused on the thermal reliability of axial fan and compressor in the field of fluid machinery. Studies on the design of ground source heat pump systems and solar chemical reactors were executed in the field of new and renewable energy. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included heat transfer in thermoelectric cooling/power generation systems, combined heat and power systems, carbon nano fluid with PVP, channel filled with metal foam and smoke ventilation in a rescue station of a railroad tunnel. Also the studies on flow boiling of R123/oil mixture in a plain tube bundle and R410A charge amount in an air cooled mini-channel condenser were reported. In the area of industrial heat exchangers, researches on plate heat exchanger, shell and tube heat exchanger, enthalpy exchanger, micro channel PCHE were performed. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included heat transfer in thermoelectric cooling/power generation systems, combined heat and power systems, carbon nano fluid with PVP, channel filled with metal foam and smoke ventilation in a rescue station of a railroad tunnel. Also the studies on flow boiling of R123/oil mixture in a plain tube bundle and R410A charge amount in an air cooled mini-channel condenser were reported. In the area of industrial heat exchangers, researches on plate heat exchanger, shell and tube heat exchanger, enthalpy exchanger, micro channel PCHE were performed. (3) Refrigeration systems with alternative refrigerants such as hydrocarbons, mixed refrigerants, and CO2 were studied. Performance improvement of refrigeration systems are tried applying various ideas of refrigerant subcooling, dual evaporator with hot gas bypass control and feedforward control. The hybrid solar systems combining the solar collection devices with absorption chillers or compression heat pumps are simulated and studied experimentally as well to improve the understanding and the feasibility for actual applications. (4) Research trend in the field of mechanical building facilities has been found to be mainly focused on field applications rather than performance improvements. Various studies on heating and cooling systems, HVAC facilities, indoor air environments and energy resources were carried to improve the maintenance and management of building service equipments. In the field of heating and cooling systems, papers on a transformer cooling system, a combined heat and power, a slab thermal storage and a heat pump were reported. In the field of HVAC facilities, papers on a cooling load, an ondol and a drying were presented. Also, studies on HVAC systems using unutilized indoor air environments and energy resources such as air curtains, bioviolence, cleanrooms, ventilation, district heating, landfill gas were studied. (5) In the field of architectural environment and energy, studies of various purposes were conducted such as indoor environment, building energy, renewable energy and green building. In particular, renewable energy and building energy-related researches have mainly been studied reflecting the global interest. In addition, many researches which related the domestic green building certification of school building were performed to improve the indoor environment of school.

Evaluation on Temperature of FSW Zone of Magnesium Alloy using Experiment and FE Analysis (시험 및 유한요소법을 이용한 마그네슘 합금 마찰교반용접부 온도 특성 평가)

  • Sun, Seung-Ju;Kim, Jung-Seok;Lee, Woo-Geun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.7
    • /
    • pp.434-441
    • /
    • 2016
  • Friction Stir Welding (FSW) is a solid-state joining process involving the frictional heat between the materials and tools. The amount of heat conducted into the workpiece determines the quality of the welded zone. Excessive heat input is the cause of oxides and porosity defects, and insufficient heat input can cause problems, such as tunnel defects. Therefore, analyzing the temperature history and distribution at the center of the Friction Stir Welded zone is very important. In this study, the temperature distribution of the friction stir welding region of an AZ61 magnesium alloy was investigated. To achieve this goal, the temperature and metal flow was predicted using the finite element method. In FE analysis, the welding tool was simplified and the friction condition was optimized. Moreover, the temperature measuring test at the center of the welding region was performed to verify the FE results. In this study, the tool rotation speed was a more dominant factor than the welding speed. In addition, the predicted temperature at the center of the welding region showed good agreement with the measurement results within the error range of 5.4% - 7.7%.