• Title/Summary/Keyword: Railroad Passenger Cabin

Search Result 17, Processing Time 0.035 seconds

Aerodynamic analysis for train operation without the effect of the passenger ear-discomfort in tunnel of new Seoul-Chunchon line (경춘선 1급 신설터널에서 열차승객의 이명감 없이 주행 가능한 열차속도에 대한 연구)

  • 김동현
    • Proceedings of the KSR Conference
    • /
    • 2000.05a
    • /
    • pp.495-502
    • /
    • 2000
  • For the tunnel design of the first class on new Seoul-Chunchon railway, we investigated for train speeds to run through tunnels without ear-discomfort of passenger in cabin by application of numerical analysis. Also we analyzed the effect of the wind speed induced by train in tunnel that is very harmful to the workers on railroad and the effect of the air-pressure fluctuations which get the fatigue to the tunnel lining and the car body.

  • PDF

Study on the Removal of Carbon Dioxide in Passenger Cabin using Base-Modified Zeolites (염기 처리 제올라이트를 이용한 객실용 이산화탄소 저감방안 연구)

  • Cho, Young-Min;Lee, Ji-Yun;Kwon, Soon-Bark;Park, Duck-Shin;Choi, Jin-Shik;Kim, Hee-Man
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.544-547
    • /
    • 2011
  • Carbon dioxide concentration of railroad passenger cabin is obliged to be kept lower than guideline values of 'Indoor air quality guideline for public transportations', but actual carbon dioxide concentration frequently exceeds this guideline value. Ventilation is most desirable to lower carbon dioxide concentration but there are some cases when the ventilation is not applicable. In this study, carbon dioxide concentration control method using adsorbents was presented. Base and zeolites, good adsorbents of carbon dioxide, were mixed and palletized. Carbon dioxide adsorption performance of this adsorbents were studied. It was found that base-modified zeolites adsorbed carbon dioxide better than zeolites only.

  • PDF

A Study for Characteristics of PM10 in the Subway Passenger Cabins (지하철 전동차 객실에서의 PM10 오염특성 파악에 관한 연구)

  • Oh, Mi-Seok;Park, Duck-Shin;Park, Eun-Young
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.5
    • /
    • pp.523-533
    • /
    • 2011
  • This study had the aim of characteristics of $PM_{10}$ in subway cabins. $PM_{10}$ was measured by times of day (rush and non rush hours) and seasons with real time $PM_{10}$ sampler on the subway cabins of line 7. Filter samples were collected for evaluation of their elemental composition as well as identification of major sources of $PM_{10}$ using a receptor model, PMF. $PM_{10}$ concentration were the highest in the winter season both in the rush and non rush hours at 152.8 ${\mu}g/m^3$, 90.2 ${\mu}g/m^3$ respectively. The $PM_{10}$ concentrations in rush hour were 30% higher compared to non rush hours. Based on the chemical information, the composition rare of inorganic elements was 52.5%, anions were 10.2% and others were 37.3%. Fe was the most abundant element and significantly correlated (p.0.01) with Mn (r=0.97), Ti (r=0.91), Cr (r=0.88), Ni (r=0.89) and Cu (r=0.88). Characterized $PM_{10}$ sources by PMF in the cabin were soil and road dust related sources (27.2%), railroad related sources (47.5%), secondary nitrate sources (16.2%) and a Cl-factor mixed with a secondary sulfate source (9.1%).

Development of Air Cleaning System for Railroad Vehicles (차세대 객차용 청정시스템 개발)

  • Park, Duck-Shin;Cho, Young-Min;Kwon, Soon-Bark;Park, Eun-Young;Kim, Se-Young;Jung, Mi-Young
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.2109-2113
    • /
    • 2008
  • As the standard of living is higher, the passengers using public transportations desire better qualities of environment as well as more comfortable indoor environment. In case of train, the passengers' comfort in passenger cabin is one of the most important elements to be competitive with other transport systems. The indoor air quality of the cabin should be managed properly, because many passengers travel for a long time in the small space of $144\;m^3$. For proper management of the air quality, the heating, ventilation and air conditioning (HVAC) system is required for the ventilation of the compartment. To maintain comfortable environment in the compartment, the automatic ventilation system is needed to exchange the indoor air with fresh air or clean indoor air. In this study, we investigated the indoor air quality (PM-10, $CO_2$, and VOCs) in the compartment of train. In addition, type and pattern of PM-10 has been analyzed through the clustering analysis. Based on the analysis, we could found that the fine particulate matters in the compartment can be a serious hazard to human. To control the concentration of PM-10 and $CO_2$ air cleaners were developed. Through this study, it is expected that people who take a train will be in a more comfortable environment.

  • PDF

A Design of Intellectual Air-conditioning System using by CFD (CFD를 이용한 지능형 객차 공기조화시스템 설계)

  • Bae Sang-Ho;Park Duck-Shin;Yang David;Park Tae-young
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.177-182
    • /
    • 2004
  • Railroad car is one of major public transportation because of an increase in population and heavy traffic problems. We design the concept with air filtration of HVAC system using CFD, select environment-friendly components and compose intellectual HVAC system. For this object, the research to connect HVAC system which control temperature, humidity, air flow with pollutant controlling system which can deal with particular dust, nasty smell. In case of train, fresh air should be provided continuously for pleasant environment of the cabin every season. The air will control outer dust, inner particular dust, $CO_2$ density by air conditioning, heating, humidity regulating, air filtering and ventilating. Ventilation system on passenger cars should be designed for the health and comfort of the passengers.

  • PDF

The Size-Oriented Particulate Mass Ratios and Their Characteristics on the Seoul Metropolitan Subway Lines

  • Lee, Eun-Sun;Lee, Tae-Jung;Park, Min-Bin;Park, Duckshin;Kim, Shin-Do;Kim, Dong-Sool
    • Asian Journal of Atmospheric Environment
    • /
    • v.10 no.4
    • /
    • pp.217-225
    • /
    • 2016
  • The purpose of the study was to initially investigate the concentration patterns of $PM_1$, $PM_{2.5}$ and $PM_{10}$ in the Seoul subway lines, and then to figure out the PM behaviors of internal and external sources inside subway tunnels. The PMs were monitored by a light scattering real-time monitor during winter (Jan. 8-26 in 2015) and summer (July 2-Aug. 7 in 2015) in tunnel air, in passenger cabin air, and in the ambient air. The daily average $PM_{10}$, $PM_{2.5}$, and $PM_1$ concentrations on these object lines were $101.3{\pm}38.4$, $81.5{\pm}30.2$, and $59.7{\pm}19.9{\mu}g/m^3$, respectively. On an average, the PM concentration was about 1.2 times higher in winter than in summer and about 1.5 times higher in underground tunnel sections than in ground sections. In this study, we also calculated extensively the average PM mass ratios for $PM_{2.5}/PM_{10}$, $PM_1/PM_{10}$, and $PM_1/PM_{2.5}$; for example, the range of $PM_{2.5}/PM_{10}$ ratio in tunnel air was 0.82-0.86 in underground tunnel air, while that was 0.48-0.68 in outdoor ground air. The ratio was much higher in tunnel air than in outdoor air and was always higher in summer than in winter in case of outdoor air. It seemed from the results that the in/out air quality as well as a proper amount of subway ventilation must be significant influence factors in terms of fine PM management and control for the tunnel air quality improvement.