• Title/Summary/Keyword: Radius Measurement

Search Result 297, Processing Time 0.03 seconds

A Study on the Detection of the Rain Using Open-Ended Coaxial Cavity Resonator (한쪽 면이 열린 동축 공동 공진기를 이용한 빗물 감지에 관한 연구)

  • Lee, Yun-Min;Kim, Jin-Kuk;Hur, Jung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.9
    • /
    • pp.944-950
    • /
    • 2013
  • This paper is a study of a rain sensor using an open-ended coaxial cavity resonator which senses the amount of rain drops linearly. It shows that it will be used as a sensor to sense the amount of rain dropped on the windshield of an automobile based on the principle of varied resonant frequency and the loss according to the amount and characteristics of an dielectric lied on the open side of a resonator. The input and output ports are built in the both sides of the resonator and the input and output coupling probes are formed like 'ㄱ' shape. The response of rain drops were simulated by the radius of inner conductor of 2 mm, 5 mm, and 10 mm respectively and it showed that the raindrop was sensed most linearly and sensitively when the radius of inner conductor is 5 mm, We have measured that the resonant frequency have varied from 3.55 GHz to 3 GHz and the Q value have varied from 42.38 to 24.3 according to the variation of rain drop amount on the fabricated resonator. Therefore, it shows that the designed resonator can be applied as a rain sensor that measures the amount of rain drops linearly by using the resonant frequency as a measurement parameter.

A study on the monitoring of high-density fine particulate matters using W-station: Case of Jeju island (W-Station을 활용한 고밀도 초미세먼지 모니터링 연구: 제주도 사례)

  • Lee, Jong-Won;Park, Moon-Soo;Won, Wan-Sik;Son, Seok-Woo
    • Particle and aerosol research
    • /
    • v.16 no.2
    • /
    • pp.31-47
    • /
    • 2020
  • Although interest in air quality has increased due to the frequent occurrence of high-concentration fine particulate matter recently, the official fine particulate matter measuring network has failed to provide spatial detailed air quality information. This is because current measurement equipment has a high cost of installation and maintenance, which limits the composition of the measuring network at high resolution. To compensate for the limitations of the current official measuring network, this study constructed a spatial high density measuring network using the fine particulate matter simple measuring device developed by Observer, W-Station. W-Station installed 48 units on Jeju Island and measured PM2.5 for six months. The data collected in W-Station were corrected by applying the first regression equation for each section, and these measurements were compared and analyzed based on the official measurements installed in Jeju Island. As a result, the time series of PM2.5 concentrations measured in W-Station showed concentration characteristics similar to those of the environmental pollution measuring network. In particular, the results of comparing the measurements of W-Station within a 2 km radius of the reference station and the reference station showed that the coefficient of determination (R2) was 0.79, 0.81, 0.67, respectively. In addition, for W-Station within a 1 km radius, the coefficient of determination was 0.85, 0.82, 0.68, respectively, showing slightly higher correlation. In addition, the local concentration deviation of some regions could be confirmed through 48 high density measuring networks. These results show that if a network of measurements is constructed with adequate spatial distribution using a number of simple meters with a certain degree of proven performance, the measurements are effective in monitoring local air quality and can be fully utilized to supplement or replace formal measurements.

Exposure Assessment for Toxic Hepatitis Caused by HCFC-123

  • Kim, Ki-Woong;Park, Hae Dong;Jang, Konghwa;Ro, Jiwon
    • Safety and Health at Work
    • /
    • v.9 no.3
    • /
    • pp.356-359
    • /
    • 2018
  • This case report attempts to present a case of acute toxic hepatitis in fire extinguisher manufacturing workers exposed to 2,2-dichloro-1,1,1-trifluoro-ethane (HCFC-123) in August 2017 in Korea. Twenty-two-year-old male workers were exposed to HCFC-123 for 1.5 hours one day and for 2.5 hours the other day, after which one worker died, and the other recovered after treatment. The workers were diagnosed with acute toxicity of hepatitis. However, exposure levels of HCFC-123 were not known with no work environment measurement done. Therefore, this study was conducted to estimate the exposure concentration of HCFC-123 via a job simulation experiment. In the simulation, the HCFC-123 exposure concentration was measured with the same working practice and working time as with the workers aforementioned. As a result, the workers who infused HCFC-123 into storage tanks were estimated to be exposed to HCFC-123 at a concentration of $20.65{\pm}10.81ppm$, and a mean concentration of area samples within a working radius were estimated as $70.30{\pm}18.10ppm$. Valve assembly workers working on valves of a fire extinguisher filled with HCFC-123 were exposed to HCFC-123 at concentrations of $91.65{\pm}4.03ppm$ and $115.55{\pm}7.28ppm$, respectively, in the simulation, and area samples simulated within the working radius were also found to be high with concentrations of $122.75{\pm}91.15ppm$ and $126.80{\pm}60.25ppm$, respectively. Nitrogen gas packing workers, who did not handle HCFC-123 directly, were exposed to the agent at a concentration of $71.80{\pm}8.49ppm$. These results suggest that exposure to HCFC-123 at high concentrations for 1.5-2.5 hours caused acute toxic hepatitis in two workers.

A Design and Implementation of Health Schedule Application

  • Ji Woo Kim;Young Min Lee;Won Joo Lee
    • Journal of the Korea Society of Computer and Information
    • /
    • v.29 no.3
    • /
    • pp.99-106
    • /
    • 2024
  • In this paper, we design and implement the HealthSchedule app, which records exercise data based on the GPS sensor embedded in smartphones. This app utilizes the smartphone's GPS sensor to collect real-time location information of the user and displays the movement path to the designated destination. It records the user's actual path using latitude and longitude coordinates. Users register exercise activities and destination points when scheduling, and initiate the exercise. When measuring the current location, a lime green departure marker is generated, and the movement path is displayed in blue, with the destination marker and a surrounding 25-meter radius circle shown in sky blue. Using the coordinates of the starting point or the previous location and the current GPS sensor-transmitted location coordinates, it measures the distance traveled, time taken, and calculates the speed. Furthermore, it accumulates measurement data to provide information on the total distance traveled, movement path, and overall average speed. Even when reaching the destination during exercise, the movement path continues to accumulate until the completion button is clicked. The completion button is activated when the user moves into the sky blue circular area with a radius of 25 meters, centered around the initially set destination. This means that the user must reach the designated destination, and if they wish to continue exercising without clicking the completion button, they can do so. Depending on the selected exercise type, the app displays the calories burned, aiming to increase user engagement and a sense of accomplishment.

Assessment of Wicking and Fast Dry Properties According to Moisture Transport Measurement Method of Knit and Woven Fabrics for Garment (의류소재용 직·편물의 수분이동 특성 측정 방법에 따른 흡한속건성 평가)

  • Kim, Hyun-ah;Kim, Seung-jin
    • Science of Emotion and Sensibility
    • /
    • v.20 no.2
    • /
    • pp.117-126
    • /
    • 2017
  • In this study, moisture transport characteristics for the woven and knitted fabrics made of 8 kinds of fiber materials using MMT (moisture management tester) were measured and discussed with the Bireck bt MMT and water evaporating rate (WER) measuring methods, which are vertical moisture transport methods. In addition, the drying property by MMT of the eight kinds of specimens was compared and discussed with the results measured by the vertical drying measurement. MMT experimental result which is horizental moisture transport appeared to be similar to the result of the Bireck method, which is the vertical moisture transport experiment. Absortion time measured from drip method of the fabrics made of the bamboo, linen, and cotton/nylon composite fabrics was short and thus they showed best wicking property, which was attributed to the low contact angle on the fabric surface and high porosity of the fabrics due to the staple yarn structure composed of the hydrophilic staple fibers. In drying property of the fabric specimens by MMT, maximum absorption radius of the dry-zone knit and bamboo woven fabrics were the highest and they showed the best drying property, which was a little different result compared with vertical drying measurement method. Half time of the drying rate in the MMT method was highly correlated with the fabric thickness and saturated moisture absortion rate and their regression coefficients were 0.9 and 0.88, respectively. This means that the knitted and woven fabric design technology for retaining good wicking and drying properties of the fabrics with thin fabric thickness is very important for obtaining high functional wear comfort fabrics. In addition, wicking and drying properties of the fabrics made of different fiber materials and with different yarns and fabric structures showed different results according to the measuring methods.

Measurement for the Tuning Circle of the Stern Trawler HAELIM-3 by the Differential GPS (DGPS에 의한 선미트롤선 해림 3호의 선회권측정)

  • Choi, Jae-Eun;Kim, Jin-Kun;Kim, Ki-Yun
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.31 no.1
    • /
    • pp.84-92
    • /
    • 1995
  • The methods by turning circle test and maneuvering indices have been used to study and evaluate the maneuverability of a ship. However recently many studies utilizing the GPS are made on the measurement of the turning circle and in the fishery and hydrographic survey. In this paper, the author carried out the turning circle test using the differential GPS and dumb card together, and compared the data measured by them and analyzed the accuracies of them to obtain the utility basic ones on the measurement of the turning circle by the DGPS. The main results area s follows : 1) To check the accuracies of the GPS, the circling experiments of 50m radius by the DGPS were made on the ground. The accuracies of turning circle measured by the DGPS were found to be very high as the errors of 1.5m. 2) the turning circle by the DGPS could be measured very accurately, by the seed, rudder angle, starboard and port respectively. 3) The turning circle measured by the dumb card was found to be measured accurately as much as the DGPS, when using large rudder angle, the turning circle was large, the turning circle by the dumb car could not be measured accurately on account of large error of bearing of compass. 4) The tactical diameters by the DGPS in case of the rudder angle 35。~5。, were found to be 2.6。15.0 times the Lpp of S.T HAELIM-3 at her slow speed 2.8~16.6 times her Lpp at her half speed, 3.1~17.4 times her Lpp at her full speed. The tactical diameter by the dumb card was found to be 2.4~9.5 times, 2.6~9.6 times, 3.2~12.2 times her Lpp respectively, in the above case and speed.

  • PDF

Development of Management Guidelines and Procedure for Anthropometric Suitability Assessment: Control Room Design Factors in Nuclear Power Plants

  • Lee, Kyung-Sun;Lee, Yong-Hee
    • Journal of the Ergonomics Society of Korea
    • /
    • v.34 no.1
    • /
    • pp.29-43
    • /
    • 2015
  • Objective: The aim of this study is to develop management guidelines and a procedure for an anthropometric suitability assessment of the main control room (MCR) in nuclear power plants (NPPs). Background: The condition of the MCR should be suitable for the work crews in NPPs. The suitability of the MCR depends closely on the anthropometric dimensions and ergonomic factors of the users. In particular, the MCR workspace design in NPPs is important due to the close relationship with operating crews and their work failures. Many documents and criteria have recommended that anthropometry dimensions and their studies are one of the foremost processes of the MCR design in NPPs. If these factors are not properly considered, users can feel burdened about their work and the human errors that might occur. Method: The procedure for the anthropometric suitability assessment consists of 5 phases: 1) selection of the anthropometric suitability evaluation dimensions, 2) establishment of a measurement method according to the evaluation dimensions, 3) establishment of criteria for suitability evaluation dimensions, 4) establishment of rating scale and improvement methods according to the evaluation dimensions, and 5) assessment of the final grade for evaluation dimensions. The management guidelines for an anthropometric suitability assessment were completed using 10 factors: 1) director, 2) subject, 3) evaluation period, 4) measurement method and criteria, 5) selection of equipment, 6) measurement and evaluation, 7) suitability evaluation, 8) data sharing, 9) data storage, and 10) management according to the suitability grade. Results: We propose a set of 17 anthropometric dimensions for the size, cognition/perception action/behavior, and their relationships with human errors regarding the MCR design variables through a case study. The 17 selected dimensions are height, sitting height, eye height from floor, eye height above seat, arm length, functional reach, extended functional reach, radius reach, visual field, peripheral perception, hyperopia/myopia/astigmatism, color blindness, auditory acuity, finger dexterity, hand function, body angle, and manual muscle test. We proposed criteria on these 17 anthropometric dimensions for a suitability evaluation and suggested an improvement method according to the evaluation dimensions. Conclusion: The results of this study can improve the human performance of the crew in an MCR. These management guidelines and a procedure for an anthropometric suitability assessment will be able to prevent human errors due to inadequate anthropometric dimensions. Application: The proposed set of anthropometric dimensions can be integrated into a managerial index for the anthropometric suitability of the operating crews for more careful countermeasures to human errors in NPPs.

Study on Dynamic Tip-over Analysis of Foldable Electric Wheelchair (접이식 전동휠체어의 동적 전도해석 연구)

  • Jang, Dae-Jin;Kim, Yong-Cheol;Kim, Shin-Ki;Mun, Mu-Sung;Park, Jong-Cheol
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.10 no.2
    • /
    • pp.133-139
    • /
    • 2016
  • An electric wheelchair is a assistive device to maneuver on the ground. Tip-over of an electric wheelchair is increasing every year. Dynamic stability metric test item in KS P 7176 has not ensured safety of electric wheelchair on the slope. This study presents design the foldable electric wheelchair that can load in the car and analysis of tip-over measurement which is easily computed for electric wheelchair. Wheelchair frame is designed with a four-bar link mechanism for a foldable structure, and seat module, battery and power driving module can be separated. This analysis is performed during a maneuver on the ground by force-moment stability metric. Several elements, center of gravity position, rotational radius and acceleration, were evaluated how to affect stability metric. This stability metric can reduce tip-over of wheelchair and provide a clue to make of dynamic stability test item.

Simultaneous Measurement of Thickness and Refractive Index of Transparent Material Using a Collimated Beam Having a Finite Radius (유한 반경의 시준 광속을 이용한 투명 매질의 두께와 굴절률의 동시 측정)

  • Park, Dae-Seo;O, Beom-Hoan;Park, Se-Geun;Lee, El-Hang;Lee, Seung-Gol
    • Korean Journal of Optics and Photonics
    • /
    • v.20 no.1
    • /
    • pp.29-33
    • /
    • 2009
  • We propose a new measuring technique based on optical low-coherence reflectometry that enables us to determine the refractive index and the geometrical thickness of a transparent sample by one-time scanning only. By passing a collimated beam having a finite size through the edge of the sample, the refractive index and the geometrical thickness can be determined simultaneously from the comparison of interferograms generated by two kinds of reflected beams. In this study, a refractive index could be determined with the accuracy of $10^{-3}$, and its accuracy would be enhanced by using a more precise translator and a thicker sample.

Uncertainty Analysis in Estimation of Roughness Coefficient Using the Field Measurement Data (현장실측에 의한 조도계수 산정의 불확실도 평가)

  • Kim, Ji-Sung;Lee, Chan-Joo;Kim, Won
    • Journal of Korea Water Resources Association
    • /
    • v.40 no.10
    • /
    • pp.801-810
    • /
    • 2007
  • In this study, validity and limitation of the estimation of roughness coefficient using the measured field data are investigated and the errors of the calculated roughness coefficient are analyzed. The assumption of uniform flow led to much difference of the computed results in low flow, and this is due to change of the cross-section informations such as flow area and hydraulic radius rather than the difference of velocity head. From the comparison between the estimations of average roughness coefficient in the reach which is relatively long, the calculation using the modified Newton-Raphson method is very efficient and accurate. In the measured roughness coefficient, the errors of measured flow and stage are included and the lower flow is, the larger the magnitude of error of measured roughness coefficient is. But the error of depth and velocity associated with uncertainty of roughness coefficient is less than about 5% in the both of low and high flow, and it shows the validity of measured roughness coefficient.