• Title/Summary/Keyword: Radiotherapy techniques

Search Result 117, Processing Time 0.03 seconds

Analysis of Automatic Rigid Image-Registration on Tomotherapy (토모테라피의 자동영상정합 분석)

  • Kim, Young-Lock;Cho, Kwang Hwan;Jung, Jae-Hong;Jung, Joo-Young;Lim, Kwang Chae;Kim, Yong Ho;Moon, Seong Kwon;Bae, Sun Hyun;Min, Chul Kee;Kim, Eun Seog;Yeo, Seung-Gu;Suh, Tae Suk;Choe, Bo-Young;Min, Jung-Whan;Ahn, Jae Ouk
    • Journal of radiological science and technology
    • /
    • v.37 no.1
    • /
    • pp.37-47
    • /
    • 2014
  • The purpose of this study was to analyze translational and rotational adjustments during automatic rigid image-registration by using different control parameters for a total of five groups on TomoTherapy (Accuray Inc, Sunnyvale, CA, USA). We selected a total of 50 patients and classified them in five groups (brain, head-and-neck, lung, abdomen and pelvic) and used a total of 500 megavoltage computed tomography (MVCT) image sets for the analysis. From this we calculated the overall mean value(M) for systematic and random errors after applying the different control parameters. After randomization of the patients into the five groups, we found that the overall mean value varied according to three techniques and resolutions. The deviation for the lung, abdomen and pelvic groups was approximately greater than the deviation for the brain and head-and-neck groups in all adjustments. Overall, using a "full-image" produces smaller deviations in the rotational adjustments. We found that rotational adjustment has deviations with distinctly different control parameters. We concluded that using a combination of the "full-image" technique and "standard" resolution will be helpful in assisting with patients' repositioning and in correcting for set-up errors prior to radiotherapy on TomoTherapy.

Development of an Automatic Seed Marker Registration Algorithm Using CT and kV X-ray Images (CT 영상 및 kV X선 영상을 이용한 자동 표지 맞춤 알고리듬 개발)

  • Cheong, Kwang-Ho;Cho, Byung-Chul;Kang, Sei-Kwon;Kim, Kyoung-Joo;Bae, Hoon-Sik;Suh, Tae-Suk
    • Radiation Oncology Journal
    • /
    • v.25 no.1
    • /
    • pp.54-61
    • /
    • 2007
  • [ $\underline{Purpose}$ ]: The purpose of this study is to develop a practical method for determining accurate marker positions for prostate cancer radiotherapy using CT images and kV x-ray images obtained from the use of the on- board imager (OBI). $\underline{Materials\;and\;Methods}$: Three gold seed markers were implanted into the reference position inside a prostate gland by a urologist. Multiple digital image processing techniques were used to determine seed marker position and the center-of-mass (COM) technique was employed to determine a representative reference seed marker position. A setup discrepancy can be estimated by comparing a computed $COM_{OBI}$ with the reference $COM_{CT}$. A proposed algorithm was applied to a seed phantom and to four prostate cancer patients with seed implants treated in our clinic. $\underline{Results}$: In the phantom study, the calculated $COM_{CT}$ and $COM_{OBI}$ agreed with $COM_{actual}$ within a millimeter. The algorithm also could localize each seed marker correctly and calculated $COM_{CT}$ and $COM_{OBI}$ for all CT and kV x-ray image sets, respectively. Discrepancies of setup errors between 2D-2D matching results using the OBI application and results using the proposed algorithm were less than one millimeter for each axis. The setup error of each patient was in the range of $0.1{\pm}2.7{\sim}1.8{\pm}6.6\;mm$ in the AP direction, $0.8{\pm}1.6{\sim}2.0{\pm}2.7\;mm$ in the SI direction and $-0.9{\pm}1.5{\sim}2.8{\pm}3.0\;mm$ in the lateral direction, even though the setup error was quite patient dependent. $\underline{Conclusion}$: As it took less than 10 seconds to evaluate a setup discrepancy, it can be helpful to reduce the setup correction time while minimizing subjective factors that may be user dependent. However, the on-line correction process should be integrated into the treatment machine control system for a more reliable procedure.

Suggestion for Comprehensive Quality Assurance of Medical Linear Accelerator in Korea (국내 선형가속기의 포괄적인 품질관리체계에 대한 제언)

  • Choi, Sang Hyoun;Park, Dong-wook;Kim, Kum Bae;Kim, Dong Wook;Lee, Jaiki;Shin, Dong Oh
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.294-303
    • /
    • 2015
  • American Association of Physicists in Medicine (AAPM) Published Task Group 40 report which includes recommendations for comprehensive quality assurance (QA) for medical linear accelerator in 1994 and TG-142 report for recommendation for QA which includes procedures such as intensity-modulated radiotherapy (IMRT), stereotactic radiosurgery (SRS) and stereotactic body radiation therapy (SBRT) in 2010. Recently, Nuclear Safety and Security Commission (NSSC) published NSSC notification no. 2015-005 which is "Technological standards for radiation safety of medical field". This notification regulate to establish guidelines for quality assurance which includes organization and job, devices, methods/frequency/tolerances and action levels for QA, and to implement quality assurance in each medical institution. For this reason, all of these facilities using medical machine for patient treatment should establish items, frequencies and tolerances for proper QA for medical treatment machine that use the techniques such as non-IMRT, IMRT and SRS/SBRT, and perform quality assurance. For domestic, however, there are lack of guidelines and reports of Korean Society of Medical Physicists (KSMP) for reference to establish systematic QA report in medical institutes. This report, therefore, suggested comprehensive quality assurance system such as the scheme of quality assurance system, which is considered for domestic conditions, based the notification of NSSC and AAPM TG-142 reports. We think that the quality assurance system suggested for medical linear accelerator also help establishing QA system for another high-precision radiation treatment machines.

Radiation Therapy of Nasopharyngeal Carcinoma (비인두강 종양의 방사선치료성적)

  • Nho Young Ju;Cho Jeong Gill;Ahn Seung Do;Choi Eun Kyung;Kim Jong Hoon;Kang One Chul;Chang Hyesook
    • Radiation Oncology Journal
    • /
    • v.15 no.4
    • /
    • pp.305-313
    • /
    • 1997
  • Purpose : This is a retrospective study to evaluate the results of radiation therapy and prognostic factors influencing the results in nasopharyngeal carcinoma. Materials and Methods: From October 1989 to May 1996. 56 Patients were treated for nasopharyngeal carcinoma at Department of Radiation On-cology. According to stage, patients were distributed as follows : stage I (2), II (13). II (11), IV (30). Twenty-eight patients were treated with radiation therapy only, 7 patients were treated with neoadiuvant chemotherapy followed by radiation therapy. Twenty-one Patients were treated with radiation therapy and weekly CDDP. After external beam radiotherapy of 60Gy, 46Patients received boost dose with intracavitary radiation and 9 Patients with 3D conformal therapy. One patient received boost dose with 2 dimensional Photon beam therapy. The tumor dose ranged from 69.4Gy to 86.2Gy with median dose of 74.4Gy. The follow-up Period ranged from 5 months to 92 months with a median of 34 months. Results : Forty-seven patients achieved complete response and 8 Patients showed partial response. One Patient showed minimal response. Patterns of failure were as follows : locoregional recurrence (8) and distant metastasis (18). Among these patients, 2 patients failed locoregionally and distantly. The sites of distant metastasis were bone (8), lung (8) and liver (4). Five years survival rate was $67.2\%$ and 5 years disease-free survival rate was $53.6\%$. KPS (P=0.005) and response ol radiation therapy (P=0.0001) were significant prognostic factors for overall survival. KPS (P= 0.02) and response of radiation therapy (P=0.005) were significant Prognostic factors for disease-free survival. Conclusion : This retrospective study showed that distant metastasis was the Predominant pattern of relapse in nasopharyngeal cancer Neoadiuvant chemotherapy or weekly CDOP did not influence the distant metastasis-free survival. For advanced T stage, 3D conformal therapy Provided an improved dose coverage compared to ICR But further follow-up was needed in Patients with 3D conformal therapy to assess the efficacy of this therapy. Development of techniques of radiation therapy to improve locoregional control and of more effective systemic chemotherapy regimen are needed.

  • PDF

Targeted Therapies and Radiation for the Treatment of Head and Neck Cancer (두경부 암의 표적 지향적 방사선 치료)

  • Kim, Gwi-Eon
    • Radiation Oncology Journal
    • /
    • v.22 no.2
    • /
    • pp.77-90
    • /
    • 2004
  • Purpose: The purpose of this review Is to provide an update on novel radiation treatments for head and neck cancer Recent Findings: Despite the remarkable advances In chemotherapy and radiotherapy techniques, the management of advanced head and neck cancer remains challenging. Epidermal growth factor receptor (EGFR) Is an appealing target for novel therapies In head and neck cancer because not only EGFR activation stimulates many important signaling pathways associated with cancer development and progression, and importantly, resistance to radiation. Furthermore, EGFR overexpression Is known to be portended for a worse outcome in patients with advanced head and neck cancer. Two categories of compounds designed to abrogate EGFR signaling, such as monoclonal antibodies (Cetuxlmab) and tyrosine kinase inhibitors (ZD1839 and 051-774) have been assessed and have been most extensively studied In preclinical models and clinical trials. Additional TKIs In clinical trials include a reversible agent, Cl-1033, which blocks activation of all erbB receptors. Encouraging preclinical data for head and neck cancers resulted In rapid translation Into the clinic. Results from Initial clinical trials show rather surprisingly that only minority of patients benefited from EGFR inhibition as monotherapy or In combination with chemotherapy. In this review, we begin with a brief summary of erbB- mediated signal transduction. Subsequently, we present data on prognostic-predictive value of erbB receptor expression in HNC followed by preclinlcal and clinical data on the role of EGFR antagonists alone or in combination with radiation In the treatment of HNC. Finally, we discuss the emerging thoughts on resistance to EGFR biockade and efforts In the development of multiple-targeted therapy for combination with chemotherapy or radiation. Current challenges for investigators are to determine (1 ) who will benefit from targeted agents and which agents are most appropriate to combine with radiation and/or chemotherapy, (2) how to sequence these agents with radiation and/or cytotoxlc compounds, (3) reliable markers for patient selection and verification of effective blockade of signaling in vivo, and (4) mechanisms behind intrinsic or acquired resistance to targeted agents to facilitate rational development of multi-targeted therapy, Other molecuiar-targeted approaches In head and neck cancer were briefly described, Including angloenesis Inhibitors, farnesyl transferase inhibitors, cell cycle regulators, and gene therapy Summary: Novel targeted theraples are highly appealing in advanced head and neck cancer, and the most premising strategy to use them Is a matter of intense Investigation.

The dosimetric guide of treatment modalities for Left side breast irradiation after conservative surgery (좌측 유방암 방사선 치료 시 치료 기법에 따른 선량적 고찰)

  • Kim, Tae Min;Moon, Sung Kong;Kim, Li Zzy;Kim, Se Young;Park, Ryeung Hwang;Kim, Joo Ho;Cho, Jung Heui
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.153-160
    • /
    • 2018
  • Purpose : We retrospectively analyzed doses of each radiation therapy technique used in the treatment for left breast cancer patients after partial mastectomy through dose results for normalorgans and tumor volume to use this as a clinical reference for radiation therapy of domestic left breast cancer patients. Materials and Methods : 40 patients who underwent partial mastectomy on left breast cancer were classified in 3 treatment methods. The treatment plan was evaluated by HI(homogeneity index), $D_{95%}$, and CI(conformity index), and the $V_{hot}$ for gross tumor volume and clinical target volume of each treatment method. In Cyberknife treatment, tumor volume was the same as high dose volume in the other techniques, so no consideration was given to clinical target volume. Treatment plan evaluation for normal organs were evaluated by mean dose on ipsilateral lung, heart, left anterior descending artery, opposite breast and lung, and non-target tissue. Result : Treatment with volumetric arc radiotherapy(VMAT) showed $95.84{\pm}0.75%$ of $D_{95%}$ on the clinical target volume, significantly higher than that of 3D-CRT. The $D_{95%}$ value of the total tumor volume was slightly higher than the other treatments. In Cyberknife treatment, the dose to the normal organs was significantly lower than other treatments. Overall, the maximum dose and mean dose to the heart were $26.2{\pm}6.12Gy$ and $1.88{\pm}0.2Gy$ in VMAT treatment and $20.25{\pm}9.35Gy$ and $1.04{\pm}0.19Gy$ in 3D-CRT therapy, respectively. Conclusion : In comparison on 3D-CRT and VMAT, most of the dosimetric parameters for the evaluation of the treatment plan showed similar values, so that there is no significant difference in treatment plan evaluation. It is possible to select the treatment method according to the patient's anatomical structure or possibility of breath control. Cyberknife treatment is very useful treatment for normal organs because of its accurate dose exposure to the tumor volume However, it has restrictions to treat the local area, to have relatively long treatment time and to involve invasive procedure.

  • PDF

Surgery Alone and Surgery Plus Postoperative Radiation Therapy for Patients with pT3N0 Non-small Cell Lung Cancer Invading the Chest Wall (흉벽을 침범한 pT3N0 비소세포폐암 환자에서 수술 단독과 수술 후 방사선치료)

  • 박영제;임도훈;김관민;김진국;심영목;안용찬
    • Journal of Chest Surgery
    • /
    • v.37 no.10
    • /
    • pp.845-855
    • /
    • 2004
  • Background: No general consensus has been available regarding the necessity of postoperative radiation therapy (PORT) and its optimal techniques in the patients with chest wall invasion (pT3cw) and node negative (N0) non-small cell lung cancer (NSCLC). We did retrospective analyses on the pT3cwN0 NSCLC patients who received PORT because of presumed inadequate resection margin on surgical findings. And we compared them with the pT3cwN0 NSCLC patients who did not received PORT during the same period. Material and Method: From Aug. of 1994 till June of 2002, 22 pT3cwN0 NSCLC patients received PORT-PORT (+) group- and 16 pT3cwN0 NSCLC patients had no PORT-PORT (-) group. The radiation target volume for PORT (+) group was confined to the tumor bed plus the immediate adjacent tissue only, and no regional lymphatics were included. The prognostic factors for all patients were analyzed and survival rates, failure patterns were compared with two groups. Result: Age, tumor size, depth of chest wall invasion, postoperative mobidities were greater in PORT (-) group than PORT (+) group. In PORT (-) group, four patients who were consulted for PORT did not receive the PORT because of self refusal (3 patients) and delay in the wound repair (1 patient). For all patients, overall survival (OS), disease-free survival (DFS), loco-regional recurrence-free survival (LRFS), and distant metastases-free survival (DMFS) rates at 5 years were 35.3%, 30.3%, 80.9%, 36.3%. In univariate and multivariate analysis, only PORT significantly affect the survival. The 5 year as rates were 43.3% in the PORT (+) group and 25.0% in PORT (-) group (p=0.03). DFS, LRFS, DMFS rates were 36.9%, 84.9%, 43.1 % in PORT (+) group and 18.8%, 79.4%, 21.9% in PORT(-) group respectively. Three patients in PORT (-) group died of intercurrent disease without the evidence of recurrence. Few suffered from acute and late radiation side effects, all of which were RTOG grade 2 or lower. Conclusion: The strategy of adding PORT to surgery to improve the probability not only of local control but also of survival could be justified, considering that local control was the most important component in the successful treatment of pT3cw NSCLC patients, especially when the resection margin was not adequate. Authors were successful in the marked reduction of the incidence as well as the severity of the acute and late side effects of PORT, without taking too high risk of the regional failures by eliminating the regional lymphatics from the radiation target volume.