• 제목/요약/키워드: Radionuclide Imaging

검색결과 89건 처리시간 0.039초

Missed Skeletal Trauma Detected by Whole Body Bone Scan in Patients with Traumatic Brain Injury

  • Seo, Yongsik;Whang, Kum;Pyen, Jinsu;Choi, Jongwook;Kim, Joneyeon;Oh, Jiwoong
    • Journal of Korean Neurosurgical Society
    • /
    • 제63권5호
    • /
    • pp.649-656
    • /
    • 2020
  • Objective : Unclear mental state is one of the major factors contributing to diagnostic failure of occult skeletal trauma in patients with traumatic brain injury (TBI). The aim of this study was to evaluate the overlooked co-occurring skeletal trauma through whole body bone scan (WBBS) in TBI. Methods : A retrospective study of 547 TBI patients admitted between 2015 and 2017 was performed to investigate their cooccurring skeletal injuries detected by WBBS. The patients were divided into three groups based on the timing of suspecting skeletal trauma confirmed : 1) before WBBS (pre-WBBS); 2) after the routine WBBS (post-WBBS) with good mental state and no initial musculoskeletal complaints; and 3) after the routine WBBS with poor mental state (poor MS). The skeletal trauma detected by WBBS was classified into six skeletal categories : spine, upper and lower extremities, pelvis, chest wall, and clavicles. The skeletal injuries identified by WBBS were confirmed to be simple contusion or fractures by other imaging modalities such as X-ray or computed tomography (CT) scans. Of the six categorizations of skeletal trauma detected as hot uptake lesions in WBBS, the lesions of spine, upper and lower extremities were further statistically analyzed to calculate the incidence rates of actual fractures (AF) and actual surgery (AS) cases over the total number of hot uptake lesions in WBBS. Results : Of 547 patients with TBI, 112 patients (20.4 %) were presented with TBI alone. Four hundred and thirty-five patients with TBI had co-occurring skeletal injuries confirmed by WBBS. The incidences were as follows : chest wall (27.4%), spine (22.9%), lower extremities (20.2%), upper extremities (13.5%), pelvis (9.4%), and clavicles (6.3%). It is notable that relatively larger number of positive hot uptakes were observed in the groups of post-WBBS and poor MS. The percentage of post-WBBS group over the total hot uptake lesions in upper and lower extremities, and spines were 51.0%, 43.8%, and 41.7%, respectively, while their percentages of AS were 2.73%, 1.1%, and 0%, respectively. The percentages of poor MS group in the upper and lower extremities, and spines were 10.4%, 17.4%, and 7.8%, respectively, while their percentages of AS were 26.7%, 14.2%, and 11.1%, respectively. There was a statistical difference in the percentage of AS between the groups of post-WBBS and poor MS (p=0.000). Conclusion : WBBS is a potential diagnostic tool in understanding the skeletal conditions of patients with head injuries which may be undetected during the initial assessment.

Clinical Features of Symptomatic Meckel's Diverticulum in Children: Comparison of Scintigraphic and Non-scintigraphic Diagnosis

  • Rho, Jung Hee;Kim, Jae Sook;Kim, Sang Yong;Kim, Soon Ki;Choi, Yoon Mi;Kim, Sung Min;Tchah, Hann;Jeon, In Sang;Son, Dong Woo;Ryoo, Eell;Cho, Kang Ho;Choi, Deok Young;Kim, Yoon Mi
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • 제16권1호
    • /
    • pp.41-48
    • /
    • 2013
  • Purpose: Meckel's diverticulum (MD) has various clinical manifestations, and diagnosis or selectection of proper diagnostic tools is not easy. This study was conducted in order to assess the clinical differences of MD diagnosed by scintigraphic and non-scintigraphic methods and to find the proper diagnostic tools. Methods: We conducted a retrospective review ofthe clinical, surgical, radiologic, and pathologic findings of 34 children with symptomatic MD, who were admitted to Gachon University Gil Medical Center, Inha University Hospital, and The Catholic University of Korea, Incheon St. Mary's Hospital between January 2000 and December 2012. The patients were evaluated according to scintigraphic (12 cases; group 1) and non-scintigraphic (22 cases; group 2) diagnosis. Results: The male to female ratio was 7.5: 1. The most frequent chief complaint was lower gastrointestinal (GI) bleeding in group 1 and nonspecific abdominal pain in group 2, respectively. The most frequent pre-operative diagnosis was MD in both groups. Red blood cell (RBC) index was significantly lower in group 1. MD was located at 7 cm to 85 cm from the ileocecal valve. Four patients in group 1 had ectopic gastric tissues causing lower GI bleeding. The most frequent treatment modality was diverticulectomy in group 1 and ileal resection in group 2, respectively. Conclusion: To diagnose MD might be delayed unless proper diagnostic tools are considered. It is important to understand indications of scintigraphic and non-scintigraphic methods according to clinical and hematologic features of MD. Scintigraphy would be weighed in patients with anemia as well as GI symptoms.

In vivo comparison of Lu-177-labeled phosphonate compounds as potential agents for bone pain palliation in rodents

  • Chang, Young Soo;Lee, Yun-Sang;Kim, Young Ju;Jeong, Jae Min
    • 대한방사성의약품학회지
    • /
    • 제1권1호
    • /
    • pp.53-61
    • /
    • 2015
  • Lutetium-177 ($T_{1/2}=6.71day$) is an adequate radionuclide for therapy, which has both beta emission ($E_{max}=497keV$) for therapeutic effect and gamma emission (113 and 208 keV) for imaging. $^{177}Lu$ labeled ethylenediamine-N,N,N',N'-tetrakis (methylene phosphonic acid) (EDTMP) and 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraaminomethylenephosphonate (DOTMP) have been proposed as radiopharmaceuticals for bone pain palliation. In this study, we compared radiochemistry and biodistribution of $^{177}Lu$-EDTMP and $^{177}Lu$-DOTMP. EDTMP and DOTMP were synthesized, and 1 mg of each was labeled with $^{177}Lu$ at pH 7~8 with high efficiency (>98%). For comparative biodistribution studies, $^{177}Lu$-EDTMP or $^{177}Lu$-DOTMP were injected into ICR-mice through tail vein, and then biodistribution data were obtained as percentages of injected dose per gram of tissue (% ID/g). Urine excretions of both agents in mice were checked for 7 days. Rat images were also obtained after injection of $^{177}Lu$-EDTMP or $^{177}Lu$-DOTMP. $^{177}Lu$-DOTMP (100% at 1 min) showed faster labeling than $^{177}Lu$-EDTMP (100% at 30 min). Both of them were stable at least for 21 days at room temperature. High bone uptakes were found for both $^{177}Lu$-EDTMP and $^{177}Lu$-DOTMP: 38.0 and 34.1% ID/g at 3 hr, respectively; and 33.2 and 18.8% ID/g at 7 day, respectively. Rapid excretions to urine were found for both agents ($^{177}Lu$-EDTMP: 56%, $^{177}Lu$-DOTMP: 63% at 1 day). Other organs showed very low uptakes. Rat images of both $^{177}Lu$-EDTMP and $^{177}Lu$-DOTMP showed high bone uptakes and low soft tissue uptakes. In conclusion, both $^{177}Lu$-EDTMP and $^{177}Lu$-DOTMP showed high potential as bone pain palliation agents. $^{177}Lu$-EDTMP showed higher bone uptake and slower bone clearance in mice than those of $^{177}Lu$-DOTMP.

Gated Cardiac Blood Pool scan에서의 심장 주위 배후방사능 관심영역 설정시 산란선의 영향을 감소시키기 위한 연구 (Study a Technique for Reducing the Influence of Scattered Rays from Surrounding Organs to the Heart during Gated Cardiac Blood Pool scan)

  • 김정열;박훈희;남궁혁;조석원;김재삼;이창호
    • 핵의학기술
    • /
    • 제12권1호
    • /
    • pp.33-38
    • /
    • 2008
  • Purpose: The Gated cardiac blood pool scan is non-invasive method that a quantitative evaluation of left ventricular function. Also this scan have shown the value of radionuclide ejection fraction measurements during the course of chemotherapy as a predictor of cardiac toxicity. Therefore a reliable method of monitoring its cardiotoxic effects is necessary. the purpose of this study is to minimize the overestimate of left ventricular ejection fraction (LVEF) by modified body position to reduce the influence of scattered rays from surrounding organs of the heart in the background region of interest. Materials and Methods: Gated cardiac blood pool scan using in vivo $^{99m}Tc$-red blood cell (RBC) was carried out in 20 patients (mean $44.8{\pm}8.6$ yr) with chemotherapy for a breast carcinoma. Data acquisition requires about 600 seconds and 24 frames of one heart cycle by the multigated acquisition mode, Synchronization deteriorates toward the end of the cycle and with the distance from the trigger signal (R-wave) by ECG gating. Gated cardiac blood pool scan was studied with conventional method (supine position and the detector head in $30-45^{\circ}$ left anterior oblique position and caudal $10-20^{\circ}$ tilt) and compared with modified method (left lateral flexion position with 360 mL of drinking water). LVEF analysis was performed by using the automatically computer mode. Results: The ROI counts of modified scan method were lower than LV conventional method ($1429{\pm}251$ versus $1853{\pm}243$, <0.01). And LVEF of modified method was also decrease compared with conventional method ($58.3{\pm}5.6%$ versus $65.3{\pm}6.1%$, <0.01). Imaging analysis indicated that stomach was expanded because of water and spleen position was changed to lateral inferior compared with conventional method. Conclusion: This study shows that the modified method in MUGA reduce the influence of scattered rays from surrounding organs. Because after change the body position to left lateral flexion and drinking water, the location of spleen, left lobe of liver and stomach had changed and they could escaped from background ROI. Therefore, modified method could help to minimize the overestimate LVEF (%).

  • PDF

방사성동위원소표지 Liposome의 분포에 대한 실험적 연구 (Distribution of Radionuclide Labeled Liposome in Experimental Study)

  • 이범우;정재민;김상은;이동수;정준기;이명철;고창순;하성환
    • 대한핵의학회지
    • /
    • 제24권2호
    • /
    • pp.317-324
    • /
    • 1990
  • Liposome was labelled with $^{99m}Tc$ after negative charged liposome was formed with combination of a few lipid components. $^{99m}Tc$ liposome was injected through the tail vein of C3H mice bearing fibrosarcoma and biodistribution of $^{99m}Tc$ liposome was evaluated. The results were as follows: 1) We confirmed formation of liposome which was small unillamellar and multilamellar vesicles. 2) In this experiment the optimal concentration of $SnCl_2$ was $156{\mu}g/ml$ to label liposome with $^{99m}Tc$ and labelling efficiency was 95%. 3) The labelled liposome was stable when it was incubated with human serum for 24 hours. Mean labelling efficiency was 94% at 24 hour. 4) The main uptake sites of Tc-99m liposome were liver and spleen. It showed significantly higher uptake than $^{99m}Tc$ HSA (p < 0.001). 5) $^{99m}Tc$ liposome uptake in tumor tissue was not significantly higher than $^{99m}Tc$ HSA uptake. In conclusion, $^{99m}Tc$ liposome disclosed high labelling efficiency and was highly stable. Liver and spleen were main uptake sites of $^{99m}Tc$ liposome. The uptake mechanism of $^{99m}Tc$ liposome also seemed to be different from that of $^{99m}Tc$ HSA. We conclude that $^{99m}Tc$ liposome would be a promising agents for the imaging of some tumor.

  • PDF

규폐증에서 Gallium-67 신티그라피의 정량적인 분석: 흉부 X-선과 폐기능검사와의 비교 (Quantitative Ga-67 Scintigraphy in patients with Silicosis: Comparison with Chest X-ray and Pulmonary Function)

  • 신광현;손형선;정용안
    • 대한핵의학회지
    • /
    • 제33권4호
    • /
    • pp.381-387
    • /
    • 1999
  • 목적: 직업성 질병은 원인 규명과 함께 병의 진행정도를 정확히 평가하는 것이 중요하여 ILO에서 흉부 X-선 소견을 기준으로 국제표준화를 시행하여 왔으나 사진의 질에 영향을 받을 수 있고, 초기 병변을 발견하기에는 어려움이 많다. 본 연구자들은 Ga-67의 섭취정도를 규폐증의 진행 정도를 나타내는 지표로 이용하기 위하여 폐기능검사 및 흉부 X-선 소견에 의한 임상적 병기 분류와의 상관관계를 보고자하였다. 대상 및 방법: 25명의 규폐증 환자를 대상으로 Ga-67 신티그라피를 분석하였으며 10명의 정상인을 대조군으로 하였다. 검사방법은 Ga-67 citrate, 5 mCi를 정맥 주사한 후 48시간 후 전신 스캔 및 흉부, 복부 스캔 영상을 얻어 후면상에서 간과 폐병변의 최대 섭취 부위의 관심영역을 설정하여 픽셀당 방사능 섭취 정도의 비를 구하여 임상적 병기 분류와의 상관관계를 비교 분석하였다. 결과: L/L Ratio 값은 정상군 0형(n=10): $0.3948{\pm}.0692$0, 1형(n=10): $0.5763{\pm}$0.1837, 2형(n= 11): $0.6849{\pm}0.1459$, 3형(n=4): $0.9913{\pm}0.0712$였으며 흉부 X-선의 분류형과 서로 유의한 상관관계를 보였다(r=0.618, p<0.05). 그러나 L/L Ratio 값과 폐기능검사 지표와는 통계적으로 유의하지 않았다. 결론: 저자들의 연구에 따르면 규폐증의 진행과정을 평가하여 환자의 병기를 결정하는 데 Ga-67 신티그라피의 정량적인 분석이 도움을 주었다. 그러나 폐기능과는 상관관계가 없어 폐기능을 평가하는 지표가 되지 못하였다.

  • PDF

Impact of piezocision on orthodontic tooth movement

  • Papadopoulos, Nikolaos;Beindorff, Nicola;Hoffmann, Stefan;Jost-Brinkmann, Paul-Georg;Prager, Thomas Michael
    • 대한치과교정학회지
    • /
    • 제51권6호
    • /
    • pp.366-374
    • /
    • 2021
  • Objective: This study investigated the impact of a single piezocision in the maxillary alveolar process on the speed of tooth movement. The null hypothesis was that the speed of tooth movement will be equal with and without piezocision. Methods: All maxillary molars on one side were moved against the combined incisors in 10 ten-week-old male Wistar rats. Under general anesthesia, a force of 25 cN was applied on either side using a Sentalloy closed coil spring. After placing the orthodontic appliance, vertical corticision was performed using a piezotome under local anesthesia, 2 mm mesial from the mesial root of the first molar on a randomly selected side; the other side served as the control. At the beginning of the treatment, and 2 and 4 weeks later, skull micro-computed tomography was performed. After image reconstruction, the distance between the mesial root of the first molar and the incisive canal, and the length of the mesial root of the first maxillary molar were measured. Moreover, the root resorption score was determined as described by Lu et al. Results: Significantly higher speed of tooth movement was observed on the corticision side; thus, the null hypothesis was rejected. The loss of root length and root resorption score were significantly more pronounced after piezocision than before. A strong correlation was observed between the speed of tooth movement and root resorption on the surgical side, but the control side only showed a weak correlation. Conclusions: Piezocision accelerates orthodontic tooth movement and causes increased root resorption.

PET 이용 현황 및 전망 (Current Status and Future Perspective of PET)

  • 이명철
    • 대한핵의학회지
    • /
    • 제36권1호
    • /
    • pp.1-7
    • /
    • 2002
  • Positron Emission Tomography (PET) is a nuclear medicine imaging modality that consists of systemic administration to a subject of a radiopharmaceutical labeled with a positron-emitting radionuclide. Following administration, its distribution in the organ or structure under study can be assessed as a function of time and space by (1) defecting the annihilation radiation resulting from the interaction of the positrons with matter, and (2) reconstructing the distribution of the radioactivity from a series of that used in computed tomography (CT). The nuclides most generally exhibit chemical properties that render them particularly desirable in physiological studies. The radionuclides most widely used in PET are F-18, C-11, O-15 and N-13. Regarding to the number of the current PET Centers worldwide (based on ICP data), more than 300 PET Centers were in operation in 2000. The use of PET technology grew rapidly compared to that in 1992 and 1996, particularly in the USA, which demonstrates a three-fold rise in PET installations. In 2001, 194 PET Centers were operating in the USA. In 1994, two clinical and research-oriented PET Centers at Seoul National University Hospital and Samsung Medical Center, was established as the first dedicated PET and Cyclotron machines in Korea, followed by two more PET facilities at the Korea Cancer Center Hospital, Ajou Medical Center, Yonsei University Medical Center, National Cancer Center and established their PET Center. Catholic Medical School and Pusan National University Hospital have finalized a plan to install PET machine in 2002, which results in total of nine PET Centers in Korea. Considering annual trends of PET application in four major PET centers in Korea in Asan Medical Center recent six years (from 1995 to 2000), a total of 11,564 patients have been studied every year and the number of PET studies has shown steep growth year upon year. We had 1,020 PET patients in 1995. This number increased to 1,196, 1,756, 2,379, 3,015 and 4,414 in 1996,1997,1998,1999 and 2000, respectively. The application in cardiac disorders is minimal, and among various neuropsychiatric diseases, patients with epilepsy or dementia can benefit from PET studios. Recently, we investigated brain mapping and neuroreceptor works. PET is not a key application for evaluation of the cardiac patients in Korea because of the relatively low incidence of cardiac disease and less costly procedures such as SPECT can now be performed. The changes in the application of PET studios indicate that, initially, brain PET occupied almost 60% in 1995, followed by a gradual decrease in brain application. However, overall PET use in the diagnosis and management of patients with cancer was up to 63% in 2000. The current medicare coverage policy in the USA is very important because reimbursement policy is critical for the promotion of PET. In May 1995, the Health Care Financing Administration (HCFA) began covering the PET perfusion study using Rubidium-82, evaluation of a solitary pulmonary nodule and pathologically proven non-small cell lung cancer. As of July 1999, Medicare's coverage policy expanded to include additional indications: evaluation of recurrent colorectal cancer with a rising CEA level, staging of lymphoma and detection of recurrent or metastatic melanoma. In December of 2001, National Coverage decided to expand Medicare reimbursement for broad use in 6 cancers: lung, colorecctal, lymphoma, melanoma, head and neck, and esophageal cancers; for determining revascularization in heart diseases; and for identifying epilepsy patients. In addition, PET coverage is expected to further expand to diseases affecting women, such as breast, ovarian, uterine and vaginal cancers as well as diseases like prostate cancer and Alzheimer's disease.

소아의 낭포성 신질환에 대한 임상적 고찰 (Clinical Study of Renal Cystic Diseases in Children)

  • 김자형;김유정;이병선;고태성;박영서
    • Clinical and Experimental Pediatrics
    • /
    • 제45권2호
    • /
    • pp.232-239
    • /
    • 2002
  • 목 적 : 낭포성 신질환은 다양한 원인, 증상, 예후를 나타내며 최근 들어 영상 진단의 발전으로 조기 진단이 가능해지면서 병인, 유전, 자연 경과 등에 대한 연구가 활발히 진행되고 있다. 본 연구에서는 낭포성 신질환 환아들을 대상으로 그 빈도, 임상양상, 동반기형, 치료 및 예후 등을 분석하여 향후 진단 및 치료에 도움이 되고자 하였다. 방 법 : 1989년 10월부터 2001년 6월까지 15세 이하의 낭포성 신질환 환아 95례를 대상으로 후향적 고찰을 시행하였다. 산전 초음파로 발견된 경우 출생 후 초음파를 다시 시행하여 진단하였으며 질환에 따라 DMSA, DTPA, MAG-3 신스캔, 배뇨성 방광 요도 조영술, 전산화 단층 촬영, 자기 공명 영상 등을 시행하였다. 결 과 : 1) 대상 환아는 총 95례였고, 추적 관찰 기간은 1개월에서 8년 4개월이었다. 다낭포성 신이형성증이 55례(58.5%)로 가장 많았고, 단순 낭포신은 19례(20.2%)였으며, 그중 단일 신낭포가 15례(13.8%). 다낭포가 4례(4.2%)였다. 유전성 다낭포신은 13례(13.7%)였고, 그중 상염색체 열성 다낭포신이 7례(7.4%), 상염색체 우성 다낭포신이 5례(5.3%)였다. 수질 낭성 질환은 1례(1.0%)였고, 결절성 경화증과 동반된 신낭포는 6례(6.3%)였다. 2) 진단은 다낭포성 신이형성증의 경우 총 55례 중에서 산전 초음파로 진단된 경우가 49례(89.0%)로 가장 많았으며, 단순 신낭포는 비특이적인 증상으로 방문하여 검사 도중 우연히 발견된 경우가 18례(94.7%)로 가장 많았다. 유전성 다낭포신 환아는 산전 초음파로 진단된 경우가 5례(38.5%), 복부 종괴에 대한 검사로 발견한 경우가 3례(23.0%), 복통이나 야뇨증 등의 비특이적인 증상으로 검사 중 우연히 발견된 경우가 2례(15.4%), 혈뇨에 대한 검사 중 발견한 경우가 2례(15.4%), 가족력이 있어 발견된 1례(7.7%)가 있었다. 결절성 경화증 환아의 경우는 동반 질환 유무를 알기 위해 시행한 복부 초음파에서 신낭포가 발견되었다. 3) 동반된 요로계 기형 및 질환은 다낭포성 신이형성증 환아들의 경우 반대측 신장의 방광 요관 역류가 9례(16%)로 가장 많았으며 비뇨기계 이외의 동반기형으로는 심장 기형이 5례로 가장 흔했다. 상염색체 열성 다낭포신의 경우 방광 요관 역류, 췌장 낭포가 동반된 경우가 각각 1례가 있었고, 단순 신낭포는 2례에서 난소 낭포가 관찰되었다. 4) 임상 경과로 다낭포성 신이형성증의 경우는 추적 관찰 기간 중에 모두 합병증은 없었다. 유전성 다낭포신 질환 13례 중 상염색체 우성 다낭포신 환아 2례가 각각 6세, 8세에 말기 신부전으로 진행하였고, 상염색체 열성 다낭포신 환아 1례는 생후 5개월에 말기 신부전으로 진행하였다. 단순 신낭포의 경우 요관 신우 연결 부위 폐쇄 및 신우 압박이 관찰된 1례에서 복강경을 통한 malsupialization을 시행하였고, 1례의 수질 낭성 질환 환아는 진단 당시 이미 말기 신부전으로 진행되어 있어 신이식을 받았다. 결 론 : 낭포성 신질환은 여러 가지 임상 및 병리적인 소견을 보이며, 무증상으로 지내다가 우연히 발견되어 치료가 필요 없이 경과 관찰만 필요한 질환부터 신생아기부터 신부전으로 진행되거나, 비뇨기계 뿐만 아니라 비뇨기계 이외의 기형도 동반하는 질환까지 그 양상이 다양하다. 그러므로, 각 질환 별로 발생할 수 있는 고혈압, 신부전, 감염 등의 합병증을 적절히 치료하기 위해서는 조기 발견, 정확한 진단, 정기적인 추적 관찰이 중요할 것으로 판단된다.

섬유성 이형성증의 바늘구멍 골스캔 소견 (Pinhole Bone Scintigraphic Manifestation of Fibrous Dysplasia)

  • 백지희;이성용;김성훈;정용안;김범수;송하헌;정수교;강시원;박용휘;신경섭
    • 대한핵의학회지
    • /
    • 제31권4호
    • /
    • pp.452-458
    • /
    • 1997
  • 저자들은 섬유성 이형성증으로 진단받은 14명 환자의 16병변에서 단순 X-선사진의 소견에 따른 부위별 방사능 집적 정도를 알아보고 그 의의를 평가하기 위해 바늘구멍 골스캔과 단순 X-선사진 소견을 후향적으로 분석하여 비교하여 보았다. 10병변은 수술하여 조직학적으로 확진되었고, 6병변은 방사선학적으로 진단 받았다. 평균연령은 41.1세이며, 두 검사간의 간격은 평균 1.1일이었다. 병소의 위치는 늑골 7예, 골반골 4예, 쇄골 1예, 대퇴골 2예, 장골 1예, 상완골 1예였다. 바늘구멍골스캔 소견상 중심부에서 1+로 정상 방사능 집적을 보인예는 6예(방사선투과성 병변 5예, 간유리모양 병변 1예)이고, 2+로 중등도로 증가된 방사능 집적을 보인 경우는 7예(방사선투과성 병변 4예, 간유리모양 병변 3예)이며 3+로 현저히 증가된 경우는 3예(간유리모양 병변 1예, 경화성 병변 2예)가 있었다. 16예 중 15예에서 주변부 병소에 한 군데 이상의 증가된 방사능 집적이 불규칙한 환상이나 결절모양으로 나타났는데, 2+의 중등도 방사능 집적이 경화성테두리 5예와 비가시성 피질 1예에서, 그리고 3+의 현저한 방사능 집적증가는 격막과 피질천공을 보인 모든 예(7예, 8예)에서, 그리고 비가시성 피질 9예 중 8예에서 나타났다. 16예 중 1예는 중심부와 주변부 병소가 균일한 2+의 집적증가를 보였다. 바늘구멍 골스캔상 섬유성 이형성증의 방사선투과성병변은 이제까지 보고된 것과는 다르게 많은 예에서 인접 정상골과 비슷한 집적을 보였다. 또한, 격막, 피질골절 또는 비가시성 피질 등의 소견을 보이는 부분에 방사능 집적이 현저히 증가되어 주변부의 불규칙한 환상 또는 결절모양의 방사능 집적형태를 보였으며, 이들 병소는 골대사가 활발한 부위로 생각된다. 이와 같은 골의 섬유성 이형성증의 바늘구멍 골스캔 소견을 분석함으로써 부위별 활성도를 평가하여 진단, 예후 추정 및 치료방침을 결정하는데 유용하리라 사료된다.

  • PDF