• 제목/요약/키워드: Radiology-Pathology correlation

검색결과 62건 처리시간 0.028초

Is there any Potential Clinical Impact of Serum Phosphorus and Magnesium in Patients with Lung Cancer at First Diagnosis? A Multi-institutional Study

  • Kouloulias, Vassilis;Tolia, Maria;Tsoukalas, Nikolaos;Papaloucas, Christos;Pistevou-Gombaki, Kyriaki;Zygogianni, Anna;Mystakidou, Kyriaki;Kouvaris, John;Papaloucas, Marios;Psyrri, Amanda;Kyrgias, George;Gennimata, Vasiliki;Leventakos, Konstantinos;Panayiotides, Ioannis;Liakouli, Zoi;Kelekis, Nikolaos;Papaloucas, Aristofanis
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권1호
    • /
    • pp.77-81
    • /
    • 2015
  • Background: The aim of the study was to determine whether the expression of baseline phosphorus (P) and magnesium (Mg) levels were prognostic in terms of stage and overall survival (OS) in newly diagnosed non-small cell lung cancer (NSCLC) and small cell lung cancer (SCLC) patients. Materials and Methods: Retrospectively, 130 patients were selected at the time of diagnosis oflung cancer (100 with NSCLC and 30 with SCLC), before the initialization of any chemo-radiotherapy. The median age was 67 (range 29-92). IA, IB, IIA, IIB, IIIA, IIIB and IV stages were present in 3, 4, 19, 6, 25, 8, and 65 patients, respectively. After centrifugation, the levels of serum P and Mg were measured using the nephelometric method/ photometry and evaluated before any type of treatment. Results: Higher than normal levels of P were found in 127/130 patients, while only four patients had elevated Mg serum values. In terms of Spearman test, higher P serum values correlated with either stage (rho=- 0.334, p<0.001) or OS (rho=-0.212, p=0.016). Additionally, a significant negative correlation of Mg serum levels was found with stage of disease (rho=-0.135, P=0.042). On multivariate cox-regression survival analysis, only stage (p<0.01), performance status (p<0.01) and P serum (p=0.045) showed a significant prognostic value. Conclusions: Our study indicated that pre-treatment P serum levels in lung cancer patients are higher than the normal range. Moreover, P and Mg serum levels are predictive of stage of disease. Along with stage and performance status, the P serum levels had also a significant impact on survival. This information may be important for stratifying patients to specific treatment protocols or intensifying their therapies. However, larger series are now needed to confirm our results.

Structural complexity of the craniofacial trabecular bone in multiple myeloma assessed by fractal analysis

  • Michels, Mariane;Morais-Faria, Karina;Rivera, Cesar;Brandao, Thais Bianca;Santos-Silva, Alan Roger;Oliveira, Matheus L
    • Imaging Science in Dentistry
    • /
    • 제52권1호
    • /
    • pp.33-41
    • /
    • 2022
  • Purpose: This study aimed to evaluate the structural complexity of craniofacial trabecular bone in multiple myeloma by fractal analysis of panoramic and lateral skull radiography, and to compare the fractal dimension values of healthy patients (HPs), pre-treatment patients (PTPs), and patients during bisphosphonate treatment (DTPs). Materials and Methods: Pairs of digital panoramic and lateral skull radiographs of 84 PTPs and 72 DTPs were selected. After application of exclusion criteria, 43 panoramic and 84 lateral skull radiographs of PTPs, 56 panoramic and 72 lateral skull radiographs of DTPs, and 99 panoramic radiographs of age- and sex-matched HPs were selected. The fractal dimension values from panoramic radiographs were compared among HPs, PTPs, and DTPs and between anatomical locations within patient groups using analysis of variance with the Tukey test. Fractal dimension values from lateral skull radiographs were compared between PTPs and DTPs using the Student t-test. Pearson correlation coefficients were used to assess the relationship between the mandible from panoramic radiographs and the skull from lateral skull radiographs. Intra-examiner agreement was assessed using intraclass correlation coefficients (α=0.05). Results: The fractal dimension values were not significantly different among HPs, PTPs, and DTPs on panoramic radiographs or between PTPs and DTPs on lateral skull radiographs (P>0.05). The mandibular body presented the highest fractal dimension values (P≤0.05). The fractal dimension values of the mandible and skull in PTPs and DTPs were not correlated. Conclusion: Fractal analysis was not sensitive for distinguishing craniofacial trabecular bone complexity in multiple myeloma patients using panoramic and lateral skull radiography.

Diagnostic Accuracy of CT for Evaluating Circumferential Resection Margin Status in Resectable or Borderline Resectable Pancreatic Head Cancer: A Prospective Study Using Axially Sliced Surgical Pathologic Correlation

  • Ji Hoon Park;Yoo-Seok Yoon;Seungjae Lee;Hae Young Kim;Ho-Seong Han;Jun Suh Lee;Won Chang;Haeryoung Kim;Hee Young Na;Seungyeob Han;Kyoung Ho Lee
    • Korean Journal of Radiology
    • /
    • 제23권3호
    • /
    • pp.322-332
    • /
    • 2022
  • Objective: CT plays a central role in determining the resectability of pancreatic cancer, which directs the use of neoadjuvant therapy. This study aimed to assess the diagnostic accuracy of CT in predicting circumferential resection margin (CRM) involvement in patients with resectable or borderline resectable pancreatic head cancer. Materials and Methods: Seventy-seven patients who were scheduled for upfront surgery for resectable or borderline resectable pancreatic head cancer were prospectively enrolled, and 75 patients (38 male and 37 female; mean age ± standard deviation, 68 ± 11 years) were finally analyzed. The CRM status was evaluated separately for the superior mesenteric artery (SMA) and posterior and superior mesenteric vein/portal vein (SMV/PV) margins. Three independent radiologists reviewed the preoperative CT images and evaluated the resection margin status. The reference standard for CRM status was pathologic examination of pancreaticoduodenectomy specimens in an axial plane perpendicular to the axis of the second portion of the duodenum. The diagnostic accuracy of CT was assessed for overall CRM involvement, defined as involvement of the SMA or posterior margins (per-patient analysis), and involvement of each of the three resection margins (per-margin analysis). The data were pooled using a crossed random effects model. Results: Forty patients had pathologically confirmed overall CRM involvement in pancreatic cancer, while CRM involvement was not seen in 35 patients. For overall CRM involvement, the pooled sensitivity and specificity were 15% (95% confidence interval: 7%-49%) and 99% (96%-100%), respectively. For each of the resection margins, the pooled sensitivity and specificity were 14% (9%-54%) and 99% (38%-100%) for the SMA margin, 12% (8%-46%) and 99% (97%-100%) for the posterior margin; and 37% (29%-53%) and 96% (31%-100%) for the SMV/PV margin, respectively. Conclusion: CT showed very high specificity but low sensitivity in predicting pathological CRM involvement in pancreatic cancer.

미세낭종성 혈관종성 혼합 수막종의 영상 및 병리 소견: 증례 보고 (Imaging Features and Pathological Correlation in Mixed Microcystic and Angiomatous Meningioma: A Case Report)

  • 최건우;김대윤;김현진;황교준;김미경;김현곤;백소야
    • 대한영상의학회지
    • /
    • 제83권4호
    • /
    • pp.951-957
    • /
    • 2022
  • 수막종은 가장 흔한 두개내 종양이지만, 그 아형인 미세낭종성 및 혈관종성 수막종은 매우 드물고 특이한 영상 소견으로 인해 영상의학적 진단이 어려울 수 있다. 이에 저자들은 미세낭종성 혈관종성 혼합 수막종으로 진단된 81세 남자 환자 증례를 보고하고자 한다. 자기공명 T2 강조영상에서 병변은 왼쪽 전두부에 약 1.5 cm 크기의 고신호강도의 축외 종양으로 보이고 있었고, 종양 내에 다수의 아주 작은 낭종들이 관찰되었으며, 종양 주위로 포획된 큰 낭을 형성하고 있었다. 수술적 절제를 통한 병리 검사상 미세낭종성 혈관종성 혼합 수막종으로 최종 진단되었다.

Cone-beam computed tomography texture analysis can help differentiate odontogenic and non-odontogenic maxillary sinusitis

  • Andre Luiz Ferreira Costa;Karolina Aparecida Castilho Fardim;Isabela Teixeira Ribeiro;Maria Aparecida Neves Jardini;Paulo Henrique Braz-Silva;Kaan Orhan;Sergio Lucio Pereira de Castro Lopes
    • Imaging Science in Dentistry
    • /
    • 제53권1호
    • /
    • pp.43-51
    • /
    • 2023
  • Purpose: This study aimed to assess texture analysis(TA) of cone-beam computed tomography (CBCT) images as a quantitative tool for the differential diagnosis of odontogenic and non-odontogenic maxillary sinusitis(OS and NOS, respectively). Materials and Methods: CBCT images of 40 patients diagnosed with OS (N=20) and NOS (N=20) were evaluated. The gray level co-occurrence (GLCM) matrix parameters, and gray level run length matrix texture (GLRLM) parameters were extracted using manually placed regions of interest on lesion images. Seven texture parameters were calculated using GLCM and 4 parameters using GLRLM. The Mann-Whitney test was used for comparisons between the groups, and the Levene test was performed to confirm the homogeneity of variance (α=5%). Results: The results showed statistically significant differences(P<0.05) between the OS and NOS patients regarding 3 TA parameters. NOS patients presented higher values for contrast, while OS patients presented higher values for correlation and inverse difference moment. Greater textural homogeneity was observed in the OS patients than in the NOS patients, with statistically significant differences in standard deviations between the groups for correlation, sum of squares, sum of entropy, and entropy. Conclusion: TA enabled quantitative differentiation between OS and NOS on CBCT images by using the parameters of contrast, correlation, and inverse difference moment.

Feasibility and reliability of various morphologic features on magnetic resonance imaging for iliotibial band friction syndrome

  • Jin Kyem Kim;Taeho Kim;Hong Seon Lee;Dong Kyu Kim
    • The Korean Journal of Pain
    • /
    • 제36권2호
    • /
    • pp.208-215
    • /
    • 2023
  • Background: To evaluate the feasibility, inter-reader reliability, and intra-reader reliability for various morphological features reported to be related to iliotibial band friction syndrome (ITBFS) on knee magnetic resonance imaging (MRI). Methods: A total of 145 patients with a clinical diagnosis and knee MRI findings consistent with ITBFS were included in the "study group" and 232 patients without knee pathology on both physical examination and MRI were included in the "control group". Various morphologic features on knee MRI were assessed including the patella shape, patella height, lateral epicondyle anterior-posterior (AP) width, lateral epicondyle height, ITB diameter (ITB-d), and ITB area (ITB-a). Results: Patients in the study group had significantly higher lateral epicondyle height (13.9 mm vs. 12.92 mm, P = 0.003), ITB-d (2.9 mm vs. 2.0 mm, P = 0.022), and ITB-a (38.5 mm2 vs. 23.8 mm2, P < 0.001) than the control group. ITB-a showed higher area under the curve index (0.849 with 74.1% sensitivity and 72.4% specificity at a 30.3 mm2 cutoff) than ITB-d (0.710 with 70.8% sensitivity and 61.2% specificity at 2.4 mm cutoff) and lateral epicondyle height (0.776 with 72.4% sensitivity and 67.8% specificity at 13.4 mm cutoff). However, only the inter-reader agreement for ITB-a (intraclass correlation coefficient = 0.65) was moderate, while the agreements for other morphologic features were good or excellent. Conclusions: Lateral epicondyle height seems to be a reliable and feasible morphologic feature for diagnosis of ITBFS.

Diagnostic Performance of Spin-Echo Echo-Planar Imaging Magnetic Resonance Elastography in 3T System for Noninvasive Assessment of Hepatic Fibrosis

  • Se Woo Kim;Jeong Min Lee;Sungeun Park;Ijin Joo;Jeong Hee Yoon;Won Chang;Haeryoung Kim
    • Korean Journal of Radiology
    • /
    • 제23권2호
    • /
    • pp.180-188
    • /
    • 2022
  • Objective: To validate the performance of 3T spin-echo echo-planar imaging (SE-EPI) magnetic resonance elastography (MRE) for staging hepatic fibrosis in a large population, using surgical specimens as the reference standard. Materials and Methods: This retrospective study initially included 310 adults (155 undergoing hepatic resection and 155 undergoing donor hepatectomy) with histopathologic results from surgical liver specimens. They underwent 3T SE-EPI MRE ≤ 3 months prior to surgery. Demographic findings, underlying liver disease, and hepatic fibrosis pathologic stage according to METAVIR were recorded. Liver stiffness (LS) was measured by two radiologists, and inter-reader reproducibility was evaluated using the intraclass correlation coefficient (ICC). The mean LS of each fibrosis stage (F0-F4) was calculated in total and for each etiologic subgroup. Comparisons among subgroups were performed using the Kruskal-Wallis test and Conover post-hoc test. The cutoff values for fibrosis staging were estimated using receiver operating characteristic (ROC) curve analysis. Results: Inter-reader reproducibility was excellent (ICC, 0.98; 95% confidence interval, 0.97-0.99). The mean LS values were 1.91, 2.41, 3.24, and 5.41 kPa in F0-F1 (n = 171), F2 (n = 26), F3 (n = 38), and F4 (n = 72), respectively. The discriminating cutoff values for diagnosing ≥ F2, ≥ F3, and F4 were 2.18, 2.71, and 3.15 kPa, respectively, with the ROC curve areas of 0.97-0.98 (sensitivity 91.2%-95.9%, specificity 90.7%-99.0%). The mean LS was significantly higher in patients with cirrhosis (F4) of nonviral causes, such as primary biliary cirrhosis (9.56 kPa) and alcoholic liver disease (7.17 kPa) than in those with hepatitis B or C cirrhosis (4.28 and 4.92 kPa, respectively). There were no statistically significant differences in LS among the different etiologic subgroups in the F0-F3 stages. Conclusion: The 3T SE-EPI MRE demonstrated high interobserver reproducibility, and our criteria for staging hepatic fibrosis showed high diagnostic performance. LS was significantly higher in patients with non-viral cirrhosis than in those with viral cirrhosis.

간 섬유화 평가를 위한 MR elastography의 경직도에 대한 Gd-EOB-DTPA의 영향 (The Effect of Gd-EOB-DPTA on the Stiffness Value of Magnetic Resonance Elastography in Evaluating Hepatic Fibrosis)

  • 이정은;이정민;이예지;윤정희;이경분;한준구;최병인
    • Investigative Magnetic Resonance Imaging
    • /
    • 제17권3호
    • /
    • pp.215-223
    • /
    • 2013
  • 목적: 간 섬유화를 평가하기 위한 MR elastography (MRE)의 경직도 (stiffness value)에 미치는 gadoxetic acid의 영향을 평가하고자 하였다. 대상과 방법: 임상적으로 만성 간 질환이 의심되어 자기공명영상을 촬영한 환자 중 조영제 (gadoxetic acid) 주입전과 후에 MRE를 촬영한 32명의 환자를 대상으로 하였다. 두 명의 영상의학과 의사가 간 실질의 경직도를 개별적으로 측정 하였다. 조영 전과 후의 평균 간경직도를 paired t-test를 사용하여 비교하였으며, 평가자내 및 평가자간 상관 관계는 intraclass correlation coefficient (ICC)를 사용하여 분석 하였다. MRE의 F2 이상의 간섬유화 진단의 판별수치로 3.1 kPa을 이용하여 진단의 정확도, 민감도, 특이도를 구하였다. 결과: 조영 전과 후에 측정된 간 경직도의 평균값은 유의한 차이가 없었으며 (p > 0.05), 조영 전 후 모두에서 평가자 내 및 평가자간 우수한 상관 관계가 관찰되었다 (ICC = 0.988 for pre-contrast and ICC = 0.993 for post-contrast, ICC = 0.998 for rater 1 and ICC = 0.996 for rater 2). 간섬유화정도 F2 이상을 진단하는 MRE 의 정확도, 민감도, 특이도는 조영 전후 모두에서 각각 71%, 60%, 그리고 100%로 같은 값을 보였다. 결론: MRE를 이용한 gadoxetic acid 조영 전과 후에 측정된 간경직도는 유의한 차이를 보이지 않았기에 조영 후 MRE 영상도 간 섬유화 평가에 이용될 수 있다.

Cephalometric landmark variability among orthodontists and dentomaxillofacial radiologists: a comparative study

  • Durao, Ana Paula Reis;Morosolli, Aline;Pittayapat, Pisha;Bolstad, Napat;Ferreira, Afonso P.;Jacobs, Reinhilde
    • Imaging Science in Dentistry
    • /
    • 제45권4호
    • /
    • pp.213-220
    • /
    • 2015
  • Purpose: The aim this study was to compare the accuracy of orthodontists and dentomaxillofacial radiologists in identifying 17 commonly used cephalometric landmarks, and to determine the extent of variability associated with each of those landmarks. Materials and Methods: Twenty digital lateral cephalometric radiographs were evaluated by two groups of dental specialists, and 17 cephalometric landmarks were identified. The x and y coordinates of each landmark were recorded. The mean value for each landmark was considered the best estimate and used as the standard. Variation in measurements of the distance between landmarks and measurements of the angles associated with certain landmarks was also assessed by a subset of two observers, and intraobserver and interobserver agreement were evaluated. Results: Intraclass correlation coefficients were excellent for intraobserver agreement, but only good for interobserver agreement. The least reliable landmark for orthodontists was the gnathion (Gn) point (standard deviation [SD], 5.92 mm), while the orbitale (Or) was the least reliable landmark (SD, 4.41 mm) for dentomaxillofacial radiologists. Furthermore, the condylion (Co)-Gn plane was the least consistent (SD, 4.43 mm). Conclusion: We established that some landmarks were not as reproducible as others, both horizontally and vertically. The most consistently identified landmark in both groups was the lower incisor border, while the least reliable points were Co, Gn, Or, and the anterior nasal spine. Overall, a lower level of reproducibility in the identification of cephalometric landmarks was observed among orthodontists.

Effect of Manganese Content on the Magnetic Susceptibility of Ferrous-Manganese Alloys: Correlation between Microstructure on X-Ray Diffraction and Size of the Low-Intensity Area on MRI

  • Youn, Sung Won;Kim, Moon Jung;Yi, Seounghoon;Ahn, Hyun Jin;Park, Kwan Kyu;Lee, Jongmin;Lee, Young-Cheol
    • Investigative Magnetic Resonance Imaging
    • /
    • 제19권2호
    • /
    • pp.76-87
    • /
    • 2015
  • Purpose: There is an ongoing search for a stent material that produces a reduced susceptibility artifact. This study evaluated the effect of manganese (Mn) content on the MRI susceptibility artifact of ferrous-manganese (Fe-Mn) alloys, and investigated the correlation between MRI findings and measurements of Fe-Mn microstructure on X-ray diffraction (XRD). Materials and Methods: Fe-Mn binary alloys were prepared with Mn contents varying from 10% to 35% by weight (i.e., 10%, 15%, 20%, 25%, 30%, and 35%; designated as Fe-10Mn, Fe-15Mn, Fe-20Mn, Fe-25Mn, Fe-30Mn, and Fe-35Mn, respectively), and their microstructure was evaluated using XRD. Three-dimensional spoiled gradient echo sequences of cylindrical specimens were obtained in parallel and perpendicular to the static magnetic field (B0). In addition, T1-weighted spin echo, T2-weighted fast spin echo, and $T2^*$weighted gradient echo images were obtained. The size of the low-intensity area on MRI was measured for each of the Fe-Mn binary alloys prepared. Results: Three phases of ${\alpha}^{\prime}$-martensite, ${\gamma}$-austenite, and ${\varepsilon}$-martensite were seen on XRD, and their composition changed from ${\alpha}^{\prime}$-martensite to ${\gamma}$-austenite and/or ${\varepsilon}$-martensite, with increasing Mn content. The Fe-10Mn and Fe-15Mn specimens comprised ${\alpha}^{\prime}$-martensite, the Fe-20Mn and Fe-25Mn specimens comprised ${\gamma}+{\varepsilon}$ phases, and the Fe-30Mn and Fe-35Mn specimens exhibited a single ${\gamma}$ phase. The size of the low-intensity areas of Fe-Mn on MRI decreased relative to its microstructure on XRD with increasing Mn content. Conclusion: Based on these findings, proper conditioning of the Mn content in Fe-Mn alloys will improve its visibility on MR angiography, and a Mn content of more than 25% is recommended to reduce the magnetic susceptibility artifacts on MRI. A reduced artifact of Fe-Mn alloys on MRI is closely related to the paramagnetic constitution of ${\gamma}$-austenite and/or ${\varepsilon}$-martensite.