• Title/Summary/Keyword: Radiology science department

Search Result 2,933, Processing Time 0.029 seconds

CT/MRI Liver Imaging Reporting and Data System (LI-RADS): Standardization, Evidence, and Future Direction (CT/MRI 간영상 판독과 자료체계: 표준화, 근거 및 발전방향)

  • Yeun-Yoon Kim;Jin-Young Choi
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.1
    • /
    • pp.15-33
    • /
    • 2023
  • The liver imaging reporting and data system (LI-RADS) has been developed with the support of the American College of Radiology to standardize the diagnosis and evaluation of treatment response of hepatocellular carcinoma (HCC). The CT/MRI LI-RADS version 2018 has been incorporated in the American Association for the Study of Liver Diseases guidance. This review examines the effect of CT/MRI LI-RADS on the standardized reporting of liver imaging, and the evidence in diagnosing HCC and evaluating treatment response after locoregional treatment using CT/MRI LI-RADS. The results are compared with other HCC diagnosis guidelines, and future directions are described.

The Analysis of Incidental Findings on Temporomandibular Joint Magnetic Resonance Imaging

  • Choi, Yoon Joo;Lee, Chena;Jeon, Kug Jin;Han, Sang-Sun
    • Journal of Korean Dental Science
    • /
    • v.13 no.1
    • /
    • pp.21-27
    • /
    • 2020
  • Purpose: The aim of this study was to investigate the types and frequency of the various incidental findings (IFs) on magnetic resonance images (MRI) taken from the patients with temporomandibular disorder (TMD) symptoms. Materials and Methods: Temporomandibular joint (TMJ) MRI taken from 1,013 patients with TMD symptoms were evaluated retrospectively. IF was defined as imaging features that were accidentally or unexpectedly found, rather than degenerative bony changes of TMJ complex or disc derangement. They were classified into two groups as TMJ site-specific findings and unexpected findings at other regions. The frequency of the sub groups was analyzed. Result: A total of 26 (2.57%) cases with IFs were classified into 13 cases with TMJ site-specific findings and 13 cases with unexpected findings at other region. TMJ site-specific findings included synovial chondromatosis in 6 cases, synovial cyst in 6 cases and osteochondroma in one case. Unexpected findings included salivary gland tumor in 3 cases, developmental cyst in 3 cases, vascular malformation in 2 cases, mastoiditis in 4 cases and sialadenitis on parotid gland in one case. Conclusion: When diagnosing TMD through TMJ MRI, clinicians should carefully read the image, considering the possibility of IFs because TMJ MRI can provide pathologic information in TMJ region and other oral and maxillofacial region.

Radiologic study of the healing process of the extracted socket of beagle dogs using cone beam CT (Cone beam CT를 이용한 비글견 발치창 치유과정에 대한 방사선학적 연구)

  • Choi, Dong-Hoon;Lee, Wan;Kim, De-Sok;Lee, Byung-Do
    • Imaging Science in Dentistry
    • /
    • v.39 no.1
    • /
    • pp.19-25
    • /
    • 2009
  • Purpose: To longitudinally observe the healing process of extracted socket and the alterations of the residual ridge in healthy adult dogs using cone beam CT (CBCT). Materials and Methods: The mandibular premolars of two beagle dogs were removed and the extraction sites were covered with the gingival tissue. CBCTs (3D X-ray CT scanner, Alphard vega, Asahi Co.) were taken at baseline and at 1 week interval for 12 weeks. Radiographic density of extracted wounds was measured on normalized images with a custom-made image analysis program. The amount of alveolar crestal resorption after the teeth extraction was measured with a reformatted three-dimensional image using CBCT. Bony healing pattern of extracted wound of each group was also longitudinally observed and analyzed. Results: Dimensional changes occurred during the first 6 weeks following the extraction of dogs' mandibular premolars. The reduction of the height of residual ridge was more pronounced at the buccal than at the lingual aspect of the extraction socket. Radiographic density of extracted wounds increased by week 4, but the change in density stabilized after week 6. New bone formation was observed at the floor and the peripheral side of extracted socket from week 1. The entrance of extracted socket was sealed by a hard-tissue bridge at week 5. Conclusion: The healing process of extracted wound involved a series of events including new bone formation and residual ridge resorption.

  • PDF

Quantitative analysis of periapical lesions on cone beam computed tomograph and periapical radiograph (Cone beam형 전산화단층영상과 치근단방사선영상의 치근단 병소에 대한 정량적인 분석)

  • Kim, Jin-Hoa;Lee, Wan;Kim, Kyung-Soo;Roh, Young-Chea;Kim, De-Sok;Lee, Byung-Do
    • Imaging Science in Dentistry
    • /
    • v.39 no.1
    • /
    • pp.41-49
    • /
    • 2009
  • Purpose: To detect the progression of experimentally induced periapical lesions on periapical radiograph and cone beam computed tomograph (CBCT) by quantitative analysis. Materials and Methods: After the removal of coronal pulps from premolars of two Beagle dogs, the root canals of premolars were exposed to oral environment during one week and then sealed for 70 days. Digital periapical radiographs and CBCTs were taken at baseline and every 7 days for 77 days after pulp exposure. We examined occurrence and areas of periapical bone resorption. Three comparative groups of CBCT radiographs were prepared by average projection of thin slabs with different bucco-lingual thicknesses (0.1, 3.0, and 8.0 mm) using a 3D visualization software. Radiographic densities were compensated by image normalization. Digital images were processed with mathematical morphology operations. The radiographic density and morphological features of periapical lesions were compared among three groups of CBCT in different time points. Results: In the CBCT group with 0.1 mm thickness, radiographic density (p<0.05) and trabecular bone area (p<0.01) were significantly decreased at the fifth week. However, in the CBCT groups with 3 mm and 8 mm thickness and periapical radiographs, none of densitometric and morphological features showed any significant differences in different time points. Radiographic density of periapical lesion showed increasing tendency at the eleventh week after pulp exposure. Conclusion: Radiographic detection of periapical lesions was possible at the fifth week after pulp contamination by quantitative method and was affected by buccolingual bone thickness.

  • PDF

A Study on Effectiveness of Designed Composite Filter with Noise Reduction in Ultrasound Image for Diffuse Liver Disease (미만성 간질환의 초음파 영상에서 노이즈 감소를 위한 복합필터의 설계 및 유용성에 관한 연구)

  • Lee, Jin-Soo;Kim, Changsoo;Im, In-Chul;Yang, Sung-Hee
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.2
    • /
    • pp.69-77
    • /
    • 2017
  • This paper proposes a composite filter for noise reduction of image. To improve the image quality by reducing the noise in the liver ultrasound image, we tried to help the accurate image analysis. In the experiment, the top seven composite filters were selected by combining the Gaussian blur filter, the sharpening filter, and the median filter using the ATS-539 ultrasonic phantom, and applied to the ultrasound image in which this was done. As a result, it was found that the values of SNR, CNR and MSR all increased when the top seven composite filters were applied. In addition, PSNR of more than 30 dB, close to SSIM 1 showed that the image loss rate is small. Therefore, the appropriate application of the proposed composite filter in this research will be useful for accurate video reading and analysis.

The Assessment of Tube Incidence Angle for Minimizing the Patellofemoral Joint Overlap Distance in Merchant View (Merchant 검사 시 슬개대퇴관절 겹침 최소화를 위한 중심 X선 입사각에 대한 평가)

  • Ko, Ye-Weon;Joo, Young-Cheol;Kim, Min-suk;Go, Yu-Rim
    • Journal of radiological science and technology
    • /
    • v.43 no.3
    • /
    • pp.161-167
    • /
    • 2020
  • This study aimed to found out the effect of patellofemoral overlap distance by changing femur thickness and center X-ray angles in Merchant method images. Based on the femur thickness, it suggested tube angle minimizes overlap. It was conducted by Merchant method, a knee tangential view, and the image was obtained by changing the thigh thickness from 14 to 20 cm and the center ray angle from 60°, 57°, 55°. The images were measured by five researchers using a method of measuring the overlap, which was designed by them. The results showed at 60°, 57°, 55° angle, the patellofemoral overlap distance resulted in 0.47±0.66 to 20.89±0.65 cm, 2.26±0.28 to 15.73±0.62 cm, 1.39 ± 0.83 to 12.49 ± 0.37 cm. However, for 57° and 55°, no overlap in thickness under 14.5 and 14 to 15.5 didn't appear. it showed high correlation between femur thickness and overlap. The difference in the mean value of overlap in each group showed a statistically significant difference (p<0.01), all were classified as independent groups in the post-hoc test. In all images, the patellofemoral overlap distance increased as the thickness increased, and at the average thickness of Korean men and women, overlap decreased when reducing center ray. When conducting Merchant tests on Koreans, it was suggested it would be useful to use 57° angle because it minimize the effects of overlap and intrusions of tibia.

A Study on how to Utilize the DR System using Assistive Devices (보조기구를 이용한 DR System 활용 방법에 대한 연구)

  • Seon-Yeol, Seo;Jeong-Ho, Kim;Jin-Ok, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.115-122
    • /
    • 2023
  • The hip joint device is an important immobilization device for internal rotation in the diagnosis of bone density test, microfracture, and arthritis. These fixing mechanisms have limitations in maintaining reproducibility due to the use of Velcro. In this study, we developed an improved hip joint device and evaluated its usefulness. For 30 students enrolled in the Department of Radiology, we evaluated the reproducibility through medical imaging and the time required for positioning by applying the conventionaling and improved device. Changes over time were also evaluated. As a result, compared to the conventional device, the improved device showed a 32% reduction in positioning time and improved reproducibility by about 6.2 times. As for the amount of change over time, the positioning time increased in the conventional device, but decreased in the improved device, and the reproducibility of the conventional device was lower than that of the improved device. Through this, it can be said that the use of the improved device improved the image quality and reduced the radiologist's workload.

Assessment of Dose and Image Quality according to the Change of Distance from Source to Image Receptor and the Examination Posture during the Skull Lateral Radiography (두부 측 방향 방사선검사 시 선원 영상수용체간 거리와 검사 자세 변화가 선량과 영상품질에 미치는 영향)

  • Eun-Hye, Kim;Young-Cheol, Joo;Han-Yong, Kim;Dong-Hwan, Kim
    • Journal of radiological science and technology
    • /
    • v.45 no.6
    • /
    • pp.483-489
    • /
    • 2022
  • This study proposes a new skull lateral examination, and provides an improved examination environment for patients and radiologists. The study was divided into three groups. One group was divided into the SID (source to image receptor distance) 110 ㎝ and 180 ㎝ in the skull lateral posture, the other group The other group was divided into an position in contact with the detector and an position without contact with the detector, and the other group was divided into male and female groups, considering that the difference in shoulder width between adult males and females would affect the dose and image quality. For dose evaluation, the ESD (entrance surface dose) was measured at the EAM (external auditory meatus), and the conditions were applied equally at 70 ㎸p, 200 ㎃, and 10 ㎃s. For image quality evaluation, SNR (signal to noise ratio) and CNR (contrast to noise ratio) were measured in frontal sinus, EAM, and sella turcica. As a result of ESD comparison, when sid 110 ㎝ to sid 180 ㎝ was changed among the three groups, ESD values decreased the most to 729.18±4.62 μ㏉ and 224.18±0.74 μ㏉ at 180 ㎝ (p<0.01). The values of SNR and CNR were statistically significant (p<0.01), but there was no qualitative difference. This shows that when the SID is 180 ㎝, it is possible to reduce the dose without lowering the image quality. So, It is suggested that the SID 180 ㎝ is used without contacting the detector when examining the skull lateral.

Intra- and interobserver agreement of computed tomography in assessment of the mandibular condyle

  • Cho, Bong-Hae;Jung, Yun-Hoa
    • Imaging Science in Dentistry
    • /
    • v.37 no.4
    • /
    • pp.191-195
    • /
    • 2007
  • Purpose: To study the intra- and interobserver agreement of multidetector row computed tomography (MDCT) in interpretation of degenerative changes of the mandibular condyle. Materials and Methods: Five observers independently evaluated one hundred temporomandibular joint MDCT images for signs of osteophytes, erosion, sclerosis and flattening. The intra- and interobserver agreements were calculated by using Kappa statistics. Results: The intraobserver agreement was substantial for erosion (k=0.75), flattening (k=0.74) and sclerosis (k=0.72) and almost perfect for osteophytes (k=0.84). The interobserver agreement was fair for flattening (k=0.39), moderate for erosion (k=0.58) and sclerosis (k=0.48) and substantial for osteophytes (k=0.75). Conclusion: This study shows that we can expect good agreement for the presence of osteophytes, but not for flattening in the interpretation of MDCT images of the condyle.

  • PDF

The relationship among reference lines used for taking the extraoral radiography (구외 방사선사진 촬영에 사용되는 기준선의 상호 관계)

  • Lee Sul-Mi;Choi Hang-Moon
    • Imaging Science in Dentistry
    • /
    • v.31 no.4
    • /
    • pp.205-207
    • /
    • 2001
  • Purpose : The aim of present study is to estimate the relationship among reference lines used for taking the extraoral radiography and panoramic radiography. Materials and Methods: Lateral cephalographs of 40 adults, aged 22 to 30 years were taken. Angles between reference lines (Frankfort line, canthomeatal line, infraorbitomeatal line, and occlusal plane) were measured. Results: Angles between Frankfort line and canthomeatal line, Frankfort line and infraorbitomeatal line, Frankfort line and occlusal plane, canthomeatal line and infraorbitomeatal line, canthomeatal line and occlusal plane, and infraorbitomeatal line and occlusal plane were 16.1° (±2.2), 5.8° (±2.4), 8.7° (±3.5), 10.3° (±1.3), 24.8° (±4.0), and 14.5° (±4.4),respectively. Conclusion: Angle between frankfort and canthomeatal line is very different with commonly known angle. Frankfort horizontal reference lines used for panoramic radiography need an exact definition and more accurate standard is needed for the taking of panoramic radiograph.

  • PDF