• Title/Summary/Keyword: Radiology science department

Search Result 2,933, Processing Time 0.033 seconds

Evaluation of the postoperative maxillary sinus with computed tomography

  • Kim Hee-Kyung;Heo Min-Suk;Lee Sam-Sun;Choi Hyun-Bae;Choi Soon-Chul;Park Tae-Won
    • Imaging Science in Dentistry
    • /
    • v.32 no.4
    • /
    • pp.195-200
    • /
    • 2002
  • Purpose: To evaluate the computed tomographic appearances of post-operative maxillary sinuses. Materials and Methods: 33 asymptomatic cases of post-operative maxillary sinus without evidence of any pathologic changes and clinical symptoms were selected. CT images were classified as opacification, soft tissue shadow, anterior wall depression, naso-antral communication, and compartmentalization. The relationships between the CT image and the age of patients at the time of operatation, and between the CT image and the duration of time elapsed since the surgical procedure were evaluated. Results: The most commonly presented radiological characteristics that occurred after the Caldwell-Luc procedure were opacification and soft tissue shadow. Anterior wall depression and naso-antral communication were radiographic indications that a Caldwell-Luc operation had been carried out. The age of patients when they had been first operated on, and the duration between the surgical procedure and the time of evaluation had no effect on the CT appearances of normal changes. In cases involving a longer time interval between the antral surgery and evaluation, the anterior wall depression with bony healing was more commonly observed than soft tissue healing. Conclusion: The radiographic information regarding the normal healing state using computed tomography can distinguish post-operative changes from inflammatory and cystic disease in patients who have undergone a Caldwell-Luc type of radical maxillary antrostomy.

  • PDF

Radiographic evaluation of the zygomatic air cell defect

  • Park Young-Hee;Lee Soo-Kyung;Park Byeong-Hyun;Son Hyo-Sun;Choi Mi;Choi Karp-Shik;An Chang-Hyeon
    • Imaging Science in Dentistry
    • /
    • v.32 no.4
    • /
    • pp.207-211
    • /
    • 2002
  • Purpose : The purpose of this study was to determine the prevalence, radiographic appearance, and characteristics of patients with zygomatic air cell defect (ZACD), and to give recommendations concerning radiographic evaluation and surgery. Materials and Methods: Routine panoramic radiographs of 1,400 patients admitted to the Kyungpook National University Hospital Dental Clinic, were retrospectively examined for the clinical and radiographic features of ZACD. Results: ZACD was found in 31 cases, representing a prevalence of 2.2%. Patients with ZACD had a mean age of 27.5 years and a range of 9-52 years. Most ZACD cases were in their thirties. ZACD showed a strong male prediliction, 22 of the 31 subjects were males and 9 were females. Twenty-four cases of ZACD (77.4%) were unilateral, with the half occurring on the right side. In seven cases (22.6%), ZACD was bilateral. Twenty-six (68.4%) of the defects were of unilocular, while twelve (31.6%) of the defects were multilocular. Conclusion: Knowledge of ZACD may be helpful in interpreting images, including panoramic radiographs, in planning surgical treatment of the TMJ and in understanding the spread of pathological processes into the joint.

  • PDF

Reproducibility of lateral cephalometric landmarks on conventional radiographs and spatial frequency-processed digital images

  • Shin Jeong-Won;Choi Hang-Moon;Heo Min-Suk;Lee Sam-Sun;Choi Hyun-Bae;Choi Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.32 no.4
    • /
    • pp.213-219
    • /
    • 2002
  • Purpose : Computed radiography (CR) has been used in cephalometric radiography and many studies have been carried out to improve image quality using various digital enhancement and filtering techniques, During CR image acquisition, the frequency rank and type affect to the image quality. The aim of this study was to compare the diagnostic quality of conventional cephalometric radiographs to those of computed radiography. Materials and Methods : The diagnostic quality of conventional cephalometric radiographs (MO) and their digital image counterparts were compared, and at the same time, six modalities (M1-M6) of spatial frequency-processed digital images were compared by evaluating the reproducibility of 23 cephalometric landmark locations. Reproducibility was defined as an observer's deviation (in mm) from the mean between all observers. Results and Conclusion: In comparison with the conventional cephalometric radiograph (MO), Ml showed statistically significant differences in 8 locations, M2 in 9, M3 12, M4 in 7, M5 in 12, and M6 showed significant differences in 14 of 23 landmark locations (p < 0.05). The number of reproducible landmarks that each modality possesses were 7 in M6, 6 in M5, 5 in M3, 4 in M4, 3 in M2, 2 in Ml, and 1 location in MO. The image modality that observers selected as having the best image quality was M5.

  • PDF

Comparison of the diagnostic performance of panoramic and occlusal radiographs in detecting submandibular sialoliths

  • Kim, Jun Ho;Aoki, Eduardo Massaharu;Cortes, Arthur Rodriguez Gonzalez;Abdala-Junior, Reinaldo;Asaumi, Junichi;Arita, Emiko Saito
    • Imaging Science in Dentistry
    • /
    • v.46 no.2
    • /
    • pp.87-92
    • /
    • 2016
  • Purpose: The aim of this study was to assess and compare the diagnostic performance of panoramic and occlusal radiographs in detecting submandibular sialoliths. Materials and Methods: A total of 40 patients (20 cases and 20 controls) were included in this retrospective study. Cases were defined as subjects with a submandibular sialolith confirmed by computed tomography (CT), whereas controls did not have any submandibular calcifications. Three observers with different expertise levels assessed panoramic and occlusal radiographs of all subjects for the presence of sialoliths. Intraobserver and interobserver agreement were assessed using the kappa test. Sensitivity, specificity, accuracy, positive and negative predictive values, and the diagnostic odds ratio of panoramic and occlusal radiographs in screening for submandibular sialoliths were calculated for each observer. Results: The sensitivity and specificity values for occlusal and panoramic radiographs all ranged from 80% to 100%. The lowest values of sensitivity and specificity observed among the observers were 82.6% and 80%, respectively (P=0.001). Intraobserver and interobserver agreement were higher for occlusal radiographs than for panoramic radiographs, although panoramic radiographs demonstrated a higher overall accuracy. Conclusion: Both panoramic and occlusal radiographic techniques displayed satisfactory diagnostic performance and should be considered before using a CT scan to detect submandibular sialoliths.

Diagnostic reference levels in intraoral dental radiography in Korea

  • Kim, Eun-Kyung;Han, Won-Jeong;Choi, Jin-Woo;Jung, Yun-Hoa;Yoon, Suk-Ja;Lee, Jae-Seo
    • Imaging Science in Dentistry
    • /
    • v.42 no.4
    • /
    • pp.237-242
    • /
    • 2012
  • Purpose: The objectives of this study were to survey the radiographic exposure parameters, to measure the patient doses for intraoral dental radiography nationwide, and thus to establish the diagnostic reference levels (DRLs) in intraoral dental X-ray examination in Korea. Materials and Methods: One hundred two intraoral dental radiographic machines from all regions of South Korea were selected for this study. Radiographic exposure parameters, size of hospital, type of image receptor system, installation duration of machine, and type of dental X-ray machine were documented. Patient entrance doses (PED) and dose-area products (DAP) were measured three times at the end of the exit cone of the X-ray unit with a DAP meter (DIAMENTOR M4-KDK, PTW, Freiburg, Germany) for adult mandibular molar intraoral dental radiography, and corrections were made for room temperature and pressure. Measured PED and DAP were averaged and compared according to the size of hospital, type of image receptor system, installation duration, and type of dental X-ray machine. Results: The mean exposure parameters were 62.6 kVp, 7.9 mA, and 0.5 second for adult mandibular molar intraoral dental radiography. The mean patient dose was 2.11 mGy (PED) and 59.4 $mGycm^2$ (DAP) and the third quartile one 3.07 mGy (PED) and 87.4 $mGycm^2$ (DAP). Doses at university dental hospitals were lower than those at dental clinics (p<0.05). Doses of digital radiography (DR) type were lower than those of film-based type (p<0.05). Conclusion: We recommend 3.1 mGy (PED), 87.4 $mGycm^2$ (DAP) as the DRLs in adult mandibular molar intraoral dental radiography in Korea.

Effect of Radiology Department Students' Motivation for Major Selection and Satisfaction on University Life Adjustment (방사선(학)과 학생들의 전공 선택 동기 및 전공 만족도가 대학생활 적응에 미치는 영향)

  • Yang, Sung-Hee;Koo, Jae-Heung
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.5
    • /
    • pp.657-666
    • /
    • 2021
  • This study was conducted to understand the motivation for major selection and degree of satisfaction with major for university students in the department of Radiology, and to analyze the effect university life adjustment in COVID-19. From Jung 20 to July 20, 2021, 308 students in grades 1~4 were enrolled at universities in Busan and Gyeongnam. Factors influencing university life adjustment were found to have a good adjustment when majoring was selected with personal motive rather than social motive. Among the sub-factors of major satisfaction, general satisfaction and satisfaction with surrounding relationships had a positive effect on university life adjustment. Therefore, in order to adapt to healthy university life, it is necessary to secure closeness between school, professor, and students, and it is desirable to provide students with opportunities to experience various education by recognizing the rapidly changing policy changes in education to increase major satisfaction. Based on the results of this study, it is expected that the results of this study will be used as basic data for successful university life of students in the department of radiology.

Cone-beam computed tomography artifacts in the presence of dental implants and associated factors: An integrative review

  • Terrabuio, Bianca Rodrigues;Carvalho, Caroline Gomes;Peralta-Mamani, Mariela;da Silva Santos, Paulo Sergio;Rubira-Bullen, Izabel Regina Fischer;Rubira, Cassia Maria Fischer
    • Imaging Science in Dentistry
    • /
    • v.51 no.2
    • /
    • pp.93-106
    • /
    • 2021
  • Purpose: This study was conducted to review the literature regarding the types of cone-beam computed tomography (CBCT) artifacts around dental implants and the factors that influence their formation. Materials and Methods: A search strategy was carried out in the PubMed, Embase, and Scopus databases to identify published between 2010 and 2020, and 9 studies were selected. The implants included 306 titanium, titanium-zirconium, and zirconia implants, as well as 5 titanium cylinders. Results: The artifacts around the implants were the beam-hardening artifact, the streaking artifact, and band-like radiolucent areas. Some factors that influenced the formation of artifacts were the implant material, bone type, evaluated regions, distance, type of CBCT, field of view (FOV) size, milliamperage, peak kilovoltage (kVp), and voxel size. The beam-hardening artifact was the most widely reported, and it was minimized in protocols with a smaller FOV, larger voxels, and higher kVp. Conclusion: The risk and benefit of these protocols in individuals with dental implants must be considered, and clinical examinations and complementary radiographs play an essential role in implantology.

Assessment of the dimensions of the pterygoid hamulus for establishing age- and sex-specific reference standards using cone-beam computed tomography

  • Mehra, Archana;Karjodkar, Freny R.;Sansare, Kaustubh;Kapoor, Ruchika;Tambawala, Shahnaz;Saxena, Vasu Siddhartha
    • Imaging Science in Dentistry
    • /
    • v.51 no.1
    • /
    • pp.49-54
    • /
    • 2021
  • Purpose: This study was conducted to establish age- and sex-specific reference standards for pterygoid hamulus(PH) dimensions using cone-beam computed tomography (CBCT). Materials and Methods: CBCT scans of 1,000 patients(493 males and 507 females) were retrospectively assessed in coronal sections for length and width measurements of the PH by 3 investigators. The study data were divided into 3 age groups(group 1: <20 years, group 2: 20-50 years, group 3: >50 years). Length and width were compared using one-way analysis of variance and the t-test for age and sex, respectively. Results: The length of the PH on the right side significantly increased from group 1 (6.11±1.47mm), through group 2 (6.65±1.67 mm) to group 3 (6.99±1.79 mm) and on the left side from group 2 (6.58±1.63) to group 3 (6.98±1.70). The width of the PH significantly decreased from group 1 (1.81±0.39 mm) to group 2 (1.61±0.39 mm) on the right side, and similarly from 1.87±0.36mm to 1.67±0.37mm on the left side. PH length (7.18±1.81mm on the right side and 7.10±1.72 mm on the left side) and width (1.68±0.38 mm on the right side and 1.74±0.36 mm on the left side) were significantly greater in males than in females. Conclusion: The length of the PH increased with age, whereas width first decreased and then increased. Length and width measurements were significantly higher in males than in females. These findings will aid in the diagnosis of untraceable pain in the oropharyngeal region related to altered PH morphology.

Efficacy of corticosteroid ductal irrigation in acute salivary gland inflammation induced in a rat model

  • Lee, Chena;Lee, Ari;Kim, Hak-Sun;Choi, Yoon Joo;Jeon, Kug Jin;Han, Sang-Sun
    • Imaging Science in Dentistry
    • /
    • v.52 no.1
    • /
    • pp.61-66
    • /
    • 2022
  • Purpose: This study aimed to compare the therapeutic effects of corticosteroid irrigations and normal saline irrigations in the early inflammatory state of the salivary gland. Materials and Methods: Adult male Wistar rats were divided into experimental (n=6) and control (n=3) groups. Inflammation was induced in the experimental subjects on both sides of the submandibular gland with ligation. After 14 days, both sides of the glands were de-ligated and retroductal irrigation using saline (n=3) and a corticosteroid (n=3) was performed on the left sides only. The controls (n=3) were used to normalize the gland state for the effects of diet and aging. Magnetic resonance imaging was performed to confirm inflammation and post-irrigation gland recovery by measuring relative signal intensity (SI). The glands were excised for histological examination. Results: All experimental animals showed inflamed glands with increased SI and subsequent recovery of the gland with decreased SI to varying degrees. The SI of the controls showed no significant changes during the overall period. The mean SI change of the irrigated gland was higher than that of the non-irrigated side, without a significant difference. The corticosteroid-irrigated glands showed a greater change in SI than that of the saline-irrigated glands. Histology revealed that inflammation was not observed in most of the irrigated glands, while mild to moderate quantities inflammatory cells were found in non-irrigated glands. Conclusion: Corticosteroid irrigation mitigated the early stages of salivary gland inflammation more effectively than normal saline.

Transfer learning in a deep convolutional neural network for implant fixture classification: A pilot study

  • Kim, Hak-Sun;Ha, Eun-Gyu;Kim, Young Hyun;Jeon, Kug Jin;Lee, Chena;Han, Sang-Sun
    • Imaging Science in Dentistry
    • /
    • v.52 no.2
    • /
    • pp.219-224
    • /
    • 2022
  • Purpose: This study aimed to evaluate the performance of transfer learning in a deep convolutional neural network for classifying implant fixtures. Materials and Methods: Periapical radiographs of implant fixtures obtained using the Superline (Dentium Co. Ltd., Seoul, Korea), TS III(Osstem Implant Co. Ltd., Seoul, Korea), and Bone Level Implant(Institut Straumann AG, Basel, Switzerland) systems were selected from patients who underwent dental implant treatment. All 355 implant fixtures comprised the total dataset and were annotated with the name of the system. The total dataset was split into a training dataset and a test dataset at a ratio of 8 to 2, respectively. YOLOv3 (You Only Look Once version 3, available at https://pjreddie.com/darknet/yolo/), a deep convolutional neural network that has been pretrained with a large image dataset of objects, was used to train the model to classify fixtures in periapical images, in a process called transfer learning. This network was trained with the training dataset for 100, 200, and 300 epochs. Using the test dataset, the performance of the network was evaluated in terms of sensitivity, specificity, and accuracy. Results: When YOLOv3 was trained for 200 epochs, the sensitivity, specificity, accuracy, and confidence score were the highest for all systems, with overall results of 94.4%, 97.9%, 96.7%, and 0.75, respectively. The network showed the best performance in classifying Bone Level Implant fixtures, with 100.0% sensitivity, specificity, and accuracy. Conclusion: Through transfer learning, high performance could be achieved with YOLOv3, even using a small amount of data.