• Title/Summary/Keyword: Radiology science department

Search Result 2,933, Processing Time 0.03 seconds

Effect of radiation dose variation on expression of caspase-3 in rat submandibular glands (방사선 조사선량에 따른 백서 악하선의 caspase-3 발현양상)

  • Kwon Ki-Jeong;Choi Yong-Suk;Hwang Eui-Hwan;Lee Sang-Rae;Koh Kwang-Joon
    • Imaging Science in Dentistry
    • /
    • v.36 no.1
    • /
    • pp.7-15
    • /
    • 2006
  • Purpose : To investigate the caspase-3 expression in the acinar and ductal cells of rat submandibular glands after the irradiation of various doses. Materials and Methods : The male Sprague-Dawley rats weighing approximately 250 gm were used for this study. The experimental group was irradiated with a single absorbed dose of 2, 5, 10, and 15 Gy on the head and neck region. The rats were sacrificed on the 1st, 3rd, 7th, 14th, 21 st, and 28th day after irradiation. The specimens including the submandibular gland were sectioned and observed using histopathological and immunohistochemical methods. Results : The local destruction of the acinar and ductal cells and the karyopyknotic nuclei of the acinar cells were observed in the 2 Gy and 5 Gy irradiation groups later than in the 10 Gy and 15 Gy irradiation groups. And the expression of caspase-3 was prominent only in the ductal cells in the 2 Gy and 5 Gy irradiation groups. Conclusion : This experiment suggests that radiation-induced apoptosis in the ductal cells of rat submandibular glands was induced by a low dose radiation associated with the activation of caspase-3 and radiation-induced necrosis was induced by a high dose radiation.

  • PDF

Convolutional neural networks for automated tooth numbering on panoramic radiographs: A scoping review

  • Ramadhan Hardani Putra;Eha Renwi Astuti;Aga Satria Nurrachman;Dina Karimah Putri;Ahmad Badruddin Ghazali;Tjio Andrinanti Pradini;Dhinda Tiara Prabaningtyas
    • Imaging Science in Dentistry
    • /
    • v.53 no.4
    • /
    • pp.271-281
    • /
    • 2023
  • Purpose: The objective of this scoping review was to investigate the applicability and performance of various convolutional neural network (CNN) models in tooth numbering on panoramic radiographs, achieved through classification, detection, and segmentation tasks. Materials and Methods: An online search was performed of the PubMed, Science Direct, and Scopus databases. Based on the selection process, 12 studies were included in this review. Results: Eleven studies utilized a CNN model for detection tasks, 5 for classification tasks, and 3 for segmentation tasks in the context of tooth numbering on panoramic radiographs. Most of these studies revealed high performance of various CNN models in automating tooth numbering. However, several studies also highlighted limitations of CNNs, such as the presence of false positives and false negatives in identifying decayed teeth, teeth with crown prosthetics, teeth adjacent to edentulous areas, dental implants, root remnants, wisdom teeth, and root canal-treated teeth. These limitations can be overcome by ensuring both the quality and quantity of datasets, as well as optimizing the CNN architecture. Conclusion: CNNs have demonstrated high performance in automated tooth numbering on panoramic radiographs. Future development of CNN-based models for this purpose should also consider different stages of dentition, such as the primary and mixed dentition stages, as well as the presence of various tooth conditions. Ultimately, an optimized CNN architecture can serve as the foundation for an automated tooth numbering system and for further artificial intelligence research on panoramic radiographs for a variety of purposes.

Correlation between cone-beam computed tomographic findings and the apnea-hypopnea index in obstructive sleep apnea patients: A cross-sectional study

  • Marco Isaac;Dina Mohamed ElBeshlawy;Ahmed Elsobki;Dina Fahim Ahmed;Sarah Mohammed Kenawy
    • Imaging Science in Dentistry
    • /
    • v.54 no.2
    • /
    • pp.147-157
    • /
    • 2024
  • Purpose: The aim of this study was to explore the correlations of cone-beam computed tomographic findings with the apnea-hypopnea index in patients with obstructive sleep apnea. Materials and Methods: Forty patients with obstructive sleep apnea were selected from the ear-nose-throat (ENT) outpatient clinic, Faculty of Medicine, Mansoura University. Cone-beam computed tomography was performed for each patient at the end of both inspiration and expiration. Polysomnography was carried out, and the apnea-hypopnea index was obtained. Linear measurements, including cross-sectional area and the SNA and SNB angles, were obtained. Four oral and maxillofacial radiologists categorized pharyngeal and retropalatal airway morphology and calculated the airway length and volume. Continuous data were tested for normality using the Kolmogorov-Smirnov test and reported as the mean and standard deviation or as the median and range. Categorical data were presented as numbers and percentages, and the significance level was set at P<0.05. Results: The minimal value of the cross-sectional area, SNB angle, and airway morphology at the end of inspiration demonstrated a statistically significant association (P<0.05) with the apnea-hypopnea index, with excellent agreement. No statistically significant difference was found in the airway volume, other linear measurements, or retropalatal airway morphology. Conclusion: Cone-beam computed tomographic measurements in obstructive sleep apnea patients may be used as a supplement to a novel radiographic classification corresponding to the established clinical apnea-hypopnea index classification.

Sjogren′s Syndrome Combined with MALT Lymphoma (MALT 림프종을 수반한 쉐그렌 증후군)

  • Han Won-Jeong;Cha Sang-Yun;Kim Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • v.30 no.2
    • /
    • pp.144-148
    • /
    • 2000
  • Sjogren's syndrome is a chronic inflammatory disease that predominantly affects salivary, lacrimal and other exocrine glands. We report a case of Sjogren's syndrome combined with MALT (mucose associated lymphoid tissue) lymphoma which occured in the parotid gland. A 57-year-old female with the complaint of painful swelling and lymph node enlargement was referred to our department. Sialograms of both parotid glands showed globular collections of contrast material uniformly distributed throughout the parotid gland. Salivary scintigraphy showed decreased uptake of the parotid gland. CT scan showed larger, slightly more dense parotid gland than normal and honeycomb glandular appearance. Also, It showed discrete, slightly more enhanced round mass in the left parotid gland. Histopathological finding showed replacement of salivary gland parenchyma with dense small lymphocytic infiltration having the feature of epimyoepithelial islands. Kappa light chain restriction of interglandular plasma cell could be seen.

  • PDF

Ellis-van Creveld syndrome in an Indian child: a case report

  • Veena, K.M.;Jagadishchandra, H.;Rao, Prasanna Kumar;Chatra, Laxmikanth
    • Imaging Science in Dentistry
    • /
    • v.41 no.4
    • /
    • pp.167-170
    • /
    • 2011
  • Ellis-van Creveld syndrome is a rare congenital genetic disorder having autosomal recessive inheritance. It is a syndrome affecting the Amish population of Pennsylvania in USA with prevalence rate of 1/5,000 live at birth. In non-Amish population, the birth prevalence is 7/1,000,000. The syndrome is characterized by bilateral postaxial polydactyly of the hands, chondrodysplasia of long bones resulting in acromesomelic dwarfism, ectodermal dysplasia affecting nails as well as teeth and congenital heart malformation. There were very rare reports of this syndrome in dentistry. The present case focuses on the striking and constant oral findings of these patients, which are the main diagnostic features of this syndrome. Since the oral manifestations affect the esthetic, speech, and jaw growth of the child, the dentists have an important role to play in proper management of such case.

Fourth molar: A retrospective study and literature review of a rare clinical entity

  • Bamgbose, Babatunde O.;Okada, Shunsuke;Hisatomi, Miki;Yanagi, Yoshinobu;Takeshita, Yohei;Abdu, Zahrau Saleh;Ekuase, Edugie J.;Asaumi, Jun-ichi
    • Imaging Science in Dentistry
    • /
    • v.49 no.1
    • /
    • pp.27-34
    • /
    • 2019
  • Purpose: The prevalence of supernumerary teeth has been reported to be between 0.1% and 3.8%. The aim of this study was to determine the prevalence, clinical significance, and associated pathologies of fourth molars based on a retrospective study and a literature review. Materials and Methods: A 5-year retrospective prevalence study was conducted at the Department of Oral Diagnosis and Dentomaxillofacial Radiology of Okayama University Hospital, Okayama, Japan. The study involved extracting data from the digital records of patients from January 1, 2013 through December 31, 2017. The sampling frame included all patients who had panoramic radiographs, cone-beam computed tomography (CT), and multislice CT images during the period under review. Results: A total of 26,721 cases were reviewed and 87 fourth molars were identified. The prevalence of fourth molars in the 5-year study at Okayama was calculated as 0.32%. The mean age of patients with a fourth molar was 30.43 years, and the male-to-female ratio was 1:0.98. The vast majority of cases were in the maxilla (92%) and had normal shapes(89.7%); furthermore, 82.8% of cases were unerupted. Conclusion: The prevalence of fourth molars in the study population was found to be 0.32%, and fourth molars occurred with approximately equal frequency in males and females. Fourth molars were more common in the maxilla and were predominantly unerupted and small.

Diffusion-Weighted Imaging for Differentiation of Biliary Atresia and Grading of Hepatic Fibrosis in Infants with Cholestasis

  • Jisoo Kim;Hyun Joo Shin;Haesung Yoon;Seok Joo Han;Hong Koh;Myung-Joon Kim;Mi-Jung Lee
    • Korean Journal of Radiology
    • /
    • v.22 no.2
    • /
    • pp.253-262
    • /
    • 2021
  • Objective: To determine whether the values of hepatic apparent diffusion coefficient (ADC) can differentiate biliary atresia (BA) from non-BA or be correlated with the grade of hepatic fibrosis in infants with cholestasis. Materials and Methods: This retrospective cohort study included infants who received liver MRI examinations to evaluate cholestasis from July 2009 to October 2017. Liver ADC, ADC ratio of liver/spleen, aspartate aminotransferase to platelet ratio index (APRI), and spleen size were compared between the BA and non-BA groups. The diagnostic performances of all parameters for significant fibrosis (F3-4) were obtained by receiver-operating characteristics (ROCs) curve analysis. Results: Altogether, 227 infants (98 males and 129 females, mean age = 57.2 ± 36.3 days) including 125 BA patients were analyzed. The absolute ADC difference between two reviewers was 0.10 mm2/s for both liver and spleen. Liver ADC value was specific (80.4%) and ADC ratio was sensitive (88.0%) for the diagnosis of BA with comparable performance. There were 33 patients with F0, 15 with F1, 71 with F2, 35 with F3, and 11 with F4. All four parameters of APRI (τ = 0.296), spleen size (τ = 0.312), liver ADC (τ = -0.206), and ADC ratio (τ = -0.288) showed significant correlation with fibrosis grade (all, p < 0.001). The cutoff values for significant fibrosis (F3-4) were 0.783 for APRI (area under the ROC curve [AUC], 0.721), 5.9 cm for spleen size (AUC, 0.719), 1.044 x 10-3 mm2/s for liver ADC (AUC, 0.673), and 1.22 for ADC ratio (AUC, 0.651). Conclusion: Liver ADC values and ADC ratio of liver/spleen showed limited additional diagnostic performance for differentiating BA from non-BA and predicting significant hepatic fibrosis in infants with cholestasis.

Pre- and Immediate Post-Kasai Portoenterostomy Shear Wave Elastography for Predicting Hepatic Fibrosis and Native Liver Outcomes in Patients With Biliary Atresia

  • Haesung Yoon;Kyong Ihn;Jisoo Kim;Hyun Ji Lim;Sowon Park;Seok Joo Han;Kyunghwa Han;Hong Koh;Mi-Jung Lee
    • Korean Journal of Radiology
    • /
    • v.24 no.5
    • /
    • pp.465-475
    • /
    • 2023
  • Objective: To evaluate the feasibility of ultrasound shear wave elastography (SWE) for predicting hepatic fibrosis and native liver outcomes in patients with biliary atresia. Materials and Methods: This prospective study included 33 consecutive patients with biliary atresia (median age, 8 weeks [interquartile range, 6-10 weeks]; male:female ratio, 15:18) from Severance Children's Hospital between May 2019 and February 2022. Preoperative (within 1 week from surgery) and immediate postoperative (on postoperative days [PODs] 3, 5, and 7) ultrasonographic findings were obtained and analyzed, including the SWE of the liver and spleen. Hepatic fibrosis, according to the METAVIR score at the time of Kasai portoenterostomy and native liver outcomes during postsurgical follow-up, were compared and correlated with imaging and laboratory findings. Poor outcomes were defined as intractable cholangitis or liver transplantation. The diagnostic performance of SWE in predicting METAVIR F3-F4 and poor hepatic outcomes was analyzed using receiver operating characteristic (ROC) analyses. Results: All patients were analyzed without exclusion. Perioperative advanced hepatic fibrosis (F3-F4) was associated with older age and higher preoperative direct bilirubin and SWE values in the liver and spleen. Preoperative liver SWE showed a ROC area of 0.806 and 63.6% (7/11) sensitivity and 86.4% (19/22) specificity at a cutoff of 17.5 kPa for diagnosing F3-F4. The poor outcome group included five patients with intractable cholangitis and three undergoing liver transplantation who showed high postoperative liver SWE values. Liver SWE on PODs 3-7 showed ROC areas of 0.783-0.891 for predicting poor outcomes, and a cutoff value of 10.3 kPa for SWE on POD 3 had 100% (8/8) sensitivity and 73.9% (17/23) specificity. Conclusion: Preoperative liver SWE can predict advanced hepatic fibrosis, and immediate postoperative liver SWE can predict poor native liver outcomes in patients with biliary atresia.

CT Angiography-Derived RECHARGE Score Predicts Successful Percutaneous Coronary Intervention in Patients with Chronic Total Occlusion

  • Jiahui Li;Rui Wang;Christian Tesche;U. Joseph Schoepf;Jonathan T. Pannell;Yi He;Rongchong Huang;Yalei Chen;Jianan Li;Xiantao Song
    • Korean Journal of Radiology
    • /
    • v.22 no.5
    • /
    • pp.697-705
    • /
    • 2021
  • Objective: To investigate the feasibility and the accuracy of the coronary CT angiography (CCTA)-derived Registry of Crossboss and Hybrid procedures in France, the Netherlands, Belgium and United Kingdom (RECHARGE) score (RECHARGECCTA) for the prediction of procedural success and 30-minutes guidewire crossing in percutaneous coronary intervention (PCI) for chronic total occlusion (CTO). Materials and Methods: One hundred and twenty-four consecutive patients (mean age, 54 years; 79% male) with 131 CTO lesions who underwent CCTA before catheter angiography (CA) with CTO-PCI were retrospectively enrolled in this study. The RECHARGECCTA scores were calculated and compared with RECHARGECA and other CTA-based prediction scores, including Multicenter CTO Registry of Japan (J-CTO), CT Registry of CTO Revascularisation (CT-RECTOR), and Korean Multicenter CTO CT Registry (KCCT) scores. Results: The procedural success rate of the CTO-PCI procedures was 72%, and 61% of cases achieved the 30-minutes wire crossing. No significant difference was observed between the RECHARGECCTA score and the RECHARGECA score for procedural success (median 2 vs. median 2, p = 0.084). However, the RECHARGECCTA score was higher than the RECHARGECA score for the 30-minutes wire crossing (median 2 vs. median 1.5, p = 0.001). The areas under the curve (AUCs) of the RECHARGECCTA and RECHARGECA scores for predicting procedural success showed no statistical significance (0.718 vs. 0.757, p = 0.655). The sensitivity, specificity, positive predictive value, and the negative predictive value of the RECHARGECCTA scores of ≤ 2 for predictive procedural success were 78%, 60%, 43%, and 87%, respectively. The RECHARGECCTA score showed a discriminative performance that was comparable to those of the other CTA-based prediction scores (AUC = 0.718 vs. 0.665-0.717, all p > 0.05). Conclusion: The non-invasive RECHARGECCTA score performs better than the invasive determination for the prediction of the 30-minutes wire crossing of CTO-PCI. However, the RECHARGECCTA score may not replace other CTA-based prediction scores for predicting CTO-PCI success.

Evaluation of the Resolution Characteristics by Using American College of Radiology Phantom for Magnetic Resonance Imaging (자기공명영상에서 ACR 팬텀을 이용한 해상력 특성 평가)

  • Min, Jung-Whan;Jeong, Hoi-Woun;Han, Ji-Hyun;Lee, Si-Nae;Kim, Min-Ji;Kim, Seung-Chul
    • Journal of radiological science and technology
    • /
    • v.45 no.1
    • /
    • pp.11-17
    • /
    • 2022
  • This study was purpose to quantitative assessment of the resolution characteristics by using American college of radiology(ACR) phantom for magnetic resonance imaging (MRI). The MRI equipment was used (Achiva 3.0T MRI, Philips system, Netherlands) and the head/neck matrix shim SENSE head coil were 32 channels(elements) receive MR coil. And the MRI equipment was used (Discovery MR 750, 3.0T MRI, GE medical system, America) and the head/neck matrix shim MC 3003G-32R 32-CH head coil were receive MR coil. As for the modulation transfer function(MTF) comparison result by using ACR magnetic resonance imaging phantom, the MTF value of the ACR standard T2 image in GE equipment is 0.199 when the frequency is 1.0 mm-1 and the MTF value of the hospital T2 image in Philips equipment is 0.528. It was used efficiently by using a general sequence more than the standard sequence method using the ACR phantom. In addition it is significant that the quantitative quality assurance evaluation method for resolution characteristics was applied mutatis mutandis, and the result values of the physical image characteristics of the 3.0T MRI device were presented.