• Title/Summary/Keyword: Radiology science department

Search Result 2,933, Processing Time 0.028 seconds

Principal component analysis in C[11]-PIB imaging (주성분분석을 이용한 C[11]-PIB imaging 영상분석)

  • Kim, Nambeom;Shin, Gwi Soon;Ahn, Sung Min
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.12-16
    • /
    • 2015
  • Purpose Principal component analysis (PCA) is a method often used in the neuroimagre analysis as a multivariate analysis technique for describing the structure of high dimensional correlation as the structure of lower dimensional space. PCA is a statistical procedure that uses an orthogonal transformation to convert a set of observations of correlated variables into a set of values of linearly independent variables called principal components. In this study, in order to investigate the usefulness of PCA in the brain PET image analysis, we tried to analyze C[11]-PIB PET image as a representative case. Materials and Methods Nineteen subjects were included in this study (normal = 9, AD/MCI = 10). For C[11]-PIB, PET scan were acquired for 20 min starting 40 min after intravenous injection of 9.6 MBq/kg C[11]-PIB. All emission recordings were acquired with the Biograph 6 Hi-Rez (Siemens-CTI, Knoxville, TN) in three-dimensional acquisition mode. Transmission map for attenuation-correction was acquired using the CT emission scans (130 kVp, 240 mA). Standardized uptake values (SUVs) of C[11]-PIB calculated from PET/CT. In normal subjects, 3T MRI T1-weighted images were obtained to create a C[11]-PIB template. Spatial normalization and smoothing were conducted as a pre-processing for PCA using SPM8 and PCA was conducted using Matlab2012b. Results Through the PCA, we obtained linearly uncorrelated independent principal component images. Principal component images obtained through the PCA can simplify the variation of whole C[11]-PIB images into several principal components including the variation of neocortex and white matter and the variation of deep brain structure such as pons. Conclusion PCA is useful to analyze and extract the main pattern of C[11]-PIB image. PCA, as a method of multivariate analysis, might be useful for pattern recognition of neuroimages such as FDG-PET or fMRI as well as C[11]-PIB image.

  • PDF

A Survey Study of the Juvenile Idiopathic Scoliosis Using Radiation Indirect Examination (방사선 간접검사를 이용한 청소년의 척추 측만증에 관한 연구)

  • Kim, Kee-Bog;Jung, Hong-Ryang
    • Journal of radiological science and technology
    • /
    • v.28 no.4
    • /
    • pp.327-332
    • /
    • 2005
  • The purpose of this Study was to investigate the prevalence rate of idiopathic scoliosis to the students from the elementary to the university in S city of Chung-Nam using 100 mm Mirror Camera radiation indirect examination units, with on age range of between eight and thirteen (1.526 subjects), fourteen and sixteen (462 subjects), seventeen and eighteen (291 subjects), nineteen and twenty four(508 subjects) and total of 2,787 participants with the 590 male subjects and 2,197 female subjects. The results of this study can be summarized and compared the primary examination with the secondary test of greater than $10^{\circ}$of Cobb's Angle were obtained as follows; 1. Indirect Examination were conducted to find idiopathic scoliosis amomg total 2.787 subjects, 257 subjects (9.2%) who showed positive sign greater than $10^{\circ}$in the Cobb's Angle ; below age of thirteen (132 subjects), between fourteen and sixteen (52 subjects), seventeen and eighteen (35 subjects), nineteen and twenty four (38 subjects). The $x^2-test$ analysis of Indirect Examination showed no statistical significant difference association between the age range and $10^{\circ}$Cobb's Angle of spinal curve(P>0.059). 2. The numbers of idiopathic scoliosis of greater than $10^{\circ}$Cobb's Angle of spinal curve in the primary examination were observed in 147 subjects (57.2%) at the Thoracolumbar region, 81subjects (31.5%) at the Thoracic region, 20 subjects (7.8%) at the Cervicothoracic region, 7 subjects (2.7%) at the Lumbar region, 2 subjects (0.8%) at the Cervical region. So, the large numbers were Thoracolumbar region, 183 participants (71.2%) showed the right side curve of scoliosis and 74 participant (28.8%) showed the left side curve of scoliosis. 3. The main region of the pain in one's own self more than $10^{\circ}$ Cobb's angle of spinal curve were no pain 219 subjects (85.2%), 18 subjects (7.0%) at the Lumbar region, 9 subjects (3.5%) at the Cervical region, 7 subjects (2.7%) at the Thoracic region, 2 subjects (0.7%) at the shoulder girdle region, 1 subjects (0.39%) at the pelvis and whole body region. There was statistical significant difference association between the Cobb's Angle of spinal curve and the main pain region of one's (P<0.006). This study may be significant to an early stage investigate of the prevalence rate of idiopathic scoliosis in the juveniles using 100 mm Mirror Camera radiation indirect examination units. The results of this study help that the students in a stage on growth the basis of data early discovery and therapy of idiopathic scoliosis.

  • PDF

Quality of Life in Chungcheong area University Students according to their Sensory Processing Intervention (충청권 대학생의 감각처리 중재 후 삶의 질)

  • Lee, Ji-Hyun;Lee, Tae-Yong;Kim, Young-Ran
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.6
    • /
    • pp.81-88
    • /
    • 2016
  • This research investigated the sensory processing ability and selected subjects who had sensory processing problems, and divided the subjects into an experimental group and control group. The experimental group was educated with sensory processing intervention on the activities of daily living to determine its influence on the quality of life. The study was based on 230 university students with similar majors in 3 universities of Chungcheong area in the beginning of May, 2013. From here, 32 subjects who had issues with their sensory processing ability were selected. The 230 students were given a survey on the quality of life, individual characteristics, and sensory processing ability. Later, the 32 subjects who had problems with their sensory processing ability were divided into an experimental group and control group. The control group performed sensory processing intervention, whereas the control group did not. After the sensory processing intervention method for 6 weeks, the quality of life was re-evaluated. As a result, the total score of the quality of life after intervention was 98.69 in the experimental group and 84.81 in the control group (p=0.001). The physical score was 16.43 in the experimental group and 14.64 in the control group (p=0.008). The psychological score was 14.71 in the experimental group and 11.75 in the control group (p<0.001). The social score was 14.67 in the experimental group and 13.17 in the control group (p=0.032). The environment score was 14.66 in the experimental group and 12.34 in the control group (p=0.006). The experimental group showed a significant increase in all areas of the quality of life, whereas the control group did not. Through this result, it can be seen that a sensory processing intervention method in daily life can increase the quality of life for subjects with problems in sensory processing ability. Overall, it will be necessary to apply a treatment of various sensory intervention programs for adults and promote a better quality of life.

Reliability and Validity of the Fatigue Severity Scale among University Student in South Korea (대학교 재학생에서 Fatigue Severity Scale의 신뢰도 및 타당도 연구)

  • Lee, Junghyun H.;Jeong, Hyeonseok S.;Lim, Soo Mee;Cho, Han Byul;Ma, Ji-Young;Ko, Eun;Im, Jooyeon J.;Lee, Sun Hea;Bae, Sujin;Lee, Yu-Jin;Lyoo, In Kyoon;Jeong, Do-Un
    • Korean Journal of Biological Psychiatry
    • /
    • v.20 no.1
    • /
    • pp.6-11
    • /
    • 2013
  • Objectives There are only a limited number of studies on instruments assessing fatigue in university students, although fatigue exerts negative influences on their health and academic performances and fatigue-related complaints are more frequently reported in young adults than middle-aged adults. The aim of this study was to validate the 9-item Fatigue Severity Scale (FSS) among university students including both undergraduate and graduate students in South Korea. Methods A total of 176 university students completed a battery of self-report questionnaires, including the FSS, the Brief Fatigue Inventory (BFI), the Beck Depression Inventory-II (BDI-II), the Beck Anxiety Inventory (BAI), the Medical Outcomes Study Short Form 36 version 2 (MOS-SF36v2), and the Inclusion of Community in the Self Scale (ICS). The data were collected from February of 2012 to June of 2012. The reliability, convergent validity, divergent validity, and exploratory factor analyses were conducted to assess psychometric properties of the FSS. Results The mean FSS score was 3.20 (standard deviation = 1.43). The FSS demonstrated an excellent internal consistency (Cronbach's ${\alpha}$ = 0.93) and item-total correlations ranged from 0.56 to 0.90. Correlations of the FSS with the BFI (r = 0.71, p < 0.01), BDI-II (r = 0.54, p < 0.01), BAI (r = 0.46, p < 0.01), MOS-SF36v2 physical component summary (r = -0.28, p < 0.01), MOS-SF36v2 mental component summary (r = -0.55, p < 0.01), and ICS (Spearman's rho = -0.07, p = 0.33) showed acceptable convergent and divergent validity. Exploratory factor analysis defined one underlying factor (eigenvalue = 5.67) that explained 93.50% of the total variance. Conclusions To the best of our knowledge, this is the first study to investigate reliability and validity of the FSS in university students. The FSS exhibits good psychometric properties for evaluation of fatigue among university students in South Korea. Since the FSS is easy to administer, score, and interpret, it could be a useful tool in research and practice for assessing fatigue among university students.

Association of Metabolic Syndrome and Biochemical Examination of the Gallbladder Polyp (담낭 용종의 대사성 증후군 및 생화학적 검사의 연관성)

  • Park, Young-Joon
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.267-276
    • /
    • 2015
  • The gallbladder(GB) polyps have malignant potential and nowadays are increasing due to the extended use of ultrasonography. Even though there are various reports on the risk of GB polyps, there is few study on the relationship between the presence of metabolic syndrome including serum biochemistry, lifestyle and the development of gallbladder polyps in korean population. The aim of this study is to establish a relationship between the presence of metabolic syndrome including serum biochemistry and the development of gallbladder polyps in korean population. This study conducted on 151 men and 167 women who visited a musculoskeletal hospital in Gyeonggido to have an ultrasound scan of the abdomen from November 2, 2012 to January 31, 2014. They are randomly selected to evaluate the prevalence risk factors were analyzed by comparing various variables between the GB polyp positive and negative. The collected data were analyzed using the personal computer program SPSS version 20.0 for windows. The mean size of the GB polyps was 3.92mm in diameter. Size of GB polyps were less than 10mm in diameter. As to frequency in the people with the GB polyps, the number of patients with the GB polyps was 184(57.9%): the number of metabolic syndrome of them was 114(26.4%); these results showed that risk of the GB polyps got higher at patients with metabolic syndrome. As to the risk of the GB polyps, people with the GB polyps had significantly higher risk than those without the GB polyps, as follows: The risk was significantly 1.061 times higher by weight; 1.186 by BMI; 1.060 by systolic blood pressure; 1.030 by diastolic blood pressure; 1,009 by Total cholesterol; 2.736 by metabolic syndrome; 1.011 by blood sugar on an empty stomach; 1.064 by ESR. The risk factors of GB polyps were found to be weight, BMI, total cholesterol, Triglycerol, Glucose, systolic blood pressure, diastolic blood pressure, ESR and metabolic syndrome. This study has a possibility to be used an indicator to identify the GB polyps, and in the future larger-scale study will have to be conducted to objectify it.

Radiation Exposure Dose on Persons Engaged in Radiation-related Industries in Korea (한국에서 방사선 관련 종사자들의 개인피폭선량 실태에 관한 연구)

  • Lim, Bong-Sik
    • Journal of radiological science and technology
    • /
    • v.29 no.3
    • /
    • pp.185-195
    • /
    • 2006
  • Purpose: This study investigated the status of radiation exposure doses since the establishment of the "Regulations on Safety Management of Diagnostic Radiation Generation Device" in January 6, 1995. Method: The level of radiation exposure in people engaged or having been engaged in radiation-related industries of inspection organizations, educational organizations, military units, hospitals, public health centers, businesses, research organizations or clinics over a 5 year period from Jan. 1, 2000 to Dec. 31, 2004 was measured. The 149,205 measurement data of 57,136 workers registered in a measurement organization were analysed in this study. Frequency analysis, a Chi-square test, Chi-square trend test, and ANOVA was used for data analysis. Results: Among 57,136, men were 40,870(71.5%). 50.3% of them were radiologic technologists, otherwise medical doctors(22.7%), nurse(2.9%) and others(24.1%). The average of depth radiation and surface radiation during the 5-year period were found to decrease each year. Both the depth radiation and surface radiation exposure were significantly higher in males, in older age groups, in radiological technologists of occupation. The departments of nuclear medicine had the highest exposure of both depth and surface radiation of the divisions of labor. There were 1.98 and 2.57 per 1,000 person-year were exposed more than 20 mSv(limit recommended by International Commission on Radiological Protection) in depth and surface radiation consequently. Conclusion: The total exposure per worker was siginifcantly decreased by year. But Careful awareness is needed for the workers who exposed over 20 mSv per year. In order to minimize exposure to radiation, each person engaged in a radiation-related industry must adhere to the individual safety management guidelines more thoroughly. In addition, systematic education and continuous guidance aimed at increasing the awareness of safety must be provided.

  • PDF

The Assessment of the Breath Hold and the Free Breath Methods about the Blood Flow Evaluation by Using Phase Contrast MRI (위상대조도 자기공명영상을 이용한 심장 혈류평가에 있어서 호흡정지 기법과 비 호흡정지 기법의 비교평가)

  • Kim, Seong-Ho
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.149-156
    • /
    • 2016
  • Measurement of cardiac blood flow using the magnetic resonance imaging has been limited due to breathing and involuntary movements of the heart. The present study attempted to improve the accuracy of cardiac blood flow testing through phase contrast magnetic resonance imaging by presenting the adequate breathing method and imaging variables by comparing the measurement values of cardiac blood flow. Each was evaluated by comparing the breath hold retrospective 1NEX and non breath hold retrospective 1-3NEX in the ascending aorta and descending aorta. As a result, the average blood flow amount/velocity of the breath hold retrosepctive 1NEX method in the ascending aorta were $96.17{\pm}19.12ml/sec$, $17.04{\pm}4.12cm/sec$ respectively, which demonstrates a statistically significant difference(p<0.05) with the non-breath hold retrospective method 1NEX of $72.31{\pm}13.27ml$ and $12.32{\pm}3.85$. On the other hand, the average 2NEX blood flow and mean flow velocity is $101.90{\pm}24.09$, $16.84{\pm}4.32$, 3NEX $103.06{\pm}25.49$, $16.88{\pm}4.19$ did not show statistically significant differences(p>0.05).The average blood flow amount/ velocity of the breath hold retrospective 1NEX method in the descending aorta were $76.68{\pm}19.72ml/s$, and $22.23{\pm}4.8$, which did not demonstrate a significant difference in comparison to non-breath hold retrospective method 1-3 NEX. Therefore, the non breath hold retrospective method does not significantly differ in terms of cardiac blood flow in comparison with the breath hold retrospective method in accordance with the increase of NEX, so pediatric patients or patients who are not able to breathe well must have the diagnostic value of their cardiac blood flow tests improved.

The Radioprotective Effects of Grifola umbellata Hot Water Extract on Mice (저령(Grifola umbellata)의 열수 추출물이 생쥐에 미치는 방사선 방호 효과)

  • Park, Jun-Chul
    • Journal of radiological science and technology
    • /
    • v.28 no.4
    • /
    • pp.333-340
    • /
    • 2005
  • In this study, the radioprotective effects of Grifola umbellata hot water extracts (Gu-extract) on mice were investigated. Single pre-administration of Gu-extract increased the 40-day survival ratio of irradiated mice from 65.5% to 78.6%. The growth of 3 week old male mice in the irradiated group was slightly retarded as compared to those of the control and Gu-extract treated mice. The average spleen and thymus weights of the irradiated mice were lower than those of the control and Gu-extract treated mice. The weight reduction of testis in the irradiated mice was significant. While it was relatively slight in the Gu-extract treated mice as compared to that of control mice. No significant difference in the weight was observed in heart, kidney or liver among three groups. The leukocytes of the Gu-extract treated mice did not decrease dramatically as in the irradiated group, but recovery patterns were similar in both groups. Reduction of erythrocytes were similar in both groups but its recovery occurred more rapidly in the extract treated group. The glucose level of the Gu-extract treated group did not change during the period examined, while it was still higher in the irradiated group than the level in the control group in two weeks. The cholesterol levels in the irradiated and the Gu-extract treated groups were higher than that of control group on day 7, but decreased to the level of the control group on day 14. No difference was observed in total protein amount of the serum among the three groups. SDS-polyacrylamide gel electrophoresis of the soluble proteins extracted from various organs did not reveal differences to any extent in all groups except in the livers of the irradiated and extract treated groups, in which some proteins were missing or less present.

  • PDF

The Satisfaction Survey of Users and Patients on the Developed Disposable Tourniquet (개발한 일회용 지혈대의 사용자 및 환자 만족도 조사)

  • Kim, Sang-Hyun
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.615-622
    • /
    • 2016
  • The 18~20G needle is used to computer tomography (CT) contrast examination. Therefore, a patient has to apply a self-administering hemostasis (conventional method: CM) and often experience bleeding in the course. Thus, we developed the new disposable transparent tourniquet (TT) for reducing. This study was to compare the usefulness between the proposed transparent tourniquet and the existing hemostatic methods. A Satisfaction survey was conducted by 50 patients and 25nurses. The survey contained the satisfaction of the convenience, safety, sanitation, and wearing sensation of transparent tourniquet. We employed face-to-face interview on 5 points likert scales. And Chi-square, paired T-test were used for the statistics verification. As for the patients, the satisfaction levels were measured for each category with the gender, age. Patients evaluation, overall satisfaction high average sore used TT and there were statistical significance by paired T-test(p<0.05). The following is the average satisfaction level for each category: $4.4{\pm}0.53$ in; $4.28{\pm}0.57$ in safety; $4.52{\pm}0.54$ in sanitation; $4.16{\pm}0.54$ in wearing sensation. So the overall satisfaction level is measured at $4.34{\pm}0.51$. As for the nurses, CT work experience and the current satisfaction with tourniquet were counted as variables. The satisfaction level for each category is: $3.8{\pm}0.7$ in; $3.6{\pm}0.68$ in safety; $3.4{\pm}0.5$ in sanitation; $3.9{\pm}0.49$ in hemostasis. The overall satisfaction level is $3.8{\pm}0.3$. Patients' satisfaction levels were very high with little difference among variables. Nurses' satisfaction levels were different with the TT depending on their work experience but their overall satisfaction was high. This TT will be a starting point to minimizing patient's inconvenience and more studies are necessary to enhance their satisfaction.

Correlation analysis of radiation therapy position and dose factors for left breast cancer (좌측 유방암의 방사선치료 자세와 선량인자의 상관관계 분석)

  • Jeon, Jaewan;Park, Cheolwoo;Hong, Jongsu;Jin, Seongjin;Kang, Junghun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.1
    • /
    • pp.37-48
    • /
    • 2017
  • Purpose: The most basic conditions of radiation therapy is to prevent unnecessary exposure of normal tissue. The risk factors that are important o evaluate the dose emitted to the lung and heart from radiation therapy for breast cancer. Therefore, comparing the dose factors of a normal tissue according to the radion treatment position and Seeking an effective radiation treatment for breast cancer through the analysis of the correlation relationship. Materials and Methods: Computed tomography was conducted among 30 patients with left breast cancer in supine and prone position. Eclipse Treatment Planning System (Ver.11) was established by computerized treatment planning. Using the DVH compared the incident dose to normal tissue by position. Based on the result, Using the SPSS (ver.18) analyzed the dose in each normal tissue factors and Through the correlation analysis between variables, independent sample test examined the association. Finally The HI, CI value were compared Using the MIRADA RTx (ver. ad 1.6) in the supine, prone position Results: The results of computerized treatment planning of breast cancer in the supine position were V20, $16.5{\pm}2.6%$ and V30, $13.8{\pm}2.2%$ and Mean dose, $779.1{\pm}135.9cGy$ (absolute value). In the prone position it showed in the order $3.1{\pm}2.2%$, $1.8{\pm}1.7%$, $241.4{\pm}138.3cGy$. The prone position showed overall a lower dose. The average radiation dose 537.7 cGy less was exposured. In the case of heart, it showed that V30, $8.1{\pm}2.6%$ and $5.1{\pm}2.5%$, Mean dose, $594.9{\pm}225.3$ and $408{\pm}183.6cGy$ in the order supine, prone position. Results of statistical analysis, Cronbach's Alpha value of reliability analysis index is 0.563. The results of the correlation analysis between variables, position and dose factors of lung is about 0.89 or more, Which means a high correlation. For the heart, on the other hand it is less correlated to V30 (0.488), mean dose (0.418). Finally The results of independent samples t-test, position and dose factors of lung and heart were significantly higher in both the confidence level of 99 %. Conclusion: Radiation therapy is currently being developed state-of-the-art linear accelerator and a variety of treatment plan technology. The basic premise of the development think normal tissue protection around PTV. Of course, if you treat a breast cancer patient is in the prone position it take a lot of time and reproducibility of set-up problems. Nevertheless, As shown in the experiment results it is possible to reduce the dose to enter the lungs and the heart from the prone position. In conclusion, if a sufficient treatment time in the prone position and place correct confirmation will be more effective when the radiation treatment to patient.

  • PDF