• Title/Summary/Keyword: Radiology science department

Search Result 2,933, Processing Time 0.038 seconds

A modified device for intraoral radiography to assess the distal osseous defects of mandibular second molar after impacted third molar surgery

  • Ana, Faria-Inocencio;Mercedes, Gallas-Torreira
    • Imaging Science in Dentistry
    • /
    • v.41 no.3
    • /
    • pp.115-121
    • /
    • 2011
  • Purpose : This article is to describe a modified device for intraoral radiography which was developed to obtain reproducible radiographic images for assessment of distal osseous defects of the mandibular second molar (2 Mm) after impacted third molar (3 Mm) surgery. Materials and Methods : A commercial available alignment system for posterior region was modified by adding a reference gauge pin (millimetric) and threading a hollow acrylic cylinder at the ring of the radiographic positioner to attach the X-ray collimator. The design included customized resin acrylic stent for the occlusal surface of the 2Mm in maximum intercuspal position, individualizing the biteblock positioner. Periapical radiographs were taken before and after surgical extraction of 3 Mm, employing the radiographic technique of parallelism described by Kugelberg (1986) with this modified film holder and inserting the gauge pin on the deepest bone probing depth point. Results : This technique permitted to obtain standardized periapical radiographs with a moderate to high resolution, repeatability, and accuracy. There was no difference between the measurements on the pre- and post-operative radiographs. This technique allowed better maintenance of the same geometric position compared with conventional one. The insertion of the gauge pin provided the same reference point and localized the deepest osseous defect on the two-dimensional radiographs. Conclusion : This technique allowed better reproducibility in posterior radiographic records (distal surface of 2 Mm) and more accurate measurements of radiographic bone level by the use of a millimetric pin.

Fractal analysis of the surgical treatment of ligature-induced peri-implantitis in dogs (임플란트 주위염 치료 효과의 프랙탈 분석)

  • Kim, Hak-Kun;Kim, Jin-Soo
    • Imaging Science in Dentistry
    • /
    • v.40 no.3
    • /
    • pp.123-129
    • /
    • 2010
  • Purpose : To evaluate the effect of surgical treatment of ligature-induced peri-implantitis in dogs using fractal analysis. Also, the capabilities of fractal analysis as bone analysis techniques were compared with those of histomorphometric analysis. Materials and Methods : A total of 24 implants were inserted in 6 dogs. After a 3-months, experimental periimplantitis characterized by a bone loss of about 3 mm was established by inducing with wires. Surgical treatment involving flap procedure, debridement of implants surface with chlorhexidine and saline (group 1), guided bone regeneration (GBR) with absorbable collagen membrane and mineralized bone graft (group 2), and $CO_2$ laser application with GBR (group 3) were performed. After animals were sacrificed in 8 and 16 weeks respectively, bone sections including implants were made. Fractal dimensions were calculated by box-counting method on the skeletonized images, made from each region of interest, including five screws at medial and distal aspects of implant, were selected. Results : Statistically significant differences in the fractal dimensions between the group 1($0.9340{\pm}0.0126$) and group 3($0.9783{\pm}0.0118$) at 16 weeks were found (P<0.05). The fractal dimension was statistically significant different between 8($0.9395{\pm}0.0283$) and 16 weeks in group 3 (P<0.05). These results were similar with the result of the evaluation of new bone formation in histomorphometric analysis. Conclusions : Treatment of experimental peri-implantitis by using $CO_2$ laser with GBR is more useful than other treatments in the formation of new bone and also the tendency of fractal dimension to increase relative to healing time may be a useful means of evaluating.

Assessing Correlation between Two Variables in Repeated Measurements using Mixed Effect Models (혼합모형을 이용한 반복 측정된 변수들 간의 상관분석)

  • Han, Kyunghwa;Jung, Inkyung
    • The Korean Journal of Applied Statistics
    • /
    • v.28 no.2
    • /
    • pp.201-210
    • /
    • 2015
  • Repeated measurements on each variables of interest often arise in bioscience or medical research. We need to account for correlations among repeated measurements to assess the correlation between two variables in the presence of replication. This paper reviews methods to estimate a correlation coefficient between two variables in repeated measurements using the variance-covariance matrix of linear mixed effect models. We analyze acoustic radiation force impulse imaging (ARFI) data to assess correlation between three shear wave velocity (SWV) measurements in liver or spleen and spleen length by ultrasonography. We present how to obtain parameter estimates for the variance-covariance matrix and correlations in mixed effects models using PROC MIXED in SAS.

Convergence Study on Diagnostic Agreement between Occurrence of Osteoporosis and Doctor's Diagnosis of Osteoporosis (골다공증 유무와 골다공증 의사진단여부와의 진단 일치율 융합연구)

  • Kim, Young-Ran;Park, Chang-Soo
    • Journal of Digital Convergence
    • /
    • v.17 no.1
    • /
    • pp.281-286
    • /
    • 2019
  • This study, which checked diagnostic agreement at the femoral region and lumbar region during diagnosis of osteoporosis and surveyed errors related with choosing measured parts, aimed at providing basic date for right diagnosis of osteoporosis. The study, using the first, second years of the fifth period from initial data from National Nutrition Survey, surveyed 1,637 men and 2,128 women at the age of 50 years or older. The study used kappa test to grasp the agreement between the occurrence of osteoporosis at the femoral region and lumbar region and whether or not received doctor's diagnosis. Women showed diagnostic agreement of osteoporosis at all of the femoral region and lumbar region, with diagnostic agreement of the lumbar region being higher than that of the femoral region. While, men showed diagnostic agreement of osteoporosis only at the lumbar region. Bone density changes with the age and varies depending on parts, and so, the study believes, measuring bone density should conduct all of the femoral region and lumbar region and diagnosis had better be made focused on the lumbar region.

Photoacoustic imaging of occlusal incipient caries in the visible and near-infrared range

  • da Silva, Evair Josino;de Miranda, Erica Muniz;de Oliveira Mota, Claudia Cristina Brainer;Das, Avishek;Gomes, Anderson Stevens Leonidas
    • Imaging Science in Dentistry
    • /
    • v.51 no.2
    • /
    • pp.107-115
    • /
    • 2021
  • Purpose: This study aimed to demonstrate the presence of dental caries through a photoacoustic imaging system with visible and near-infrared wavelengths, highlighting the differences between the 2 spectral regions. The depth at which carious tissue could be detected was also verified. Materials and Methods: Fifteen permanent molars were selected and classified as being sound or having incipient or advanced caries by visual inspection, radiography, and optical coherence tomography analysis prior to photoacoustic scanning. A photoacoustic imaging system operating with a nanosecond pulsed laser as the light excitation source at either 532 nm or 1064 nm and an acoustic transducer at 5 MHz was developed, characterized, and used. En-face and lateral(depth) photoacoustic signals were detected. Results: The results confirmed the potential of the photoacoustic method to detect caries. At both wavelengths, photoacoustic imaging effectively detected incipient and advanced caries. The reconstructed photoacoustic images confirmed that a higher intensity of the photoacoustic signal could be observed in regions with lesions, while sound surfaces showed much less photoacoustic signal. Photoacoustic signals at depths up to 4 mm at both 532 nm and 1064 nm were measured. Conclusion: The results presented here are promising and corroborate that photoacoustic imaging can be applied as a diagnostic tool in caries research. New studies should focus on developing a clinical model of photoacoustic imaging applications in dentistry, including soft tissues. The use of inexpensive light-emitting diodes together with a miniaturized detector will make photoacoustic imaging systems more flexible, user-friendly, and technologically viable.

Tomographic sagittal root position in relation to maxillary anterior bone housing in a Brazilian population

  • Rodrigues, Diogo Moreira;Petersen, Rodrigo Lima;Montez, Caroline;Barboza, Eliane Porto
    • Imaging Science in Dentistry
    • /
    • v.52 no.1
    • /
    • pp.75-82
    • /
    • 2022
  • Purpose: This cross-sectional study evaluated and categorized the tomographic sagittal root position (SRP) of the maxillary anterior teeth in a Brazilian population. Materials and Methods: Cone-beam computed tomographic scans of 420 maxillary anterior teeth of 70 patients (35 men and 35 women, mean age 25.2±5.9 years) were evaluated. The SRP was classified as class I, II, III, or IV. In class I, the root is positioned against the buccal cortical plate; in class II, the root is centered in the middle of the alveolar housing; in class III, the root is positioned against the palatal cortical plate; and in class IV, at least two-thirds of the root engage both the buccal and palatal cortical plates. Results: In total, 274 teeth (65.2%) were class I, 39 (9.3%) were class II, 3 (0.7%) were class III, and 104 (24.8%) were class IV. The frequency distribution over the teeth groups was different from the overall analysis. Important differences were found in the frequencies of classes I, II, and IV compared to other populations. Sex was not associated with the SRP classes (P=0.307). Age distribution was significantly different over the classes (P=0.004). Conclusion: The findings of this study on the distribution of SRP classes among the Brazilian population compared to other populations demonstrate that the SRP should be analyzed on a case-by-case basis for an accurate treatment plan in the maxillary anterior area.

Intraoral scanning of the edentulous jaw without additional markers: An in vivo validation study on scanning precision and registration of an intraoral scan with a cone-beam computed tomography scan

  • Julie Tilly Deferm;Frank Baan;Johan Nijsink;Luc Verhamme;Thomas Maal;Gert Meijer
    • Imaging Science in Dentistry
    • /
    • v.53 no.1
    • /
    • pp.21-26
    • /
    • 2023
  • Purpose: A fully digital approach to oral prosthodontic rehabilitation requires the possibility of combining (i.e., registering) digital documentation from different sources. This becomes more complex in an edentulous jaw, as fixed dental markers to perform reliable registration are lacking. This validation study aimed to evaluate the reproducibility of 1) intraoral scanning and 2) soft tissue-based registration of an intraoral scan with a cone-beam computed tomography (CBCT) scan for a fully edentulous upper jaw. Materials and Methods: Two observers independently performed intraoral scans of the upper jaw in 14 fully edentulous patients. The palatal vault of both surface models was aligned, and the inter-observer variability was assessed by calculating the mean inter-surface distance at the level of the alveolar crest. Additionally, a CBCT scan of all patients was obtained and a soft tissue surface model was generated using patient-specific gray values. This CBCT soft tissue model was registered with the intraoral scans of both observers, and the intraclass correlation coefficient(ICC) was calculated to evaluate the reproducibility of the registration method. Results: The mean inter-observer deviation when performing an intraoral scan of the fully edentulous upper jaw was 0.10±0.09 mm. The inter-observer agreement for the soft tissue-based registration method was excellent(ICC=0.94; 95% confidence interval, 0.81-0.98). Conclusion: Even when teeth are lacking, intraoral scanning of the jaw and soft tissue-based registration of an intraoral scan with a CBCT scan can be performed with a high degree of precision.

Cephalometric evaluation of skeletal stability and pharyngeal airway changes after mandibular setback surgery: Bioabsorbable versus titanium plate and screw fixation

  • Phu Hnin Thet;Boosana Kaboosaya
    • Imaging Science in Dentistry
    • /
    • v.54 no.2
    • /
    • pp.181-190
    • /
    • 2024
  • Purpose: This study compared sequential changes in skeletal stability and the pharyngeal airway following mandibular setback surgery involving fixation with either a titanium or a bioabsorbable plate and screws. Materials and Methods: Twenty-eight patients with mandibular prognathism undergoing bilateral sagittal split osteotomy by titanium or bioabsorbable fixation were randomly selected in this study. Lateral cephalometric analysis was conducted preoperatively and at 1 week, 3-6 months, and 1 year postoperatively. Mandibular stability was assessed by examining horizontal (BX), vertical (BY), and angular measurements including the sella-nasion to point B angle and the mandibular plane angle (MPA). Pharyngeal airway changes were evaluated by analyzing the nasopharynx, uvula-pharynx, tongue-pharynx, and epiglottis-pharynx (EOP) distances. Mandibular and pharyngeal airway changes were examined sequentially. To evaluate postoperative changes within groups, the Wilcoxon signed-rank test was employed, while the Mann-Whitney U test was used for between-group comparisons. Immediate postoperative changes in the airway were correlated to surgical movements using the Spearman rank test. Results: Significant changes in the MPA were observed in both the titanium and bioabsorbable groups at 3-6 months post-surgery, with significance persisting in the bioabsorbable group at 1 year postoperatively (2.29°±2.28°; P<0.05). The bioabsorbable group also exhibited significant EOP changes (-1.21±1.54 mm; P<0.05) at 3-6 months, which gradually returned to non-significant levels by 1 year postoperatively. Conclusion: Osteofixation using bioabsorbable plates and screws is comparable to that achieved with titanium in long-term skeletal stability and maintaining pharyngeal airway dimensions. However, a tendency for relapse exists, especially regarding the MPA.

Prediction of High Grade Vesicoureteral Reflux in Infants Less than 3 Months with Urinary Tract Infection (3개월 미만 요로감염 영아에서 중증 방광 요관 역류의 예측인자)

  • Yi, Dae-Yong;Kim, Na-Yeon;Cho, Hee-Yeon;Kim, Ji-Eun;Sim, So-Yeon;Son, Dong-Woo;Jeon, In-Sang;Cha, Han
    • Childhood Kidney Diseases
    • /
    • v.12 no.2
    • /
    • pp.178-185
    • /
    • 2008
  • Purpose : Our aim was to investigate the predictive factors for detecting grade III-V vesicoureteral reflux(VUR) in young infants less than 3 months with urinary tract infections (UTI). Methods : Data of infants who underwent ultrasonography and VCUG between January 2004 and September 2007 were reviewed. Age, gender, incidence of bacteremia, C-reactive protein(CRP) and imaging studies were compared between group I(grade III-V VUR) and group II (normal or grade I and II VUR) retrospectively. Sensitivity, specificity, positive and negative predictive values, odds ratio, and likelihood ratio of ultrasonography for high grade VUR were evaluated. Results : Among 54 enrolled infants(41 males, 13 females), 14 infants were group I and 40 infants were group II. In the group I, CRP level was significantly higher(6.11$\pm$5.18 vs. 3.27$\pm$3.45, P=0.025), and there were more ultrasonographic abnormal findings(71.4%, vs. 22.5%, P=0.002) compared with group II. However, ultrasonography was the only significant factor after adjusting with logistic regression(P=0.002). Incidence of bacteremia and abnormal DMSA findings were not significantly different in two groups. Sensitivity, specificity, and odds ratio of ultrasonography was 71.4%, 77.5%, 6.9 respectively. Negative predictive value was 88.6% and negative likelihood ratio was 0.37. Ultrasonography had significant negative likelihood ratio for grade III-V VUR, but missed 4 infants with grade III VUR. Conclusion : We could not find any alternative predictive factors to reduce VCUG in detecting high grade VUR. Therefore, VCUG must be considered in young infants less than 3 months with UTI.

THREE DIMENSIONAL LINEAR MEASUREMENT OF PROXIMAL TIBIA IN MEDIAL AND LATERAL APPROACH FOR BONE HARVESTING (경골 근위부 골채취를 위한 내측 및 외측 접근법시의 삼차원적 길이계측)

  • Nam, Woong;Park, Won-Se;Jeong, Ho-Gul;Hu, Kyung-Seok;Cha, In-Ho
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.33 no.4
    • /
    • pp.307-311
    • /
    • 2007
  • Purpose: The aim of this study was simply assessing linear measurements in the lateral and medial approach, respectively, for bone harvesting using anatomic and three-dimensional(3D) computed tomographic(CT) analyses on a dried cadaveric proximal tibia. In addition, the availability of the three-dimensional computed tomographic(3D-CT) analysis was also estimated. Materials and methods: Ten dried proximal tibia were obtained from five Korean cadavers. Four the reference points, the SM(superior-medial), IM(inferior-medial), SL(superior-lateral), and IL(inferior-lateral) were marked around the tibial tuberosity. The PM(posterior-medial) and PL(posterior-lateral) points were randomly marked at points farthest from the lateral and medial reference points, respectively, in the posterior border of the superior articular surface of both condyles. All measurements were obtained on the dried proximal tibia. After computed tomography had been performed, the three dimensional images were reconstructed using V works $4.0^{TM}$(Cybermed Inc., Seoul, Korea), and the length between the reference points were measured three dimensionally using the method described above. The error between the mean actual and mean 3D-CT measurements was calculated in order to determine the availability of the three dimensional computed tomographic analysis. Results: The length between the reference points was greatest at the IL-PM, which averaged $65.39mm{\pm}10.35$. This was followed by the SL-PM with $63.24mm{\pm}8.10$, the IM-PL with $58.09mm{\pm}10.02$, and the SM-PL with $51.99mm{\pm}9.06$. The differences between the IL-PM and SM-PL were 13.4 mm. The mean values were 55.04 mm in the medial approach and 64.32 mm in the lateral approach, and the differences between medial and lateral were 9.28 mm. The error between the mean actual and mean 3D-CT measurements was 0.31% and the standard deviation was 0.28%. Conclusion: The anatomical and three dimensional computed tomographic analysis indicates that there was only a 9.28 mm linear difference between the lateral and medial approach. This is consistent with previous studies, which showed that there was little difference between the two approaches in terms of the bone volume. In addition, the error(0.31%) and the standard deviation(0.28%) were considered low, demonstrating high accuracy of 3D-CT. Therefore it can be used in preoperative treatment planning.