• Title/Summary/Keyword: Radiology science department

Search Result 2,933, Processing Time 0.029 seconds

Analysis Perceptions of Intravenous Injection Behavior of Contrast Medium in Radiological Technologists' Task (방사선사 직무에서 조영제 정맥 주입 행위에 대한 인식도 분석)

  • Jung-Ho Kang;Youl-Hun Seoung
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.1
    • /
    • pp.53-63
    • /
    • 2024
  • The purpose of this study was to analyze radiological technologists' (RT) task perceptions of intravenous injection behavior of contrast medium and use it as basic data for future workforce response plans. We surveyed a total of 172 RT using questionnaire terms consisting of demographic characteristics, job priorities, and RT' task perceptions of intravenous injection behavior. Statistical analysis was performed using descriptive statistics, frequency analysis, independent samples T-test, and ANOVA analysis. As a result, first, current clinical RT were highly aware of the need for intravenous injection behavior as a response to the future workforce of them, and the workload burden resulting from this was evaluated as low. Second, the fear of intravenous injection behavior was found to be significant, so it is judged to be useful to perform them as selective job actions rather than all RT' task. Third, the need for training courses and certification for RT' intravenous injection behavior is being raised, and additional specific research on this is required. Last, RT' positive perception of intravenous injection behavior could be expected as a foundation for improving national medical services, strengthening RT expertise, and expanding tasks.

Development of Elbow Joint X-ray Examination Aid for Medical Imaging Diagnosis (의료영상 진단을 위한 팔꿉관절 X-선 검사 보조기구 개발)

  • Hyeong-Gyun Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.2
    • /
    • pp.127-133
    • /
    • 2024
  • The elbow joint is made up of three different bones. X-rays or other radiological exams are commonly used to diagnose elbow injuries or disorders caused by physical activity and external forces. Previous research on the elbow joint reported a new examination method that meets the imaging evaluation criteria in the tilt position by Z-axis elevation of the forearm. Therefore, this study aims to design an optimized instrument and develop an aid applicable to other upper extremity exams. After completing the 2D drawing and 3D modeling design, the final design divided into four parts was fabricated with a 3D printer using ABS plastic and assembled. The developed examination aid consists of a four-stage Z-axis elevation tilt angle function (0°, 5°, 10°, and 15°) and can rotate and fixate 360° in 1-degree increments. It was designed to withstand a maximum equivalent stress of 56.107 Pa and a displacement of 1.6548e-5 mm through structural analysis to address loading issues caused by cumulative frequency of use and physical utilization. In addition to X-ray exams of the elbow joint, the developed aid can be used for shoulder function tests by rotating the humerus and also be applied to MRI and CT exams as it is made of non-metallic materials. It will contribute to the accuracy and efficiency of medical imaging diagnosis through clinical applications of various devices and medical imaging exams in the future.

Evaluation of Usefulness of Assertive Devices to Improve the Accuracy in Skull lateral X-ray Projection (두개골 측방향 X-선 촬영에서 정확도 향상을 위한 촬영 보조 기구의 유용성 평가)

  • Bo-Seok Chang
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.2
    • /
    • pp.153-159
    • /
    • 2024
  • In X-ray projection, Unskilled radiologists become skilled through fail exam. This causes the patient to be exposed to unnecessary radiation. In this study, pre-position unskilled radiologic technologist presented ways to improve clinical proficiency. presented a skull lateral x-ray projection practice method using visual, spatial, and assistive devices. In addition, the accuracy and usefulness of the use of assistive devices were evaluated. When X-ray images were taken based on learning, the rotational spacing, which indicates image distortion, was 7.85 ± 1.45 mm and the tiliting spacing was 4.84 ± 0.5 mm. When practicing using visual aids, the rotational spacing is 4.4 ± 0.76 mm and the inclination spacing is 3.01 ± 0.87 mm. using a spatial compensation device, the rotational spacing is 5.2 ± 0.69 mm and the tiliting spacing is 3.33 ± 0.61 mm. Skull lateral X-ray Image distortion caused by empirical photography practice decreased by 5.4%, but image distortion caused by tilting increased by 1.2%. When practicing using a visual assistive devices, the degree of rotational spacing by 40.1% and the tiliting spacing decreased by 30.7% compared to the empirical x-ray exposure practice. When using spatial assistive devices, the rotation interval was reduced by 41.7% and the tilting interval by 23.7% compared to conventional empirical x-ray exposure practice. Therefore, if an unskilled radiologist practices using visual and spatial aids,the accuracy will be improved in skull lateral x-ray projection.

Study on Maximizing Scintillation Pixel Array Image by Changing Scintillator Bottom Surface Treatment in a 4 × 4 Array SiPM Photosensor with 3 mm × 3 mm Pixels for Improved Spatial Resolution (공간분해능 향상을 위한 3 mm × 3 mm 픽셀을 지닌 4 × 4 배열의 SiPM 광센서에서의 섬광체 바닥 면 처리의 변경을 통한 섬광 픽셀 배열 영상의 최대화 연구)

  • Woojin Jo;Seung-Jae Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.5
    • /
    • pp.491-498
    • /
    • 2024
  • Preclinical positron emission tomography (PET) requires excellent spatial resolution because the subject of imaging is a very small animal. To achieve this, a detector is configured using fine scintillation pixels. In this study, we aim to increase the scintillation pixel array by processing the bottom surface of the scintillation pixels differently from the array of scintillation pixels that can be imaged in the same photosensor performed in the previous study. To this end, we designed a detector using DETECT2000, which can simulate light in the scintillator, and performed a simulation. The detector was configured from an 11 × 11 array to a 16 × 16 array, and the bottom surface was configured as a polished surface (POLISH) and a rough surface (GROUND) to obtain a flood image. As a result, it was confirmed that the scintillation pixel images were better separated on the GROUND surface than on the POLISH surface as the scintillation pixel array expanded. Furthermore, on the GROUND surface, it was confirmed that the peaks of the scintillation pixel images in the corner area were separated and imaged even in the 16 × 16 array.

Feasibility Study of Modifying Diagnostic Radiation Dose using Magnetic Field (자기장을 이용한 진단방사선 선량 변화 가능성 연구)

  • Jeong-Min Seo
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.5
    • /
    • pp.509-513
    • /
    • 2024
  • This study investigated the feasibility of applying the changes in electron dose distribution, observed in high-energy therapeutic radiation using magnetic fields, to low-energy diagnostic radiation. The diagnostic X-ray exposure conditions were set with a tube current of 200 mA, source-to-detector distance (SDD) of 100 cm, exposure time of 1.0 sec, and an irradiation field size of 20 × 20 cm2. The tube voltage was varied from 70 to 100 kVp in 10 kVp increments. A 0.5 T permanent Nd magnet was used to create a magnetic field below the collimator. Measurements were repeated 20 times for each tube voltage, both with and without the magnetic field, and were compared using an independent-samples t-test. While slight differences of dose were observed at tube voltages of 70, 80, and 90 kVp, no statistically significant differences were found (p > .05). However, a significant difference was observed at 100 kVp (p = .048). Based on these findings, it is suggested that applying higher energy, longer exposure times, stronger magnetic fields, and high-performance detectors could potentially modify the electron dose distribution in diagnostic radiation. This could contribute to dose reduction for patients and improvement in the quality of medical imaging.

Analysis of Adverse Reactions to Computed Tomography Contrast Medium (컴퓨터 단층촬영에 사용되는 조영제의 부작용 발생에 대한 분석)

  • Kwon, Ki-Soo;Jeong, Jae-Sim
    • Journal of Korean Biological Nursing Science
    • /
    • v.6 no.2
    • /
    • pp.57-68
    • /
    • 2004
  • The contrast medium is very commonly used in more than 90% of computed tomography(CT) scans. It is difficult to predict the occurrence of adverse reactions and the degree of adverse reactions are diverse from mild urticaria, itching, nausea, vomiting to even cardiopulmonary arrest. The purpose of this study was to evaluate the symptoms, occurrence rate and risk factors of the adverse reactions in patients after contrast injection during CT examinations. Two hundreds sixty-five patients showed symptoms of adverse reactions out of 71,117 adult patients who received intravenous contrast administration during CT scans from January 2003 to December 2003 at a general hospital. Data was collected by reviewing adverse reaction records and electronic medical record. The results of this study were as follows; 1. Adverse reactions occurred in 265 out of a total of 71,117 patients(0.37%). Clinical symptoms of adverse reactions were most commonly dermatologic problems such as urticaria(69.81%) and itching(63.02%), followed by dyspnea(14.34%), dizziness(11.70%), nausea(6.79%), and vomiting(7.17%). 2. Anaphylactoid reactions occurred in 47 out of a total of 265 patients, and their pattern of symptoms were most commonly related to cardiovascular system(90.91%), followed by respiratory system(82.22%), gastrointestinal system(51.72%), and dermatologic system(16.51%). Eleven patients were transferred to emergency room for further treatment and two patients needed cardiopulmonary resuscitation. 3. The adverse reactions were significantly more common in women than in men(0.46% vs.0.32%, p=.003) and in type D contrast medium than the others(p<.001). The occurrence rate of adverse reactions was not significantly different according to the age and infusion speed of the contrast medium.

  • PDF

Relationship Between pSUV of $^{18}F$-FDG PET/CT and Pathological Diagnosis in Breast Cancer (유방암에서 $^{18}F$-FDG PET/CT의 pSUV와 병리학적 진단과의 연관성)

  • Kim, Mi-Young
    • Journal of radiological science and technology
    • /
    • v.36 no.4
    • /
    • pp.305-311
    • /
    • 2013
  • The purpose of this study was to evaluate the Pathological Diagnosis associated with pSUV uptake of $^{18}F$-FDG PET/CT. We had enrolled 39 women that underwent $^{18}F$-FDG PET/CT before operative. We evaluated whether there was correlation between the pSUV of $^{18}F$-FDG PET/CT and prognostic factors. As a results, pSUV level increase according to tumor size but pSUV had no significant association with tumor size. pSUV of high histologic grade was higher than low histologic grade, and pSUV showed positive correlations with histologic grade. The ER and PR showed significant negative correlations with the pSUV of $^{18}F$-FDG PET/CT. Therefore, our results demonstrated that an correlation exists between pSUV and prognostic factors such as histologic grade, ER and PR.

Comparison of Curriculums of Dental Hygiene Education Programs for B. S Degree (학사치과위생사 양성을 위한 교육과정 비교연구)

  • Cho, Young-Sik
    • Journal of dental hygiene science
    • /
    • v.5 no.4
    • /
    • pp.251-258
    • /
    • 2005
  • The objective of this research was to analyze curriculum of dental hygiene education program for B.S degree in US and compare with Korea and Japan. The curriculum was classified six domain based on job classification and National Board Examination in Korea. Oral biology content included oral anatomy,dental anatomy,oral histology,oral pathology. Oral physiology was excluded. Clinical dentistry content included only oral radiology, periodontics, dental material,pain control. Most program integrated clinical dental hygiene courses. Most program provided dental practice management content and dental hygiene research courses. Diverse program such as A.S degree,B.S degree,degree completion,distance education programs enabled students to develop their career effectively.

  • PDF

A Dose Analysis on the Ovary According to the Type of Shielding Material and the Change of Additional Filter in Radiography Using Diagnostic X-ray (진단용 X선을 이용한 방사선검사에서 차폐체 모양과 부가필터 변화에 따른 난소의 선량 분석)

  • Choi, Joon-Ho
    • Journal of radiological science and technology
    • /
    • v.42 no.6
    • /
    • pp.429-434
    • /
    • 2019
  • The gonads are directly affected by radiation exposure during radiography of the pelvis, abdomen, and spine. Exposure of the gonads to radiation can cause genetic mutations and can result in the occurrence of malignant tumors. In this study, we created three types of shielding material shapes for shielding of the ovaries, which are the gonads of female during radiography of the pelvis, and comparative evaluations using shadow shielding methods. The source surface distance(SSD) was 100 cm and the field size was 42 cm × 43 cm. The three types of shielding material shapes(type 1, 2 and 3) were assessed and the entrance surface dose in the ovaries were measured. The thickness of the shielding material was expanded from 0.3 mm to 2.4 mm and after five repetitions, radiation values were measured and mean values were calculated. The mean dose were 3.09 mGy for type 1, 3.54 mGy for type 2, and 3.19 mGy for type 3, indicating that the measurements were the lowest for type 1. When an additional filter of 0.2 Cu + 1 Al was used, the dose were 3.72 mGy for type 1, 5.43 mGy for type 2, and 4.05 mGy for type 3, indicating that the measurements were the lowest for type 1. The results show that, even if the shielding material is not thick, in other words, even with a thickness of 2.94 mGy for the SN 3(0.9 mm) of type 1, shielding can be achieved, with a patient dose lower than the diagnostic reference level(3.42 mGy). Additionally, among the three types of shielding material, the type 1 appeared to be the most appropriate shielding material. It is thought that the use of shielding material could reduce the risk factors for stochastic effects or critical effects of ionizing radiation during pelvic or lumbar radiography.

Study on the Accuracy of Vessel Measurement According to Table Object Distance Changes (혈관조영장비의 테이블-피사체간 거리 변화에 따른 혈관측정 정확도 연구)

  • Kim, Seung-Gi
    • Journal of radiological science and technology
    • /
    • v.42 no.6
    • /
    • pp.435-440
    • /
    • 2019
  • This is to study the accuracy of the actual size according to the TOD(table object distance; TOD) change when measuring blood vessels using angiography equipment, and to help the optimal selection of the device used accordingly. Balls similar to the size of common vessels were calibrated with TOD using 30 mm, 20 mm, 10 mm, 5 mm and acrylic phantoms, catheter calibration from 0 cm to 10 cm, 20 cm and 30 cm, respectively. It was measured whether there was a change in the measured value according to the change. The equipment used was GE Innova 3131 IQ equipment, and the image reconstruction method was GE AW4.7 post processing program. Two radiotechnologists were scanned three times by catheter calibration method and 3DRA(3dimension rotational angiography; 3DRA) volume rendering method. The independent sample T-test showed 0.981 (p> 0.05) to verify the significance between the two observers. As a result, in case of catheter calibration, the error rate at TOD 0 mm and 10 mm is within ± 10%, but when the TOD is changed to 20 mm and 50 mm respectively, the tolerance is ± 10% except for 30 mm ball exceeded. On the other hand, 3DRA was included within the tolerance range of ± 10% overall even when the TOD was changed from 0 mm to 50 mm. In the catheter calibration method, the larger the TOD, the larger the error range, and the 3DRA method was able to measure vascular vessels accurately close to the actual measurement without any consideration of the TOD.