• Title/Summary/Keyword: Radiology science department

Search Result 2,933, Processing Time 0.031 seconds

Establishment of the Dose Constraints Using the Frequency Distribution for the Annual Exposure Dose per Radiation Worker (방사선작업종사자 1인당 연간 피폭 선량에 대한 빈도 분포를 이용한 선량제약치 설정 방안)

  • Sang-Min Park;Jeong-Min Seo
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.5
    • /
    • pp.391-402
    • /
    • 2024
  • In this study, an indicator for setting dose constraints was presented using the frequency distribution of the annual exposure dose per radiation worker. To this end, from January 2017 to December 2019, we surveyed personal dosimeter reading values per month for 13 radiography inspection offices that had reported the establishment of a workplace to move and use radioisotopes, etc. for the purpose of radiographic testing (RT) in Korea, and performed a frequency analysis of the annual exposure dose per radiation worker. In this study, the indicator for setting dose constraints was based on the 95th percentile according to the recommendations of international organizations related to radiation protection. As a result, the dose constraints in the field of RT was set at an average of 5.15 mSv over the three-year investigation period. The nuclear energy-related business operator, if was set its own dose constraints proposed in this study and was operated successfully, were able to manage the exposure dose inequality of 52 people, equivalent to 5% of registered radiation workers, and could expect a reduction in collective dose of 760 man-mSv. Therefore, the nuclear energy-related business operator set its own dose constraints using the indicator for setting dose constraints proposed in this study, will be able to achieve optimization of protection by excluding exposure situations in which a dose level higher than the set dose constraint is expected from the process of establishing a protection plan.

Evaluation of Diagnostic Usefulness of Thyroid Lesions of Deep Learning-based CAD System (딥러닝을 기반으로 한 CAD 시스템의 갑상샘 질환의 진단 유용성)

  • Chae Won Kang;Hyo Yeong Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.5
    • /
    • pp.551-556
    • /
    • 2024
  • This study aims to evaluate the diagnostic concordance and accuracy by comparing thyroid lesions diagnosed with the artificial intelligence-based computer-aided diagnosis (CAD) system, S-DetectTM, to the results of fine-needle aspiration biopsy(FNAB). A retrospective study was conducted involving 60 patients at N Hospital in Gyeongnam from May 2023 to September 2023. The study used S-DetectTM to analyze ultrasound findings and malignancy risk of thyroid nodules and compared these findings with FNAB results to determine accuracy. The study assessed the sensitivity, specificity, accuracy, positive predictive value (PPV), and negative predictive value (NPV) of S-DetectTM and evaluated the diagnostic concordance between the two methods using Kappa analysis. S-DetectTM demonstrated a sensitivity of 90.5%, specificity of 83.2%, accuracy of 88.3%, PPV of 80.7%, and NPV of 92.7%. The Kappa value for diagnostic agreement between S-DetectTM and FN AB was 0.719 (p<0.05), indicating a high level of agreement between the methods. Therefore, the CAD system S-DetectTM proves valuable in distinguishing between malignant and benign thyroid lesions and could reduce unnecessary tissue examinations when used appropriately before thyroid fine-needle aspiration.

The Study of Affecting Image Quality according to forward Scattering Dose used Additional Filter in Diagnostic Imaging System (부가필터 사용 시 전방 산란선량에 따른 화질 영향에 대한 연구)

  • Choi, Il-Hong;Kim, Kyo-Tae;Heo, Ye-Ji;Park, Hyong-Hu;Kang, Sang-Sik;Noh, Si-Cheol;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.8
    • /
    • pp.597-602
    • /
    • 2016
  • Recent clinical field utilizes the aluminium filter in order to reduce the low-energy photons. However, the usage of the filter can cause adverse effect on the image quality because of the scattered dose that is generated by X-ray hardening phenomenon. Further, usage of filter with improper thickness can be a reason of dose creep phenomenon where unnecessary exposure is generated towards the patient. In this study, the author evaluated the RMS and the RSD analysis in order to have a quantitative evaluation for the effect of forward scattering dose by the filter on the image. as a result of the study, the FSR and the RSD was increased together with the increasing of thickness of the filter. In this study the RSD means the standard deviation of the mean value is relatively size. It can be understood that the signal-to-noise ratio decreases when the average value is taken as a signal and the standard deviation is judged as a noise. The signal-to-noise ratio can understanding as index of resolution at image. Based on these findings, it was quantitatively verified that there is a correlation of the image quality with the FSR by using an additional filter. The results, a 2.5 mmAl which is as recommended by NCRP in the tube voltage of 70 kVp or more showed the 14.6% on the RSD when the filter was not in used. these results are considered able to be utilized as basic data for the study about the filter to improve the quality of the image.

Interpersonal Conflicts and Communication among Medical Residents, Nurses and Technologists (전공의와 간호사.의료기사간의 인간관계 갈등과 의사소통에 관한 연구)

  • Kim, Yong-Soon;Park, Jin-Hee;Lim, Ki-Young
    • Korea Journal of Hospital Management
    • /
    • v.11 no.2
    • /
    • pp.16-31
    • /
    • 2006
  • Through investigating communication contents, extent of conflict, and its causes between medical residents and nurses/technicians, this study will provide the effective communication skills to ease interpersonal conflicts and maintain healthy partner relationships. This is a descriptive study to find out the communication contents, extent of conflicts and its causes between medical residents and nurses/technicians. Data were collected from April $1^{st}$, 2004 to April $8^{th}$, 2004 from 118 medical residents, 288 nurses, 85 radiology technicians and 107 laboratory technicians in 4 university hospitals in Seoul capital region. Data analysis was done with SPSS version 11.0 using descriptive statistics, ANOVA and chi-test. Interpersonal conflict towards medical residents were rated higher by nurses than technicians (Nurses > Technologists = Medical residents). Causes of conflict showed regional differences. In communication contents, all regions showed "Thank you" and "Well done" as most pleasant comments. Medical residents proved other medical residents' negative comments as most unpleasant and nurses and technicians proved residents' commanding phrases, disrespectful speech, and urging comments to be most unpleasant. Communication between the center members of the medical organization is very important in treating patients and understanding each other. For smooth conflict resolutions and maintaining healthy partner relationships, continued education and support for appropriate communication and interpersonal relationship skills is needed.

  • PDF

IdBean: a Java GUI application for conversion of biological identifiers

  • Lee, Sang-Hyuk;Kim, Bum-Jin;Kim, Hyeon-Jin;Lee, Hook-Eun;Yu, Ung-Sik
    • BMB Reports
    • /
    • v.44 no.2
    • /
    • pp.107-112
    • /
    • 2011
  • We have developed a biologist-friendly, stand-alone Java GUI application, IdBean, for ID conversion. Our tool integrated most of the widely used ID conversion services that provide programmatic access. It is the first GUI ID conversion application that supports the direct merging as well as comparison of conversion results from multiple ID conversion services without manual effort. This tool will greatly help biologists who handle multiple ID types for the analyses of gene or gene product lists. By referring to multiple conversion services, the number of failed IDs can be reduced. By accessing ID conversion service online, it will potentially provide the most up-to-date conversion results. The application was developed in modular form; however, it can be re-packaged into plug-in form. For the development of a bioinformatics analysis tool, the module can be used as a built-in ID conversion component. It is available at http://neon.gachon.ac.kr/IdBean/.

Evaluation of the Usefulness for Air Gap Technique in Digital Magnification Mammography (디지털 유방확대촬영술에서 Air gap technique의 유용성 평가)

  • Kim, Mi-Young
    • Journal of radiological science and technology
    • /
    • v.37 no.2
    • /
    • pp.101-107
    • /
    • 2014
  • The purpose of this study was investigated optimal exposure condition in digital magnification mammography to decrease radiation dose and increase image quality of the examinee. Auto mode, the average glandular dose is higher than the manual mode. Average glandular dose and image quality were many differences on between grid and air gap technique in auto mode. However, Average glandular dose and signal-to-noise ratio were not different on between grid and air gap technique in manual mode. The signal-to-noise ratio was increased when using the air-gap technique in both mode. According to result, air gap technique may reduce average glandular dose and increase signal-to-noise ratio in digital magnification mammography.

Usefulness of Balloon-type Hemostatic Device After Transarterial Chemoembolization (간동맥 화학색전술 후 풍선형 지혈기구의 유용성)

  • Kim, Seung-Gi
    • Journal of radiological science and technology
    • /
    • v.42 no.3
    • /
    • pp.181-186
    • /
    • 2019
  • Transarterial chemoembolization is one of the most representative procedures for puncture of the femoral artery. In addition, the same procedure is often repeatedly performed many times, and Hepatocellular carcinoma patients due to cancer is significantly lowered blood tests, regardless of platelet counts are not good enough to stop bleeding. More importantly, hepatocellular carcinoma has a high degree of complication and disease severity, which makes it less likely that the condition of the body will be relatively inferior to other patients. In order to prevent delayed hemorrhage of the femoral artery puncture site after the procedure, it is advised to absolutely stabilize the limb so that it does not bend the limb for 3 hours after climbing in the ward. Therefore, I have been complaining about inconvenience. In addition, in order to prevent delayed hemorrhage after hemostasis, balloon type hemostatic device was used instead of sand bag which was placed on hemostatic site. The results of this study were compared with the results of actual application. The use of a balloon-type hemostatic device to increase the effectiveness of continuous hemostasis and to minimize the inconvenience during the time of patient's absolute bed rest, rather than raising the sandbag to prevent primary delayed hemorrhage by various methods in transarterial chemoembolization. It can be used as a substitute for existing sand bags because it can alleviate pain, increase satisfaction, and can be used as a disposable one.

Analysis of Patients with Cerebral Aneurysm Rupture Treated by Coil Embolization : Retrograde Study in Single Institute (코일색전술로 치료받은 뇌동맥류 파열 환자 분석 : 단일기관 후향적 연구)

  • Kim, Seung-Gi
    • Journal of radiological science and technology
    • /
    • v.42 no.5
    • /
    • pp.357-363
    • /
    • 2019
  • To the basic information of patients with subarachnoid hemorrhage due to rupture of cerebral aneurysm treated with coil embolization, and to identify the general trend of treatment through classification according to hospitalization route, residence distribution, location and size of cerebral aneurysm, and procedure. A total of 164 patients with ruptured cerebral aneurysms treated with coil embolization were 54(32.9%) males and 110(67.1%) females. The sex and frequency of occurrence by age group were the most in 50s(31.3%), and among them, females were the most. The hospitalization route was the most common in 122(74.4%) people who were admitted to the emergency room through 119 evacuation, 79(48.2%) patients lived in where hospitals belong to the hospital. The season had 23(14%) in December, 18(11%) in January, 15(9.1%) in February, and the anterior circulation was 153(93%). The largest size was 5-7 mm found in 63(38.4%) patients. Patients underwent initial coil embolization for subarachnoid hemorrhage due to cerebral aneurysm rupture treated more patients than the incidence of the population. As a result of cerebral aneurysm rupture was seasonally affected, and winter occurs more frequently, female than male, age 50 is most common, and ruptured cerebral aneurysm is 5-7 mm in size.

Application of Carbon Materials for the Development of Medical Devices (의료기기의 발전을 위한 탄소소재의 활용)

  • Yeong-Gon Kwak
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.27 no.1
    • /
    • pp.23-28
    • /
    • 2023
  • Carbon materials are widely used in many areas of our lives. A fiber having a carbon content of 90% or more obtained by heating an organic fiber precursor is referred to as a "carbon fiber". Carbon fibers are currently used in the medical market to manufacture radiation transmission device parts, artificial joints, and medical aids, as many developments have been made to utilize carbon fibers' characteristics such as light weight, radiation permeability, biocompatibility, high strength, high heat resistance, thermal conductivity, and electrical conductivity. In order to maintain body temperature and increase immunity in long-lasting nuclear medical examination and treatment through the idea of convergence of carbon materials and radiation technology, the quality of medical services can be improved by utilizing carbon materials. We should be aware of the domestic carbon-based medical device industry and make efforts to contribute to the development of medical devices. As a radiation expert, we should try to use our skills and experience to find items that can be fused with medical devices to develop various nuclear medical examination fields and radiographic examination fields that can be widely applied. We should actively engage in future technology development and carbon material research to strengthen the global competitiveness of the domestic medical device industry and improve the quality of medical services.

  • PDF

The Comparison of Usefulness between MDCT Angiography and DSA in the Diagnosis of Intracranial Aneurysm (뇌 동맥류 진단에 있어 디지털 감산 혈관조영술과 다중검출기 전산화단층촬영 혈관조영술의 유용성 비교)

  • Khang, Hyun-Soo;Seo, Sun-Youl;Han, Dong-Kyoon;Kwon, Soo-Il;Shim, Su-Jung;Cho, Sam-Ju
    • Progress in Medical Physics
    • /
    • v.22 no.4
    • /
    • pp.184-189
    • /
    • 2011
  • The purpose of this study was to compare the image between DSA and MDCT Angiography and to examine whether MDCT Angiography could be useful as a screening test for the diagnosis of cerebral aneurysm in patients who were diagnosed with cerebral aneurysm on DSA. Of patients who were diagnosed with cerebral aneurysm DSA at University Hospital, 194 patients who concomitantly underwent MDCT Angiography were enrolled in the current retrospective study. The methods for analyzing cerebral aneurysm were to analyze the presence of cerebral aneurysm on DSA and MDCT Angiography. In cases in which it exceeded 1, the corresponding cases were classified as narrow-neck aneurysms. In otherwise cases, they were classified as wide-neck aneurysms. Thus, a comparative analysis could be performed to ascertain if cases were narrow-neck or wide-neck aneurysms. As compared with DSA, the sensitivity of MDCT Angiography for cerebral aneurysm was measured to be 97.4%. The degree of consistency between narrow-neck and wide-neck aneurysms was 90.2% and the proportion of undetectable an at MDCT Angiography was 2.54%. mean size was 2.4 mm. It is expected that a non-invasive diagnostic modality for a screening test for cerebral aneurysm, MDCT Angiography might be a very useful regimen as compared with an invasive one, DSA.