• Title/Summary/Keyword: Radiology science department

Search Result 2,933, Processing Time 0.032 seconds

A Study on the Development of High-sensitivity AEC-sensor for Minimization of Dose Creep in Diagnostic Imaging System (진단영상 시스템에서 선량크리프 현상의 최소화를 위한 고감도 AEC 센서에 관한 연구)

  • Kim, Kyo-Tae;Han, Moo-Jae;Heo, Ye-Ji;Kim, Joo-Hee;Kang, Sang-Sik;Park, Ji-Koon;Nam, Sang-Hee
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.5
    • /
    • pp.321-325
    • /
    • 2016
  • Dose creep is one of clinical errors that arises from the tester's inexperience or carelessness, and according to Task Group #116 of American Association of Physicists in Medicine, its continued occurrence is being reported in the digital method. At this point, the demand for an automatic exposure control device that minimizes the dose creep phenomenon and can improve reproducibility is increasing. In this study is to consider the automatic exposure control device sensor that can is not only easy to produce, but also reduce the dose creep phenomenon by conducting a research on high-efficient semiconductor sensor. As a result, the Intrinsic-type and PIN-type sensors have excellent optical property compared to Ref sensor, would have less shading effect, and have relatively low sensitivity, but would provide accurate feedback signals to automatic exposure control device with its consistent tendency according to exposure condition changes.

Elliptical Centric Techniques and Tricks About the Usefulness of the Clinical Application (Elliptical Centric과 TRICKS 기법의 임상 적용에 관한 유용성 연구)

  • Kim, Sae-Ssak;Goo, Eun-Hoe;Dong, Kyung-Rae;Kweon, Dae-Chel;Lee, Jae-Seung;Cho, Jae-Hwan;Park, Chang-Hee
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.2
    • /
    • pp.83-90
    • /
    • 2011
  • To prospectively determine the diagnostic performance a combination of standard bolus-chase magnetic resonance (MR) angiography and MR angiography with time-resolved imaging of contrast kinetics (TRICKS) for depicting severity of the head and neck vascular diseases. Over a period of two months, A total of 100 patients(average ages : $50{\pm}8$, male : 60, female : 40) with head and neck vascular diseases were performed on the GE excite 3.0 T units with 8-channel head coil and 4-channel NV coil. Imaging parameters for a typical study were as follow: SBC(TR/ TE/ FA/ SliceThicken./ Slab/ Freq./ FOV/ BW/Scan Time) = 5.4/ min/ 30/ 2/ zip2/ 70/ $224{\times}448$/ 30/ 62.50/ 28, TRICKS(TR/ TE/ FA/ Slice Thicken/Slab/ Freq./ FOV/ BW/ Temp Res./ Scan Time = 3.6/ min/ 25/ 4/ 30/ $160{\pm}384$, zip512/ 30/ 100/ 1 to 1.5/ 23). The analysis of all MR images, which have respect-ively classified two techniques into some diseases. The results of the former were divided into two groups(SBC, TRICKS)with 4 grading of two reader, respectively. Wilcoxon signed rank test was used to determine if a significant difference between imaging techniques existed(p < 0.05). In 33 of 100 patients, arterio-venous malformation was 11% at TRICKS, subclavian vein stenosis : 8%, fistular sinus : 4%, jugular vein stenosis:6%, Middle Cerebral Artery bypass surgery : 4%, p < 0.05). The rest of 67 patients were considered as the results of SBC(14% in the basilar artery stenosis, carotid stenosis : 16%, vertebral stenosis : 17%, central neuro-cytoma : 5%, meningioma : 5%, Not appliable : 10%, p < 0.05). Sensitivity and specificity of TRICKS MR angiography in SVS, FS, JVS, MCABS were improved compared with those at standard MR angiography. In SBS MR angiography which were improved in BAS, CS, VS, CN, Meningioma. In conclusion, TRICKS MR angiography of the SVS, FS, JVS, MCABS is superior to standard MR angiography regarding the number of diagnostic grading. The SBS MR angiography were improved in BAS, CS, VS, CN, Meningioma. and assessment of the degree of luminal narrowing on both TRICKS and SBS.

  • PDF

Nationwide Trends of Gatekeeper to Invasive Coronary Angiography in Suspected Coronary Artery Disease

  • Min Jae Cha;William D Kim;Hoyoun Won;Jaeeun Joo;Hasung Kim;In-Cheol Kim;Jin Young Kim;Seonhwa Lee;Iksung Cho
    • Korean Circulation Journal
    • /
    • v.52 no.11
    • /
    • pp.814-825
    • /
    • 2022
  • Background and Objectives: Real-world trends in the utility and type of gatekeeping studies in invasive coronary angiography (ICA) requires further investigation. Methods: We identified outpatients who underwent noninvasive cardiac tests or directly ICA for suspected coronary artery disease (CAD) from the nationwide Korea Health Insurance Review and Assessment Service-National Patient Sample database between 2012 and 2018. Results: Among 71,401 patients, the percentage of patients who were evaluated for suspected CAD was 34.7% for treadmill test (TMT), 4.2% for single-photon emission computed tomography (SPECT), 24.2% for coronary computed tomography angiography (CCTA), 1.6% for multiple gatekeepers, and 32.3% for directly ICA without noninvasive studies. The proportion of CCTA as a gatekeeper showed linear increase, (18.6% in 2012 and 28.8% in 2018; p<0.001), while those of TMT, SPECT, and direct ICA have decreased (p<0.001, p=0.03, and p<0.001, respectively). The overall incidence of downstream ICA after gatekeeper was 13.8% (6,662/48,346), and SPECT showed higher ICA rate in pairwise comparison with TMT and CCTA (p<0.001). Patients who performed gatekeepers before ICA showed higher rate of subsequent PCI (34.7% vs. 32.3%; p<0.001) and CABG (3.5% vs. 1.0%; p<0.001), compared to those who directly underwent ICA, and CCTA was associated with higher revascularization rate after ICA in pairwise comparison with TMT and SPECT (p<0.001). Conclusions: Nationwide database demonstrated that CCTA is utilized increasingly as a gatekeeper for ICA and is associated with high revascularization rate after ICA in outpatients with suspected CAD.

Analysis of Hematological Factor to Predict of the Gallbladder Stone in Abdominal Ultrasound Images (복부초음파 영상에서 담낭담석을 예측하는 혈액학적 수치의 분석)

  • An, Hyun;Hwang, Chul-Hwan;Im, In-chul
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.3
    • /
    • pp.131-137
    • /
    • 2017
  • This study investigated the risk factor of Gallbladder stone in Busan and Kyungnam area. The subjects of the experiment was performed with patients by abdominal ultrasonography among the patients who came to the P hospital from June 2016 to December 2016. Among them, risk factors were analyzed on 353 people at the same time when abdominal ultrasonography and hematological test. The statistical analysis of risk factors related to the Gallbladder stone was performed by independent t-test and chi-square test. In consider of difference verification result for calculations odds ratio about independent variables, multiple logistic regression analysis to conduct verify adequacy by calculating forecasting model from variable. As a result, Gallbladder stone risk factors have relevance to age ${\gamma}GTP$ with probability model and values to calculated. Age was showed sensitivity 49.7%, specificity 82.2%, receiver operating characteristic area under curve 0.724. Forecasting probability sensitivity 69.3%, specificity 62.4%, receiver operating characteristic area under curve 0.699 showed, ${\gamma}GTP$ confirmed validity of forecasting model.

Evaluation of Classification Performance of Inception V3 Algorithm for Chest X-ray Images of Patients with Cardiomegaly (심장비대증 환자의 흉부 X선 영상에 대한 Inception V3 알고리즘의 분류 성능평가)

  • Jeong, Woo-Yeon;Kim, Jung-Hun;Park, Ji-Eun;Kim, Min-Jeong;Lee, Jong-Min
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.4
    • /
    • pp.455-461
    • /
    • 2021
  • Cardiomegaly is one of the most common diseases seen on chest X-rays, but if it is not detected early, it can cause serious complications. In view of this, in recent years, many researches on image analysis in which deep learning algorithms using artificial intelligence are applied to medical care have been conducted with the development of various science and technology fields. In this paper, we would like to evaluate whether the Inception V3 deep learning model is a useful model for the classification of Cardiomegaly using chest X-ray images. For the images used, a total of 1026 chest X-ray images of patients diagnosed with normal heart and those diagnosed with Cardiomegaly in Kyungpook National University Hospital were used. As a result of the experiment, the classification accuracy and loss of the Inception V3 deep learning model according to the presence or absence of Cardiomegaly were 96.0% and 0.22%, respectively. From the research results, it was found that the Inception V3 deep learning model is an excellent deep learning model for feature extraction and classification of chest image data. The Inception V3 deep learning model is considered to be a useful deep learning model for classification of chest diseases, and if such excellent research results are obtained by conducting research using a little more variety of medical image data, I think it will be great help for doctor's diagnosis in future.

Evaluation of Applicability of Customized Bolus According to 3D Printer Material Characteristics (3D 프린터 소재 특성에 따른 맞춤형 볼루스의 적용성 평가)

  • Kyung-Tae Kwon;Hui-Min Jang;Myeong-Seong Yoon
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.7
    • /
    • pp.1091-1097
    • /
    • 2023
  • Bolus is used in radiation therapy to prescribe an even dose to the tumor when the skin surface is inclined or has irregularities. At this time, the dose to the skin surface increases. Due to the patient's unique body structure and irregular skin, voids may occur between the bolus and the skin, which may reduce the accuracy of treatment. Therefore, in this study, the existing bolus and the self-produced bolus through 3D printing were applied to the nasal area, and the difference between the surface dose after treatment plan and the dose directly measured with an Optically Stimulated luminescence(OSL) dosimeter was compared to the existing bolus. The bolus rate was 97%, PLA 100.33%, ePETELA 75A 100.53%, and ePETELA 85A 100.36%. It was confirmed that there was little error in the measurement values and treatment plan values for each material. In addition, compared to when applying a conventional bolus, a difference of -3% to +0.5% for a 3D printed bolus can be confirmed, so a customized bolus produced through 3D printing can complement the shortcomings of the existing bolus. It is believed that there will be.

Consideration on Methods to Suppress Metal Artifacts Caused by Spinal Fusion during Spine MRI Study (척추 MRI 검사 시 척추 유합술로 인한 금속 인공물 억제 방법에 대한 고찰)

  • Se-Jong Yoo;Soon-Yong Kwon;Seong-Ho Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.7
    • /
    • pp.1123-1131
    • /
    • 2023
  • This study aimed to present a method to effectively suppress metal artifacts caused by spinal fusion surgery during spinal MRI study. For this purpose, a phantom made of spinal surgery screws was created to reproduce the metal artifact. Then, images were acquired with 1.5T and 3.0T MRI to evaluate changes in metal artifacts according to magnetic field strength. In addition, metal artifacts were evaluated by increasing the receive bandwidth to 200, 400 and 800 Hz/PX. As a result, metal artifacts occurring in images obtained from the 1.5T MRI decreased by approximately 52.2% compared to images obtained from the 3.0T MRI, showing a significant difference (p<0.05). In particular, the signal loss and signal pile up areas were reduced by approximately 52.81% and 42.71%, respectively, showing a significant effect in suppressing metal artifacts. On the other hand, when images were acquired while increasing the receive bandwidth from 200 to 800 Hz/PX, there was no significant effect, with a decrease of up to 8.93% for the 1.5T MRI and up to 10.98% for the 3.0T MRI (p>0.05). As a result of this study, increasing the receive bandwidth reduced signal loss and reduced some metal artifacts, but did not have a significant effect because it did not suppress signal pile up. However, when the magnetic field strength was reduced from 3.0T to 1.5T, signal loss and signal pile up were greatly reduced, effectively improving the metal artifact. Therefore, in order to suppress metal artifacts caused by spinal fusion surgery, study using a low magnetic field MRI can be said to be the most effective method.

The Position for Measuring BMD of the Distal Radius and The Study of the Correlation Between the Distal Radius and Lumba (원위 요골 골밀도의 측정 자세 및 요추 골밀도의 상관관계에 관한 연구)

  • Han, Man-Seok;Jeon, Chul-Min;Kim, Jong-Jin;Seo, Seon-Youl;Kim, Yong-Kyun
    • Journal of radiological science and technology
    • /
    • v.33 no.1
    • /
    • pp.19-24
    • /
    • 2010
  • The aim of this study was to evaluate the change of bone mineral density according to distal radius rotation and the correlations of the lowest BMD measured by DXA at the lumba versus distal radius. The eleven males were projected distal radius by DR X-ray and the measurement of BMD by DXA of the appropriate position of the forearm were performed on 21 males. The healthy 11 and 21 volunteers without any history of operations, anomalies, or trauma were enrolled. The experiment was performed by two methods. First, The DR X-ray was measured distal radius of 11 males in pronation and supination with three, six and nine degrees, including a neutral position. The ROI was measured by the m-view program on the PACS monitor. Second, The DXA was measured distal radius of 21 males in pronation and supination with five and ten degrees, including a neutral position to evaluate the changes of BMD according to the rotation. A correlation of the BMD in the distal radius with BMD that lumbar spine was performed, along with analysis of the data by SPSS 12.0v. The mean rotation angle of the distal radius about eleven males DR X-ray measured $7^{\circ}$ of pronation (82%, n = 9), $6^{\circ}$ of supination and $0^{\circ}$ of neutral of (9%, n = 1), The total average rotation angle in 11 male was $5.1^{\circ}$ of pronation. The rotation angle of the distal radius about twenty one males on DXA measured $7.2^{\circ}$ of pronation (43%, n = 9), $7^{\circ}$ of supination (24%, n = 5), and $0^{\circ}$ of neutral (33%, n = 7), The total average rotation angle in 21 people was $4.1^{\circ}$ of pronation. The correlation of the analysis of lumba and distal radius were r = 3.0, p = 0.18. consequently, The correlation was not significance. Because BMD of lumba was not coverd for BMD of the distal radius, with a neutral position, Pronation is needed for BMD in the distal radius with the rotation angle measuring at the lowest BMD. the rotation angle about five degrees of pronation of the distal radius is recommended.

Study on Oneself Developed to Apparatus Position of Measurement of BMD in the Distal Radius (자체 개발한 보조기구로 원위 요골의 골밀도 측정 자세 연구)

  • Han, Man-Seok;Song, Jae-Yong;Lee, Hyun-Kuk;Yu, Se-Jong;Kim, Yong-Kyun
    • Journal of radiological science and technology
    • /
    • v.32 no.4
    • /
    • pp.419-426
    • /
    • 2009
  • Purpose : The aim of this study was to evaluate the difference of bone mineral density according to distal radius rotation and to develop the supporting tool to measure rotation angles. Materials and Methods : CT scanning and the measurement of BMD by DXA of the appropriate position of the forearm were performed on 20 males. Twenty healthy volunteers without any history of operations, anomalies, or trauma were enrolled. The CT scan was used to evaluate the cross sectional structure and the rotation angle on the horizontal plane of the distal radius. The rotational angle was measured by the m-view program on the PACS monitor. The DXA was used in 20 dried radii of cadaveric specimens in pronation and supination with five and ten degrees, respectively, including a neutral position (zero degrees) to evaluate the changes of BMD according to the rotation. Results : The mean rotation angle of the distal radius on CT was 7.4 degrees of supination in 16 cases (80%), 3.3 degrees of pronation in three cases (15%), and zero degree of neutral in one case (9%), respectively. The total average rotation angle in 20 people was 5.4 degrees of supination. In the cadaveric study, the BMD of the distal radius was different according to the rotational angles. The lowest BMD was obtained at 3.3 degrees of supination. Conclusion : In the case of the measurement of BMD in the distal radius with a neutral position, the rotational angle of the distal radius is close to supination. Pronation is needed for the constant measurement of BMD in the distal radius with the rotation angle measuring at the lowest BMD and about five degrees of pronation of the distal radius is recommended.

  • PDF

Investigation on the Perception of Mandatory Clinical Practice in the Department of Radiology Following the Amendment of the Medical Technologists Act (의료기사 등에 관한 법률 개정으로 방사선(학)과 현장실습 의무화에 따른 인식 조사)

  • Jeong-Mu Lee;Yong-Ki Lee;Sung-Min Ahn
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.3
    • /
    • pp.293-300
    • /
    • 2024
  • On October 31, 2023, the revision of the Medical Technologist Act made it mandatory to complete field training courses in order to obtain a license as a radiologic technologist. Therefore, we would like to survey the actual situation of field training in medical institutions to inform the revised Medical Technologist Act and propose improvement measures to increase the effectiveness of field training. A survey was conducted from March to April, 2023, among radiologic technologists working in medical institutions. The questionnaire was sent through a form on a domestic portal site, Company N, and 120 respondents completed it. Eighty-two respondents, or 68.3 percent, had experience in educating on-the-job training students. 58% of the respondents were aware of the fact that the amendment to the Act on Medical Technologist etc. made field training mandatory to obtain a radiologic technologist license. In accordance with Article 9 of the Medical Technologist Act, which prohibits unlicensed persons from practicing, 50% of the respondents were aware that those who are in training to complete an education course equivalent to the license they are seeking to obtain at a university or other institution are allowed to practice as medical Technologists. When asked what is currently taught during fieldwork, 6% of respondents said that they are required to perform radiation-generating activities in addition to observing, guiding patients, and positioning and moving patients. When asked about the future direction of education as fieldwork becomes mandatory for licensure, 77% of respondents said that they will teach more than they currently do. When asked about the appropriate total length of fieldwork, 35% said 12 weeks and 480 hours, 33% said 8 weeks and 320 hours, and 27% said 16 weeks and 640 hours. It can be seen that the current on-the-job training is inadequate according to various regulations, and students' satisfaction is low. However, with the revision of the Act on Medical Technologists, field training has become mandatory to obtain a license as a radiologist, and it is necessary to improve the educational conditions of field training. Therefore, it is necessary to comply with the Nuclear Safety Act and the Rules on the Safety Management of Diagnostic Radiation Generating Devices, introduce standardized training objectives and evaluation systems, designate training hospitals and radiologists in charge of training, and introduce extended training periods and simulation exercises to internalize field training.