Factors affecting modulation transfer function measurements in cone-beam computed tomographic images

  • Choi, Jin-Woo
    • Imaging Science in Dentistry
    • /
    • v.49 no.2
    • /
    • pp.131-137
    • /
    • 2019
  • Purpose: This study was designed to investigate the effects of voxel size, the oversampling technique, and the direction and area of measurement on modulation transfer function (MTF) values to identify the optimal method of MTF measurement. Materials and Methods: Images of the wire inserts of the SedentexCT IQ phantom were acquired, and MTF values were calculated under different conditions(voxel size of 0.1, 0.2, and 0.3 mm; 5 oversampling techniques; simulated pixel location errors; and different directions and areas of measurement). The differences in the MTF values across various conditions were evaluated. Results: The MTF 10 values showed smaller standard deviations than the MTF 50 values. Stable and accurate MTF values were obtained in the 0.1-mm voxel images. In the 0.3-mm voxel images, oversampling techniques of 11 lines or more did not show significant differences in MTF values depending on the presence of simulated location errors. MTF 10 values showed significant differences according to the direction and area of the measurement. Conclusion: To measure more accurate and stable MTF values, it is better to measure MTF 10 values in small-voxel images. In large-voxel images, the proper oversampling technique is required. MTF values from the radial and tangential directions may be different, and MTF values vary depending on the measured area.

Risk factors for external root resorption of maxillary second molars associated with third molars

  • Choi, Jinwoo
    • Imaging Science in Dentistry
    • /
    • v.52 no.3
    • /
    • pp.289-294
    • /
    • 2022
  • Purpose: This study aimed to evaluate the diagnostic performance of panoramic images compared to cone-beam computed tomography (CBCT) imaging for maxillary third molar (M3)-associated external root resorption (ERR), and to identify the risk factors of ERR on panoramic images. Materials and Methods: The study population was composed of all patients who underwent panoramic imaging at Dankook University Dental Hospital from May to October 2019. In total, 397 cases of maxillary M3s in 247 patients(147 men and 100 women) were included. The diagnostic accuracy of ERR in panoramic images compared to CBCT images was evaluated using the chi-square test. To identify risk factors for ERR, dental records and panoramic findings were evaluated by logistic regression analysis. Results: The diagnostic accuracy of ERR on panoramic images was 0.79 compared to CBCT images (P<0.05). Superimposition of M3s onto second molars (M2) was associated with an approximately 33 times higher risk of ERR than separated M3s(P<0.05). Impacted M3s showed a 5 times higher risk of ERR than erupted M3s(P<0.05). Conclusion: ERR related to M3s is a common clinical condition, and superimposition of M3 onto M2 on panoramic images was the most important risk factor for ERR. It seemed that CBCT examinations for maxillary M3s might be indicated for ERR diagnosis especially if panoramic radiographs show superimposition of M3 onto M2. Impaction itself was also a risk factor, and it should be carefully examined.

Effect of Antibacterial Film Containing Silver Ions on MRI (은(Ag)이온이 함유된 항균필름이 MRI에 미치는 영향)

  • Shin, Byeong Geun;Kim, Seong Hu;Ahn, Seong Min
    • Journal of radiological science and technology
    • /
    • v.44 no.3
    • /
    • pp.219-224
    • /
    • 2021
  • The purpose of these experiments is often to scan infected patients with MRI. Therefore, it is to investigate whether the antibacterial film containing silver ions, which is a non-magnetic substance, affects magnetic resonance imaging. In this experiment, the ACR phantom was used, not the patient. The ACR phantom was wrapped in an antibacterial film and the SNR, CNR, sagittal localization image, and geometrical accuracy were compared before and after. The experiment was performed 10 times and the averaged values were compared. There were no significant differences in the results of all experiments. The FDA recommends removing metal and antibacterial film masks during MRI scans. The reason is that there was one case of injury with facial burns. When I touched the antibacterial film to check the fever during the 2 hour experiment, I did not feel any particular fever. In light of the experimental results, it would be helpful to use an antibacterial film when testing an infected patient. The reason is that there isn't a difference before and after the experiment of SNR, CNR, and sagittal localization images.

Relation of Handwashing and Isolate of Bacteria from Mobile Phones of Healthcare Workers in a University Hospital

  • Choi, Min-Gyu;Kim, Sang-Ha;Park, Kyu-Ri;Kim, Young-Kwon;Kim, Jungho;Yu, Young-Bin
    • Biomedical Science Letters
    • /
    • v.27 no.4
    • /
    • pp.310-316
    • /
    • 2021
  • Mobile phones used by healthcare workers are not only an indicator of the contamination of healthcare associated bacteria, but can also be another source of infection. The number and time of handwashing, mobile phone operation time and disinfection were highly relation with the bacterial contamination on the surface of mobile phone. Healthcare associated bacteria isolated from the mobile phone surface were 28 MRCoNS (48.3%), 14 S. aureus (24.2%), 3 MRSA (5.2%), 5 A. baumannii (8.6%), 3 MRAB (5.2%), 3 Entrococcus spp. (5.1%), 2 Pantoea spp. (3.4%), 2 A. lowffii (3.4%), 1 E. cloacae (1.7%), 1 P. stutzeri (1.7%), and P. mirabillis (1.7%). For isolation according to department, 2 MRAB from the emergency room and 1 MRSA from intensive unit, the radiology team and the rehabilitation medical team, respectively were isolated. As a result of the relation of isolates from the department of patient contact (ER, RT, GW, CP, ICU, RMT), the bacterial isolation rate was 75% and the department of patient non-contact (MRT) was 10%.

Preoperative Prediction of Ductal Carcinoma in situ Underestimation of the Breast using Dynamic Contrast Enhanced and Diffusion-weighted Imaging (역동적 유방 자기공명 영상 및 확산 강조영상을 이용한 관상피내암종 저평가 수술전 예측)

  • Park, Mina;Kim, Eun-Kyung;Kim, Min Jung;Moon, Hee Jung
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.2
    • /
    • pp.101-109
    • /
    • 2013
  • Objective: To investigate roles of dynamic contrast enhanced magnetic resonance (DCE MR) and diffusion-weighted (DW) imaging in preoperative prediction of underestimation of ductal carcinoma in situ (DCIS) ${\geq}2cm$ on US guided core needle biopsy. Materials and Methods: Twenty two patients with DCIS on US-guided 14 gauge core needle biopsy were included. Patients were divided into a group with and without DCIS underestimation based on histopathology. MR images including DCE and DW imaging were obtained with a 3.0-T MR. The lesion type (mass or non-mass), enhancement pattern, peak enhancement, and apparent diffusion coefficient (ADC) values of proven malignant masses were generated using software of CADstream and compared between two groups using Fisher's exact test and Mann Whitney test. Results: Eight patients were in the group with underestimation and 14 patients were in the group without underestimation. The lesion type and enhancement pattern were not different between two groups (P values = 1.000 and 0.613, respectively). The median peak enhancement of lesions with underestimation was 159.5%, higher than 133.5% of those without underestimation, but not significant (P value = 0.413). The median ADC value of lesions with underestimation was $1.26{\times}10^{-3}mm^2/sec$, substantially lower than $1.35{\times}10^{-3}mm^2/sec$ of those without underestimation (P value = 0.094). Conclusion: ADC values had the potential to preoperatively predict DCIS underestimation on US-guided core needle biopsy, although a large prospective series study should be conducted to confirm these results.

Effect of Fractionated X-ray Irradiation on Sprouted Barley Growth and Chlorophyll Concentration (X선의 분할조사가 새싹보리 생장과 클로로필 농도에 미치는 영향)

  • In Suck Park;Won-Jeong Lee;Sang-Bok Jeong
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.7
    • /
    • pp.1171-1178
    • /
    • 2023
  • In study, we investigated changes on growth and chlorophyll concentration on sprouted barley by fractionated X-ray irradiation (FXI). Group was divided into the control group (CG), 1-time irradiation group (30 Gy once), 2-time irradiation group (15 Gy 2 times), and 3-time irradiation group (10 Gy 3 times), and 20 grains were used per group. Experimental group (EG) was exposed by using linear accelerator (Clinac IS, VERIAN, USA), by 6 MV X-ray, SSD 100 cm, 18×10 cm2, 600 MU/min. Length was measured every day until 9th day, and chlorophyl was analyzed using spectrophotometer(uv-1800, shimadzu, japan) in 9th day. Data analysis was performed the One-way ANOVA using SPSS ver 26.0(Chicago, IL, USA). In the pre-germination irradiation group (Pre-GIG), the CG had greater length than the EG on all measurement days, and as the number of FXI increased, the length became shorter. In the post-germination irradiation group (Post-GIG), the length of the CG was statistically significantly greater than that of the EG on all measurement days, and as the number of FXI increased, the length also became longer. The chlorophyll concentration was higher in the Post-GIG than in the Pre-GIG, and chlorophyll concentrations of EG was higher in the Pre-GIG than in the CG, as well as and Post-GIG. In addition, the smaller the number of FXI, the higher the chlorophyll concentration in both groups. FXI was found to affect the growth and chlorophyll concentration of sprouted barley.

Calibration Examination of Dose Area Product Meters using X-ray (X선을 이용한 면적선량계의 교정 연구)

  • Jung, Jae Eun;Won, Do-Yeon;Jung, Hong-Moon;Kweon, Dae Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.1
    • /
    • pp.37-42
    • /
    • 2017
  • We measured the absorbed dose and the area dose using an ionization chamber type of area dose product (DAP) meter and measured the calibration factor in the X-ray examination. In the indirect dose measurement method, the detector was installed in the radiation part of the X-ray equipment, and the measured value was calculated as the dose at the exposure part. The instrument used to calculate the calibration factor was an X-ray equipment (DK-550R / F, DongKang Medical Co., Ltd., Seoul, Korea). The calibration method for the calibration factor was to connect the DAP meter (PD-8100, Toreck Co. Ltd., Japan) to the calibration dosimeter tube voltage of 70 kV, tube current of 500 mA, 0.158 sec. The reference dosimeter used a semiconductor (DOSIMAX plus A, Scanditronix, $Wellh{\ddot{o}}fer$, Germany). After installing the DAP meter on the front of the multi-collimator of the ionization chamber, the calibration factor of the dosimeter was obtained using the reference dosimeter for accurate dose measurement. Experimental exposure values and values from the calibration dosimeter were calculated by multiplying each calibration factor. The calibration factor was calculated as 1.045. In order to calculate the calibration coefficient according to the tube voltage in the ionization type DAP dosimeter, the absorbed dose and the area dose were calculated and the calibration factor was calculated. The corrective area dose was calculated by calculating the calibration factor of the DAP meter.

Development of Imaging Gamma Probe Using the Position Sensitive PMTube (위치 민감형 광전자증배관을 이용한 영상용 감마프로브의 개발)

  • Bong, Jeong-Gyun;Kim, Hui-Jung;So, Su-Gil;Kim, Han-Myeong;Lee, Jong-Du;Gwon, Su-Il
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.1
    • /
    • pp.107-113
    • /
    • 1999
  • The purpose of this study was to develop a miniature imaging gamma probe with high performance that can detect small or residual tumors after surgery. Gamma probe detector system consists of NaI(Tl) scintillator, position sensitive photomultiplier tube (PSPMT), and collimator. PSPMT was optically coupled with 6.5 mm thick, 7.62 cm diameter of NaI(Tl) crystal and supplied with -1000V for high voltage. Parallel hexagonal hole collimator was manufactured for characteristics of 40-mm hole length, 1.3-mm hole diameter, and 0.22 mm septal thickness. Electronics consist of position and trigger signal readout systems. Position signals were obtained with summing, subtracting, and dividing circuit using preamplifer and amplifier. Trigger signals were obtained using summing amplifier, constant fraction discriminator, and gate and delay generator module with preamplifer. Data acquisition and processing were performed by Gamma-PF interface board inserted into pentium PC and PIP software. For imaging studies, flood and slit mask images were acquired using a point source. Two hole phantom images were also acquired with collimator. Intrinsic and system spatial resolutions were measured as 3.97 mm and 5.97 mm, respectively. In conclusion, Miniature gamma probe images based on the PSPMT showed good image quality, we conclude that the miniature imaging gamma probe was successfully developed and good image data were obtained. However, further studies will be required to optimize imaging characteristics.

  • PDF

Alveolar bone thickness and fenestration of incisors in untreated Korean patients with skeletal class III malocclusion: A retrospective 3-dimensional cone-beam computed tomography study

  • Oh, Song Hee;Nahm, Kyung-Yen;Kim, Seong-Hun;Nelson, Gerald
    • Imaging Science in Dentistry
    • /
    • v.50 no.1
    • /
    • pp.9-14
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate vertical bone loss and alveolar bone thickness in the maxillary and mandibular incisors of patients with skeletal class III malocclusion. This study also aimed to evaluate the periodontal condition of class III malocclusion patients who had not undergone orthodontic treatment. Materials and Methods: The sample included cone-beam computed tomography scans of 24 Korean subjects (3 male and 21 female). Alveolar bone thickness (ABT), alveolar bone area (ABA), alveolar bone loss (ABL), and fenestration of the maxillary and mandibular incisors were measured using 3-dimensional imaging software. Results: All incisors displayed an ABT of less than 1.0 mm from the labial surface to root level 7 (70% of the root length). A statistically significant difference was observed between the mandibular labial and lingual ABAs and between the maxillary labial and mandibular labial ABAs. The lingual ABA of the mandibular lateral incisors was larger than that of the mandibular central incisors. ABL was severe on the labial surface. A statistically significant difference was observed between the maxillary and mandibular labial ABL values(21.8% and 34.4%, respectively). Mandibular lingual ABL (27.6%) was significantly more severe than maxillary lingual ABL (18.3%) (P<0.05). Eighty-two fenestrations were found on the labial surfaces of the incisors, while only 2 fenestrations were observed on the lingual surfaces. Fenestrations were most commonly observed at root level 6. Conclusion: Careful evaluation is needed before orthodontic treatment to avoid iatrogenic damage of periodontal support when treating patients with class III malocclusion.

Characteristic Changes Observation of N-isopropylacrylamide Phantom by Repeated Ultrasound Irradiation (초음파 반복 조사에 따른 NIPAM 팬텀의 특성 변화 관찰)

  • Kim, Ju-Young;Kim, Jae-Young;Noh, Si-Cheol;Choi, Heung-Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.7
    • /
    • pp.509-513
    • /
    • 2015
  • In this study, we evaluated the thermal denaturation characteristics of reusable NIPAM tissue mimicking (TM) Phantom by measuring the thermal sensitivity. And the changes of acoustic characteristic and thermal denaturation shape in NIPAM TM phantom according to the number of re-use time and re-use period were observed. With the result, as the sonication time is increased, the sound velocity of NIPAM phantom was decreased by 100 m/s and the attenuation was increased slightly. However, the changes according to the re-use period was not observed. In the thermal denaturation shape and size observation by ultrasound sonicaton, the remarkable changes have not been confirmed. With the result of this study, NIPAM Phantom was considered appropriate to evaluate and predict the effect of therapeutic ultrasound by in repeated sonication test.