• Title/Summary/Keyword: Radiology department

Search Result 9,234, Processing Time 0.047 seconds

Protective Effects of 5-Androstendiol (5-AED) on Radiation-induced Intestinal Injury (방사선에 의한 장점막 손상에 대한 5-Androstenediol의 보호효과)

  • Kim, Joong-Sun;Lee, Seung-Sook;Jang, Won-Suk;Lee, Sun-Joo;Park, Sun-Hoo;Cho, Soo-Youn;Moon, Chang-Jong;Kim, Sung-Ho;Kim, Mi-Sook
    • Radiation Oncology Journal
    • /
    • v.28 no.3
    • /
    • pp.141-146
    • /
    • 2010
  • Purpose: We examined the radioprotective effects of 5-androstendiol (5-AED), a natural hormone produced in the reticularis of the adrenal cortex, as a result of intestinal damage in gamma-irradiated C3H/HeN mice. Materials and Methods: Thirty mice (C3H/HeN) were divided into three groups; 1) non-irradiated control group, 2) irradiated group, and 3) 5-AED-treated group prior to irradiation. Next, 5-AED (50 mg/kg per body weight) was subcutaneously injected 24 hours before irradiation. The mice were whole-body irradiated with 10 Gy for the histological examination of jejunal crypt survival and the determination of the villus morphology including crypt depth, crypt size, number of villi, villus height, and length of basal lamina, as well as 5 Gy for the detection of apoptosis. Results: The 5-AED pre-treated group significantly increased the survival of the jejunal crypt, compared to irradiation controls (p<0.05 vs. irradiation controls at 3.5 days after 10 Gy). The evaluation of morphological changes revealed that the administration of 5-AED reduced the radiation-induced intestinal damages such as villus shortening and increased length of the basal lamina of enterocytes (p<0.05 vs irradiation controls on 3.5 day after 10 Gy, respectively). The administration of 5-AED decreased the radiation-induced apoptosis in the intestinal crypt, with no significant difference between the vehicle and 5-AED at 12 hours after 5 Gy. Conclusion: The results of this study suggest that the administration of 5-AED has a protective effect on intestinal damage induced by $\gamma$-irradiation. In turn, these results suggest that 5-AED could be a useful candidate for radioprotection against intestinal mucosal injury following irradiation.

The Characteristics of a Research Network for Radiation Oncology in Korea (방사선종양학 분야의 연구 네트워크 특성 분석)

  • Choi, Jin-Hyun;Park, Seo-Hyun;Kang, Jin-Oh
    • Radiation Oncology Journal
    • /
    • v.28 no.3
    • /
    • pp.184-191
    • /
    • 2010
  • Purpose: To evaluate the structural characteristics of a scientific network of radiation oncology society. Materials and Methods: A total of 1,512 articles published from 1986 to April 2010 with the terms 'radiation oncology' or 'therapeutic radiology' were obtained in the KoreaMed database. The co-authors were analyzed according to their affiliation, and their relationship was used to build a matrix. With the matrix, centralization indices and the Key Player index were analyzed. We used UCINET 6.0 for the network analysis, Netdraw for determining a sociogram and Key Player 1.44 for the key player analysis. Results: The centralization of the radiation oncology field decreased from 8.29% for the period from 1986~1990 to 1.84% from 2006~2010. However, when the Korean Journal of Medical Physics was excluded, centralization increased from 2.32% for the period from 2001~2005 to 3.80% from 2006~2010. This suggested that the communication in the clinical research field of radiation oncology is decreasing. In a node centralization analysis, Seoul National University was found to be the highest at 7.9%. Seoul National University showed the highest indices in the Outdegree (6.50%) and Indegree (8.54%), in addition to Betweenness (14.94%) and Eigenvector (135.234%). The Key Player analysis indicated that Inha University had the highest index at 0.491, but when the Korean Journal of Medical Physics was excluded, Yonsei University had the highest Key Player index at 0.584. Conclusion: The degree centrality in the network of radiation oncology decreased in the most recent period as more institutions are participating in network. However, the Betweenness centrality is still increasing, suggesting that the communications among research groups (clique) in radiation oncology is warranted.

The Efficacy of Endovascular Treatment for Deep Vein Thrombosis (하지 심부정맥 혈전증에서 중재적 치료의 유용성)

  • Kim, Seon-Hee;Chung, Sung-Woon;Kim, Chang-Won
    • Journal of Chest Surgery
    • /
    • v.43 no.3
    • /
    • pp.266-272
    • /
    • 2010
  • Background: Deep vein thrombosis (DVT) is a serious disease that causes life-threatening pulmonary embolism and chronic venous insufficiency. Anticoagulation is the standard therapy for DVT. However, the results of standard anticoagulation for treating DVT have been disappointing, so endovascular treatment is commonly performed nowadays. The aim of this study was to evaluate the efficacy of an endovascular procedure for treating patients with DVT. Material and Method: We retrospectively evaluated the clinical data of 29 DVT patients who underwent an endovascular procedure between December 2006 and July 2008. We compared the results of the 29 patients with the results of another 45 patients who were treated with only aspirin and heparin. Result: The patient’s mean age was 55.4 years in the intervention group and 53.7 years in the control group. DVT occurred more frequently in the females. Catheter-directed thrombolysis was performed in 22 patients (75.8%). Aspiration thrombectomy was performed in 18 patients (62%) and a endovascular stent was placed in 25 patients (86.2%). Fifteen patients (51.7%) underwent percutaneous insertion of a retrievable IVC filter for the prevention of pulmonary embolism. In the control group, thirty nine patients (86.7%) were treated with low-molecular heparin, and seven patients (15.6%) who were contraindicated for warfarin were treated with aspirin. No bleeding complications occurred during thrombolysis or anticoagulation. We analyzed the statistical data according to recurrence of DVT and the incidence of post-thrombotic syndrome (PTS) during the follow-up period. The intervention group had a significantly lower incidence of PTS (p-value=0.008), but they had the same result as the control group for the recurrence of DVT. In addition, death from the DVT did not occur in the intervention group. Thus, we obtained better clinical outcomes in the intervention group as compared to those in the anticoagulation only group. Conclusion: Endovascular procedures are effective alternative modalities, as compared to systemic anticoagulation, for the treatment of DVT. But more studies are needed to determine the specific indications and to validate the long-term efficacy of endovascular procedures for the treatment of DVT.

Reducing of Craniofacial Radiation Dose Using Automatic Exposure Control Technique in the 64 Multi-Detector Computed Tomography (64 다중 검출기 전산화단층촬영에서 관전류 자동노출조절 기법을 이용한 두개부 방사선량 감소 정도 평가)

  • Seoung, Youl-Hun;Kim, Yong-Ok;Choe, Bo-Young
    • Progress in Medical Physics
    • /
    • v.21 no.2
    • /
    • pp.137-144
    • /
    • 2010
  • The purpose of this study was to evaluate the usefulness of reducing of craniofacial radiation dose using automatic exposure control (AEC) technique in the 64 multi-detector computed tomography (MDCT). We used SOMATOM Definition 64 multi-detector CT, and head of whole body phantom (KUPBU-50, Kyoto Kagaku CO. Ltd). The protocol were helical scan method with 120 kVp, 1 sec of rotation time, 5 mm of slice thickness and increment, 250 mm of FOV, $512{\times}512$ of matrix size, $64{\times}0.625\;mm$ of collimation, and 1 of pitch. The evaluation of dose reducing effect was compared the fixed tube current of 350 with AEC technique. The image quality was measured the noise using standard deviation of CT number. The range of craniofacial bone was to mentum end from calvaria apex, which devided three regions: calvaria~superciliary ridge (1 segment), superciliary ridge~acanthion (2 segment), and acanthion~mentum (3 segment). In the fixed tube current technique, CTDIvol was 57.7 mGy, DLP was $640.2\;mGy{\cdot}cm$ in the all regions. The AEC technique was showed that 1 segment were 30.7 mGy of CTDIvol, 340.7 $mGy{\cdot}cm$ of DLP, 2 segment were 46.5 mGy of CTDIvol, $515.0\;mGy{\cdot}cm$ of DLP, and 3 segment were 30.3 mGy of CTDIvol, $337.0\;mGy{\cdot}cm$ of DLP. The standard deviation of CT number was 2.622 with the fixed tube current technique and 3.023 with the AEC technique in the 1 segment, was 3.118 with the fixed tube current technique and 3.379 with the AEC technique in the 2 segment, was 2.670 with the fixed tube current technique and 3.186 with the AEC technique in the 3 segment. The craniofacial radiation dose using AEC Technique in the 64 MDCT was evaluated the usefulness of reducing for the eye, the parotid and thyroid with high radiation sensitivity particularly.

Evaluation of Radiation Shielding Rate of Lead Aprons in Nuclear Medicine (핵의학과에서 사용하는 납 앞치마의 방사선 차폐율 평가)

  • Han, Sang-Hyun;Han, Beom-Heui;Lee, Sang-Ho;Hong, Dong-Heui;Kim, Gi-Jin
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.41-47
    • /
    • 2017
  • Considering that the X-ray apron used in the department of radiology is also used in the department of nuclear medicine, the study aimed to analyze the shielding rate of the apron according to types of radioisotopes, thus ${\gamma}$ ray energy, to investigate the protective effects. The radioisotopes used in the experiment were the top 5 nuclides in usage statistics $^{99m}Tc$, $^{18}F$, $^{131}I$, $^{123}I$, and $^{201}Tl$, and the aprons were lead equivalent 0.35 mmPb aprons currently under use in the department of nuclear medicine. As a result of experiments, average shielding rates of aprons were $^{99m}Tc$ 31.59%, $^{201}Tl$ 68.42%, and $^{123}I$ 76.63%. When using an apron, the shielding rate of $^{131}I$ actually resulted in average dose rate increase of 33.72%, and $^{18}F$ showed an average shielding rate of -0.315%, showing there was almost no shielding effect. As a result, the radioisotopes with higher shielding rate of apron was in the descending order of $^{123}I$, $^{201}Tl$, $^{99m}Tc$, $^{18}F$, $^{131}I$. Currently, aprons used in the nuclear medicine laboratory are general X-ray aprons, and it is thought that it is not appropriate for nuclear medicine environment that utilizes ${\gamma}$ rays. Therefore, development of nuclear medicine exclusive aprons suitable for the characteristics of radioisotopes is required in consideration of effective radiation protection and work efficiency of radiation workers.

Differential Diagnosis of Metastatic Bone Disease and Benign Bone Disease on Spine SPECT in Patients with Low Back Pain (요통 환자의 척추골 SPECT에서 골전이 병변과 양성골질환의 섭취 양상 분석을 통한 감별진단이 가능한가)

  • Lee, Seung-Hun;Choi, Yun-Young;Cho, Suk-Shin
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.6
    • /
    • pp.371-377
    • /
    • 2001
  • Purpose: One or more abnormal vertebrae detected on bone scintigraphy is a common finding in clinical practice, and it could pose a diagnostic dilemma especially in cancer patients. as either metastasis or benign disease may cause scintigraphic abnormality. The purpose of this study was to determine whether additional spine SPECT has a role in differentiating malignant from benign lesions in patients with back pain. Materials and Methods: We reviewed spine SPECT studios obtained over a three-year period in 108 patients. Among them, forty-five patients with abnormal SPECT and clinically followed records were evaluated (20 cancer patients were included). Uptake patterns were classified as follows: 1. Body: diffusely increased uptake, linear increased uptake of end plate, segmental increased uptake, and cold defect, 2. Posterior element: posterior to body (pedicle), posterior to Intervertebral disc space (facet joint), and spinous process. Lesions were correlated with radiological findings and with final diagnosis. Results: Sixty-nine bone lesions were detected on SFECT images, including 18 metastases, 28 degenerative diseases and 21 compression fractures. Cold defect (6) and segmental increased uptake (5) were dominant findings in metastasis; linear increased uptake (12), and facet joint uptake (15) were in degenerative change; and diffuse increased uptake (9), and linear increased uptake (9) were in compression fracture. Conclusion: Cold defect and segmental increased uptake of body were characteristic findings of metastasis, but care should be taken because compression fracture also shows segmental increased uptake in some cases. Degenerative disease was easily diagnosed because of the typical finding of linear increased uptake of end plate and facet joint. Therefore, additional bone SPECT after planar bone scan would be helpful for differentiating metastasis from benign condition in cancer patients.

  • PDF

The Role of Radiotherapy in the Management of Supratentorial Low Grade Astrocytoma (천막 상부 저분화 성상세포종의 치료에 있어 방사선 치료의 역할)

  • Lee, Kyung-Ja;Chang, Hye-Sook;Song, Mi-Hee
    • Radiation Oncology Journal
    • /
    • v.15 no.1
    • /
    • pp.1-10
    • /
    • 1997
  • Purpose : To evaluate the role of radiotherapy in the management of incompletely resected supratentorial low grade astrocytoma with the analysis of the survival, the Pattern of failure, and the prognostic variables affecting survival. Material and methods : Between January 1990 and December 1995, fifty-one patients with supratentorial low grade astrocytoma received radiotherapy after subtotal resection(16 patients) or stereotactic biopsy(35 patients) at Asan Medical Center, External radiotherapy was done by conventional fractionation with the total dose of 4820cGy to 6000cGy(median 5580cGy) and partial brain volume. The follow-up was done from 6 to 79 months(median 48 months) Result : Overall actuarial survival rate at 2 and 5 years were $83.4\%\;and\;54.8\%$, respectively. Progression free survival at 2 and 5 years were $67.4\%\;and\;48.7\%$, respectively The significant prognostic factors affecting overall survival rate were the performance status, 1 stage, histologic subtype, radiation field and radiation response. The major pattern of failure was local failure, such as Progressive disease and primary site recurrence in 23 patients $(45.1\%)$. Progression free survivors excluding 2 patients were physically and intellectually intact without major neurologic deficit. Conclusion : Although the follow-up period of this study was relatively short, overall actuarial and progression free survival rate were encouraging. Patients with good performance status, lower T stage, pilocytic subtype, patients treated with small radiation field and radiation responder showed better survival. As the local failure was the major pattern of failure, the various efforts to decrease the local failure is necessary.

  • PDF

Pre-operative Concurrent Chemoradiotherapy for Stage IlIA (N2) Non-Small Cell Lung Cancer (N2 병기 비소세포 폐암의 수술 전 동시화학방사선요법)

  • Lee, Kyu-Chan;Ahn, Yong-Chan;Park, Keunchil;Kim, Kwhan-Mien;Kim, Jhin-Gook;Shim, Young-Mog;Lim, Do-Hoon;Kim, Moon-Kyung;Shin, Kyung-Hwan;Kim, Dae-Yong;Huh, Seung-Jae;Rhee, Chong-Heon;Lee, Kyung-Soo
    • Radiation Oncology Journal
    • /
    • v.17 no.2
    • /
    • pp.100-107
    • /
    • 1999
  • Purpose: This is to evaluate the acute complication, resection rate, and tumor down-staging after pre-operative concurrent chemoradiotherapy for stage IIIA (N2) non-small cell lung cancer. Materials and Methods Fifteen patients with non-small cell lung cancer were enrolled in this study from May 1997 to June 1998 in Samsung Medical Center. The median age of the patients was 61 (range, 45~67) years and male to female ratio was 12:3. Pathologic types were squamous cell carcinoma (11) and adenocarcinoma (4). Pre-operative clinical tumor stages were cT1 in 2 patients, cT2 in T2, and cT3 in 1 and all were N2. Ten patients were proved to be N2 with mediastinoscopic biopsy and five had clinically evident mediastinal Iymph node metastases on the chest CT scans. Pre-operative radiation therapy field included the primary tumor, the ipsilateral hilum, and the mediastinum. Total radiation dose was 45 Gy over 5 weeks with daily dose of 1.8 Gy. Pre-operative concurrent chemotherapy consisted of two cycles of intravenous cis-Platin (100 mg/m$^{2}$) on day 1 and oral Etoposide (50 mg/m$^{2}$/day) on days 1 through 14 with 4 weeks' interval. Surgery was followed after the pre-operative re-evaluation including chest CT scan in 3 weeks of the completion of the concurrent chemoradiotherapy if there was no evidence of disease progression. Results : Full dose radiation therapy was administered to all the 15 patients. Planned two cycles of chemotherapy was completed in 11 patients and one cycle was given to four. One treatment related death of acute respiratory distress syndrome occurred In 15 days of surgery. Hospital admission was required in three patients including one with radiation pneumonitis and two with neutropenic fever. Hematologic complications and other acute complications including esophagitis were tolerable. Resection rate was 92.3% (12/l3) in 13 patients excluding two patients who refused surgery. Pleural seeding was found in one patient after thoracotomy and tumor resection was not feasible. Post-operative tumor stagings were pT0 in 3 patients, pTl in 6, and pT2 in 3. Lymph node status findings were pN0 in 8 patients, pN1 in 1, and pN2 in 3. Pathologic tumor down-staging was 61.5% (8/13) including complete response in three patients ($23.7%). Tumor stage was unchanged in four patients (30.8%) and progression was in one (7.7%). Conclusions : Pre-operative concurrent chemoradiotherapy for Stage IIIA (N2) non-small cell lung cancer demonstrated satisfactory results with no increased severe acute complications. This treatment shceme deserves more patinet accrual with long-term follow-up.

  • PDF

The difference of image quality using other radioactive isotope in uniformity correction map of myocardial perfusion SPECT (심근 관류 SPECT에서 핵종에 따른 Uniformity correction map 설정을 통한 영상의 질 비교)

  • Song, Jae hyuk;Kim, Kyeong Sik;Lee, Dong Hoon;Kim, Sung Hwan;Park, Jang Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.87-92
    • /
    • 2015
  • Purpose When the patients takes myocardial perfusion SPECT using $^{201}Tl$, the operator gives the patients an injection of $^{201}Tl$. But the uniformity correction map in SPECT uses $^{99m}Tc$ uniformity correction map. Thus, we want to compare the image quality when it uses $^{99m}Tc$ uniformity correction map and when it uses $^{201}Tl$ uniformity correction map. Materials and Methods Phantom study is performed. We take the data by Asan medical center daily QC condition with flood phantom including $^{201}Tl$ 21.3 kBq/mL. After postprocessing with this data, we analyze CFOV integral uniformity(I.U) and differential uniformity(D.U). And we take the data with Jaszczak ECT Phantom by American college of radiology accreditation program instruction including $^{201}Tl$ 33.4 kBq/mL. After post processing with this data, we analyze spatial Resolution, Integral Uniformity(I.U), coefficient of variation(C.V) and Contrast with Interactive data language program. Results In the flood phantom test, when it uses $^{99m}Tc$ uniformity correction map, Flood I.U is 3.6% and D.U is 3.0%. When it uses $^{201}Tl$ uniformity correction map, Flood I.U is 3.8% and D.U is 2.1%. The flood I.U is worsen about 5%, but the D.U is improved about 30% inversely. In the Jaszczak ECT phantom test, when it uses $^{99m}Tc$ uniformity correction map, SPECT I.U, C.V and contrast is 13.99%, 4.89% and 0.69. When it uses $^{201}Tl$ uniformity correction map, SPECT I.U, C.V and contrast is 11.37%, 4.79% and 0.78. All of data are improved about 18%, 2%, 13% The spatial resolution was no significant changes. Conclusion In the flood phantom test, Flood I.U is worsen but Flood D.U is improved. Therefore, it's uncertain that an image quality is improved with flood phantom test. On the other hand, SPECT I.U, C.V, Contrast are improved about 18%, 2%, 13% in the Jaszczak ECT phantom test. This study has limitations that we can't take all variables into account and study with two phantoms. We need think about things that it has a good effect when doctors decipher the nuclear medicine image and it's possible to improve the image quality using the uniformity correction map of other radionuclides other than $^{99m}Tc$, $^{201}Tl$ when we make other nuclear medicine examinations.

  • PDF

Correlation analysis of radiation therapy position and dose factors for left breast cancer (좌측 유방암의 방사선치료 자세와 선량인자의 상관관계 분석)

  • Jeon, Jaewan;Park, Cheolwoo;Hong, Jongsu;Jin, Seongjin;Kang, Junghun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.1
    • /
    • pp.37-48
    • /
    • 2017
  • Purpose: The most basic conditions of radiation therapy is to prevent unnecessary exposure of normal tissue. The risk factors that are important o evaluate the dose emitted to the lung and heart from radiation therapy for breast cancer. Therefore, comparing the dose factors of a normal tissue according to the radion treatment position and Seeking an effective radiation treatment for breast cancer through the analysis of the correlation relationship. Materials and Methods: Computed tomography was conducted among 30 patients with left breast cancer in supine and prone position. Eclipse Treatment Planning System (Ver.11) was established by computerized treatment planning. Using the DVH compared the incident dose to normal tissue by position. Based on the result, Using the SPSS (ver.18) analyzed the dose in each normal tissue factors and Through the correlation analysis between variables, independent sample test examined the association. Finally The HI, CI value were compared Using the MIRADA RTx (ver. ad 1.6) in the supine, prone position Results: The results of computerized treatment planning of breast cancer in the supine position were V20, $16.5{\pm}2.6%$ and V30, $13.8{\pm}2.2%$ and Mean dose, $779.1{\pm}135.9cGy$ (absolute value). In the prone position it showed in the order $3.1{\pm}2.2%$, $1.8{\pm}1.7%$, $241.4{\pm}138.3cGy$. The prone position showed overall a lower dose. The average radiation dose 537.7 cGy less was exposured. In the case of heart, it showed that V30, $8.1{\pm}2.6%$ and $5.1{\pm}2.5%$, Mean dose, $594.9{\pm}225.3$ and $408{\pm}183.6cGy$ in the order supine, prone position. Results of statistical analysis, Cronbach's Alpha value of reliability analysis index is 0.563. The results of the correlation analysis between variables, position and dose factors of lung is about 0.89 or more, Which means a high correlation. For the heart, on the other hand it is less correlated to V30 (0.488), mean dose (0.418). Finally The results of independent samples t-test, position and dose factors of lung and heart were significantly higher in both the confidence level of 99 %. Conclusion: Radiation therapy is currently being developed state-of-the-art linear accelerator and a variety of treatment plan technology. The basic premise of the development think normal tissue protection around PTV. Of course, if you treat a breast cancer patient is in the prone position it take a lot of time and reproducibility of set-up problems. Nevertheless, As shown in the experiment results it is possible to reduce the dose to enter the lungs and the heart from the prone position. In conclusion, if a sufficient treatment time in the prone position and place correct confirmation will be more effective when the radiation treatment to patient.

  • PDF