• Title/Summary/Keyword: Radiology department

Search Result 9,234, Processing Time 0.037 seconds

A Comparative Study of Influencing BMD Factors in Postpartum and General Women in Their Twenties and Thirties ($20{\sim}30$대 여성의 골밀도 영향 인자에 대한 출산 후 여성과 일반여성과의 비교 연구)

  • Kim, Sun-Geun;Oh, Chan-Ho;Kweon, Dae-Cheol
    • Journal of radiological science and technology
    • /
    • v.30 no.1
    • /
    • pp.25-32
    • /
    • 2007
  • This study is to evaluate the factors that affect to the bone mineral density(BMD) of postpartum women by comparing BMD between postpartum and general women who are ages from 20 to 39, and to identify correlation between various factors weight, height, body mass index(BMI), hemoglobin(Hb) and BMD. Study subjects were postpartum(n=159) and general(n=180) women. We checked the BMD of femoral neck and lumbar spine by using dual energy X-ray bone densitometry. The mean age was $30.69{\pm}3.32$ in postpartum care group and $31.22{\pm}5.66$ in general women group. In postpartum care group, the mean BMD of femoral neck and lumbar spine were -0.187 and -0.076. In general women group, the mean BMD of femoral neck and lumbar spine were -0.029, and -0.169. According to BMI level, each group was divided into two subgroups. One was 23 or more BMI subgroup, and the other was under 23 BMI subgroup. There was a significant difference in BMD of femoral neck and lumbar spine between two subgroups in general women group, but only a significant difference in BMD of lumbar spine is noted between two subgroups of postpartum group. According to Hb level, each group was divided into two subgroups. One was 11g/dl or more subgroup, and the other was under 11g/dl subgroup. There was not a statistically significant difference of BMD in all subgroups. BMD of femoral neck and lumbar spine showed a significant correlation with weight, height, BMI in both groups. There was a significant correlation between BMD and Hb level in postpartum care group, but a significant correlation was not noted in general women group. The postpartum women showed a significant correlation between BMD and various factors such as weight, height, BMI just like in general women. There was a significant correlation between BMD and Hb in postpartum women, but not in general women.

  • PDF

Effect of Radiation Dose for Radiotherapy on Ovarian Follicle Atresia in Rat (치료 방사선량이 쥐의 난포 퇴축에 미치는 영향)

  • Lee, Won-Jeong;Seon, Jong-Ryul;Yoo, Se-Jong;Ahn, Bong-Seon
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.4
    • /
    • pp.208-212
    • /
    • 2012
  • In previous studies, ovarian follicle in rat has been used a higher radiation dose than that for cancer radiotherapy in clinical practice. The aim of this study was to evaluate the effect of radiation dose used for cancer radiotherapy on ovarian follicle atresia in rat. Mice of 4-week-old female were whole body irradiated with 2 cGy or 2 Gy (Mevatron 67, Siemens, Germany) and sacrificed by cervical dislocation. Ovaries were collected at 24 hours after irradiation to observe the degree of follicular atresia. Ovaries were fixed in neutral formaldehyde solution for 24 hours and embedded with paraffin. Cutted in $5{\mu}m$ thickness with microtome and stained with hematoxylin and eosin (H&E) and TUNEL immunohistochemical stain, and examined histologically under a light microscope. All data were presented as mean ${\pm}SD$, calculating the ratio of normal or atretic follicles to total ovarian follicles. Statistical analysis was performed by the Mann Whitney test using the SPSS ver 19.0. Ratio of atretic to total follicles of 2 Gy group was significantly higher than control or 2 cGy groups (p<0.05). Ratio of normal to total follicles of 2 Gy group was significantly lower than control group in preantral follicle (64.0 vs. 87.7, p=0.027). Ratio of normal to total follicles of 2 cGy group was significantly increased more than control or 2 Gy groups in antral follicle, and there were no significant difference between control and 2 Gy groups (p=0.522). Radiation dose of 2 Gy for cancer radiotherapy have a significant effect on ovarian follicle atresia in rat.

Role of FDG-PET in the Diagnosis of Recurrence and Assessment of Therapeutic Response in Cervical Cancer and Ovarian Cancer Patients: Comparison of Diagnostic Report between PET, Abdominal a and Tumor Marker (자궁경부암 및 난소암 환자 재발진단과 치료반응평가에 있어서 FDG-PET의 역할: 양전자방출단층촬영, 복부전산화단층촬영 및 종양표지자 판독의 비교 분석)

  • Han, You-Mie;Choe, Jae-Gol;Kang, Bung-Chul
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.3
    • /
    • pp.201-208
    • /
    • 2008
  • Purpose: We aimed to assess the role of positron emission tomography using fluorodeoxyglucose (FDG-PET) in the diagnosis of recurrence or the assessment of therapeutic response in cervical and ovarian cancer patients through making a comparison between FDG-PET, abdominal computed tomography (CT) and serum tumor marker. Materials and methods: We included 103 cases (67 patients) performed FDG-PET and abdominal CT. There were 42 cervical cancers and 61 ovarian cancers. We retrospectively reviewed the interpretations of PET and CT images as well as the level of tumor marker. We calculated their sensitivity, specificity, positive predictive value and negative predictive value for these three modalities. And then we analyzed the differences between these three modalities. Results: Tumor recurrences were diagnosed in 37 cases (11 cervical cancers and 26 ovarian cancers). For PET, CT and tumor marker, in cervical cancer group, sensitivity was 100% (11/11), 54.5% (6/11) and 81.1% (9/11), respectively. And specificity was 93.6% (29/31), 93.6% (29/31) and 100% (31/31). In ovarian cancer group, sensitivity was 96.2% (25/26), 84.6% (22/26) and 80.8% (21/26), and specificity was 94.3% (33/35), 94.3% (33/35), 94.3% (33/35), PET was highly sensitive to detect the intraperitoneal and extraperitoneal metastasis with the help of the CT images to localize the lesions. However, CT had limitations in differentiation of the recurrent tumor from benign fibrotic tissue, identification of viable tumors at the interface of tissues, and detecting extraperitoneal lesions. Conclusion: FDG-PET can be an essential modality to detect the recurrent or residual tumors in gynecologic cancer patients because of its great field of the application and high sensitivity.

Prevalence and Risk Factors of the Gallbladder Polyps Diagnosed by Ultrasound (복부초음파검사로 진단된 담낭용종의 유병률과 위험인자 분석)

  • LEE, Mi-Hwa;Cho, Pyong-Kon;Kwon, Duck-Moon
    • Journal of radiological science and technology
    • /
    • v.38 no.2
    • /
    • pp.127-134
    • /
    • 2015
  • This study was designed to determine the prevalence of gallstones in the last three years and evaluate the associated risk factors in the population who underwent health screening. Although there are many studies reporting the prevalence and risk factors of GB polyp, the results varied among each report. The aims of this study were to evaluate the prevalence rate and risk factors of GB polyp, colon polyp and fatty liver in the population who underwent health screening. The study population consisted of 4,877 visited the health promotion center in Dalseogu, Daegu in Korea from January 2011 to December 2013. Each participant in the study had their biliary system gallbladder examined using ultrasonography. The prevalence of GB polyp was evaluated along with age, gender, metabolic syndrom, body mass index (BMI), Fatty liver, Colon polyp. A showed of total 383 (7.9%) people were found to have GB polyps. The prevalence of sex among 256 (9.8%) patients men and 127 (5.6%) women which showed significantly higher in male than in female subjects(p=0.001). The mean size of the GB polyps 4.92 mm (1.6-17 mm). The sizes of most GB polyps (73.6%) were less than 10 mm in diameter. 122 subjects (31.28%) had multiple GB polyps which 2 or more polyps and 261 subjects (68.2%) had single polyp. Independent risk factors related with GB polyp were male gender (OR 0.551, p<0.001), overweight that BMI above $23kg/m^2$ (OR 0.713, p=0.002) triglyceride (OR 0.571, P<0.001), metabolic syndrome (OR 0.049, p=0.033) and colon polyp (OR 1.409, p=0.002). In spite of the conclusion, the prevalence GB polyp was higher than previous Korea and other country reports. The GB polyp in a healthy population was results as 7.9%. The risk factors of GB polyps were found to be male, being overweight, triglyceride, metabolic syndrome and colon polyp. Not only the subject of a health examination is needed but, a further study of the general public when possible.

Evaluation to Obtain the Image According to the Spatial Domain Filtering of Various Convolution Kernels in the Multi-Detector Row Computed Tomography (MDCT에서의 Convolution Kernel 종류에 따른 공간 영역 필터링의 영상 평가)

  • Lee, Hoo-Min;Yoo, Beong-Gyu;Kweon, Dae-Cheol
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.71-81
    • /
    • 2008
  • Our objective was to evaluate the image of spatial domain filtering as an alternative to additional image reconstruction using different kernels in MDCT. Derived from thin collimated source images were generated using water phantom and abdomen B10(very smooth), B20(smooth), B30(medium smooth), B40 (medium), B50(medium sharp), B60(sharp), B70(very sharp) and B80(ultra sharp) kernels. MTF and spatial resolution measured with various convolution kernels. Quantitative CT attenuation coefficient and noise measurements provided comparable HU(Hounsfield) units in this respect. CT attenuation coefficient(mean HU) values in the water were values in the water were $1.1{\sim}1.8\;HU$, air($-998{\sim}-1000\;HU$) and noise in the water($5.4{\sim}44.8\;HU$), air($3.6{\sim}31.4\;HU$). In the abdominal fat a CT attenuation coefficient($-2.2{\sim}0.8\;HU$) and noise($10.1{\sim}82.4\;HU$) was measured. In the abdominal was CT attenuation coefficient($53.3{\sim}54.3\;HU$) and noise($10.4{\sim}70.7\;HU$) in the muscle and in the liver parenchyma of CT attenuation coefficient($60.4{\sim}62.2\;HU$) and noise ($7.6{\sim}63.8\;HU$) in the liver parenchyma. Image reconstructed with a convolution kernel led to an increase in noise, whereas the results for CT attenuation coefficient were comparable. Image scanned with a high convolution kernel(B80) led to an increase in noise, whereas the results for CT attenuation coefficient were comparable. Image medications of image sharpness and noise eliminate the need for reconstruction using different kernels in the future. Adjusting CT various kernels, which should be adjusted to take into account the kernels of the CT undergoing the examination, may control CT images increase the diagnostic accuracy.

  • PDF

Evaluation of Effective and Organ Dose Using PCXMC Program in DUKE Phantom and Added Filter for Computed Radiography System (CR 환경에서의 흉부촬영 시 Duke Phantom과 부가여과를 이용한 유효선량 및 장기선량 평가)

  • Kang, Byung-Sam;Park, Min-Joo;Kim, Seung-Chul
    • Journal of radiological science and technology
    • /
    • v.37 no.1
    • /
    • pp.7-14
    • /
    • 2014
  • By using a Chest Phantom(DUKE Phantom) focusing on dose reduction of diagnostic radiation field with the most use of artificial radiation, and attempt to reduce radiation dose studies technical radiation. Publisher of the main user of the X-ray Radiological technologists, Examine the effect of reducing the radiation dose to apply additional filtering of the X-ray generator. In order to understand the organ dose and effective dose by using the PC-Based Monte Carlo Program(PCXMC) Program, the patient receives, was carried out this research. In this experiment, by applying a complex filter using a copper and Al(aluminum,13) and filtered single of using only aluminum with the condition set, and measures the number of the disk of copper indicated by DUKE Phantom. The combination of the composite filtration and filtration of a single number of the disk of the copper is the same, with the PCXMC 2.0. Program looking combination of additional filtration fewest absorbed dose was calculated effective dose and organ dose. Although depends on the use mAs, The 80 kVp AP projection conditions, it is possible to reduce the effective amount of about 84 % from about 30 % to a maximum at least. The 120 kVp PA projection conditions, it is possible to reduce the effective amount of about 71 % from about 41 % to a maximum of at least. The organ dose, dose reduction rate was different in each organ, but it showed a decrease of dose rate of 30 % to up 100 % at least. Additional filtration was used on the imaging conditions throughout the study. There was no change in terms of video quality at low doses. It was found that using the DUKE Phantom and PCXMC 2.0 Program were suitable to calculate the effect of reducing the effective dose and organ dose.

Apoptosis and Proliferative Activity of Non-Hodgkin's Lymphoma : Correlation with Bcl-2 and P53 Protein Expression (비호지킨림프종에서 아포프토시스 및 세포증식 : Bcl-2, P53 단백발현과의 관계)

  • Oh, Yoon-Kyeong;Lee, Mi-Ja;Jeon, Ho-Jong
    • Radiation Oncology Journal
    • /
    • v.20 no.1
    • /
    • pp.73-80
    • /
    • 2002
  • Purpose : Tumor growth in a given neoplasm is the net result of cell proliferation and cell loss, and apoptosis is the most significant component of continuous cell loss in most tumors. In this study, we examined non-Hodgkin's lymphoma (NHL, n=67) immunohistochemically for the presence of Bcl-2 oncoprotein and P53 protein and compared apoptotic indices (Als) and Ki-67 proliferative indices (percentages of Ki-67 positive cells). Materials and Methods : 67 patients with NHL were evaluated : 3 low-grade and 64 intermediate-grade. The phenotype was determined in 65 cases : 47 $(70\%)$ were B cell type and 18 $(27\%)$ were T ceil type. Als and Ki-67 proliferative indices were determined immunohistochemically and the overexpression of P53 and Bcl-2 protein were also evalutated. Results : The overexpressions of Bcl-2 protein and P53 protein were found in $40\%$ (26/65) and $31\%$ (20/65). The Al ranged from $0\%\;to\;15\%$ (mean 2.16, median 1.2). Cellular Bcl-2, which counteracts apoptosis, was significantly (p=0.005) associated with Als. Ki-67 proliferative indices ranged from $1\%\;to\;91\%$ (mean 55.4), and P53 was significantly (p=0.000) associated with Ki-67 proliferative indices. A positive correlation between Als and Ki-67 proliferative indices was revealed (p=0.012) in Bcl-2 positive patients. Conclusion : In NHL, we observed a correlation between Als and Bcl-2 expression, between Ki-67 proliferative indices and P53 expression, and between Als and Ki-67 proliferative indices in Bcl-2 positive patients. Our results suggest that cell apoptosis may be inseparable from cell proliferation during tumor growth.

The Usefulness of Measurement of Whole Body Count in Assessing Bone Marrow Metastasis in Cancer Patients with Increased Periarticular Bone Uptake on Follow-up Bone Scan: A Comparison with Bone Marrow Scan (암환자의 추적 골스캔에서 관절주위 섭취증가시 전신골섭취계수 측정이 골수전이 평가에 도움이 되는가-골수스캔과의 비교)

  • Jin, Seong-Chan;Choi, Yun-Young;Cho, Suk-Shin
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.6
    • /
    • pp.428-436
    • /
    • 2003
  • Purpose: Increased periarticular uptake could be associated with peripheral bone marrow expansion in cancer patients with axial bone marrow metastasis. We compared bone scan and bone marrow scan to investigate whether the increased whole body count in patients with increased periarticular uptake on bone scan is useful in the diagnosis of axial marrow metastasis, and evaluate the role of additional bone marrow scan in these cases. Materials and methods: Twelve patients with malignant diseases who showed increased periarticular uptake on bone scan were included. Whole body count was measured on bone scan and it is considered to be increased when the count is more than twice of other patients. Bone marrow scan was taken within 3-7 days. Results: Five hematologic malignancy, 3 stomach cancer, 2 breast cancer, 1 prostate cancer and 1 lung cacner were included. All three patients with increased whole body count on bone scan showed axial marrow suppression and peripheral marrow expansion. Eight of 9 patients without increased whole body count showed axial marrow suppression and peripheral marrow expansion. One turned out to be blastic crisis of chronic myelogeneous leukemia, and seven showed normal axial marrow with peripheral marrow expansion in chronic anemia of malignancy. The last one without increased whole body count showed normal bone marrow scan finding. Conclusion: Increased whole body count on bone scan could be a clue to axial bone marrow metastasis in cancer patients with increased periarticular uptake, and bone marrow scan is a valuable method for differential diagnosis in these cases.

A Study of Factors Affecting Measurement of Kidney Size in Ultrasonography (초음파로 신장의 크기 측정 시 미치는 영향에 관한 연구)

  • Yoon, Seok-Hwan;Kim, Yun-Min;Choi, Jun-Gu
    • Journal of radiological science and technology
    • /
    • v.31 no.2
    • /
    • pp.161-169
    • /
    • 2008
  • Since measuring the size of kidney with sonography becomes an important index for diagnosis, treatment, and prognostic prediction in kidney disease, the accurate measurement and evaluation on this are clinically very important. Accordingly, the purpose of this study was to increase reproducibility and objectivity in measuring the size of kidney by enumerating factors that have an impact for measurement. It targeted 44 adults in Korea at the age of 21-27. It measured in order for both kidneys to be seen most largely while changing a subject-examiner's position in a state of fasting for 8 hours and a transducer's approaching direction. It compared a size of kidney by measuring, respectively, with the same method in 30 minutes and in 1 hour after drinking water in 700-1,000cc. In case of the lateral approach scan in decubitus position, the average length of the kidney both to the right and the left and the deviation of measurement to be the largest. In NPO(None Per Oral) state, the average length in the right kidney was 10.19cm, and the average length in the left kidney was 10.33cm. In 60 minutes after taking moisture, the average length in the right kidney was 10.94cm, and the average length in the left kidney was 11.13cm. In comparing the average length of the kidney in NPO state and its average length in 60 minutes after taking moisture, the size swelled by 7.3% for the length in the right kidney and by 7.7% in the left, thereby having been indicated to be statistically significant(P<0.003). The measurement in a size of kidney by using ultrasound may be measured differently depending on a patient's state of taking moisture and a transducer's approaching direction. It is thought that when the measurement in a size of kidney is especially important clinically, the intake and intake time in moisture need to be considered and that measuring with the posterior approach in prone position is a good method aiming to increase reproducibility in measuring length of the kidney.

  • PDF

Evaluation of Magnetization Transfer Ratio Imaging by Phase Sensitive Method in Knee Joint (슬관절 부위에서 자화전이 위상감도법에 의한 자화전이율 영상 평가)

  • Yoon, Moon-Hyun;Seung, Mi-Sook;Choe, Bo-Young
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.269-275
    • /
    • 2008
  • Although MR imaging is generally applicable to depict knee joint deterioration it, is sometimes occurred to mis-read and mis-diagnose the common knee joint diseases. In this study, we employed magnetization transfer ratio (MTR) method to improve the diagnosis of the various knee joint diseases. Spin-echo (SE) T2-weighted images (TR/TE 3,400-3,500/90-100 ms) were obtained in seven cases of knee joint deterioration, FSE T2-weighted images (TR/TE 4,500-5,000/100-108 ms) were obtained in seven cases of knee joint deterioration, gradient-echo (GRE) T2-weighted images (TR/TE 9/4.56/$50^{\circ}$ flip angle, NEX 1) were obtained in 3 cases of knee joint deterioration, In six cases of knee joint deterioration, fat suppression was performed using a T2-weighted short T1/tau inverse recovery (STIR) sequence (TR/TE =2,894-3,215 ms/70 ms, NEX 3, ETL 9). Calculation of MTR for individual pixels was performed on registration of unsaturated and saturated images. After processing to make MTR images, the images were displayed in gray color. For improving diagnosis, three-dimensional isotropic volume images, the MR tristimulus color mapping and the MTR map was employed. MTR images showed diagnostic images quality to assess the patients' pathologies. The intensity difference between MTR images and conventional MRI was seen on the color bar. The profile graph on MTR imaging effect showed a quantitative measure of the relative decrease in signal intensity due to the MT pulse. To diagnose the pathologies of the knee joint, the profile graph data was shown on the image as a small cross. The present study indicated that MTR images in the knee joint were feasible. Investigation of physical change on MTR imaging enables to provide us more insight in the physical and technical basis of MTR imaging. MTR images could be useful for rapid assessment of diseases that we examine unambiguous contrast in MT images of knee disorder patients.

  • PDF