병(病)-의원(醫院)의 X선촬영업무(線撮影業務)에 관한 실태조사(實態調査) (Survey on Radiographic Works in Hospitals and Clinics)

  • 최종학;전만진;박성옥;임한영;김건중;허준;최종운
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제7권1호
    • /
    • pp.3-11
    • /
    • 1984
  • The major findings of this investigation on radiographic works in 125 medical institutions around Seoul and Kyung-Ki area, from March 1983 to February 1984, are summarized as follows. 1. The number of references provided on radiographic techniques were 3 to 5 in general hospitals (52.1%), in hospitals (58.5%), and clinics (44.5%), and only the 10.4% of general hospitals had 11 or more. 2. The relatively high percentages of 75.0% of general hospitals and 68.3% of hospitals have established the standardized radiographic methods for regions examined, but most clinics (61.1%) have not. 3. As a log system for the radiographic request, the method of "routine study, or all the x-ray examinations are marked as 0 on a printed form" was most commonly used by general hospitals (62.5%) and hospitals (51.2%), and "the doctors employ their own methods" in most clinics (44.6%). 4. In the 85.4% of general hospitals, the 68.3% of hospitals and the 38.9% of clinics, the data such as diagnosis, clinic history, purpose of x-ray examination were recorded on a radiographic request at all times, or at least in part. 5. On a scale of hardness and easiness of order of doctors, the greatest response was "fairly easy to understand", and the 37.5% of general hospitals responded as "sometimes hard". 6. In determining the standards for radiographic factors, the general hospitals (62.5%) and hospitals (65.9%) adapted mostly "a departmental check list", and the clinics (61.1%) used mainly "a personal decision". 7. In using the immobilizing devices, angligner, and radiographic accessories, the Percentages were high in general hospitals and hospitals on the one hand, and were low in clinics on the other. 8. A consideration with regard to the devices for an improvement of examination of the same patients was totally ignored by the 50.0% of clinics, the 26.8% of hospitals and the 20.8% of general hospitals. 9. The causes of re-examination were due largely to patients (33.6%), and followed proportionately by incorrect exposure (22.8%), errors in positioning (22.0%), film processing faults (9.2%), conditions of x-ray equipments (8.8%), and quality of x-ray films (3.6%). 10. The conference on radiography was conducted regularly or irregularly by the 87.5% of general hospitals, the 56.1% of hospitals, and the 27.7% of clinics, and the meeting was proceeded only by radiologic technologists.

  • PDF

유방촬영술에서 압력과 두께 측정 (Measurement of the Compression Force and Thickness applied during Mammography)

  • 권대철;이은미;박범
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제26권2호
    • /
    • pp.29-35
    • /
    • 2003
  • 한국의 유방 질환에 대한 유방촬영술의 방법은 서구의 방법과는 연령에 따라 다양하고 신중하게 시행되어야 한다. 유방암 발생율이 급속히 증가되면서 조기진단을 목적으로 유방촬영술의 검사건수가 증가되어가고 있다. 우리나라 여성의 30세 이상 60세 이하를 대상으로 유방촬영술이 내사위촬영과 상하촬영에서 유방의 두께와 압력을 측정하였다. 유방촬영술에 필요한 압력과 두께의 기초 자료를 제공하여, 선예도와 해상력이 높은 진단적 가치가 있는 영상을 만드는데 목적을 두고자 한다. 204명을 대상으로 한 연령대별의 분포에서 30대는 64명(31.4%), 40대와 50대는 70명(34.3%)이었다. 압력에서 내사위촬영과 상하촬영 모두 50대가 가장 높았고, 40대, 30대 순으로 측정되었다. 전체 평균은 내사위촬영 14 daN, 상하촬영 13.88 daN으로 내사위촬영이 조금 높았다. 두께에서는 내사위촬영과 상하촬영 모두에서 50대가 40대, 30대에 비해 두껍게 측정되었고, 전체 평균은 내사위촬영 41.46 mm, 상하촬영 39.50 mm로 내사위촬영이 상하촬영보다 두꺼웠다.

  • PDF

디지털 X선 촬영장치의 한계 검사 개선 및 유용성 평가 (The Solution to the Limitation of the Conventional Digital X-ray System and Its Feasibility Test)

  • 길종원;박정호;배석환;황혜정;김용권
    • 디지털융복합연구
    • /
    • 제12권12호
    • /
    • pp.371-379
    • /
    • 2014
  • 본 연구는 단순움직임형검출기 DR 시스템에서 발생되는 한계 검사 극복을 위해 2012년 10월 15일부터 2012년 11월 15일까지 총 31일간 대전광역시 소재 종합병원 및 대학병원에 일반촬영 업무를 담당하고 있는 방사선사 30명을 대상으로 연구를 수행하였다. 설문을 통하여 임상요구도를 조사하고 이를 바탕으로 보조테이블을 개념 설계하여 요구도에 부합하는 검사법 적용실험과 이를 통해 얻어진 영상의 유용성 평가를 단계적으로 시행하였다. 본 연구에서는 9가지 검사에 대한 검사법 적용실험을 수행하였으며, 실험 결과의 유용성을 평가한 결과 임상적으로 매우 유용함을 알 수 있었다. 연구 결과에서 제안한 한계 검사 극복을 위한 보조테이블을 임상 실무에 적용한다면, 기존 단순움직임형검출기 DR 시스템의 한계 검사를 극복하여 시스템의 임상 활용도를 극대화시킬 수 있다는 결과를 얻을 수 있었다.

하지동맥 전산화단층촬영 검사 시 생리식염수 희석을 통한 조영제 사용량 감소의 융복합 효용성 연구 (A Convergence Study on effectiveness of contrast agent reduction by normal saline solution dilution in the computed tomography of arteries of lower limb)

  • 김상현
    • 디지털융복합연구
    • /
    • 제13권9호
    • /
    • pp.431-437
    • /
    • 2015
  • 하지 동맥 전산화단층촬영(CT) 검사 시 생리식염수 희석을 통한 조영제 사용량 감소의 효용성을 알아보고자 하였다. 조영제 125 cc 주입한 48명과 같은 양을 조영제와 생리 식염수를 7:3으로 주입한 30명을 대상으로 하였다. 각각의 영상에서 복부대동맥, 넙다리동맥, 오금동맥, 뒤정강동맥의 감쇄계수(HU)의 평균값과 신호 대 잡음비(SNR)를 정량적으로 평가 하였고, 정성적 평가는 영상의학과 전문의 2명, 방사선사 4명이 5점 척도로 4가지 평가항목을 평가하였다. 정량적 평가에서 HU와 SNR 모두 희석 전 평균값이 높게 나왔으나 독립표본 T검정에서 유의확률이 모두 p>0.05이므로 희석 전, 후의 통계적으로 유의성이 없다. 정성적 평가는 평균점수가 원액이 4.86~4.77, 희석액이 4.83~4.67로 차이가 있었으나, 유의확률이 모두 p>0.05이므로 희석 전, 후의 통계적으로 유의성이 없다. CT 하지동맥 조영 검사 시 일정 비율 희석한 조영제를 사용하여 기존 영상의 질을 유지 할 수 있고, 조영제의 총량을 줄여 단위 분자 당 요오드 함량이 낮아지므로 조영제로 인한 부작용을 줄일 수 있을 것으로 사료된다.

진단용 방사선 관련 업무 종사자의 피폭관리에 관한 연구 (A Study on the Management of Exposure of Workers and Assistants Related to Diagnostic Radiation)

  • 임창선
    • 의료법학
    • /
    • 제22권3호
    • /
    • pp.97-124
    • /
    • 2021
  • 의료기관에는 진단용 방사선 발생장치를 취급하는 방사선사, 의사, 치과의사, 치과위생사 등 방사선 관계 종사자가 있다. 그리고 간호사, 간호조무사 등 방사선진료를 보조하거나 방사선 검사실로 환자이송 등을 하는 업무 보조자들이 있다. 방사선 관계 종사자는「의료법」 등에 의해 방사선 피폭관리가 이루어지고 있으나 방사선 진료업무 보조자 등은 이에 대한 법적 근거가 없는 실정이다. 또한 진단용 방사선 피폭관리는 의료법령에 의해 규율되고 있고, 치료용 방사선과 핵의학검사에 의한 방사선 피폭관리는「원자력안전법」의 규율을 받고 있다. 이에 진단용 방사선에 의한 피폭관리를 개선하기 위하여「의료법」 상 진단용 방사선 피폭관리에 관한 규정과「원자력안전법」 상 관련 규정들을 비교·검토하여 보았다. 그 결과로 얻은 주요 내용은 다음과 같다. 첫째, 진단용 방사선에 의한 피폭관리 대상으로 방사선 관계 종사자 외에 방사선 피폭 우려가 있는 간호사, 간호조무사, 임상실습 학생 등을 포함시켜 입법적으로 해결할 필요가 있다. 둘째,「원자력안전법」에서처럼 진단용 방사선 관계 종사자가 임신이 확인된 경우에는 피폭선량 한도를 명문으로 규정해야 한다. 셋째,「진단용 방사선 발생장치의 안전관리에 관한 규칙」의 개인피폭선량계의 종류에 관한 규정을 현실에 맞게 개정할 필요가 있다. 넷째, 방사선 관계 종사자, 방사선작업종사자와 수시출입자에 대한 건강진단의 검사항목은 동일해야 할 것으로 보인다. 다섯째, 의료기관에서 진단용 방사선뿐만 아니라 치료용 방사선과 핵의학을 포함한 의료용 방사선 전체를 하나의 법체계에서 통일하여 규율하는 것이 필요하다고 본다.

방사선사(放射線士) 교육(敎育)의 임상실습(臨床實習) 개선(改善)에 관(關)한 연구(硏究) (A Study of the Improvement of Clinical and Practical Trainings in the Education of Radiologic Technologists)

  • 이만구;강세식;윤한식;허준
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제6권1호
    • /
    • pp.117-129
    • /
    • 1983
  • This study, in order to improve clinical and practical trainings in the education of radiologic technologists, applies to 76 medical institutions of 91 ones which are used as the hospitals of clinical and practical training in 9 existing junior colleges except 3 new ones of 12 ones throughout all over the country from November 1, in 1982 to April 30, in 1983. And the purpose of this study is to research the percent conditions of basic practical trainings and clinical ones enforced in each college, and the percent conditions, equipments, contents, and opinions in clinical and practical trainings enforced in each hospital. The results are summarized as follows; 1. In the case of junior colleges in the whole country the curriculum of basic practical trainings averages 336.66 hours and the limits are between 120 and 510 hours. The actual hours in practice average 140 hours and the limits are between 60 and 240 hours, which correspond to 41.58% of the curriculum of basic practical trainings. 2. There were three junior colleges among nine that had a reserved hospital for clinical and practical trainings(only 33.33%). 3. The period of the practice was almost vacation in 4 junior colleges. The practice was conducted only for students to want the practice(44.45%), junior colleges that all students in them conducted the practice was 2 junior colleges and presented 22.22%. 4. In the field of students engaging in the practice, each field of radiation therapy and nuclear medicine presented 16.5%, 20.3% and almost students didin't have experience for the practice. 5. In medical institutions the educational institutions for intern showed 67.11%. Hospital with radiologist showed 26.32%. Radiotechnologist who had experience below 5 years presented 60.17%. 6. In the equipment for radiation diagnosis, each hospital had no difference. The number of hospitals passessing diagnostic equipments above 125 KVP was 56.26%. But radiation therapy equipment and nuclear medicine equipment had extremely low rate. 7. In the diagnosis of patient in the practice hospital, conventional radiography-to Skull, Chest, Abdomen, Skeleton, Urogenital system-reached the criterion. But special radiography was comparatively low. There appeared low rate, 32.89% in the field of nuclear medicine, 15.79% in the field of radiation therapy. 8. Students who carried out the practice were 1-89 students, days in practice were 1-30 days. There were differences in that point among among hospitals. Junior colleges conducting the practice were 2 colleges per hospital. Scope of the object were 1-8 junior colleges. 9. The practice conducted for the request of the colleges presented 72.37%, in addition, The prctices were conducted for growth of the younger generation and the same coperation with the colleges establishment of sisterhood with the colleges, relationship with students. 10. The practice conducted without the establishment of plan presented 59.21% The need for guiding book to the practice and evaluating was recognized over 90%. 11. In the relation between the practice with achievement of credit. There were big differences in opinion between hospitals-Group and the colleges-Group; hospital-Group had opinion that must follow achievement of credit with the practice. The colleges-Group had opinion that must conduct the practice after achieving credit. 12. After conducting the practice, in the practice leaders satisfaction degree dissatisfactory opinion presented the most rate 80.26%. Very much satisfactory opinion, as one hospital, presentd only 1.32%. 13. Both hospitals-Group and the colleges-Group had an opinion that the practice leader must have actual experiences, lectures and achievement, an opinion that actual experiences is over 5 years. 14. In the guide of human relation, cooperation, responsibility, courtesy to patients. Both hospitals-Group and the colleges-Group had an opinion that the guide must be involved in the period of the practice and must be instructed.

  • PDF

소장 질환별 방사선학적 검사의 적용에 관한 연구 - 소장조영술과 복부골반전산화단층촬영의 결과 분석을 중심으로 - (Application of Radiological Study by Small Bowel Disease - Comparison of Diagnostic Results of Small Bowel Series and Abdominal Pelvic Computed Tomography -)

  • 이희정;손순룡;이원홍
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제28권4호
    • /
    • pp.279-286
    • /
    • 2005
  • 목 적 : 소장조영술과 복부골반 CT검사의 진단 결과를 비교함으로써 방사선학적 영상의 특징 파악 및 질환에 따른 적절한 방사선학적 검사법을 선택하는데 기초자료를 제공하고자 한다. 대상 및 방법 : 1999년부터 2000년까지 소장조영술과 복부골반 CT검사를 병행하여 시행한 환자 284명을 대상으로 하여, 각각의 진단 소견을 병명별로 분류하였다. 소장조영술은 250 ml 황산바륨 현탁액(W/V 40W/V%, Methylcellulose+$BaSo_4$)을 경구로 복용시키고, Rt. recumbent position을 취하게 한 후 약 10분 후에 Carboxymethylcellulose solution(0.5%) 600 ml 복용시켰다. 20분, 40분, 1시간 정규촬영을 하고, 조영제가 회맹판(I-C valve)을 통과하면 투시 하에 저격촬영을 시행하였다. 복부골반전산화단층촬영은 검사 1시간 전에 $BaSO_4$+Methylcellulose 1.5 W/V% 450 ml를 복용시키고 검사직전 450 ml 추가로 복용시켰다. 요오드 성분의 비이온성 조영제 2.5 ml flow/sec로 주입하고, 조영제 주입 후 72초 지연 촬영을 하였다. 촬영은 간 상연에서부터 치골결합 부위까지 continuous scan을 시행하였으며, 검사 protocol은 Helical thick 5 mm, picth 1.375 : 1, speed 27.50, increment 5 mm, 120 kV, 245 mA로 하였다. 결 과 : 소장조영술에서는 정상(Normal)이 131예(46.1%), 감염성 장질환(Inflammatory bowel disease ; 이하 IBS)이 65예(22.9%), ischemia+ileocolitis+vasculitis 22예(7.7%), obstruction+stricture 21예(7.4%)의 순으로 나타났고, 복부골반 CT검사에서는 정상이 103예(36.3%) IBS가 65예(22.9%), wall thickening+lymphadenopathy가 42예(14.8%), fluid collection이 17예(6%)의 순으로 나타났다. 소장조영술과 복부골반 CT검사에서 동일하지 않은 결과로 진단된 경우는 소장조영술에서 정상으로 진단된 132명(46.1%) 중 14예(10.6%), 복부골반 CT검사 결과에서는 wall thickening+lymphadenopathy와 IBS로 진단되어 차이를 보였으며, 복부골반 CT검사 결과 정상으로 진단된 103예(36.3%) 중 5예(5.8%)가 소장조영술에서 ischemia+ileocolitis+vasculitis로 진단되었다. 정상으로 진단 된 235예 중 37예(15.9%)가 서로 다른 결과로 진단되어 통계적으로 유의한 차이를 보였다(P<0.05). 결 론 : 본 연구에서 특정질환에 특정검사의 진단결과가 우수하게 나타나는 것으로 조사되었으므로 방사선학적 검사의 진단적 민감도를 높이기 위해서는 처방 및 검사에 있어서 질환에 따른 적절한 검사법의 선택이 무엇보다도 중요하리라 사료된다.

  • PDF

소아 흉부촬영 시 나이와 체격에 따른 입사피부선량 (Entrance Skin Dose According to Age and Body Size for Pediatric Chest Radiography)

  • 신귀순;민기열;김두한;이광재;박지환;이귀원
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제33권4호
    • /
    • pp.327-334
    • /
    • 2010
  • 전리방사선의 피폭에 의한 암 유발확률은 소아가 성인에 비해 크기 때문에 소아 X선 검사 시의 환자선량을 정확히 파악하는 일은 중요하다. 그러나 우리나라는 소아 환자선량에 대한 연구가 활발하지 않다. 그러므로 본 연구에서는 7세 미만 소아를 대상으로 전리함을 이용하여 흉부검사 시의 입사피부선량(entrance skin dose, ESD)을 측정하여 나이, 키, 체중, 가슴두께와 ESD의 관계를 비교한 결과는 다음과 같았다. 소아는 나이에 따라서 키, 체중 및 가슴두께가 비슷한 양상으로 증가하므로, 흉부촬영 시 측정하기 힘든 가슴두께 대신에 나이에 따라서 촬영조건을 설정해도 무방함을 알 수 있었다. 2세 미만 소아의 흉부 A-P 검사 시, kVp는 A병원에서 더 높았으나, mAs는 반대로 B병원에서 높아, ESD 값이 B병원에서 약 1.7배 높았다. 그러나 4세 이상 소아의 흉부 P-A 검사 시에는 mAs는 같았고 kVp는 B 병원에서 7 kVp 높았으나, ESD값은 FID가 먼 B병원(180 cm)에서보다 더 가까운 A병원(130 cm)에서 1.4배 정도 높았다. 또한 같은 나이라도 A-P가 P-A보다 ESD값이 높았다. 나이별에 따른 ESD값을 보면, 1세 미만은 $154{\mu}Gy$, 1세에서 4세 미만은 $194{\mu}Gy$, 4세에서 7세 미만은 $138{\mu}Gy$으로 나타났다. 이 값은 일본의 JART의 권고량($200{\mu}Gy$)보다 낮으나, EC(유럽위원회)나 영국의 NRPB의 권고량보다 높으며, 2009년 12월에 식품의약품안전평가원에 제출된 용역보고서의 진단참고준위(5세 소아에서의 중간값이 $100{\mu}Gy$)보다 높다. 결론적으로 ESD는 X선장치 시스템의 차이보다는 방사선사의 경험적 실행에 의한 촬영조건의 차이에 의해서 크게 달라짐을 알 수 있었으며, 또한 나이가 많다고 더 많은 선량을 받는 것은 아니다. 따라서 나이에 따른 소아의 적정 참고준위의 확립과 점진적인 환자선량의 저감화가 반드시 필요하다.

흉부촬영(胸部撮影)에서 증감지(增感紙)-필름계의 선질변화(線質變化)에 따른 감도(感度)와 화질에 관(關)한 연구(硏究) (Image and Exposure Dose in Accordance with Radiation Quality on Plain Chest Radiography)

  • 김정민;김동현;임태랑;석전유치;전전미향;앵정달야
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제15권1호
    • /
    • pp.65-78
    • /
    • 1992
  • Routine chest radiography is generally imaged by high voltage technique but some radiological technologists use low voltage for imaging. High voltage is usually said between $120\;kV{\sim}140\;kV$. Some RTs like using heavy filtration but others seldom like using it. However which is better for use calcium tungustate film screen system or ortho system and high contrast film or wide latitude c-type film for the exculusive use of chest radiography. We could not make a decision which is ideal method for use. In my opinion any method is not always exellent for chest radiography. In my experiments that I had at Kaken hospital in Japan last year I expect to keep the balance between image quality and diagnostic range and to reduce radiation dose for patients. My experiments are as follows. 1. We have looked into system characteristics(speed and contrast) in accordance with kVp($80{\sim}140$) and added filter($no{\sim}1/16\;VL$) in three screen film systems(BX3+CRONEX4, SRO750+MGH, SRO750+MGL). 2. We have looked into skin dose and film dose with same D=1.8 lung field density in accordance with kVp($80{\sim}140$) and added filter($no{\sim}1/16\;VL$) in three screen film systems. 3. We have compared with the evaluation between correlation of physical image quality(MTF) and optical diagnostic capability. Result are follows. 1. Speed of BX3+CRONEX4 became higher in accodance with kVp and thickness of filter but speed of ortho system was not as like regular system. Thicker filter diminished the speed over 100 kV range in SRO750+MGL. In case of SRO750+MGH speed of 1/16VL filter was looked into lower than speed of 1/4VL filter. Sensitivity of ortho system depends on tube voltage and added filter. 2. Skin dose has been detected $225\;{\mu}Gy{\sim}66\;{\mu}Gy$ in BX3+CRONEX4 from 80 kV, no filter to 140 kV, 1/16VL filter. SRO750+MGH could reduce the patient dose $1/2{\sim}1/3$ level in comparison to that of BX3+CRONEX4. 3. The higher kV was the worse MTF became the thicker filter was the worse MTF became too. MTF of BX3+CRONEX4 was detected better than MTF of SRO750+MGH but SRO750+MGH's optical detectability of small lesion in lung field came out better than that of BX3+CRONEX4. Conclusion Recently routine chest radiography is generally imaged by high voltage but it seems to be there are some questions in using of film screen combination. In high voltage chest radiography the subject contrast will come down that means latitude become wider. In this case if we select the low contrast film screen system(C or L type) the film contrast will fall down extremly and detectability of small lesion will be deteriorated. Wide latitude C, L type film has a merit of high detectability on mediastinum. Furthermore high contrast film screen system has the advantage to keep the high contrast in low density region as like mediastinum and heart shadow. Therefore in low subject contrast high voltage chest radiography we would rather choose the high contrast film screen system(H type) I think. From a view point of patient dose detectability of mediastinum and lung field. The optimum technical facter was found out 120 kV, 1/16VL filter : BX3+CRONEX4, 140 kV, 1/4VL filter : SRO750+MGH, 100 kV, 1/4VL filter : SRO750+MGL.

  • PDF

X-ray 갈비뼈 촬영에서 겨드랑이쪽의 골절된 갈비뼈 진단을 위한 촬영법 연구 (A Study Radiograph Techniques for Diagnosis of Axillary Fracture Ribs in X-ray)

  • 안병주;이준행
    • 한국방사선학회논문지
    • /
    • 제13권7호
    • /
    • pp.979-986
    • /
    • 2019
  • 본 연구는 Rib Rando Phantom을 이용하여 겨드랑 첫 번째, 두 번째 갈비뼈 골절이 선예하게 나타나는 영상의 검사방법을 연구하였다. 팬톰의 자세와 엑스선관 각도를 수직, 머리쪽 5°, 다리쪽 5°로 변경하여 검사하였다. 획득한 영상을 방사선사가 주관적으로 영상평가 하였으며, 평가 데이터를 SPSS ver. 3.0으로 분석하였다. ImageJ Program을 이용하여 신호대잡음비(SNR)를 계산하였다. 그 결과 Cronbach Alpha 값이 0.789로 유의하게 높았다. 신호대잡음비(SNR)의 결과는 갈비뼈 앞쪽의 경우 엑스선관을 머리쪽으로 5° 기울여 검사 시 6.038, 갈비뼈 뒤쪽의 경우 엑스선관을 다리쪽으로 5° 기울여 검사 시 7.860으로 가장 높았다. 겨드랑 갈비뼈의 촬영기법으로 앞쪽 검사는 골절된 부위를 거상하고 엑스선관 각도를 머리쪽으로 5° 주며, 뒤쪽 검사는 골절된 부위를 밀착하여 엑스선관 각도를 발쪽으로 5° 기울여 검사한다면 선예한 영상을 얻을 수 있을 것으로 사료된다.