• Title/Summary/Keyword: Radiological image

Search Result 1,260, Processing Time 0.024 seconds

The Evaluation of CR and DDR chest image using ROC analysis (ROC평가 방법을 이용한 CR과 DDR 흉부 영상의 비교)

  • Park, Yeon-Ok;Jung, Eun-Kyung;Park, Yeon-Jung;Nam, So-Ra;Jung, Ji-Young;Kim, Hee-Joung
    • Journal of the Korean Society of Radiology
    • /
    • v.1 no.1
    • /
    • pp.25-30
    • /
    • 2007
  • ROC(Receiver Operating Characteristic)curve is the method that estimate detected insignificant signal from the human's sense of sight, it has been raised excellent results. In this study, we evaluate image quality and equipment character by obtaining a chest image from CR(Computed Radiography) and DDR(Direct Digital radiography) using the human chest phantom, The parameter of exposure for obtaining chest image was 120 kVp/3.2 mAs and the SID(Source to Image Distance) was 180cm. The images were obtained by CR(AGFA MD 4.0 General plate, JAPAN) and DDR(HOLOGIC nDirect Ray, USA). Using some pieces of Aluminum and stone for expressing regions, then attached them on the heart, lung and thoracic vertebrae of the phantom. 29 persons hold radiology degrees were participated in ROC analysis. As a result of the ROC analysis, TPF(true positive fraction) and FPF(false positive fraction) of DDR and CR are 0.552 and 0.474 and 0.629 and 0.405, respectively. By using the results, the ROC curve of CR has higher image quality than DDR. According to the theory, DDR has the higher image quality than CR in chest X-ray image. But, CR has the higher image quality than DDR. quality of DDR inserted the enhance board. The results confirmed that image post-processing is important element decipherment of clinical.

  • PDF

The Performance of Heavy Ion CT System with Fluorescent Screen and CCD Camera

  • Tomida, Tetsuya;Nishimura, Katsuyuki;Abe, Shinji;Sato, Hitoshi;Muraishi, Hiroshi;Inada, Tetsuo;Tazawa, Shuichi;Kanai, Tatsuaki;Yusa, Ken;Kawachi, Kiyomitsu
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.432-435
    • /
    • 2002
  • We have developed and proposed the heavy ion CT system which consists of fluorescent screen and CCD camera equipped with image intensifier. In our system, we have measured the residual range of particles that passed a phantom and reconstructed the CT image for the distribution of relative stopping power by filtered back projection method with Shepp '||'&'||' Logan filter. The heavy ion $\^$12/C accelerated up to 400 MeV/u by HIMAC (Heavy Ion Medical Accelerator in Chiba) was used. Intensity of the beam output changes like macro pulse, the period being 3.3 sec and the width being 2 sec. The series of data was acquired in synchronizing with the pulse, leading to the improvement of S/N in the CT image. The fundamental performance was experimentally evaluated in the proposed system. The spatial resolution was estimated to be about 1 mm and the density resolution (electron density referred to water) to be about 0.01.

  • PDF

The Noise Power Spectrum in Heavy Ion CT Based on Measurement of Residual Range Distribution

  • Yasuda, Naruomi;Abe, Shinji;Nishimura, Katsuyuki;Tomita, Tetsuya;Sato, Hitoshi;Muraishi, Hiroshi;Kanzaki, Takayuki;Inada, Tetsuo;Fujisaki, Tatsuya
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.228-230
    • /
    • 2002
  • The relative electron density resolution was discussed by the noise power spectrum (NPS) in the heavy ion CT image. The heavy ion beam $\^$12/C accelerated up to 400MeV/u by RIMAC was used in this study. The two-dimensional (2-D) NPS in the CT image was obtained from the one-dimensional (1-D) NPS of the measured residual range distribution of water phantom for single projection, and the noise variance in the CT image was calculated from 2-D NPS. The technique used in the reconstruction was the filtered back-projection method with Shepp-Logan filter. The calculated value suggests the result of our previous works using the density resolution phantom, assuming that the relative electron density resolution is twice the standard deviation. Therefore, the estimation of the noise in CT images by 2-D NPS obtained the measured residual range distribution is the useful method.

  • PDF

A Study on the Fabrication and Comparison of the Phantom for Computed Tomography Image Quality Measurements Using Three-Dimensions Printing Technology (삼차원 프린팅 기술을 이용한 전산화단층영상 품질 측정용 팬텀 제작 및 비교 연구)

  • Yoon, Myeong-Seong;Hong, Soon-Min;Heo, Yeong-Cheol;Han, Dong-Kyoon
    • Journal of radiological science and technology
    • /
    • v.41 no.6
    • /
    • pp.595-602
    • /
    • 2018
  • Quality control (QC) of Computed Tomography (CT) devices is based on image quality measurement on AAPM CT phantom which is a standard phantom. Although it is possible to control the accuracy of the CT apparatus, it is expensive and has a disadvantage of low penetration rate. Therefore, in this study, we make image quality measurement phantom at low cost using FFF (Fused Filament Fabrication) type three-dimensional printer and try to analyze the usefulness, compare it with existing standard phantom. To print a phantom, We used three-dimensional printer of the FFF system and PLA (Poly Lactic Acid, density: $1.24g/cm^3$) filament, and the CT device of 64 MDCT (Aquilion CX, Toshiba, Japan). In addition, we printed a phantom using three-dimensional printer after design using various tool based on existing standard phantom. For image quality evaluation, AAPM CT phantom and self-generated phantom were measured 10 times for each block. The measured data were analyzed for significance using the Mannwhiteney U-test of SPSS (Version 22.0, SPSS, Chicago, IL, USA). As a result of the analysis, phantom fabricated with three-dimensional printer and standard phantom showed no significant difference (p>0.05). Furthermore, we confirmed that image quality measurement performance of a phantom using three-dimensional printer is similar to the existing standard phantom. In conclusion, we confirmed the possibility of low cost phantom fabrication using three dimensional printer.

Evaluation of the Resolution Characteristics by Using ATS 535H Phantom for Ultrasound Medical Imaging (초음파 의료영상에서 ATS 535H 팬텀을 이용한 해상력 특성 평가)

  • Jung-Whan, Min;Hoi-Woun, Jeong;Hea-Kyung, Kang
    • Journal of radiological science and technology
    • /
    • v.46 no.1
    • /
    • pp.15-21
    • /
    • 2023
  • This study was purpose to assessment of the resolution characteristics by using ATS 535H Basic quality assurance (QA) phantom for ultrasound. The ultrasound equipment was used Logiq P6 (Ultrasound, GE Healthcare System, Chicago, IL, USA). And the ultrasound transducer were used Convex 4C (4~5.5 MHz), Linear 11L (10~13 MHz), Sector 3SP (3~5.5 MHz) probe. As for the noise power spectrum (NPS) comparison results by using ATS 535H Basic QA ultrasound phantom and Convex 4C, Linear 11L, Sector 3SP probe. The NPS value of the Convex 4C probe image was 0.0049, Linear 11L probe image was 0.0049, Sector 3SP probe image was 0.1422 when the frequency is 1.0 mm-1. The modulation transfer function (MTF) comparison results by using ATS 535H Basic QA ultrasound phantom and Linear 11L probe the MTF value of the 3 cm focus image was 0.7511 and 4 cm focus image was 0.9001 when the frequency is 1.0 mm-1. This study was presented characteristics of spatial resolution a quantitative evaluation methods by using ultrasound medical images for QA of ultrasound medical QA phantom. The quality control (QC) for equipment maintenance can be efficiently used in the clinic due to the quantitative evaluation of the NPS and MTF as the standard methods. It is meaningful in that it is applied mutatis mutandis and presented the results of physical resolution characteristics of the ultrasound medical image.

Management of oral and maxillofacial radiological images (Dr. Image를 이용한 구강악안면방사선과 의료영상 관리)

  • Kim Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • v.32 no.3
    • /
    • pp.129-134
    • /
    • 2002
  • Purpose : To implement the database system of oral and maxillofacial radiological images using a commercial medical image management software with personally developed classification code. Materials and methods : The image database was built using a slightly modified commercial medical image management software, Dr. Image v.2.1 (Bit Computer Co., Korea). The function of wild card '*' was added to the search function of this program. Diagnosis classification codes were written as the number at the first three digits, and radiographic technique classification codes as the alphabet right after the diagnosis code. 449 radiological films of 218 cases from January, 2000 to December, 2000, which had been specially stored for the demonstration and education at Dept. of OMF Radiology of Dankook University Dental Hospital, were scanned with each patient information. Results: Cases could be efficiently accessed and analyzed by using the classification code. Search and statistics results were easily obtained according to sex, age, disease diagnosis and radiographic technique. Conclusion : Efficient image management was possible with this image database system. Application of this system to other departments or personal image management can be made possible by utilizing the appropriate classification code system.

  • PDF

Reduction of Patient Dose Exposure and Improvement of Image Quality by Use of Additional Filtration in Digital Radiology (디지털 진단방사선촬영에서 부가여과판 사용에 따른 피폭선량 감소와 화질 개선)

  • Moon, Su-Jeong;Kim, Young-Keun;Lee, Seong-Kil
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.1
    • /
    • pp.19-25
    • /
    • 2010
  • This study is mainly for the reduction of exposure dose by using a heavy elements filter(Gd) in the digital radiology. They contained heavy elements filter of Gd and X-ray beam hardening filters such as Al and Cu. According to the results of experimental evaluation, X-ray property was not changed with variety of kVp in the case of the Gd filter. The surface dose and absorption dose were increased in order of Cu and Al. The contrast of image showed the higher value in order of Cu, Al and Gd. While the use of Gd has increased the numerical value of the CR image, and grayscale has decreased noise value of the DR image.

  • PDF

The Model of Illumination-Transillumination for Image Enhancement of Xray Images (조명-투과 영상모델을 이용한 방사선 영상 개선에 관한 연구)

  • Lyu, Kwang-Yeul;Rhee, Sang-Min
    • Journal of radiological science and technology
    • /
    • v.24 no.1
    • /
    • pp.67-73
    • /
    • 2001
  • In digital image processing, the homomorphic filtering approach is derived from an illumination-reflectance model of the image. It can also be used with an illumination-transillumnation model of X-ray film. Several X-ray images were applied to enhancement with histogram equalization and homomorphic filter based on an illumination-transillumination model. The homomorphic filter has proven theoretical claim of image density range compression and balanced contrast enhancement, and also was found a valuable tool to process analog X-ray images to digital images.

  • PDF

Prediction of Bone Aging by Adapting Image J (Image J를 활용한 뼈의 노화도 예측법)

  • Jung, Hong Moon;Won, Do Yeon;Jung, Jae Eun
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.63-67
    • /
    • 2012
  • Calcium density in human bones decreases as people are getting older due to the interior or exterior environmental factors. Bone aging forms osteoporosis. And this can bring out various spine fractures which develops a complications. Thus the prediction of seniliy is one of the important factors in spine diseases. Once spine aged, diverse fractures occur such as compression fracture and micro fracture. Side images of the spine by the digital radiography (DR) were prepared, and pixel arbitrary unit with Image J was measured from one spot in the lumbar bone part. By calculating pixel arbitrary unit of the simple contrast, it was obtained that the value of pixel arbitrary unit decreased as seniliy of bones increased. By simply applying Image J to the seniliy of patient's spine, the seniliy of bones predicts the level of danger with only digital radiography(2D) image. consequently we show that Image J value of pixel arbitrary unit index for predicts the level of precaution of osteoporosis patient.

  • PDF

Influencing Factors of Radiological Technologist Image of Allied Health College Students (보건계열 대학생들의 방사선사 이미지에 영향을 미치는 요인)

  • Eom, Jong-Kwon;Shin, Seong-Gyu
    • Journal of radiological science and technology
    • /
    • v.35 no.1
    • /
    • pp.25-33
    • /
    • 2012
  • Perception level and social position of radiological technologist influence satisfaction level of their job. This study aims to use foundational data to improve perception level and social position of radiological technologists. We conducted interviews and a fill-out survey with 233 students who have been majoring in health-related fields at five universities and colleges located in Busan and who finished internship programs. The study analyzed 233 answer sheets excluding 17 inadequate answer sheets using T-test, ANOVA and multiple regression analysis with SAS9.1. The mean score of perception level was $3.33{\pm}0.56$. The personal image of radiological technologist showed the best score($3.43{\pm}0.56$) whereas the social image showed the worst($3.12{\pm}0.58$). According to the classification of the subject, the answer, "radiological technologist is specialized job", showed the best score($3.99{\pm}0.79$). The answer "radiological technologist suffered from less stress and workload than others when they work usually" showed the worst score($2.88{\pm}0.98$). According to the classification of each health-related major, the mean score of students who are a major in the department of the radiological technologist was the best($3.46{\pm}0.46$) and the students who are major in department of the physical therapy was the worst($3.24{\pm}0.40$). The radiological technologist have to effort to make positive image in the hospital. It is possible to be developed their knowledge and professionalism by cooperating between school and hospital as well as advertising with mass madia.