• Title/Summary/Keyword: Radiological hazard

Search Result 62, Processing Time 0.028 seconds

Growth Retardation and Death of Rice Plants Irradiated with Carbon Ion Beams Is Preceded by Very Early Dose- and Time-dependent Gene Expression Changes

  • Rakwal, Randeep;Kimura, Shinzo;Shibato, Junko;Nojima, Kumie;Kim, Yeon-Ki;Nahm, Baek Hie;Jwa, Nam-Soo;Endo, Satoru;Tanaka, Kenichi;Iwahashi, Hitoshi
    • Molecules and Cells
    • /
    • v.25 no.2
    • /
    • pp.272-278
    • /
    • 2008
  • The carbon-ion beam (CIB) generated by the heavy-ion medical accelerator in Chiba (HIMAC) was targeted to 7-day-old rice. Physiological parameters such as growth, and gene expression profiles were examined immediately after CIB irradiation. Dose-dependent growth suppression was seen three days post-irradiation (PI), and all the irradiated plants died by 15 days PI. Microarray (Agilent rice 22K) analysis of the plants immediately after irradiation (iai) revealed effects on gene expression at 270 Gy; 353 genes were up-regulated and 87 down-regulated. Exactly the same set of genes was affected at 90 Gy. Among the highly induced genes were genes involved in information storage and processing, cellular processes and signaling, and metabolism. RT-PCR analysis confirmed the microarray data.

Reconstruction plates used in the surgery for mandibular discontinuity defect

  • Seol, Guk-Jin;Jeon, Eun-Gyu;Lee, Jong-Sung;Choi, So-Young;Kim, Jin-Wook;Kwon, Tae-Geon;Paeng, Jun-Young
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.40 no.6
    • /
    • pp.266-271
    • /
    • 2014
  • Objectives: The purpose of this study was to analyze the survival rate of reconstruction plates that were used to correct mandibular discontinuity defects. Materials and Methods: We analyzed clinical and radiological data of 36 patients. Only discontinuous mandibular defect cases were included in the study. Reconstruction plate survival rate was analyzed according to age, gender, location of defect, defect size, and whether the patient underwent a bone graft procedure, coronoidectomy, and/or postoperative radiation therapy (RT). Results: Plate-related complications developed in 8 patients, 7 of which underwent plate removal. No significant differences were found in plate survival rate according to age, gender, location of defect, defect size, or whether a bone graft procedure was performed. However, there were differences in the plate survival rate that depended on whether the patient underwent coronoidectomy or postoperative RT. In the early stages ($9.25{\pm}5.10months$), plate fracture was the most common complication, but in the later stages ($35.75{\pm}17.00months$), screw loosening was the most common complication. Conclusion: It is important to establish the time-related risk of complications such as plate fracture or screw loosening. Coronoidectomy should be considered in most cases to prevent complications. Postoperative RT can affect the survival rate and hazard rate after a reconstruction plate is fitted.

Natural radioactivity level in fly ash samples and radiological hazard at the landfill area of the coal-fired power plant complex, Vietnam

  • Loan, Truong Thi Hong;Ba, Vu Ngoc;Thien, Bui Ngoc
    • Nuclear Engineering and Technology
    • /
    • v.54 no.4
    • /
    • pp.1431-1438
    • /
    • 2022
  • In this study, natural radioactivity concentrations and dosimetric values of fly ash samples were evaluated for the landfill area of the coal-fired power plant (CFPP) complex at Binh Thuan, Vietnam. The average activity concentrations of 238U, 226Ra, 232Th and 40K were 93, 77, 92 and 938 Bq kg-1, respectively. The average results for radon dose, indoor external, internal, and total effective dose equivalent (TEDE) were 5.27, 1.22, 0.16, and 6.65 mSv y-1, respectively. The average emanation fraction for fly ash were 0.028. The excess lifetime cancer risks (ELCR) were recorded as 20.30×10-3, 4.26×10-3, 0.62×10-3, and 25.61×10-3 for radon, indoor, outdoor exposures, and total ELCR, respectively. The results indicated that the cover of shielding materials above the landfill area significantly decreased the gamma radiation from the ash and slag in the ascending order: Zeolite < PVC < Soil < Concrete. Total dose of all radionuclides in the landfill site reached its peak at 19.8 years. The obtained data are useful for evaluation of radiation safety when fly ash is used for building material as well as the radiation risk and the overload of the landfill area from operation of these plants for population and workers.

The presence of carcinogenic radon in the Padma River water, adjacent to the Rooppur Nuclear Power Plant

  • M.M. Mahfuz Siraz;M.S. Alam;Jubair A.M.;S.C. Das;J. Ferdous;Z. Hossain;S. Das;Mayeen Uddin Khandaker;D.A. Bradley;Shinji Tokonami;S. Yeasmin
    • Nuclear Engineering and Technology
    • /
    • v.55 no.8
    • /
    • pp.3046-3053
    • /
    • 2023
  • Radon is a naturally occurring carcinogenic agent, poses a serious health hazard when inhaled or ingested in significant amounts. The water of the Padma river will be used as a tertiary coolant for the soon-to-be-commissioned 'Rooppur Nuclear Power Plant'. Hence, it is important to assess the radiological status of the river prior to the commission of this power plant. Therefore, for the first time, 25 samples of water were collected from various locations of the Padma River and analyzed for radon concentration using the RAD H2O (DURRIDGE) radon monitoring device. The radon concentrations were found in the range from 0.077 ± 0.036 to 0.494 ± 0.211 Bq/L with a mean of 0.250 ± 0.093 Bq/L. All the concentrations were found to be below the recommended limits of WHO (100 Bq/L) and USEPA (11.1 Bq/L). The mean annual effective dose due to the radon exposure via inhalation and ingestion pathways were 0.638 µSv/y and 0.629 µSv/y, respectively, which were all well below the annual effective dose recommended by WHO (0.1 mSv/y). Since Bangladesh lacks a national safety limit of radon in water, this pioneering study provides baseline data on radon levels for the environment around Rooppur Nuclear Power Plant.

Assessment of radionuclides from coal-fired brick kilns on the outskirts of Dhaka city and the consequent hazards on human health and the environment

  • M.M. Mahfuz Siraz;M.D.A. Rakib;M.S. Alam;Jubair Al Mahmud;Md Bazlar Rashid;Mayeen Uddin Khandaker;Md. Shafiqul Islam;S. Yeasmin
    • Nuclear Engineering and Technology
    • /
    • v.55 no.8
    • /
    • pp.2802-2811
    • /
    • 2023
  • In a first-of-its-kind study, terrestrial radionuclide concentrations were measured in 35 topsoil samples from the outskirts of Dhaka using HPGe gamma-ray spectrometry to assess the radiological consequences of such a vast number of brick kilns on the plant workers, general as well as dwelling environment. The range of activity concentrations of 226Ra, 232Th, and 40K is found at 19 ± 3.04 to 38 ± 4.94, 39 ± 5.85 to 57 ± 7.41, and (430 ± 51.60 to 570 ± 68.40) Bq/kg, respectively. 232Th and 40K concentrations were higher than the global averages. Bottom ash deposition in lowlands, fly ash buildup in soils, and the fallout of micro-particles are all probable causes of the elevated radioactivity levels. 137Cs was found in the sample, which indicates the migration of 137Cs from nuclear accidents or nuclear fallout, or the contamination of feed coal. Although the effective dose received by the general public was below the recommended dose limit but, most estimates of hazard parameters surpass their respective population weighted global averages, indicating that brick kiln workers and nearby residents are not safe due to prolonged exposures to terrestrial radiation. In addition, the soil around sampling sites is found to be unsuitable for agricultural purposes.

Research on the Actual Condition of the radiation Safety Management(RSM) for the Educated Training of the Dental Diagnostics X-ray Generators (교육용 치과 엑스선 발생장치에 대한 방사선 안전 관리 실태 조사)

  • Lee, Mihyeon;Yu, Yunsik;Lee, Jaeseung;Im, Inchul
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.7
    • /
    • pp.467-477
    • /
    • 2014
  • The purpose of this study is to offer data base for establishment of dental training x-ray generator based safety usage through surveying real radiation safety management state of radiation worker's in plan of operations that have dental training x-ray generators and use it. For it, comprehensive references were surveyed referring reports of current state of regulation technique development and domestic radiation safety evaluation and nuclear related legislation regarding radiation safety management of dental training x-ray generators. On the basis of it, questionnaires were filled in about respondent's general characteristic radiation safety manager's status current state of radiation safety management and the level of knowledge & consciousness. For the study, the survey was conducted to 224 people of radiation safety managers and university graduates training assistants and full-time professors who can treat dental training x-ray generators in education center. through this survey 95 questionnaires were used as analysis materials except the insufficient and omitted responses. As a method of analysis, the frequency and percentage were figured out with the general characteristics and safety manager's status. Chi-square test for frequency and correlation per question analysis and Pearson correlation analysis for crosslevel correlation were done with current state of radiation safety management and knowledge & consciousness level. As a result, running dental training x-ray generators was dealt with by 20's to 40's who have high education level over post undergraduate degree and major in dental hygienic. In addition, female have higher consciousness level for radiation safety management than male. It shows significal linear relation statistically(${\chi}^2$ >5, 0.1${\chi}^2$ >5, 0.3${\chi}^2$ >5, 0.3

Preliminary Study for Development of Low Dose Radiation Shielding Material Using Liquid Silicon and Metalic Compound (액상 실리콘과 금속화합물을 융합한 저선량 방사선 차폐 소재 개발을 위한 사전연구)

  • Jang, Seo Goo;Han, Su Chul;Kang, Sung Jin;Lim, sung wook;Lee, Sung Soo
    • Journal of radiological science and technology
    • /
    • v.40 no.3
    • /
    • pp.461-468
    • /
    • 2017
  • This study measured and compared the protective clothing using Pb used for shielding in a diagnostic X-ray energy range, and the shielding rates of X-ray fusion shielding materials using Si and $TiO_2$. For the experiment, a pad type shielding with a thickness of 1 mm was prepared by mixing $Si-TiO_2$, and the X-ray shielding rate was compared with 0.5 mmPb plate of The shielding rate of shielding of 0.5 mmPb plate 95.92%, 85.26 % based on the case of no shielding under each 60 kVp, 100 kVp tube voltage condition. When the shielding of $Si-TiO_2$ pad was applied, the shielding rate equal to or greater than 0.5 mmPb plate was obtained at a thickness of 11 mm or more, and the shielding rate of 100% or more was confirmed at a thickness of 13 mm in 60 kVp condition. When the shielding of $Si-TiO_2$ pad was applied, the shielding rate equal to or greater than 0.5 mmPb plate was obtained at a thickness of 17 mm or more, and a shielding rate of 0.5 mmPb plate was observed at a thickness of 23 mm in 100 kVp condition. Through the results of this study, We could confirm the possibility of manufacturing radiation protective materials that does not contain lead hazard using various metalic compound and liquid Si. This study shows that possibility of liquid Si and other metalic compound can harmonize easily. Beside, It is flexible and strong to physical stress than Pb obtained radiation protective closthes. But additional studies are needed to increase the shielding rate and reduce the weight.

Problems of the Legal System Related to the Regulation of Radiation Safety for Diagnosis (진단용 방사선 안전관련 법령의 법체계상 문제점)

  • Lim, Chang-Seon;Moon, Heung-Ahn
    • The Korean Society of Law and Medicine
    • /
    • v.14 no.2
    • /
    • pp.119-142
    • /
    • 2013
  • It is not easy to regulate the amount of radiation used for the medical purpose as there usually is more good than harm to the patient's health and life caused by the medical exposure to the radiation. However, the rapid increase of the use of diagnostic radiation involves a high possibility of increasing the radiation hazard exposure. Therefore, it is imperative to implement effective regulations in order to secure the safety of diagnostic radiation. The one and only rule we currently have for the diagnostic radiation is "Medicine Act" with only one clause dedicated to regulate the safety management that does not include any rules for the medical radiation. A set of inclusive rules for the whole medical radiation inclusive of diagnostic radiation and therapeutic radiation need to be based on the "Medicine Act" rather than "Nuclear Safety Act" in order to protect the medical professionals, patients and the guardians of patients from the hazards of diagnostic and/or therapeutic radiation that was not used the purpose of medical treatment. If there is an administrative measure to be imposed to secure the safety of diagnostic radiation, it is considered as exertion of governmental authority of administrative agency. There must be clear and realistic legal guidelines for in-fringe on people's interests. The administrative measures for the safety management of the diagnostic radiation must be clearly and specifically based on the law and the detailed standards for the administrative measures must be dele-gated by the presidential decree or departmental ordinance. Accordingly, the restrictions imposed by the administrative measures to the "Safety Inspection Institute of Radiation along with Radiation Exposure Measuring Institutes" should have clear legal basis as well and the detailed standards for the administrative measures should be regulated by the Ministry of Health and Welfare decree instead of the notification by the Director of Korean Centers for Disease Control and Prevention. While securing the safety of radiation on one side, careful review and up-grade on our legal system for the safety management of the diagnostic radiation is required on the other side to guarantee the legality, interest balance and reliability of the administrative measures.

  • PDF

Whiplash Injury Conditions of Rear-End Collisions at Low-Speed (저속 추돌사고에서 목 상해 조건에 대한 연구)

  • Kim, Myeongju;Yun, Ilsoo
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.18 no.2
    • /
    • pp.58-76
    • /
    • 2019
  • As the number of reported injuries has tended to increase over time, large hospitalization expenditure from excessive medical treatments and hospitalization, and insurance frauds associated with moral hazard in minor collisions have caused a global societal problem. Many occupants of rear-ended vehicles involved in rear-end collisions complain of whiplash injury, which is also known as neck injury, without any anatomical and radiological evidence. With only clinical symptoms, stating that a whiplash injury is a type of injury defined by the Abbreviated Injury Scale would be difficult. Therefore, this study focuses on minor rear-end collisions, where the rear-ender vehicle collides with the rear-ended vehicle at rest. The mathematics dynamic model is employed to simulate a total of 100 rear-end collision scenarios based on various weights and collision speeds and identify how the weights and speeds of both vehicles influence the risk of whiplash injury in occupants involved in minor rear-end collisions. The possibility of an injury is very high when the same-weight vehicles are involved in accidents at collision speeds of 15 km/h or higher. The possibilities are 36% and 84% with collision speeds of 15 km/h and 20 km/h, respectively, if weights are disregarded.

An Analysis of Temperature Change and TI MI using Tissue Mimicking Phantom in Ultrasonic Examination (초음파검사에서 인체모의 매질팬텀을 이용한 온도 변화와 TI MI 분석)

  • Cheol-Min, Jeon;Jae-Bok, Han;Jong-Gil ,Kwak;Jong-Nam, Song
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.6
    • /
    • pp.751-759
    • /
    • 2022
  • Currently, ultrasound examination for diagnostic ultrasound and health examination purposes is widely used, and it is showing an increasing trend due to the application of health insurance. However, the risk of ultrasound has not been clearly identified so far, and in this study, surface and deep temperature changes according to frequency and mode were measured by using a tissue mimicking phantom and TI and MI values were compared. A simulated phantom was manufactured by adding a small amount of kappa-caraginan powder with acoustic characteristics similar to that of the human body and potassium chloride for solidification, and the change of surface and depth temperature was measured using a surface thermometer and a probe thermometer. As a result, the convex probe using low frequency showed a higher temperature increase than the linear probe using high frequency, so there was a significant difference, and the temperature increase was the highest on the surface, and the depth of 1cm showed a temporary temperature increase, but there was no significant temperature change. There was no change in the deep temperature of 5 cm to 15 cm, and the TI and MI values did not change during the test time. Since only the surface temperature rose during the 15-minute test and there was no temperature change in the core, so it is not expected to show a temperature change that is harmful to the human body. However, it is thought that prolonged examination of one area may cause temperature rise, so it should be avoided.