• 제목/요약/키워드: Radiological dose assessment

검색결과 185건 처리시간 0.027초

X-band EPR dosimetry using minimum mass of tooth enamel for use in radiological accidents

  • Jae Seok Kim;Byeong Ryong Park;Han Sung Kim;In Mo Eo;Jaeryong Yoo;Won Il Jang;Minsu Cho;HyoJin Kim;Yong Kyun Kim
    • Nuclear Engineering and Technology
    • /
    • 제56권1호
    • /
    • pp.123-131
    • /
    • 2024
  • Electron paramagnetic resonance (EPR) dosimetry for a tooth from an individual exposed is well known as retrospective dosimetry in radiological accidents. A major constraint of the conventional X-band tooth-EPR dosimetry is the necessity to extract the tooth of the exposed patient for dose assessment. In this study, to conduct the dose assessments of exposed patients through part-extraction of tooth enamel, the minimum detectable dose (MDD) of the tooth enamel was evaluated based on the amount of mass. Further, a field test was conducted via intercomparison using various dose assessment methods to verify the feasibility of X-band tooth-EPR dosimetry using the minimum mass of tooth enamel. The intercomparison results demonstrated that effective dose determination via X-band tooth-EPR dosimetry is reliable. Consequently, it was determined that the minimum mass of tooth enamel required to evaluate an absorbed dose above 0.5 Gy is 15 mg. Thus, EPR dosimetry using 15 mg of tooth enamel can be applied in the triage and initial medical response stages for patients exposed during radiological accidents. This approach represents an advancement in managing radiological accidents by offering a more efficient and less invasive method of dose assessment.

X선진단(診斷) 영역(領域)에 있어서의 심부선량분포(深部線量分布)의 측정(測定) (Measurement of Dose Distribution for Diagnostic X-ray)

  • 김유현;허준;김성철;윤종민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제18권1호
    • /
    • pp.55-62
    • /
    • 1995
  • This study was performed to find out dose distribution, pdd, surface dose and off center ratio. A few articles is analysis of dose data in radiotherapy field, there is no standardized measure of an assessment of exposure dose at diagnostic radiology, yet. And authors demonstrated a new assessment measure by ion chamber, TLD and film dosimetry system. We assurance that our data is useful to quantiative analysis of exposure dose and clinical fields for reduction of radiation dose.

  • PDF

Depth Dose According to Depth during Cone Beam Computed Tomography Acquisition and Dose Assessment in the Orbital Area Using a Three-Dimensional Printer

  • Min Ho Choi;Dong Yeon Lee;Yeong Rok Kang;Hyo Jin Kim
    • Journal of Radiation Protection and Research
    • /
    • 제49권2호
    • /
    • pp.68-77
    • /
    • 2024
  • Background: Cone beam computed tomography (CBCT) is essential for correcting and verifying patient position before radiation therapy. However, it poses additional radiation exposure during CBCT scans. Therefore, this study aimed to evaluate radiological safety for the human body through dose assessment for CBCT. Materials and Methods: For CBCT dose assessment, the depth dose was evaluated using a cheese phantom, and the dose in the orbital area was evaluated using a human body phantom self-fabricated with a three-dimensional printer. Results and Discussion: The evaluation of radiation doses revealed maximum doses of 14.14 mGy and minimum doses of 6.12 mGy for pelvic imaging conditions. For chest imaging conditions, the maximum doses were 4.82 mGy, and the minimum doses were 2.35 mGy. Head imaging conditions showed maximum doses of 1.46 mGy and minimum doses of 0.39 mGy. The eyeball doses using a human body phantom model averaged at 2.11 mGy on the left and 2.19 mGy on the right. The depth dose ranged between 0.39 mGy and 14.14 mGy, depending on the change in depth for each imaging mode, and the average dose in the orbit area using a human body phantom was 2.15 mGy. Conclusion: Based on the experimental results, CBCT did not significantly affect the radiation dose. However, it is important to maintain a minimal radiation dose to optimize radiation protection following the as low as reasonable achievable principle.

Radiological Dose Assessment Due to the Operation of Nuclear Facilities at KAERI Nuclear Site

  • Han, M.H.;Kim, E.H.;Hwang, W.T;Yeom, J.M.;Han, J.T.;Lee, Y.B.;Han, W.J.
    • Journal of Radiation Protection and Research
    • /
    • 제28권3호
    • /
    • pp.247-254
    • /
    • 2003
  • To prevent the potential health detriment to the public from radioactive effluents, radiological dose assessments due to the operation of nuclear facilities located at Korea Atomic Energy Research Institute (KAERI) site has been performed semiannually in compliance with the Minister of Science and Technology (MOST)'s Notice in Korea. Radiological dose assessment based on the new recommendation of the International Committee on Radiation Protection (ICRP-60) has been conducted since 1998. In this manuscript, a serial activities at KAERI site to meet the regulatory standards for routine releases of radioactive effluents are introduced and discussed including technical approaches. It is clear that each nuclear facility has been operated in compliance with regulatory standards. Furthermore, it is identified that the radiation induced health effects for residents around the site are neglectable.

Development of Internal Dose Assessment Procedure for Workers in Industries Using Raw Materials Containing Naturally Occurring Radioactive Materials

  • Choi, Cheol Kyu;Kim, Yong Geon;Ji, Seung Woo;Koo, Boncheol;Chang, Byung Uck;Kim, Kwang Pyo
    • Journal of Radiation Protection and Research
    • /
    • 제41권3호
    • /
    • pp.291-300
    • /
    • 2016
  • Background: It is necessary to assess radiation dose to workers due to inhalation of airborne particulates containing naturally occurring radioactive materials (NORM) to ensure radiological safety required by the Natural Radiation Safety Management Act. The objective of this study is to develop an internal dose assessment procedure for workers at industries using raw materials containing natural radionuclides. Materials and Methods: The dose assessment procedure was developed based on harmonization, accuracy, and proportionality. The procedure includes determination of dose assessment necessity, preliminary dose estimation, airborne particulate sampling and characterization, and detailed assessment of radiation dose. Results and Discussion: The developed dose assessment procedure is as follows. Radioactivity concentration criteria to determine dose assessment necessity are $10Bq{\cdot}g^{-1}$ for $^{40}K$ and $1Bq{\cdot}g^{-1}$ for the other natural radionuclides. The preliminary dose estimation is performed using annual limit on intake (ALI). The estimated doses are classified into 3 groups ( < 0.1 mSv, 0.1-0.3 mSv, and > 0.3 mSv). Air sampling methods are determined based on the dose estimates. Detailed dose assessment is performed using air sampling and particulate characterization. The final dose results are classified into 4 different levels ( < 0.1 mSv, 0.1-0.3 mSv, 0.3-1 mSv, and > 1 mSv). Proper radiation protection measures are suggested according to the dose level. The developed dose assessment procedure was applied for NORM industries in Korea, including coal combustion, phosphate processing, and monazite handing facilities. Conclusion: The developed procedure provides consistent dose assessment results and contributes to the establishment of optimization of radiological protection in NORM industries.

The System of Radiation Dose Assessment and Dose Conversion Coefficients in the ICRP and FGR

  • Kim, Sora;Min, Byung-Il;Park, Kihyun;Yang, Byung-Mo;Suh, Kyung-Suk
    • Journal of Radiation Protection and Research
    • /
    • 제41권4호
    • /
    • pp.424-435
    • /
    • 2016
  • Background: The International Commission on Radiological Protection (ICRP) recommendations and the Federal Guidance Report (FGR) published by the U.S. Environmental Protection Agency (EPA) have been widely applied worldwide in the fields of radiation protection and dose assessment. The dose conversion coefficients of the ICRP and FGR are widely used for assessing exposure doses. However, before the coefficients are used, the user must thoroughly understand the derivation process of the coefficients to ensure that they are used appropriately in the evaluation. Materials and Methods: The ICRP provides recommendations to regulatory and advisory agencies, mainly in the form of guidance on the fundamental principles on which appropriate radiological protection can be based. The FGR provides federal and state agencies with technical information to assist their implementation of radiation protection programs for the U.S. population. The system of radiation dose assessment and dose conversion coefficients in the ICRP and FGR is reviewed in this study. Results and Discussion: A thorough understanding of their background is essential for the proper use of dose conversion coefficients. The FGR dose assessment system was strongly influenced by the ICRP and the U.S. National Council on Radiation Protection and Measurements (NCRP), and is hence consistent with those recommendations. Moreover, the ICRP and FGR both used the scientific data reported by Biological Effects of Ionizing Radiation (BEIR) and United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) as their primary source of information. The difference between the ICRP and FGR lies in the fact that the ICRP utilized information regarding a population of diverse races, whereas the FGR utilized data on the American population, as its goal was to provide guidelines for radiological protection in the US. Conclusion: The contents of this study are expected to be utilized as basic research material in the areas of radiation protection and dose assessment.

방사능위해성평가 프로그램 RADCONS의 개발 및 적용 (Development and Application of Radiological Risk Assessment Program RADCONS)

  • 정효준;박미선;황원태;김은한;한문희
    • 환경영향평가
    • /
    • 제22권1호
    • /
    • pp.89-97
    • /
    • 2013
  • RADCONS Ver. 1.0 (RADiological CONSequence Assessment Program) was developed for radiological risk assessment in this study. A Gaussian plume model was used to analyze the fate and transport of radionuclides released into the air in case of accidents. Both single meterological data and time series meterological data can be used in RADCONS. To assess the radiological risk of the early phase after an accident, ED (Effective Dose) estimated by both deterministic and probabilistic approaches are presented. These EDs by deterministic and probabilistic will be helpful to efficient decision making for decision makers. External doses from deposited materials by time are presented for quantifying the effects of mid and late phases of an accident. A radiological risk assessment was conducted using RADCONS for an accident scenario of 1 Ci of Cs-137. The maximum of ED for radii of 1,000 meters from the accident point was 8.51E-4 mSv. After Monte-Carlo simulation, considering the uncertainty of the breathing rate and dispersion parameters, the average ED was 8.49E-4, and the 95 percentile was 1.10E-3. A data base of the dose coefficients and a sampling module of the meteorological data will be modified to improve the user's convenience in the next version.

선량평가 및 Display시스템 (A Rapid Dose Assessment and Display System Applicable to PWR Accident)

  • 문광남;육종철
    • Journal of Radiation Protection and Research
    • /
    • 제13권2호
    • /
    • pp.67-77
    • /
    • 1988
  • 원자력발전소의 비상사태 발생시 효과적인 비상대책 수립을 위하여 인근 주민에 대한 신속한 피폭선량 평가 시스템의 개발이 강조되고 있다. 여기서 개발한 시스템은 다양한 원전의 사고에 대해 인근 주민에 대한 방사선 영향의 신속한 평가 모델로서 마이크로 컴퓨터에 기초한 프로그램이며, 문답형의 메뉴방식의 사용자 입력구조를 가지고 있고 수행 결과의 출력은 표 또는 그래픽 형식의 구조를 가지고 있어서 신속한 피폭선량평가 수행뿐만 아니라 신속한 결과 판독이 가능하여 비상대책 활동을 위한 결정에 도움을 준다.

  • PDF

국내 원전 해체시 방사선환경영향평가 방안 (Preparation of Radiological Environmental Impact Assessment for the Decommissioning of Nuclear Power Plant in Korea)

  • 이상호;서형우;김창락
    • 방사성폐기물학회지
    • /
    • 제16권1호
    • /
    • pp.107-122
    • /
    • 2018
  • 국내 최초의 상업원전인 고리1호기가 2017년 6월에 영구 정지되었다. 고리1호기 해체를 시작으로 한국은 원전 해체시장에 본격적으로 발을 내딛는다. 원자력발전소 해체를 위해서는 고려해야 할 사항들이 많으며, 방사선환경영향평가 또한 그 중 하나이다. 방사선환경영향평가의 목적은 주변주민의 건강과 안전을 도모하기 위해, 해체 전 및 해체 중에 해당 시설에서 방출되는 방사성물질로부터 주변주민이 받는 피폭방사선량이 규제 제한치를 초과하지 않음을 확인하는 것이다. 현재 국내에는 해체시 방사선환경영향평가서를 작성하는데 필요한 세부지침이 미비한 상황으로, 다수의 원전 해체 경험을 보유한 미국의 해체시 방사선환경영향평가서를 비교 분석하여 국내 상황에 맞는 해체시 방사선환경영향평가 방안을 개발하였다.

Planning and decommissioning of a disused Theratron- 780 teletherapy machine and the dose assessment methodology for normal and radiological emergency conditions

  • Mohamed M.Elsayed Breky ;Muhammad S. Mansy;A.A. El-Sadek ;Yousif M. Mousa ;Yasser T. Mohamed
    • Nuclear Engineering and Technology
    • /
    • 제55권1호
    • /
    • pp.238-247
    • /
    • 2023
  • The present work represents a technical guideline for decommissioning a disused teletherapy machine model Theratron-780 and contains category one 60Co radioactive source. The first section predicts the dose rate from the source in case of normal and radiological emergency situations via FLUKA-MC simulation code. Moreover, the dose assessment for the occupational during the whole process is calculated and compared to the measured values. A suggested cordoned area for safety and security in a radiological emergency is simulated. The second section lists the whole process's technical procedures, including (preview, dismantle, securing, transport and storage) of the disused teletherapy machine. Results show that the maximum obtained accumulated dose for occupational were found to be 24.5 ± 4.9 μSv in the dismantle and securing process in addition to 3.5 ± 1.8 μSv during loading on the transport vehicle and unloading at the storage facility. It was found that the measured accumulated dose for workers is in good agreement with the estimated one by uncertainty not exceeding 5% in normal operating conditions.