Profile and Dose Distribution for Therapeutic Heavy Ion Beams

  • Sasaki, Hitomi;Komori, Masataka;Kohno, Toshiyuki;Kanai, Tatsuaki;Hirai, Masaaki;Urakabe, Eriko;Nishio, Teiji
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.211-213
    • /
    • 2002
  • The purpose of this work is acquiring some parameters of therapeutic heavy ion beams after penetrating a thick target. The experiments were performed using a pencil-like $\^$12/C beam of about 3 mm in diameter from NIRS-HIMAC, and the data were taken at several points of the target thickness for $\^$12/C beam of 290 MeV/u and 400 MeV/u. By the simultaneous measurements using some detectors, the atomic number of each fragment particle was identified, and the beam profile, the dose distribution and the LET spectrum for each element were derived.

  • PDF

Electron Energy Distribution for a Research Electron LINAC

  • Lim, Heuijin;Lee, Manwoo;Yi, Jungyu;Kang, Sang Koo;Kim, Me Young;Jeong, Dong Hyeok
    • Progress in Medical Physics
    • /
    • v.28 no.2
    • /
    • pp.49-53
    • /
    • 2017
  • The energy distribution was calculated for an electron beam from an electron linear accelerator developed for medical applications using computational methods. The depth dose data for monoenergetic electrons from 0.1 MeV to 8.0 MeV were calculated by the DOSXYZ/nrc code. The calculated data were used to generate the energy distribution from the measured depth dose data by numerical iterations. The measured data in a previous work and an in-house computer program were used for the generation of energy distribution. As results, the mean energy and most probable energy of the energy distribution were 5.7 MeV and 6.2 MeV, respectively. These two values agreed with those determined by the IAEA dosimetry protocol using the measured depth dose.

Evaluation of Metal Artifact Reduction for Orthopedic Implants (O-MAR) on Radiotherapy Treatment Planning (방사선 치료 계획 시 O-MAR (Metal Artifact Reduction for Orthopedic Implants) 적용의 유용성 평가)

  • Won, Huisu;Hong, Joowan;Kim, Sunyoung;Choi, Jaehyock;Cho, Jaehwan;Yang, Hanjoon;Lee, Jin;Lee, Sunyeob;Park, Cheolsoo
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.5
    • /
    • pp.217-223
    • /
    • 2014
  • The aim of this study is evaluation of dose distribution on radiation therapy planning system with the CT image of high-density material inserted phantom. Gammex 467 Tissue Characterization Phantom is used to acquire an image similar to the human tissues and insert a Titanium to generate metal artifact. The acquired images were reconstructed with Metal Artifact Reduction for Orthopedic Implants (O-MAR). By using the treatment planning system, the volume was analyzed and dose distribution was extracted. Photon dose distribution in linear accelerator was measured by the $MapCHECK^{TM}$ and compared with planned and measured dose distributions. In result of the comparative analysis, when artifact is generated by Titanium, The volume applied O-MAR was increased 6.8% to BR-12 Breast and 40.2% to LV 1 Liver. After O-MAR was used, Dose distribution was higher 1.4 to 1.6% than before. Consequently, The artifact caused by metal objects should be removed if possible, and after that used in the radiotherapy treatment plan can be considered to reduce errors.

Development of Self-Questionnaire for Internal Dose Assessment by Food Ingestion

  • JiEun Lee;Hyo Jin Kim;Yong-Uk Kye;Dong-Yeon Lee;Wol Soon Jo;Chang-Geun Lee;Jung-Ki Kim;Yeong-Rok Kang
    • Journal of Radiation Protection and Research
    • /
    • v.47 no.4
    • /
    • pp.204-213
    • /
    • 2022
  • Background: The accident at the Fukushima Daiichi nuclear power plant increased the level of anxiety related to the radioactive contamination of various foods sourced in Japan. Particularly, after the accident, the detection of artificial radionuclides in locally produced foods raised food safety concerns. In this study, the radioactivity concentrations and annual ingestions of 40K and 137Cs in food products commonly and frequently consumed by the general public were investigated, and the annual effective dose of each was evaluated. Materials and Methods: The 2016-2018 data from the Radiation Safety Management Report released by the Korea Nuclear Safety Technology Center was referenced for the evaluation of the amounts of 40K and 137Cs contained in food. Using the food-ingestion survey mentioned above as a reference, we selected 62 foods to include in our radioactivity concentration and dose assessment. We also developed a questionnaire and evaluated the responses from the subjects who answered the questionnaire. Results and Discussion: The radioactivity concentration of 137Cs was found to be close to or below the level of minimum detectable activity. Additionally, the annual ingestion of 62 foods was 294.77 kg/yr, the effective doses from 40K and 137Cs were 136.4 and 0.163 μSv/yr, respectively. Conclusion: Thus, the findings confirmed that the effective dose from 40K and 137Cs in food tends to be lower than the effective dose limit of 1 mSv/yr suggested by the International Commission on Radiological Protection (ICRP) Publication 60. The questionnaire developed in this study is expected to be useful for estimating the annual effective dose status of Korean adults who consume foods containing 40K and 137Cs.

A Study on Ways to Optimize the Period of Hospitalization During High-Dose $^{131}I$ Treatment of the Thyroid Cancer (갑상선암의 고용량 $^{131}I$ 치료 시 입원기간의 최적화방안 연구)

  • Baek, Seong-Min;Ko, Seong-Jin;Kim, Chang-Soo;Kim, Jung-Hoon;Kang, Se-Sik
    • Journal of radiological science and technology
    • /
    • v.33 no.3
    • /
    • pp.269-276
    • /
    • 2010
  • This study attempts to propose ways to optimize and improve the period of hospitalization for the radioiodine treatment by calculating the dose rate of patients treated with high-dose radioiodine by distance and time slot. As a result, 24 hours after the patient was treated with 100 mCi high-dose iodine, the dose rate was attenuated to $1,035{\mu}Sv/hr$ at the navel, to $109{\mu}Sv/hr$ at 50 cm, and to $33{\mu}Sv/hr$ at 100 cm. 24 hours after the patient was treated with 150 mCi high-dose iodine, the dose rate was attenuated to $637{\mu}Sv/hr$ at the navel, to $100{\mu}Sv/hr$ at 50 cm, and to $40{\mu}Sv/hr$ at 100 cm. 24 hours after the patient was treated with 180 mCi high-dose iodine, the dose rate was attenuated to $1,251{\mu}Sv/hr$ at the navel, $140{\mu}Sv/hr$ at 50 cm, and to $56{\mu}Sv/hr$ at 100 cm. In light of the current criterion for discharge recommended by the US Nuclear Regulatory Commission being $70.4{\mu}Sv/hr$, the present study indicates earlier discharge is feasible by applying a new scheme. This suggests that the proposed scheme in this study will help to solve the problem of shortage of treatment beds with the increasing trend of patients with thyroid cancer taken into consideration.

Evaluation of OSLD and EBT3 film for dose, energy, and angular dependence (OSLD와 EBT3 필름의 선량, 에너지, 방향의존성에 대한 평가)

  • Lee, Ju-seong;Kang, Bo-ram;Kwon, Hyeon-Kyung;Park, Ji-Young;Kim, Ju-Hye;Choi, Young-Se;Kim, Daehong
    • The Korean Journal of Food & Health Convergence
    • /
    • v.4 no.1
    • /
    • pp.15-22
    • /
    • 2018
  • A radiation dosimeter is important to assess quality assurance (QA) of radiation therapy devices and to estimate the radiation dose in vivo dosimetry. Recently, optically stimulated luminescence detector (OSLD) is widely used in clinical filed. Therefore, the purpose of this study is to evaluate dose, energy, and angular dependence of OSLD and EBT3 film. The absorbed dose in clinical linear accelerator (Linac) beam is calibrated for dose per monitor unit (MU). Dose, energy, and angular dependence of OSLD and EBT3 film are estimated after the calibration procedure. The absorbed dose is measured at 50, 100, 150, and 200 cGy in an 6 MV X-ray beam for dose dependence. A dose of 150 cGy is delivered to OSLD and EBT3 film with 6 and 10 MV photon energies for energy dependence. For measurements of angular dependence, angular positions of gantry are $0^{\circ}{\pm}80^{\circ}$ with 6 MV at 150 cGy. The results of dose dependence is linear for OSLD and EBT3 film. For the results of energy dependence, errors were 0.39% and 0.03% for OSLD and EBT3 film, respectively. The results of dose for angular is decreased from $0^{\circ}$ to ${\pm}80^{\circ}$ for both OSLD and EBT3 film. When angle of $0^{\circ}$ is normalized to 1, and the dose is decreased to 60 and 66% at $80^{\circ}$ for OSLD and EBT3 film, respectively. Dose and energy dependence of OSLD and EBT3 film are measured within the recommendation of manufacturer. Angular dependence is increased from $0^{\circ}$ to ${\pm}80^{\circ}$ for OSLD and EBT3 film. The characteristics of OSLD and EBT3 film are similar and expected to useful for clinical field.

Evaluation of absorbed dose in monkey and mouse using 18F-FDG PET and CT density information

  • Kim, Wook;Lee, Yong Jin;Park, Yong Sung;Cho, Doo-Wan;Lee, Hong-Soo;Han, Su-Cheol;Kang, Joo Hyun;Woo, Sang-Keun
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.3 no.1
    • /
    • pp.18-24
    • /
    • 2017
  • Patient-specific image-based internal dosimetry involves using the patient's individual anatomy and spatial distribution of radioactivity over time to obtain an absorbed dose calculation. Individual absorbed dose was calculated by accumulated activity multiply S-value of each organs. The aim of this study was to calculate the S-values using Monte Carlo simulation in monkey and mouse and evaluation of absorbed dose in each organ. Self-irradiation S-value of monkey heart self-irradiation was 3.15E-03 mGy-g/MBq-s, lung self-irradiation was 8.94E-04 mGy-g/MBq-s and liver self-irradiation S-value was 2.23E-03 mGy-g/MBq-s. Mouse heart self-irradiation S-value was 1.95E-01 mGy-g/MBq-s, lung was 9.59E-02 mGy-g/MBq-s, and liver was 1.40E-03 mGy-g/MBq-s. The results of this study show that the calculation protocol of image based individual absorbed dose of each organ using Monte Carlo simulation. Therefore, this study may be applied to calculate human specific absorbed dose.

Age-Specific Thyroid Internal Dose Estimation for Koreans

  • Kwon, Tae-Eun;Yoon, Seokwon;Ha, Wi-Ho;Chung, Yoonsun;Jin, Young Woo
    • Journal of Radiation Protection and Research
    • /
    • v.46 no.4
    • /
    • pp.170-177
    • /
    • 2021
  • Background: The International Commission on Radiological Protection is preparing to provide reference dose coefficients for environmental radioiodine intake based on newly developed age-specific biokinetic models. However, the biokinetics of iodine has been reported to be strongly dependent on the dietary intake of stable iodine; for example, the thyroidal uptake of iodine may be substantially lower in iodine-rich regions than in iodine-deficient regions. Therefore, this study attempted to establish a system of age-specific thyroid dose estimation for South Koreans, whose daily iodine intakes are significantly higher than that of the world population. Materials and Methods: Korean age-specific biokinetic parameters and thyroid masses were derived based on the previously developed Korean adult model and the Korean anatomical reference data for adults, respectively. This study complied with the principles used in the development of age-specific biokinetic models for world population and used the ratios of baseline values for each age group relative to the value for adults to derive age-specific values. Results and Discussion: Biokinetic model predictions based on the Korean age-specific parameters showed significant differences in iodine behaviors in the body compared to those predicted using the model for the world population. In particular, the Korean age-specific thyroid dose coefficients for 129I and 131I were considerably lower than those calculated for the world population (25%-76% of the values for the world population). Conclusion: These differences stress the need for Korean-specific internal dose assessments for infants and children, which can be achieved by using the data calculated in this study.

Evaluation of Internal Dosimetry according to Various Radionuclides Conditions in Nuclear Medicine Myocardial Scan: Monte Carlo Simulation (심근 핵의학 검사에서 다양한 방사성핵종 조건에 따른 내부피폭선량 평가: 몬테카를로 시뮬레이션)

  • Min-Gwan Lee;Chanrok Park
    • Journal of radiological science and technology
    • /
    • v.47 no.3
    • /
    • pp.213-218
    • /
    • 2024
  • The myocardial nuclear medicine examination is widely performed to diagnose myocardium disease using various radionuclides. Although image quality according to radionuclides has improved, the radiation exposure for target organ as well as peripheral organs should be considered. Here, the aim of this study was to evaluate absorbed dose (Gy) for peripheral organs in myocardial nuclear medicine scan from myocardium according to various scan environments based on Monte Carlo simulation. The simulation environment was modeled 5 cases, which were considered by radionuclides, number of injections, and radiodosage. In addition, the each radionuclide simulation such as distribution fraction was considered by recommended standard protocol, and the mesh computational female phantom, which is provided by International Commission on Radiological Protection (ICRP) 145, was used using the particle and heavy ion transport code system (PHITS) version 3.33. Based on the results, the closer to the myocardium, the higher the absorbed dose values. In addition, application for dual injection for radionuclides leaded to high absorbed dose compared with single injection for radionuclide. Consequently, there is difference for absorbed dose according to radionuclides, number of injections, and radiodosage. To detect the accurate diseased area, acquisition for improved image quality is crucial process by injecting radionuclides, however, we need to consider absorbed dose both target and peripheral inner organs from radionuclides in terms radiation protection for patient.

Feasibility of the 3D Printing Materials for Radiation Dose Reduction in Interventional Radiology (인터벤션 시술 시 환자의 선량감소를 위한 3D 프린팅 재료의 적용성 평가)

  • Cho, Yong-In
    • Journal of radiological science and technology
    • /
    • v.43 no.3
    • /
    • pp.169-176
    • /
    • 2020
  • Interventional radiology is performed under real-time fluoroscopy, and patients are exposed to a wide range of exposures for a long period of time depending on the examination and procedure. However, studies on radiation protection for patients during an intervention are insufficient. This study aims to evaluate the doses exposed during the intervention and the applicability of 3D printing materials. The organ dose for each intervention site was evaluated using a monte carlo simulatio. Also, the dose reduction effect of the critical organs was calculated when using a shielding device using 3D printing materials. As a result, the organ dose distribution for each intervention site showed a lower dose distribution for organs located far from the x-ray tube. It was analyzed that the influence of scattered rays was higher in the superficial organs of the back of the human body where x-rays were incident. The dose reduction effect on the critical organ using the 3D printing shield showed the highest testis among the gonads, and in the case of other organs, the dose reduction effect gradually decreased in the order of the eye, thyroid, breast, and ovary. Accordingly, it is judged that the 3D printed shield will be sufficiently usable as a shielding device for the radiation protection of critical organs.