• 제목/요약/키워드: Radiological Engineering

검색결과 777건 처리시간 0.035초

Comparison of Image Uniformity with Photon Counting and Conventional Scintillation Single-Photon Emission Computed Tomography System: A Monte Carlo Simulation Study

  • Kim, Ho Chul;Kim, Hee-Joung;Kim, Kyuseok;Lee, Min-Hee;Lee, Youngjin
    • Nuclear Engineering and Technology
    • /
    • 제49권4호
    • /
    • pp.776-780
    • /
    • 2017
  • To avoid imaging artifacts and interpretation mistakes, an improvement of the uniformity in gamma camera systems is a very important point. We can expect excellent uniformity using cadmium zinc telluride (CZT) photon counting detector (PCD) because of the direct conversion of the gamma rays energy into electrons. In addition, the uniformity performance such as integral uniformity (IU), differential uniformity (DU), scatter fraction (SF), and contrast-to-noise ratio (CNR) varies according to the energy window setting. In this study, we compared a PCD and conventional scintillation detector with respect to the energy windows (5%, 10%, 15%, and 20%) using a $^{99m}Tc$ gamma source with a Geant4 Application for Tomography Emission simulation tool. The gamma camera systems used in this work are a CZT PCD and NaI(Tl) conventional scintillation detector with a 1-mm thickness. According to the results, although the IU and DU results were improved with the energy window, the SF and CNR results deteriorated with the energy window. In particular, the uniformity for the PCD was higher than that of the conventional scintillation detector in all cases. In conclusion, our results demonstrated that the uniformity of the CZT PCD was higher than that of the conventional scintillation detector.

Trend Analysis on Korean and International Management for Activated Material Waste from Medical Linear Accelerator

  • Kwon, Na Hye;Jang, Young Jae;Kim, Dong Wook;Shin, Dong Oh;Kim, Kum Bae;Kim, Jin Sung;Choi, Sang Hyoun
    • 한국의학물리학회지:의학물리
    • /
    • 제31권4호
    • /
    • pp.194-204
    • /
    • 2020
  • This study investigated and analyzed the Korean and international status of radioactive waste management for medical linear accelerators (linacs) and proceed prior research to suggest radiation safety regulations and guidelines for the safe use of radiation. We analyzed the number of linacs installed in the radiation oncology departments of 103 institutions. In addition, we analyzed the procedures and standards for disposal in Korea and foreign countries. For foreign countries, we analyzed the status based on reports from the United States, Japan, Europe, and Canada. A total of 182 linacs are installed in Korea and 95% of them use more than 10 MV of energy. In Korea, standards for managing radioactive waste from a linac, disposal procedures, and clearance criteria have yet to be established. Therefore, radioactive waste is disposed of in different ways depending on the hospitals where they originate. Japan, the US, and Canada have recommended clearance levels and procedures for linacs. Other countries have provided management guidelines for research or large-scale accelerators, but not for medical purposes. In this study, we investigated the management of radioactive waste from medical linacs in Korea and abroad. Several foreign countries have suggested a clearance level and criteria for disposing of waste storage drums. For the safe management of medical linacs, it is necessary to establish safety management regulations. In Korea, standards for disposal, such as radiation or dose limits, are required for medical linacs. A system for clearance when disposing at a medical institution should be created.

Particle Swarm Optimization을 이용한 PET/CT와 CT영상의 정합 (Image Registration for PET/CT and CT Images with Particle Swarm Optimization)

  • 이학재;김용권;이기성;문국현;주성관;김경민;천기정;최종학;김창균
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제32권2호
    • /
    • pp.195-203
    • /
    • 2009
  • 영상정합 기술은 두 개 이상의 영상을 서로 맞추어, 각각의 영상이 가지고 있는 단점을 보완하여, 새로운 정보를 획득하게 하는 기술이다. 본 논문은 의료 영상간의 2D 영상 정합을 통해 환자의 점진적 병세파악에 도움을 주는 것을 목적으로 하고 있다. 서로 다른 시점과 장비로부터 얻어진 CT와 PET/CT영상을 정합하기 위하여 정확한 해부학적 정보를 제공하는 CT영상간의 정합을 먼저 수행하고 이를 통하여 얻어진 기하학적 정합파라미터들을 PET 영상에 적용하여, 독립 CT영상 위에 PET영상을 중첩하였다. 정합작업을 위해 먼저 각각의 CT영상에 대해 전처리 작업을 실시하였고, 영상의 변형은 affine 좌표변환을 이용하였다. 정합할 영상간의 유사도 평가를 위해 mutual information을 이용하였으며, 빠르고 정확한 정합을 위하여 최적화 알고 리듬인 particle swarm optimization 방법을 이용하였다. 이를 통해 실제 환자의 독립 CT와 PET/CT영상을 이용하여 실험하였고, PET/CT의 영상에서 확인할 수 있었던 병소에 대한 해부학적 위치 정보가 영상정합 과정을 통해 독립 CT 영상에서도 동일한 위치에 표시됨을 확인하였다. 제안된 알고리듬은 PET/CT 뿐만 아니라 향후 도입될 SPECT/CT, MRI/PET 등 다중영상기기와 기존의 독립 CT 영상기기와의 정합에도 폭넓게 사용될 것으로 기대된다.

  • PDF

디지털 영상 시스템에서 선량 크리프 최소화를 위한 부가 필터 두께 권고 기준의 재설정에 대한 연구 (The Necessity of Resetting the Filter Criteria for the Minimization of Dose Creep in Digital Imaging Systems)

  • 김교태;김금배;강상식;박지군
    • 한국방사선학회논문지
    • /
    • 제13권5호
    • /
    • pp.757-763
    • /
    • 2019
  • 최근 넓은 동적 범위 특성을 제공하는 평판 디텍터 개발을 바탕으로 의료보건 환경이 디지털화되고 있는 현 시점에서 적절한 필터 두께의 재설정이 요구되고 있으나, 현 임상에서는 기존 아날로그 시스템에서 연구된 정보를 바탕으로 NCRP에서 제안한 권고 기준을 이용하고 있다. 이에 본 연구에서는 디지털방사선 촬영에서 알루미늄 필터를 이용하여 환자선량 최적화와 더불어 선량크리프의 최소화 가능성을 고찰하였다. 연구 결과, 알루미늄 필터의 두께를 증가함에 따라 유사한 선예도를 가지는 의료영상을 획득 시 피폭되는 피부입사선량을 최대 19.3% 저감할 수 있는 것으로 나타났으나, 영상학적 관점에서 중요한 해상력이 1.01 lp/mm의 큰 변화가 분석되었다. 이러한 해상력의 변화는 X선 빔 경화 현상으로 인하여 피사체에서 발생하는 산란선이 증가하기 때문으로 사료되며, 산란 열화 인자를 통하여 산란선량에 의한 영향이 증가하는 것을 정량적으로 검증하였다. 하지만, 최근 개발되어 광범위하게 적용되고 있는 평판 디텍터는 방사선에 대한 민감도가 높고 넓은 동적 범위 특성을 가지므로 필터 두께에 따라 산란선의 비율에 대한 증가분과 대응하여 적정한 해상력을 유지할 수 있을 것으로 사료되며, 더 나아가 피폭선량 저감을 통해 선량크리프를 최소화 할 수 있을 것으로 기대된다.

The Effect of Sub-chronic Whole-Body Exposure to a 1,950 MHz Electromagnetic Field on the Hippocampus in the Mouse Brain

  • Son, Yeonghoon;Jeong, Ye Ji;Kwon, Jong Hwa;Choi, Hyung-Do;Pack, Jeong-Ki;Kim, Nam;Lee, Yun-Sil;Lee, Hae-June
    • Journal of electromagnetic engineering and science
    • /
    • 제15권3호
    • /
    • pp.151-157
    • /
    • 2015
  • The increasing use of mobile phones has raised public concern about the possible biological effects of radiofrequency electromagnetic field (RF-EMF) exposure on the human brain. To investigate the potential effect of RF-EMF exposure on the brain, we examined the behaviors and hippocampal morphology of C57BL/6 mice after sub-chronic exposure to RF-EMFs with a relatively high SAR level (5.0 W/kg). We applied a 2-hour daily exposure of WCDMA 1,950 MHz using a reverberation chamber that was designed for whole-body exposure for 60 days. In the behavioral tests, RF-EMF did not alter the physical activity or long-term memory of mice. Moreover, no alteration was found in the neuronal and glial cells in the hippocampus by RF-EMFs. In this study, we showed that sub-chronic whole body RF exposure did not produce memory impairment and hippocampal morphological alteration in C57BL/6 mice.

Protective Activity against Ionizing Radiation of Antioxidative Plants Indigenous to Korea

  • Jung, Myung-Sun;Kang, Kyoung-Ah;Zhang, Rui;Chae, Sung-Wook;Yoo, Byoung-Sam;Yang, Young-Taek;Lee, Nam-Ho;Park, Jae-Woo;Hyun, Jin-Won
    • Natural Product Sciences
    • /
    • 제12권1호
    • /
    • pp.1-7
    • /
    • 2006
  • We have screened the cytoprotective effect on ${\gamma}-ray$ radiation induced oxidative stress from forty one Korean plant extracts. Carpinus laxiflora (caulis), Quercus salicina (caulis), and Castanopsis cuspidata (caulis) were found to scavenge 1,1-diphenyl-2-picrylhydrazyl (DPPH) radical and intracellular reactive oxygen species (ROS). As a result, extracts of three plants reduced cell death of Chinese hamster lung fibroblast (V79-4) cells induced by $H_2O_2$ treatment. In addition, these extracts protected cell death of V79-4 cells damaged by ${\gamma}-ray$ radiation. In addition, these extracts scavenged ROS generated by radiation. Taken together, the results suggest that Carpinus laxiflora, Quercus salicina, and Castanopsis cuspidata protect V79-4 cells against oxidative damage by radiation through scavenging ROS.

INVOLVEMENT OF p27CIP/KIP IN HSP25 OR INDUCIBLE HSP70 MEDIATED ADAPTIVE RESPONSE BY LOW DOSE RADIATION

  • Seo, Hang-Rhan;Chung, Hee-Yong;Lee, Yoon-Jin;Baek, Min;Bae, Sang-Woo;Lee, Su-Jae;Lee, Yun-Sil
    • Nuclear Engineering and Technology
    • /
    • 제38권3호
    • /
    • pp.285-292
    • /
    • 2006
  • Thermoresistant (TR) clones of radiation-induced fibrosarcoma (RIF) cells have been reported to show an adaptive response to 1cGy of low dose radiation, and HSP25 and inducible HSP70 are involved in this process. In this study, to further elucidate the mechanism by which HSP25 and inducible HSP70 regulate the adaptive response, HSP25 or inducible HSP70 overexpressed RIF cells were irradiated with 1cGy and the cell cycle was analyzed. HSP25 or inducible HSP70 overexpressed cells together with TR cells showed increased G1 phase after 1cGy irradiation, while RIF cells did not. $[^3H]-Thymidine$ and BrdU incorporation also indicated that both HSP25 and inducible HSP70 are involved in G1 arrest after 1cGy irradiation. Molecular analysis revealed upregulation of p27Cip/Kip protein in HSP25 and inducible HSP70 overexpressed cells, and cotransfection of p27Cip/Kip antisense abolished the induction of the adaptive response and 1cGy-mediated G1 arrest. The above results indicate that induction of an adaptive response by HSP25 and inducible HSP70 is mediated by upregulation of p27Cip/Kip protein, resulting in low dose radiation-induced G1 arrest.

Protective Activity Against Oxidative Stress of Plants Indigenous to Korea

  • Jung Myung Sun;Kang Kyoung Ah;Zhang Rui;Chae Sungwook;Yoo Byoung-Sam;Yang Young Taek;Lee Nam Ho;Park Jae Woo;Hyun Jin Won
    • Toxicological Research
    • /
    • 제21권4호
    • /
    • pp.279-284
    • /
    • 2005
  • We have screened the cytoprotective effect against $H_2O_2$ and $\gamma-ray$ radiation induced oxidative stress from 32 Korean plants. Betula ermani var.saitoana (caulis, leaves), Rosa wichuraiana (caulis), Sorbus commixta (caulis), Weigela florida (leaves), Cirsium rhinoceros (whole plant), and Viburnum erosum (caulis) were found to scavenge 1, 1-diphenyl-2-picrylhydrazyl (DPPH) radical and intracellular reactive oxygen species (ROS). As a result, extracts of six plants reduced cell death of Chinese hamster lung fibroblast (V79-4) cells induced by $H_2O_2$ treatment. In addition, these extracts protected cell death of V79-4 cells damaged by $\gamma-ray$ radiation. In addition, these extracts scavenged ROS generated by radiation. Taken together, the results suggest that Betula ermani var. saitoana, Rosa wichuraiana, Sorbus commixta, Weigela florida, Cirsium rhinoceros, and Vibumum erosum protect V79-4 cells against oxidative damage by radiation through scavenging ROS.

Development and Performance Evaluation of the First Model of 4D CT-Scanner

  • Endo, Masahiro;Mori, Shinichiro;Tsunoo, Takanori;Kandatsu, Susumu;Tanada, Shuji;Aradate, Hiroshi;Saito, Yasuo;Miyazaki, Hiroaki;Satoh, Kazumasa;Matsusita, Satoshi;Kusakabe, Masahiro
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.373-375
    • /
    • 2002
  • 4D CT is a dynamic volume imaging system of moving organs with an image quality comparable to conventional CT, and is realized with continuous and high-speed cone-beam CT. In order to realize 4D CT, we have developed a novel 2D detector on the basis of the present CT technology, and mounted it on the gantry frame of the state-of-the-art CT-scanner. In the present report we describe the design of the first model of 4D CT-scanner as well as the early results of performance test. The x-ray detector for the 4D CT-scanner is a discrete pixel detector in which pixel data are measured by an independent detector element. The numbers of elements are 912 (channels) ${\times}$ 256 (segments) and the element size is approximately 1mm ${\times}$ 1mm. Data sampling rate is 900views(frames)/sec, and dynamic range of A/D converter is 16bits. The rotation speed of the gantry is l.0sec/rotation. Data transfer system between rotating and stationary parts in the gantry consists of laser diode and photodiode pairs, and achieves net transfer speed of 5Gbps. Volume data of 512${\times}$512${\times}$256 voxels are reconstructed with FDK algorithm by parallel use of 128 microprocessors. Normal volunteers and several phantoms were scanned with the scanner to demonstrate high image quality.

  • PDF

Analysis of Physical Properties for Various Compositions of Reusable LMG and LCV Micelle Gel

  • Kang, Jin Mook;Lee, Dong Han;Cho, Yu Ra;Hwang, Seon Bung;Ji, Young Hoon;Ahn, So Hyun;Keum, Ki Chang;Lee, Re Na;Cho, Sam Ju;Noh, Insup
    • 한국의학물리학회지:의학물리
    • /
    • 제27권4호
    • /
    • pp.175-179
    • /
    • 2016
  • In this study, we evaluated the reusable leuco malachite green (LMG) micelle gel properties dependent on various components of chemical concentration and compared with leuco crystal violet (LCV). The gels were delivered to 10, 20, 30, 40 and 50 Gy at 6 MV photon beam from linear accelerator and analyzed using spectrophotometry. We confirmed that the reusable LMG and LVC absorbance wavelength peak were made up at 630 nm and 600 nm respectively. The transparency of reusable LMG decreased with higher amount of trichloroacetic acid (TCAA) and lower reusable LMG dyes. 1 mM reusable LMG was the lowest transparency. The sensitivity was increased depending on lower trichloroacetic acid (TCAA) concentrations and the amount of suitable surfactant (Triton X-100), which was found to be 7 mM. However, we were not able to investigate sensitivity effects factor from reusable LMG dyes. The gel dosimeter containing 16 mM TCAA, 7 mM Triton X-100 gel dosimeter showed the highest sensitivity at $0.0021{\pm}0.0001cm^{-1}.Gy^{-1}$. The sensitivity of LCV was found to be higher than reusable LMG at $0.0037{\pm}0.0005cm^{-1}.Gy^{-1}$. The reusable LMG and LCV dose responses were shown to be $R^2=0.997$, $R^2=0.999$ respectively, as stable measurement results. Future research is necessary to improve dose sensitivity, dose rate dependency and gel fading with extensive chemical formulations.