• 제목/요약/키워드: Radiological Effects

검색결과 588건 처리시간 0.035초

The Effects of a Thyroid Shield Made of a Tissue-Equivalent Material on the Reduction of the Thyroid Exposure Dose in Panoramic Radiography (파노라마촬영 시 조직등가물질을 이용한 갑상선보호대의 갑상선피폭선량 감소효과)

  • Lee, Hye-Lim;Kim, Hyun-Yung;Choi, Hyung-Wook;Lee, Hye-Mi;Lim, Chang-Seon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제13권5호
    • /
    • pp.2278-2284
    • /
    • 2012
  • Exposure-dose reducing effect was measured by using bolus, a tissue-equivalent material as a shield to obtain useful diagnostic images while minimizing the radiation exposure of thyroid which is highly sensitive to radiation during panoramic radiography. The experiment was performed within the period of 1 June 2001 through 30 June 2011 by measuring entrance surface dose and deep dose at the thyroid-corresponding site of a head and neck phantom. As a result, the entrance surface dose in the thyroid for using no shield was 43.84 ${\mu}Gy$ on the average, and the thyroid shield of bolus 10 mm in thickness reduced the dose by 15.45 ${\mu}Gy$(35.24%) to 28.39 ${\mu}Gy$ on the average. The use of a 20 mm thyroid shield resulted in the dose of 25.38 ${\mu}Gy$ on the average, a 18.46 ${\mu}Gy$(42.10%) drop from 43.84 ${\mu}Gy$ for using no shield. On the site 20 mm below the surface, a thyroid shield 10 mm in thickness had no dose-reducing effect, while a 20 mm thyroid shield reduced the dose by 0.06 mSv(20%).

Antioxidative and Anti-inflammatory Effects of Extracts from Different Organs of Cirsium japonicum var. ussuriense (엉겅퀴(Cirsium japonicum var. ussuriense) 부위별 추출물의 항산화 및 항염증 효과)

  • Mok, Ji-Ye;Kang, Hyun-Ju;Cho, Jung-Keun;Jeon, In-Hwa;Kim, Hyeon-Soo;Park, Ji-Min;Jeong, Seung-Il;Shim, Jae-Suk;Jang, Seon-Il
    • The Korea Journal of Herbology
    • /
    • 제26권4호
    • /
    • pp.39-47
    • /
    • 2011
  • Objective: The roots, leaves, flowers, stems and seeds of Cirsium japonicum var. ussuriense are often used in treatment of human diseases such as hemorrhage, blood congestion and inflammation. Focusing our attention on natural and bioavailable sources of antioxidants and anti-inflammation, we undertook to investigate the antioxidant and anti-inflammatory properties of Cirsium japonicum var. ussuriense used as a folk medicine in Korea. Methods: The extracts of the leaves, stems, flowers, seeds and roots from C. japonicum var. ussuriense were prepared by extracting with water or 80% ethanol. Total flavonoids and polyphenols were measured by a colorimetric assay. The free radical scavenging activity of the extract was analyzed by the DPPH (1,1-diphenyl-2-picryl hydrazyl), ABTS (2,2'-azino-bis(3-ethylbenzthiazoline-6-sulfonic acid) and Griess reagent assay. An oxidative product of nitric oxide (NO), was measured in the culture medium by the Griess reaction. The level of prostaglandin $E_2$ ($PGE_2$) was measured by enzyme-linked immunosorbent assay. The expressions of inducible nitric oxide synthase (iNOS) and cyclooxygenase-2 (COX-2) were measured by Western blot analysis. Results: Total flavonoid and polyphenol amounts of the leaves (CLE) and flowers (CFE) showed higher than those of the seed extract (CSE), stem extract (CSTE) and roots (CRE). CLE and CFE also showed the high antioxidant activities such as DPPH, NO-like and ABTS radical scavenging activity. An antioxidant activities of these water extracts showed higher than those of 80% ethanol extracts. We investigated the anti-inflammatory effects of CLE on lipopolysaccharide (LPS)-stimulated RAW 264.7 cells. CLE significantly suppressed the levels of the inflammatory mediators such as NO and prostaglandin $E_2$ ($PGE_2$) in dose dependant. Furthermore, the levels of iNOS and COX-2 protein expressions were markedly suppressed by the treatment with CLE extract in a dose dependent manner. Conclusions: These results suggest that CLE water extract has a higher anoxidant and anti-inflammatory activity, these properties may contribute to the oxidative and inflammatory related disease care.

Flow Effects on Tailored RF Gradient Echo (TRFGE) Magnetic Resonance Imaging : In-flow and In-Plane Flow Effect (Tailored RF 경자사계방향 (TRFGE} 자기공명영상(MRI)에서 유체에 의한 영상신호 변화 : 유체유입효과와 영상면내를 흐르는 유체의 효과에 대하여)

  • Mun, Chi-Ung;Kim, Sang-Tae;No, Yong-Man;Im, Tae-Hwan;Jo, Jang-Hui
    • Journal of Biomedical Engineering Research
    • /
    • 제18권3호
    • /
    • pp.243-251
    • /
    • 1997
  • In this paper, we have reported two interesting flow effects arising in the TRFGE sequence using water flow phantom. First, we have shown that the TRFGE sequence is indeed not affected by "in-flow" effect from the unsaturated spins flowing into the imaging slice. Second, the enhancement of "in-plane flow" signal in the readout gradient direction was observed when the TRFGE sequence was used without flow compensation. These two results have many interesting applications in MR imaging other than fMRI. Results obtained were also compared with the results obtained by the conventional gradient echo(CGE) imaging. Experiments were performed at 4.7T MRI/S animal system (Biospec, BRUKER, Switzerland). A cylindrical phantom was made using acryl and a vinyl tube was inserted at the center(Fig. 1). The whole cylinder was filled with water doped with $MnCl_2$ and the center tube was filled with saline which flows in parallel to the main magnetic field along the tube. Tailored RF pulse was designed to have quadratic ($z^2$) phase distribution in slice direction(z). Imaging parameters were TR/TE = 55~85/10msec, flip angle = $30^{\circ}$, slice thickness = 2mm, matrix size = 256${\times}$256, and FOV= 10cm. In-flow effect : Axial images were obtained with and without flow using the CGE and TRFGE sequences, respectively. The flow direction was perpendicular to the image slice. In-plane flow : Sagittal images were obtained with and without flow using the TRGE sequence. The readout gradient was applied in parallel to the flow direction. We have observed that the "in-flow" effect did not affect the TRFGE image, while "in-plane flow" running along the readout gradient direction enhanced the signal in the TRFGE sequence when flow compensation gradient scheme was not used.

  • PDF

THE EVALUATION OF CYTOTOXICITY AND BIOCOMPATIBILITY OF TI-TA-NB-BASE ALLOY (Ti-Ta-Nb계 합금의 세포독성과 생체적합성의 평가)

  • Cui De-Zhe;Vang Mong-Sook;Yoon Taek-Rin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • 제44권2호
    • /
    • pp.250-263
    • /
    • 2006
  • Statement of problem: Ti-alloy has been used widely since it was produced in the United States in 1947 because it has high biocompatibility and anticorrosive characteristics. Purpose: The pure titanium, however, was used limitedly due to insufficient mechanical charateristics and difficult manufacturing process. Our previous study was focused on the development of a new titanium alloy. In the previous study we found that the Ti-Ta-Nb alloy had better mechanical characteristics and similar anticorrosive characteristics to Ti-6Al-4V Material and methods: In this study, the cytotoxicity of the Ti-Ta-Nb alloy was evaluated by MTT assay using MSCs(Mesenchaimal stem cells) and L929 cells(fibroblast cell line). The biocompatibility of the Ti-Ta-Nb alloy was performed by inserting the alloy into the femur of the rabbits and observing the radiological and histological changes surrounding the alloy implant. Results: 1. In the cytotoxicity test using MSCs, the 60% survival rate was observed in pure titanium, 84% in Ti-6Al-4V alloy and 95% in Ti-10Ta-10Nb alloy. 2. In the animal study, the serial follow-up of the radiographs showed no separation or migration revealing gradual bone ingrowth surrounding the implants. Similar radiographic results were obtained among three implant groups pure titanium, Ti-6Al-4V alloy and Ti-10Ta-10Nb alloy. 3. In the histologic examination of the bone block containing the implants. the bone ingrowth was prominent around the implants with the lapse of time. There was no signs of any tissue rejection, degeneration, or inflammation. Active bone ingrowth was observed around the implants. In the comparison of the three groups, the rate of bone ingrowth was better in the Ti-10Ta-10Nb alloy group than those in pure titanium group or Ti-6Al-4V alloy group. In conclusion, Ti-10Ta-10Nb alloy revealed better biocompatibility in survival rate of the cells and bone ingrowth around the implants. Therefore we believe a newly developed Ti-10Ta-10Nb alloy can replace currently used Ti-6Al-4V alloy to increase biocompatibility and to decrease side effects. Conclusion: In conclusion, Ti-10Ta-10Nb alloy revealed better biocompatibility in survival rate of the cells and bone ingrowth around the implants. Therefore we believe a newly developed Ti-10Ta-10Nb alloy can replace currently used Ti-6Al-4V alloy to increase biocompatibility and to decrease side effects.

Effects of Stray Light in Blue-light Blocking Lens on the Quality of Image (청색광 차단렌즈에서 미광이 상의 질에 미치는 영향)

  • Yuk, Ju Sung;Yang, Seok-Jun;Kim, Yong Gwon;Choi, Eun Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제17권5호
    • /
    • pp.612-618
    • /
    • 2016
  • The aim of this study is to investigate the effects of stray light originating from the blue-light blocking lens on the quality of the image. After designing the ideal spectacle lens, anti-reflection spectacle lens without internal reflection, anti-reflection spectacle lens with internal reflection, and blue-light blocking lens with internal reflection, the light intensity distribution and stray light distribution were derived. The designed spectacle lenses are meniscus lenses with a refractive power of 0.00 D, refractive index of 1.56, and a radius of 155.15 mm. The peaks of reflectance of the 4 types of blue-light blocking lenses are in the range between 430 nm and 440 nm, and their reflectances are 5%, 10%, 15%, and 20%, respectively. According to the analysis results, as the reflectance of the blue-light blocking lens increases, the light intensity in the center of the lens decreases and the intensity of the stray light in the center-periphery and periphery of the lens increases. This trend appeared to intensify with increasing reflectance of the blue-light blocking lenses. Because the increase in the reflectance of the blue-light blocking lens degrades the quality of the image by increasing the intensity of the stray light in the center-periphery and periphery of the lens, its reflectance needs to be adjusted by varying the blue-light blocking ratio and the luminous transmittance, in order to diminish the level of visual discomfort.

Effects of Tube Voltage and Tube Current on Exposure Index : Focused on Radiographic Images of Cone Pyramid Phantom (관전압과 관전류량이 노출 지수에 미치는 영향 : 원뿔형 피라미드 팬텀 방사선영상 중심으로)

  • Seoung, You-Hun
    • Journal of the Korean Society of Radiology
    • /
    • 제13권5호
    • /
    • pp.749-755
    • /
    • 2019
  • In this study, we investigated the effects of tube voltage (kVp) and tube current (mAs) on an exposure index (EI) applied to a digital radiography. There used an inverter type digital X-ray generator and an image receptor (IR) utilized a portable wireless detector without a grid. Radiographic images were acquired using a cone pyramid phantom produced using a 3D printer. The X-ray tube voltage was increased from 40 kVp to 120 kVp with 10 kVp increment, and the tube current was increased from 1 mAs to 128 mAs with the twice increment. As a result, kVp had logarithmic relationship with the EI as high $R^2$ value, and mAs had a very high linear relationship too. Also, there was a high correlation between the area dose and the EI of the IR, with the $R^2$ value being 0.76 or more. In conclusion, it had showed that mAs affected the EI linearly, and that it could be advantageous to adjust the easy-to-predict mAs to maintain proper image qualities.

Public Exposure to Natural Radiation and the Associated Increased Risk of Lung Cancer in the Betare-Oya Gold Mining Areas, Eastern Cameroon

  • Joseph Emmanuel Ndjana Nkoulou II;Louis Ngoa Engola;Guy Blanchard Dallou;Saidou;Daniel Bongue;Masahiro Hosoda;Moise Godefroy Kwato Njock;Shinji Tokonami
    • Journal of Radiation Protection and Research
    • /
    • 제48권2호
    • /
    • pp.59-67
    • /
    • 2023
  • Background: This study aims to reevaluate natural radiation exposure, following up on our previous study conducted in 2019, and to assess the associated risk of lung cancer to the public residing in the gold mining areas of Betare-Oya, east Cameroon, and its vicinity. Materials and Methods: Gamma-ray spectra collected using a 7.62 cm×7.62 cm in NaI(Tl) scintillation spectrometer during a car-borne survey, in situ measurements and laboratory measurements performed in previous studies were used to determine the outdoor absorbed dose rate in air to evaluate the annual external dose inhaled by the public. For determining internal exposure, radon gas concentrations were measured and used to estimate the inhalation dose while considering the inhalation of radon and its decay products. Results and Discussion: The mean value of the laboratory-measured outdoor gamma dose rate was 47 nGy/hr, which agrees with our previous results (44 nGy/hr) recorded through direct measurements (in situ and car-borne survey). The resulting annual external dose (0.29±0.09 mSv/yr) obtained is similar to that of the previous study (0.33±0.03 mSv/yr). The total inhalation dose resulting from radon isotopes and their decay products ranged between 1.96 and 9.63 mSv/yr with an arithmetic mean of 3.95±1.65 mSv/yr. The resulting excess lung cancer risk was estimated; it ranged from 62 to 216 excess deaths per million persons per year (MPY), 81 to 243 excess deaths per MPY, or 135 excess deaths per MPY, based on whether risk factors reported by the U.S. Environmental Protection Agency, United Nations Scientific Committee on the effects of Atomic Radiation, or International Commission on Radiological Protection were used, respectively. These values are more than double the world average values reported by the same agencies. Conclusion: There is an elevated level of risk of lung cancer from indoor radon in locations close to the Betare-Oya gold mining region in east Cameroon. Therefore, educating the public on the harmful effects of radon exposure and considering some remedial actions for protection against radon and its progenies is necessary.

Time Dependent Changes in Platelet-Derived Growth Factor(PDGF) and PDGF ${\alpha}$ - and ${\beta}$ - Receptors Following Gamma-Irradiation of Rat Plasma and Sciatic Nerve (감마선 조사에 따른 흰쥐의 혈장 및 좌골신경의 혈소판-유래성 성장인자(PDGF)와 PDGF ${\alpha}$ - 및 ${\beta}$ - 수용체의 시간 의존성 변화)

  • Lim, Han-Young;Nam, Sang-Yul
    • Journal of radiological science and technology
    • /
    • 제21권1호
    • /
    • pp.79-87
    • /
    • 1998
  • The total-bodies of 10 week-old Sprague-Dawley rats were irradiated with single doses 4.5 and 7.5 Gy, respectively. The effects on plasma and sciatic nerve platelet-derived growth factor(PDGF) concentrations and sciatic nerve PDGF ${\alpha}$ -and ${\beta}$ -receptors densities were examined up to 10 days post-treatment. There was no consistent significant variation in the plasma and sciatic nerve PDGF concentrations in time over the period of study between 4.5 and 7.5 Gy groups. Plasma PDGF concentrations were significantly reduced to 58% of control values between 5 and 10 days with 4.5 Gy and to 51% of control values as percentage of control values between 5 and 10 days with 7.5 Gy after irradiation, respectively(p<0.05). Sciatic nerve PDGF concentrations were increased to 118% of control values at 1 day with 4.5 Gy and to 130% of control values at 1 day with 7.5 Gy after irradiation, respectively(p>0.05). After irradiation, the levels of PDGF ${\alpha}$ -receptor protein density were reduced to 33% of control values at 2 days with 4.5 Gy and to 50% at 2 days with 7.5 Gy, while the levels of PDGF ${\beta}$-receptor protein density were reduced to maximally 26% of control values at 2 days with 4.5 Gy and to 27% at 2 days with 7.5 Gy, respectively, but both initial decreased levels of those were increased subsequently after 2 days following irradiation. These results suggest that the radiation-induced alteration of plasma and sciatic nerve PDGF concentrations, and sciatic nerve PDGF ${\alpha}$ -and ${\beta}$ -receptors densities may be involved in the pathogenesis of bone marrow stem cell and peripheral neuron damages.

  • PDF

Image Evaluation and Exposure Dose with the Application of Tube Voltage and Adaptive Statistical Iterative Reconstruction of Low Dose Computed Tomography (저 선량 전산화단층촬영의 관전압과 적응식 통계적 반복 재구성법 적용에 따른 영상평가 및 피폭선량)

  • Moon, Tae-Joon;Kim, Ki-Jeong;Lee, Hye-Nam
    • Journal of radiological science and technology
    • /
    • 제40권2호
    • /
    • pp.261-267
    • /
    • 2017
  • The study has attempted to evaluate and compare the image evaluation and exposure dose by respectively applying filter back projection (FBP), the existing test method, and adaptive statistical iterative reconstruction (ASIR) with different values of tube voltage during the low dose computed tomography (LDCT). With the image reconstruction method as basis, chest phantom was utilized with the FBP and ASIR set at 10%, 20% respectively, and the change of tube voltage (100 kVp, 120 kVp). For image evaluation, back ground noise, signal-noise ratio (SNR) and contrast-noise ratio (CNR) were measured, and, for dose assessment, CTDIvol and DLP were measured respectively. In terms of image evaluation, there was significant difference in ascending aorta (AA) SNR and inpraspinatus muscle (IM) SNR with the different amount of tube voltage (p < 0.05). In terms of CTDIvol, the measured values with the same tube voltage of 120 kVp were 2.6 mGy with no-ASIR and 2.17 mGy with 20%-ASIR respectively, decreased by 0.43 mGy, and the values with 100 kVp were 1.61 mGy with no-ASIR and 1.34 mGy with 20%-ASIR, decreased by 0.27 mGy. In terms of DLP, the measured values with 120 kVp were $103.21mGy{\cdot}cm$ with no-ASIR and $85.94mGy{\cdot}cm$ with 20%-ASIR, decreased by $17.27mGy{\cdot}cm$ (about 16.7%), and the values with 100 kVp were $63.84mGy{\cdot}cm$ with no-ASIR and $53.25mGy{\cdot}cm$ with 20%-ASIR, a decrease by $10.62mGy{\cdot}cm$ (about 16.7%). At lower tube voltage, the rate of dose significantly decreased, but the negative effects on image evaluation was shown due to the increase of noise.

A Study on Reduction Effect of Processing Wastewater by Introduction of PACS (PACS 도입에 의한 현상시스템 폐수 감소효과에 관한 연구)

  • Ko, Shin-Kwan;Han, Dong-Kyoon;Kim, Wook-Dong;Kang, Bung-Sam;Yang, Han-Jun
    • Journal of radiological science and technology
    • /
    • 제30권2호
    • /
    • pp.167-175
    • /
    • 2007
  • There are some positive effects by the introduction of PACS(Picture Archiving Communication System). This study is to analyze the mutual relation between before and after of the introduction of PACS in terms of the environment effect. It is supposed to cause the reduction of developing and fixing wastewater according to the increase in the rate of a non-film. This study will also show the amount of wastewater. Target places were the department of image medicine(diagnostic radiation) of the general hospitals in Seoul and Gyeonggi-Do, which are equiped with full PACS. The authors examined questionnaires on the number of projection, the number of indirect projection, the amount of the film used, the number of radiation image CD loan, the amount of the developing and fixing solution used, the change of the amount of fixing wastewater. According to the analysis, we analyzed the change of the amount of developing and fixing solution per a film and the change of the amount of developing and fixing wastewater which is supposed to be reduced proportionally by the introduction of PACS. We got conclusion as below after analyzing 8 hospitals except the largest and the least amount of examination, film used, developing and fixing solution and the amount of developing and fixing wastewater in order to decrease the deviation from 10 general hospitals located in Seoul and Gyeonggi-Do. We compared data one year before adopting PACS Versus 3 years after adopting PACS. 1. The frequences of examination increased to 7,357.7 cases per month but the amount of film used decreased to 90%, from 42,774.4 to 4,181.88 after adopting the PACS. 2. 3 years after adopting PACS, monthly average amount of developing solution used decreased to 92% and the monthly average amount of fixing solution decreased to 86%. 3. Monthly average amount of developing solution used per film increased to 1.49 times and fixing solution increased as much as three times. 4. Monthly average wastewater for developing decreased to 88% and wastewater for fixing decreased up to 87%. 5. Monthly average wastewater for developing per film increased to 3.77 times and wastewater for fixing increased to 3.85 times. Although the amount of film used and the amount of developing and fixing wastewater affected by the reduction of the developing and fixing solution became less on the whole by introduction of PACS, they did not decrease proportionally. Moreover the amount of the developing and fixing solution used and the amount of developing and fixing wastewater per a film increased. That means the expectation for an environmental improvement differs from the actual condition.

  • PDF