• Title/Summary/Keyword: Radiologic imaging

Search Result 366, Processing Time 0.028 seconds

Plain Abdominal Radiography in Infants and Children (영유아 및 소아의 단순복부 X-선 사진)

  • Lee, Hee-Jung
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.14 no.2
    • /
    • pp.130-136
    • /
    • 2011
  • Plain X-ray radiographs are the first line of investigation taken in the diagnosis of abdominal pathology and are considered an important diagnostic tool to provide guidelines for further imaging studies and comprehensive therapeutic management. Although most abdominal pathology demonstrates non-specific radiologic findings, the plain abdominal radiography is very useful in specific diseases, including certain gastrointestinal anomalies. This review provides image findings of normal plain abdominal radiography and some common abdominal pathology in infants and children.

Synchronous thyroid carcinoma and squamous cell carcinoma. A case report (동시발생한 갑상선 암종과 편평세포암종의 증례보고)

  • Lee, Jae-Seo
    • Imaging Science in Dentistry
    • /
    • v.36 no.4
    • /
    • pp.221-226
    • /
    • 2006
  • Thyroid carcinoma occuring as a second primary associated with head and neck squamous cell carcinoma (SCC) is unusual. This report presents a synchronous thyroid carcinoma and squamous cell carcinoma in the anterior palate region of a 41-year-old man. The clinical, radiologic, and histologic features are described. At 10-month follow-up after operation, no evidence of recurrence and metastasis was present.

  • PDF

The Evaluation of Non-Ionizing Radiation (Near-Infrared Radiation) based Medical Imaging Application : Diabetes Foot (비전리 방사선 (근적외선) 기반 의료영상 활용 가능성 평가: 당뇨발)

  • Jung, Young-Jin;Shin, Cheol-Won;Ahn, Sung-Min;Hong, Jun-Yong;Ahn, Yun-Jin;Lim, Cheong-Hwan
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.399-406
    • /
    • 2016
  • Near-infrared radiation (NIR) is non-ionizing, non-invasive, and deep tissue penetration in biological material, thereby increasing research interests as a medical imaging technique in the world. However, the use of current near-infrared medical image is extremely limited in Korea (ROK) since it is not well known among radiologic technologists and radiological researchers. Therefore to strengthen the knowledge for NIR medical imaging is necessary so as to prepare a qualified radiological professionals to serve medical images in high-quality on the clinical sites. In this study, an overview of the features and principles of NIR imaging was demonstrated. The latest research topics and worldwide research trends were introduced for radiologic technologist to reinforce their technical skills. In particular, wound care and diabetic foot which have high feasibility for clinical translation were introduced in order to contribute to accelerating NIR research for developing the field of radiological science.

Elliptical Centric Techniques and Tricks About the Usefulness of the Clinical Application (Elliptical Centric과 TRICKS 기법의 임상 적용에 관한 유용성 연구)

  • Kim, Sae-Ssak;Goo, Eun-Hoe;Dong, Kyung-Rae;Kweon, Dae-Chel;Lee, Jae-Seung;Cho, Jae-Hwan;Park, Chang-Hee
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.2
    • /
    • pp.83-90
    • /
    • 2011
  • To prospectively determine the diagnostic performance a combination of standard bolus-chase magnetic resonance (MR) angiography and MR angiography with time-resolved imaging of contrast kinetics (TRICKS) for depicting severity of the head and neck vascular diseases. Over a period of two months, A total of 100 patients(average ages : $50{\pm}8$, male : 60, female : 40) with head and neck vascular diseases were performed on the GE excite 3.0 T units with 8-channel head coil and 4-channel NV coil. Imaging parameters for a typical study were as follow: SBC(TR/ TE/ FA/ SliceThicken./ Slab/ Freq./ FOV/ BW/Scan Time) = 5.4/ min/ 30/ 2/ zip2/ 70/ $224{\times}448$/ 30/ 62.50/ 28, TRICKS(TR/ TE/ FA/ Slice Thicken/Slab/ Freq./ FOV/ BW/ Temp Res./ Scan Time = 3.6/ min/ 25/ 4/ 30/ $160{\pm}384$, zip512/ 30/ 100/ 1 to 1.5/ 23). The analysis of all MR images, which have respect-ively classified two techniques into some diseases. The results of the former were divided into two groups(SBC, TRICKS)with 4 grading of two reader, respectively. Wilcoxon signed rank test was used to determine if a significant difference between imaging techniques existed(p < 0.05). In 33 of 100 patients, arterio-venous malformation was 11% at TRICKS, subclavian vein stenosis : 8%, fistular sinus : 4%, jugular vein stenosis:6%, Middle Cerebral Artery bypass surgery : 4%, p < 0.05). The rest of 67 patients were considered as the results of SBC(14% in the basilar artery stenosis, carotid stenosis : 16%, vertebral stenosis : 17%, central neuro-cytoma : 5%, meningioma : 5%, Not appliable : 10%, p < 0.05). Sensitivity and specificity of TRICKS MR angiography in SVS, FS, JVS, MCABS were improved compared with those at standard MR angiography. In SBS MR angiography which were improved in BAS, CS, VS, CN, Meningioma. In conclusion, TRICKS MR angiography of the SVS, FS, JVS, MCABS is superior to standard MR angiography regarding the number of diagnostic grading. The SBS MR angiography were improved in BAS, CS, VS, CN, Meningioma. and assessment of the degree of luminal narrowing on both TRICKS and SBS.

  • PDF

A System Model of Iterative Image Reconstruction for High Sensitivity Collimator in SPECT (SPECT용 고민감도 콜리메이터를 위한 반복적 영상재구성방법의 시스템 모델 개발)

  • Bae, Seung-Bin;Lee, Hak-Jae;Kim, Young-Kwon;Kim, You-Hyun;Lee, Ki-Sung;Joung, Jin-Hun
    • Journal of radiological science and technology
    • /
    • v.33 no.1
    • /
    • pp.31-36
    • /
    • 2010
  • Low energy high resolution (LEHR) collimator is the most widely used collimator in SPECT imaging. LEHR has an advantage in terms of image resolution but has a difficulty in acquiring high sensitivity due to the narrow hole size and long septa height. Throughput in SPECT can be improved by increasing counts per second with the use of high sensitivity collimators. The purpose of this study is to develop a system model in iterative image reconstruction to recover the resolution degradation caused by high sensitivity collimators with bigger hole size. We used fan-beam model instead of parallel-beam model for calculation of detection probabilities to accurately model the high sensitivity collimator with wider holes. In addition the weight factors were calculated and applied onto the probabilities as a function of incident angle of incoming photons and distance from source to the collimator surface. The proposed system model resulted in the equivalent performance with the same counts (i.e. in shortened acquisition time) and improved image quality in the same acquisition time. The proposed method can be effectively applied for resolution improvement of pixel collimator of next generation solid state detectors.

A decision support system the interface between PACS and Laboratory Information (PACS 와 임상검사정보의 연동으로 인한 의사결정시스템; 크레아틴 수치정보전송으로 인한 조영제 부작용 예방)

  • Kim, Sean-Chil;Cho, Hune
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.9 no.1
    • /
    • pp.17-19
    • /
    • 2007
  • This study applies in case of operating an exam using by the contrast order or inputting an order of a contrast media the exam of Radiology Department. It is developed for helping decision making as regards a process of an exam from reading the creatinine value automatically linked with Laboratory Information System. It can be confirmed by real-time information; therefore, the creditability of the information is able to be improved. We will create the base for Patient Monitoring System with the data from the side effect of the creatinine value and allergies. Decision Support System minimize the inconvenience and the riskiness of the given contrast medium for CT tests. We would like to improve medical services by providing a standard circumstance where patients are able to run tests safely and comfortably.

  • PDF

Introduction and Application for Cardiocerebralvascular Center (심뇌혈관 센터를 위한 Cardiac PACS의 도입과 적용 사례)

  • Kim, Jung-Su;Cho, Moo-Seong
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.1
    • /
    • pp.9-14
    • /
    • 2010
  • Based on the cardiac PACS application collected from three university hospitals across the country, this research showed us a composition method of a server and storage devices with conditions in the field. Also, we founded the practical use of software making the best of cardiovascular PACS features. In addition, it also examined the components and requirements of the key functions that are available in the cardiovascular sector. We will be investigated the design experience and applications on stable storage and transmission of large video clip data, cardiovascular analysis, and gear interlocks through the study.

  • PDF

Comparison on the Performance Medical Radiation Shielding Made of Rubber Sheet (의료방사선 차폐 고무시트의 제작과 성능 비교)

  • Kim, Seon-Chil
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.1
    • /
    • pp.15-18
    • /
    • 2010
  • Main component of radiography barrier aprons is lead. To manufacture a lead-free barrier sheath, barium sulfate and organic iodine-based chemicals should be mixed with rubber. Barrier capacity was tested in the medical field. To improve adaptation of rubber with the mixture, raw materials went through milling, agitation, and extruding processes. Three sheaths were manufactured with 30%, 80%, and 120% sulfate barium, respectively. This study found 10% lower barrier capacity of lead-free barrier than the traditional lead-containing rubber sheath. Problems, however, were confronted during the agitation and extruding processes. Mixing with rubber was a technically demanding job. Inconsistent depth, problems with thermal processing and dissipation were encountered as well.

  • PDF

Radiologic Diagnosis of Temporomandibular Joint (측두하악관절의 영상진단)

  • Park, Hyok;Chung, A-Young;Jung, Da-Woon;Kim, Seong-Taek
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.3
    • /
    • pp.291-299
    • /
    • 2012
  • There are many kinds of techniques for imaging temporomandibular joints. None of them for imaging "best fit" for every patient of temporomandibular disorder is recommended ideally. It is more important to be able to select the modality that is most adequate and appropriate for a given clinical issue.

Periductal Stromal Sarcoma of the Breast: a Case Report

  • Kim, Yoon Ha;Lee, Jee Young;Kim, You Me
    • Investigative Magnetic Resonance Imaging
    • /
    • v.21 no.4
    • /
    • pp.269-272
    • /
    • 2017
  • Periductal stromal sarcoma (PSS) is a type of rare malignant fibroepithelial tumor. PSS is a recently introduced diagnostic entity and there are few reports about radiological features of this tumor. Pre-operative diagnosis is difficult because it reveals similar symptoms with other benign and malignant tumors with absence of specific radiologic findings. We present a woman age 30 that underwent mammotome biopsy for a BI-RADS 4 lesion on her left breast and received histopathology diagnosis of a phyllodes tumor. Additionally, she underwent a wide excision depending on her histopathology diagnosis. Her final diagnosis was PSS. Six months later, no recurrence was detected. However, frequent follow-up is needed because PSS can develop into phyllodes tumor or entity of breast cancer.