• Title/Summary/Keyword: Radiologic bone density

Search Result 38, Processing Time 0.031 seconds

Osteopetrosis Tards (만발형골화석증)

  • Kim Young-Hee;Yi Jae-Seo;Yoon Suk-Ja;Kang Byung-Cheol
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.2
    • /
    • pp.507-521
    • /
    • 1999
  • Osteopetrosis is an uncommon hereditary bone disorder whose prominent radiologic feature characterized by increased bone density. The authors reported a 7-year-old male patient who referred from local dental clinic for dental problems such as early exfoliation of deciduous teeth(#54,73,83) and delayed eruption of permanent teeth(#31.41.36.46). The patient appeared as a poorly developed. Dental X-ray films showed early exfoliation of deciduous teeth, delayed eruption of permanent teeth, and rampant caries. Lateral view of skull demonstrated increased opacity of calvarium, facial bones, and skull base. Generally the skeletal density is greatly increased throughout all bones. Facial CT showed poor development of paranasal sinuses and mastoid air cells. No hematopoietic and neurologic complications such as anemia, thrombocytopenia, blindness and deafness were found. Also mental retardation was not found. The final diagnosis of this case was a osteopetrosis tarda. Sometimes patient with osteopetrosis tarda may be developed dental problems prior to severe systemic symptoms. The dentist can be the first clinician to see the patient. It is very important for the dentist to have the knowledge of the osteopetrosis and to care the patient's dental problems to prevent complication such as osteomyelitis of jaws.

  • PDF

CT Observation of Alloplastic Materials Used in Blow Out Fracture (안와골절 정복술에 사용된 인공삽입물의 전산화단층촬영 추적관찰)

  • Lee, Won;Kang, Dong-Hee
    • Archives of Plastic Surgery
    • /
    • v.37 no.4
    • /
    • pp.380-384
    • /
    • 2010
  • Purpose: Distinguishing different types of implants and assessing the position and size of implants by radiologic exam after orbital wall reconstruction is important in determining the surgery outcome and forecasting prognosis. We observed time-dependent density changes in three types of implants (porous polyethylene, resorbing plate and titanium mesh plate) by performing facial bone CT after orbital wall reconstructions. Methods: A total of 32 patients, who had underwent orbital wall fracture surgery from October 2006 to March 2009 and received facial bone CT as outpatients at 1 postoperative year were included in the study. Follow-up facial bone CT was performed on the patients pre- operatively, 1 month post-operatively, and 1 year post-operatively to observe the status of the orbital implants. Medpor $^{(R)}$ (Porex Surgical, Inc., Newnan, Ga.) was used as porous polyethylene and followed-up in 14 cases; for resorbing plate, Synthes mesh plate (Synthes, Oberdorf, Switzerland) was used in the reconstruction, and followed-up in 11 cases; and titanium mesh plate usage was followed-up in 7 cases. Computed tomographic scan (CT) and water's view were done for radiography, and hounsfield unit (HU) was used to compare density of those facial bone CT. Wilcoxon signed rank test was applied to statistically verify measurement difference in each group of hounsfield units. Results: Facial bone CT examination performed in 1 month post-operative showed that the density of porous polyethylene, resorbing plate and titanium mesh plate were -42.07, 105.67 and 539.48 on average, respectively. Among the three types of implants, titanium mesh plate showed the highest density due to its radiopaque feature. Following up the density of three types of implants in CT during 1 year after the orbital wall fracture surgery, the density of porous polyethylene increased in 10.52 House Field Units and the resorbing plate was decreased in 26.87 HouseField Units. There were no significant differences between densities in 1 month post-operatively and 1 year post-operatively in each group ($p{\geq}0.05$). Conclusion: We performed facial bone CT on patients with orbital fractures during follow-up period, distinguishing the types of implants by the different concentration of implant density, and the densities showed little change even at 1 year post-operative. To observe how implant densities change in facial bone CT, further studies with longer follow-up periods should be carried out.

Cross-Calibration of Domestic Devices and GE Lunar Prodigy Advance Dual-Energy X-Ray Densitometer Devices for Bone Mineral Measurements (국산 이중에너지 방사선흡수 골밀도 장치와 GE Lunar Prodigy의 교차분석 식 도출에 관한 연구)

  • Kim, Jung-Su;Rho, Young-Hoon;Lee, In-Ju;Kim, Kyoung-Ah;Lee, In-Ja;Kim, Jung-Min
    • Journal of Radiation Industry
    • /
    • v.11 no.1
    • /
    • pp.27-31
    • /
    • 2017
  • Reliable follow-up of bone mineral density (BMD) by dual energy X-ray absorptiometry (DXA) is essential in clinical practice. When there is a difference in the BMD values from DXA systems in the same patient, cross calibration equation is required for the reliable follow-up. Unfortunately, no equation is existed in BMD measure between GE Lunar Prodigy Advance (US, GE Healthcare; LPA) and Osteosys Dexxum T (Korea, Osteosys; ODT) DXA systems. In this study, we evaluate the agreement of BMD values between LPA and ODT and suggest the cross calibration equation using European spine phantom (ESP) with two systems. We performed BMD measurements using ten scans with ESP in each DXA systems. We compared BMD values and calculated cross calibration equation by linear regression analysis. The comparison between the LPA and ODT bone densitometers used the ESP. Compared to the ESP BMD values, ODT underestimated 14.36% and LPA overestimated 12.96%. The average of total BMD measurement values acquired with ODT were 21.44% lower than those from LPA. Cross-calibration equation for LPA and ODT was derived from ESP. We calculated simple cross calibration equation for LPA and ODT DXA systems. Cross-calibration equation is necessary for the reliable follow-up of BMD values in two different systems.

Craniometaphyseal dysplasia: Report of 2 cases with an emphasis on panoramic imaging features

  • Yeom, Han-Gyeol
    • Imaging Science in Dentistry
    • /
    • v.48 no.4
    • /
    • pp.283-287
    • /
    • 2018
  • Craniometaphyseal dysplasia (CMD) is a rare hereditary disorder characterized by hyperostosis of the craniofacial bones and flared metaphyses of the long bones. Although some reports have described the dentomaxillofacial characteristics of CMD, including increased density of the jaw, malocclusion, and delayed eruption of the permanent teeth, only a few studies have reported the distinct imaging features of CMD on panoramic radiography. This report presents 2 cases of confirmed CMD patients with an emphasis on panoramic imaging features. The patients' images revealed hyperostosis and sclerosis of the maxilla and mandibular alveolar bone, but there was no change in the mandibular basal bone. In both cases, the mandibular condyle heads exhibited a short clubbed shape with hyperplasia of the coronoid process. For patients without clear otorhinolaryngological symptoms, common radiologic features of CMD could be visualized by routinely-taken panoramic radiographs, and further medical examinations and treatment can be recommended.

Insufficiency Fracture of Proximal Tibia in a Young Male Patient with Osteoporosis (젊은 남성 골다공증 환자에서 발생한 경골의 부전 골절)

  • An, Min-Ji;Im, Nam-Gyu;Yoon, Seo-Ra;Ryu, Su-Ra
    • Clinical Pain
    • /
    • v.19 no.2
    • /
    • pp.111-115
    • /
    • 2020
  • We report a case of a healthy 38-year-old man presenting with insufficiency fracture of proximal tibia associated with unrecognized osteoporosis. Radiologic bone DEXA (Dual Energy X-ray Absorptiometry) assessment revealed osteoporosis, but the patient displayed no apparent risk factors for insufficiency fractures and osteoporosis except for a history of smoking. Following right proximal tibial open reduction and internal fixation, the patient commenced smoking cessation and began taking alendronate. The patient was treated for gait rehabilitation, which included quadriceps strengthening exercises and his condition improved with independent walking. This report highlights an unusual site of proximal tibial insufficiency fractures and the potential effect of smoking on low bone mineral density in a young male patient.

Radiographic Bone Density Around Immediately Placed Titanium Implant on the Extraction Socket of Diabetic and Insulin-Treated Rat Maxilla (당뇨쥐 상악에서 발치후 즉시 식립 임플란트 주위골의 방사선 골밀도)

  • Park, Kun-Hyun;Park, Su-Hyun;Lee, Sung-Hwy;Pyo, Sung-Woon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.32 no.5
    • /
    • pp.389-395
    • /
    • 2010
  • Purpose: Although it is generally accepted that patients with controlled diabetes have similar rates of success for dental implants as healthy individuals, the use of dental implants in diabetic patients is controversial. In addition, the impact of diabetes on the healing of bone associated with immediately place dental implants is not completely understood. The purpose of this study was to measure bone response to implants radiologically in uncontrolled and insulin-controlled diabetic rats. Materials and Methods: Twenty rats were divided into control, insulin-treated and diabetic groups. The rats received streptozotocin (60 mg/kg) to induce diabetes; animals in the insulin-treated group also received three units of subcutaneous slow-release insulin. Two titanium implants ($1.2{\times}3$ mm) were placed in the extraction socket of the maxillary first molars of the animals and were harvested at 3 days, 1, 2 and 4 weeks. The bone density was measured by digital radiography using gray-level analysis (histogram) in the regions of interest (ROI) at four points: two mesial and two distal to both sides of the implant. Results: The results showed that the osseointegration of the implants was impaired in the diabetic rats compared to the control and the insulin-treated rats. The radiographic evidence demonstrated marked destruction of bone around the implants in the diabetic group. Both the control and the insulin-treated groups had a significantly higher bone density on radiograph than the diabetic group from the 1 week of the experiment (P<0.05 for each comparison). Conclusion: The present study revealed that the immediate placement of titanium implants in the maxilla of diabetic rat lead to delay in the maturation of bone adjacent to implants. It is expected that the reduced predictability of success of immediate implantation in patient with the uncontrolled diabetes.

The Relationship between the Compression Grade of Vertebrae and Outcome after Percutaneous Vertebroplasty in Patients with Osteoporotic Vertebral Compression Fractures

  • Kim, Jung-Min;Lee, Jong-Won;Hur, Jin-Woo;Kim, Seung-Hyun;Lee, Hyun-Koo;Kim, Myoung-Soo
    • Journal of Korean Neurosurgical Society
    • /
    • v.38 no.5
    • /
    • pp.350-354
    • /
    • 2005
  • Objective : The aim of this study is to assess the immediate and long-term efficacy of percutaneous vertebroplasty for treating painful vertebral osteoporotic fractures. Methods : A retrospective review of 149patients who had undergone 167 vertebroplasty procedures for osteoporotic fractures was performed. Clinical, radiologic, and procedural datas were analyzed as parameters of prognostic significance, including age, sex, bone marrow density score, symptom duration, bone cement filling grade, number of fractured vertebrae, compression grade of vertebrae, leakage of bone cement, volume of bone cement injected and complications. Results : In 158 of the 167 procedures assessed, immediate pain relief was obtained [94.6%]. The extent of collapse of the vertebral body was assessed as a parameter for prognostic significance [p=0.015]. Three months postoperatively, no improvement of the pain was observed in four of the 167 procedures that had undergone the vertebroplasty [2%]. At long-term follow-up, the improvement of pain was not correlated with the compression grade of vertebrae [p=0.420]. Conclusion : The immediate outcome of vertebroplasty are less effective in vertebrae more collapsed.

Analysis of Bone Mineral Density according to Hemoglobin in University Students (혈색소 농도에 따른 대학생의 골밀도 분석)

  • Yoon, Joon;Kim, Dai-Joong;Sung, Hyun-Ho;Jo, Yoon-Kyung
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.48 no.4
    • /
    • pp.296-303
    • /
    • 2016
  • This study was performed to evaluate the effect of hemoglobin (Hb) on bone mineral density (BMD) in university students by performing a quantitative analysis. The subjects included healthy university students aged 20 to 30 years. Although osteoporosis has traditionally been considered as a disease of aging women, it is becoming an increasingly concerning male health problem. Diagnosis of osteoporosis is calculated with a quantitative assessment of BMD. Laboratory blood and urine tests are mainly used with low BMD or fragility fractures to identify any possible causes of bone metabolism disorders. In this study, there was no difference in BMD according to gender. The average red blood cell (RBC), Hb, and Hematocrit (HCT) were significantly higher in males (p<0.01). The correlation between lumbar spine, skeletal muscle mass (SMM), and basal metabolic rate (BMR) was statistically significant (p<0.01). Hb showed a 51.7% statistical influence on BMD by multiple regression analysis. These findings are useful to understand the relationship between BMD and Hb; lower Hb level is associated with lower BMD. The Hb level was the strongest predictor of abnormal BMD. In conclusion, this study showed that a low Hb value was significantly correlated with low bone mass, suggesting that a low Hb value is a risk factor for changes in bone turnover that leads to a decrease bone density.

Diagnostic Coincidence of Radiologic Measurement Methods of the Proximal Femur Anterior-posterior Projection for Assessment of Osteoporosis (근위대퇴부 정면 영상을 이용한 골다공증 평가 시 방사선적 계측의 진단일치도)

  • Kang, Yeong-Han;Cho, Kwang-Ho
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.6
    • /
    • pp.353-360
    • /
    • 2012
  • The purpose of this study was to determine whether there are relationships between radiologic parameters for osteoporosis by the proximal femur radiograhps and bone mineral density, as assessed by Dual Energy X-ray Absorptiometry(DEXA). Proximal femur anterior-posterior projection were taken from 112 individuals who undergoing DEXA. Radiographic parameters including canal-to-calcar ratio(CCR) and cortical thickness indices(CTI) were measured and compared with bone mineral density($g/cm^2$), T-score. The intramedullary femoral canal width(FW) and calcar width(CW) at osteoporosis group was significantly larger than that of control group. The CCR were correlated negatively with bone mineral density($g/cm^2$)(r=-0.340, p<0.01), and the CTI were correlated positively(r=0.624). The diagnostic accuracy of CCR for osteoporosis was 63.4%, and kappa value was 0.271. And the accuracy of CTI was 67.0%, and kappa value was the level of fair agreement(${\kappa}$=0.258). The proximal femur with large CCR and small CTI had lower T-scores. When evaluating proximal femur anterior-posterior radiographs, those patients with the thinnest femur diaphyseal cortices should be referred for further osteoporosis investigation.

TUMOR-INDUCED HYPOPHOSPHATEMIC OSTEOMALACIA -Report of a Case Associated with Peripheral Giant Cell GRANULOMA of Gingiva -

  • Lee Sang Rae;Kim Won Chul;Lee Sang Hoon;Kim Mee Kyung;Lee Byung Do
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.17 no.1
    • /
    • pp.279-286
    • /
    • 1987
  • The authors observed a patient who referred to the Department of Oral Radiology, due to diffuse skeletal pain, muscular weakness and unknown tumor mass on the buccal gingiva of upper right molar region. The patient was found to have peripheral reparative giant cell granuloma and osteomalacia. After removal of the tumor, the clinical, radiologic, and laboratory findings of the patient was rapidly normalized with remarkable improvement of bone pain. The results were as follows: 1. After removal of the tumor, the patient improved. the clinical findings such as bone pain, trismus. muscular weakness and he could walk. 2. In postoperative x-ray findings at 1 and 2 months intervals, the lamina dura of all dentition and bony trabeculae in upper and lower arches were regenerating and the bone density increased. 3. In periodic recall check, no occurrence of osteomalacia was existed and the laboratory findings of the patient showed gradual improvement.

  • PDF