• Title/Summary/Keyword: Radioisotopes

Search Result 190, Processing Time 0.028 seconds

Pattern Analysis of $^{67}Gallium$ Scintigraphy in Sarcoidosis (유육종증의 $^{67}Gallium$ 스캔 유형 분석)

  • Kang, Yun-Hee;Lim, Seok-Tae;Moon, Eun-Ha;Kim, Dong-Wook;Jeong, Hwan-Jeong;Sohn, Myung-Hee
    • Tuberculosis and Respiratory Diseases
    • /
    • v.70 no.6
    • /
    • pp.504-510
    • /
    • 2011
  • Background: $^{67}Ga$ scintigraphy has been used for years in sarcoidosis for diagnosis and to determine the extent of the disease. The present report is a study of various findings of $^{67}Ga$ scintigraphy in patients with sarcoidosis. Methods: Between 1998 and 2007, 16 patients (male:female, 6:10; age, $35.9{\pm}15.3$ years) with histologically proven sarcoidosis underwent clinical evaluation and $^{67}Ga$ scintigraphy. According to the site of involvement, they were divided into subtypes and analyzed. Results: Sixteen patients with sarcoidosis had involvement of various organs, including lymph nodes (13/16, 81.3%), lung (3/16, 18.8%), muscle (1/16, 6.3%), subcutaneous tissue (1/16, 6.3%), glands (1/16, 6.3%), and bone (1/16, 6.3%). Sites of involved lymph nodes were thorax (12/13, 92.3%), supraclavicular area (5/13, 38.5%), inguinal area (2/13, 15.4%), abdomen (2/13, 15.4%), and pelvis (1/13, 7.7%). Conclusion: Because sarcoidosis frequently involves multiple organs, $^{67}Ga$ scintigraphy is a useful method in for evaluating the whole body. Nuclear medicine physicians should be familiar with the various findings of gallium uptake in sarcoidosis.

Optimization of Acquisition Time of Beta-Gamma Coincidence Counting System for Radioxenon Measurement (방사성제논 탐지를 위한 베타-감마 동시 계측시스템의 측정시간 최적화)

  • Byun, Jong-In;Park, Hong-Mo;Choi, Hee-Yeoul;Song, Myeong-Han;Yun, Ju-Yong
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.3
    • /
    • pp.181-186
    • /
    • 2015
  • Measurement of xenon radioisotopes from nuclear fission is a key element for monitoring underground nuclear weapon tests. $^{131m}Xe$, $^{133}Xe$, $^{133}mXe$ and $^{135}Xe$ in the air can be detected via low background systems such as a beta-gamma coincidence counting system. Radioxenon monitoring is performed through air sampling, xenon extraction, measurement and spectrum analysis. The minimum detectable concentration of $^{135}Xe$ can be significantly variable depending on the sampling time, extraction time and data acquisition time due to its short half-life. In order to optimize the acquisition time with respect to certain experimental parameters such as sampling and xenon extraction, theoretical approach and experiment using SAUNA system were performed to determine the time to minimize the minimum detectable concentration, which the results were discussed.

131I-Labeled-Metuximab Plus Transarterial Chemoembolization in Combination Therapy for Unresectable Hepatocellular Carcinoma: Results from a Multicenter Phase IV Clinical Study

  • Ma, Jun;Wang, Jian-Hua
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.17
    • /
    • pp.7441-7447
    • /
    • 2015
  • Objective: This study evaluated the safety and objective response of combining $^{131}I$-labeled-metuximab (Licartin) with transarterial chemoembolization (TACE) in the treatment of unresectable hepatocellular carcinoma (HCC). Materials and Methods: In a multicenter open-label clinical trial, 341 enrolled patients with stage III/IV HCC according to TNM criteria were nonrandomly assigned to a trial group (n=167) and a control group (n=174), undergoing TACE following hepatic intra-arterial injection of licartin or TACE alone from July 2007 to July 2009. Radiopharmaceutical distribution was evaluated. The primary endpoint was overall survival; secondary endpoints included time-to-progression (TTP), toxicity and adverse events (AEs). Results: The radiobiological distribution demonstrated better localization of licartin in liver tumors than other tissues (P<0.01). The organ absorbed doses to liver and red marrow were $3.19{\pm}1.01Gy$ and $0.55{\pm}0.22Gy$, respectively. The 1-year survival rate was significantly higher [79.47% vs. 65.59%, hazard ratio (HR), 0.598, P=0.041] and TTP significantly improved ($6.82{\pm}1.28$ vs. $4.7{\pm}1.14months$, P=0.037) compared with the control group. Patients at stage III achieved more benefit of one year survival than stage IV in the trial group (86.9% vs. 53.8%, P<0.001). There were significant different toxicities in leukocytopenia, thrombocytopenia and increased total bilirubin level [P<0.001, P=0.013, P<0.01, relative risk (RR) 1.63, 1.33, 1.43], but no differences in severe AEs of upper GI hemorrhage and severe liver dysfunction between the groups (5.39% vs. 2.3%, P=0.136). Conclusions: Owing to excellent tumor-targeting, promised efficacy and favourable toxicity profile, the novel combination therapy of licartin and TACE could be applied in patients with unresectable HCC.

A Study of Liver Scan using $^{113m}In$ Colloid ($^{113m}In$ 교질(膠質)에 의(依)한 간주사(肝走査)에 관(關)한 연구(硏究))

  • Koh, Chang-Soon;Rhee, Chong-Heon;Chang, Ko-Chang;Hong, Chang-Gi D.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.3 no.1
    • /
    • pp.83-99
    • /
    • 1969
  • There have been reported numberous cases of liver scanning in use of $^{198}Au$ colloid by many investigators, however, one in use of $^{113m}In$ colloid has not been reported as yet in this country. The dose of $^{113m}In$ for high diagnostic value in examination of each organ was determined and the dignostic interpretability of liver scanning with the use of $^{113m}In$ was carefully evaluated in comparison with the results of the liver scanning by the conventionally applied radioisotopes. The comparative study of both figures of liver scannings with the use of $^{113m}In$ colloid and $^{198}Au$ colloid delivered following results: 1. The liver uptake rate and clearance into peripheral blood were accentuated more in case of $^{113m}In$ colloid than in case of $^{198}Au$ colloid. 2. The interpretability of space occupying lesion in liver scanning with $^{113m}In$ was also superior to one with $^{198}Au$. 3. The figure of liver scanning with $^{113m}In$ colloid corresponds not always to the figure with $^{198}Au$. This difference can be explained by differences of phagocytic ability of reticuloendotherial system within liver. 4. In the liver scanning with $^{113m}In$ colloid, the spleen is also visualized even in normal examinee. 5. In the cases of disturbed liver function, uptake is more decreased in use of $^{113m}In$ colloid than in $^{198}Au$, in the spleen, however, the way is contrary. 6. With use of $^{113m}In$ colloid, the time required for scanning could be shortened in comparison with $^{198}Au$. 7. The filtration of $^{113m}In$ colloid for scanning prior to human administration gives an expectation for better scanning figure.

  • PDF

Studies on the effect of silicate on nutrients up take using radioisotopes in rice plant. (I) (RI를 이용한 규소시용이 수도의 영양필요흡수에 미치는 영향(I))

  • Choon-Johong Ro
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.12
    • /
    • pp.15-20
    • /
    • 1972
  • There are still many problems on the physiological role of silicon in rice plants, although, it has been reported that silicate slag is the most effective fertilizer for the improvement of Akiochi soils. This experiment is carried out to investigate the effect of silicate of the mineral nutrition uptake by rice plants, using Ca45, P32, C136, and Mn54. The obtained results are summerized as follows; 1. Contents of mineral nutrients except silicon were higher in the rice plant grown in minus Si-culture solution a than in plus Si-plot. 2. Transpiration amounts appeared to be greater in the low content plant of silicon. 3. The rate of translocation to shoot of each ion absorbed by roots depended on the rate of transpiration. 4. It seemed that only CI uptake was found small in minus Si-root. 5. Silicate fetilizer did not affect the solubility of mineral ions in soils.

  • PDF

Organ Dose Assessment of Nuclear Medicine Practitioners Using L-Block Shielding Device for Handling Diagnostic Radioisotopes (진단용 방사성동위원소 취급 시 L-block 차폐기구 사용에 따른 핵의학 종사자의 장기 선량평가)

  • Kang, Se-Sik;Cho, Yong-In;Kim, Jung-Hoon
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.49-55
    • /
    • 2017
  • In the case of nuclear medicine practitioners in medical institutions, a wide range of exposure dose to individual workers can be found, depending on the type of source, the amount of radioactivity, and the use of shielding devices in handling radioactive isotopes. In this regard, this study evaluated the organ dose on practitioners as well as the dose reduction effect of the L-block shielding device in handling the diagnostic radiation source through the simulation based on the Monte Carlo method. As a result, the distribution of organ dose was found to be higher as the position of the radiation source was closer to the handling position of a practitioner, and the effective dose distribution was different according to the ICRP tissue weight. Furthermore, the dose reduction effect according to the L-block thickness tended to decrease, which showed the exponential distribution, as the shielding thickness increased. The dose reduction effect according to each radiation source showed a low shielding effect in proportion to the emitted gamma ray energy level.

Preparation of Fibrous Adsorbent Modified with Iminodiacetic Acid and Its Co2+, Fe2+, and Pb2+ Adsorption Characteristics (이미노디아세트산을 함유한 섬유상 흡착제 제조 및 코발트, 철, 납 이온 흡착특성)

  • Yang, Hyun-Soo;Choi, Jun-Kyu;Nho, Young Chang
    • Applied Chemistry for Engineering
    • /
    • v.10 no.3
    • /
    • pp.477-485
    • /
    • 1999
  • The grafting of 2,3-epoxypropylmethacrylate (GMA) onto polypropylene fabric was carried out by the $\gamma$-ray preirradiation grafting technique. Subsequently, the GMA-grafted polypropylene fabric was reacted with iminodiacetic acid (IDA) in different mixed solvents to prepare the fibrous metal adsorbent. The grafting extent was found to be dependent on the reaction time, temperature, preirradiation dose and dose rate. The effects of various mixed solvents on the IDA amination onto GMA-grafted polypropylene fabric were investigated. Compared with other mixed solvents, the extent of amination was highest in the dimethylsulfoxide (DMSO)/water, but the reaction did not occur in the water. The adsorption characteristics of various metal ions by the prepared adsorbent were examined when it was immersed in the 100 ppm metal ion solution. The amount of adsorption followed the order:$Pb^{2+}>Co^{2+}>Fe^{2+}$.

  • PDF

Radiation-Induced Grafting of Acrylic Acid onto Cellulose : I. Graft Polymerization of Acrylic Acid onto Radiation-Peroxidized Cellulose (셀롤로오스에 아크릴산의 방사선 그라프트 반응: I. 과산화물에 의한 그라프트반응)

  • Kwon, Oh Hyun;Nho, Young Chang;Yang, Hyun Soo
    • Applied Chemistry for Engineering
    • /
    • v.8 no.6
    • /
    • pp.934-938
    • /
    • 1997
  • Acrylic acid was grafted onto the peroxidized cellulose which was stored at room temperature for 20 days after ${\gamma}$-ray irradiation in air. The effect of acids and metallic salts on the grafting yields was determined. The addition of both the acid and metallic salt was found to accelerate the grafting yield much more than the only metallic salt, and the addition of $FeSO_4{\cdot}7H_2O$ led to much higher grafting yield than that of $CuSO_4{\cdot}5H_2O$. The effect of acid on the grafting yield increased by the order $H_2>SO_4>HCl>HNO_3>CH_3COOH$. With the addition of $H_2SO_4$, the grafting yield rapidly increased up to $7{\times}10^{-2}$M, and then levelled off.

  • PDF

Radiation-Induced Grafting of Acrylic Acid onto Cellulose: III. The Water Absorption Characteristics (셀룰로오스에 아크릴산의 방사선 그라프트 반응: III. 셀룰로오스의 흡수특성)

  • Kwon, Oh Hyun;Nho, Young Chang
    • Applied Chemistry for Engineering
    • /
    • v.9 no.4
    • /
    • pp.516-522
    • /
    • 1998
  • In this study, a water adsorbent was synthesized by radiation grafting of acrylic acid and multifunctional monomers such as 1,2-propanediol dimethacrylate (PDMA) and 1,1,1-trimethylolethane triacrylate (TMETA) onto cellulose and its subsequent treatment with 5% NaOH. Its absorbency on $H_2O$ and 0.9 % NaCl aqueous solution was examined. The highest absorbency on water and on 0.9% NaCl aqueous solution was obtained from the addition of 0.75 vol % PDDMA and of 1.0 vol % TMETA onto acrylic acid solution, respectively. The absorbency of commercial hygienic band on water and NaCl aqueous solution was 21 g/g and 22 g/g, respectively. However, that for acrylic acid-grafted cellulose including TMETA was 298 g/g and 54 g/g, respectively.

  • PDF

Safety Evaluation of a Radioisotope Transport Package (방사성 동위원소 운반용기의 안전성 평가)

  • Lee, J.C.;Ku, J.H.;Seo, K.S.;Min, D.K.
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.4
    • /
    • pp.251-261
    • /
    • 1997
  • A package to transport the high level radioactive materials is required to withstand the hypothetical accident conditions as well as normal transport conditions according to IAEA standards and domestic regulations. The regulations require that the package should maintain the shielding, thermal and structural integrities to release no radioactive material. In general, safety evaluation of packages is performed by experimental methods using scale model and/or analytical methods using computer codes. This paper presents the safety evaluation of package to transport the radioisotopes produced in the HANARO to the radioisotope production facility. Radiation shielding, thermal and structural analyses were peformed using the computer codes. It has been verified that the package is safe under hypothetical accident conditions as well as normal transport conditions.

  • PDF