• Title/Summary/Keyword: Radiography, Panoramic

Search Result 293, Processing Time 0.028 seconds

Comparison of panoramic radiography and cone-beam computed tomography for assessing radiographic signs indicating root protrusion into the maxillary sinus

  • Jung, Yun-Hoa;Cho, Bong-Hae;Hwang, Jae Joon
    • Imaging Science in Dentistry
    • /
    • v.50 no.4
    • /
    • pp.309-318
    • /
    • 2020
  • Purpose: This study investigated correlations between findings on panoramic radiographs and cone-beam computed tomography (CBCT) to assess the relationship between the maxillary sinus floor and the roots of maxillary posterior teeth. In addition, radiographic signs indicating actual root protrusion into the maxillary sinus were evaluated on panoramic radiographs. Materials and Methods: Paired panoramic radiographs and CBCT images from 305 subjects were analyzed. This analysis classified 2,440 maxillary premolars and molars according to their relationship with the maxillary sinus floor on panoramic radiographs and CBCT images. In addition, interruption of the sinus floor was examined on panoramic radiographs. Results: Root protrusion into the maxillary sinus occurred most frequently in the mesiobuccal roots of the second molars. The classification according to panoramic radiographs and CBCT images was the same in more than 90% of cases when there was no contact between the root apex and the sinus floor. When the panoramic radiograph showed root protrusion into the sinus, the CBCT images showed the same classification in 67.5% of second molars, 48.8% of first molars, and 53.3% of second premolars. There was a statistically significant relationship between interruption of the sinus floor on panoramic radiographs and root protrusion into the sinus on CBCT images. Conclusion: The presence of root protrusion into the sinus on panoramic radiographs demonstrated a moderate ability to predict root protrusion into the maxillary sinus. Interruption of the maxillary sinus floor could be considered an indicator of actual root protrusion into the maxillary sinus.

Clinical and panoramic radiographic features of osteomyelitis of the jaw: A comparison between antiresorptive medication-related and medication-unrelated conditions

  • Shin, Jeong Won;Kim, Jo-Eun;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.49 no.4
    • /
    • pp.287-294
    • /
    • 2019
  • Purpose: This study was performed to analyze the clinical and imaging features of contemporary osteomyelitis(OM) and to investigate differences in these features on panoramic radiography according to patients' history of use of medication affecting bone metabolism. Materials and Methods: The records of 364 patients(241 female and 123 male, average age 66.8±14.9 years) with OM were retrospectively reviewed. Panoramic imaging features were analyzed and compared between patients with medication-related OM(m-OM) and those with conventional, medication-unrelated OM(c-OM). Results: The age of onset of OM tended to be high, with the largest number of patients experiencing onset in their 70s. The 2 most frequent presumed causes were antiresorptive medication use (44.2%) and odontogenic origin (34.6%). On panoramic radiographs, a mix of osteolysis and sclerosis was the most common lesion pattern observed (68.6%). Sequestrum, extraction socket, and periosteal new bone formation were found in 143(42.1%), 79 (23.2%), and 24 (7.1%) cases, respectively. The m-OM group exhibited sequestrum and extraction socket more frequently and displayed significantly higher mandibular cortical index values than the c-OM group. Conclusion: We observed some differences in imaging features as shown on panoramic radiography according to the history of antiresorptive medication use. This study may help elucidate the predictive imaging features of medication-related osteonecrosis of the jaw.

Comparative Study of the Effective Dose from Panoramic Radiography in Dentistry Measured Using a Radiophotoluminescent Glass Dosimeter and an Optically Stimulated Luminescence Detector

  • Lee, Kyeong Hee;Kim, Myeong Seong;Kweon, Dae Cheol;Choi, Jiwon
    • Journal of the Korean Physical Society
    • /
    • v.73 no.9
    • /
    • pp.1377-1384
    • /
    • 2018
  • Accurate measurement of the absorbed dose and the effective dose is required in dental panoramic radiography involving relatively low energy with a rotational X-ray tube system using long exposures. To determine the effectiveness of measuring the irradiation by using passive dosimetry, we compared the entrance skin doses by using a radiophotoluminescent glass dosimeter (RPL) and an optically stimulated luminescence detector (OSL) in a phantom model consisting of nine and 31 transverse sections. The parameters of the panoramic device were set to 80 kV, 4 mA, and 12 s in the standard program mode. The X-ray spectrum was applied in the same manner as the panoramic dose by using the SpekCalc Software. The results indicated a mass attenuation coefficient of $0.008226cm^2/g$, and an effective energy of 34 keV. The equivalent dose between the RPL and the OSL was calculated based on a product of the absorbed doses. The density of the aluminum attenuators was $2.699g/cm^3$. During the panoramic examination, tissue absorption doses with regard to the RPL were a surface dose of $75.33{\mu}Gy$ and a depth dose of $71.77{\mu}Gy$, those with regard to the OSL were surface dose of $9.2{\mu}Gy$ a depth dose of $70.39{\mu}Gy$ and a mean dose of $74.79{\mu}Gy$. The effective dose based on the International Commission on Radiological Protection Publication 103 tissue weighting factor for the RPL were $0.742{\mu}Sv$, $8.9{\mu}Sv$, $2.96{\mu}Sv$ and those for the OSL were $0.754{\mu}Sv$, $9.05{\mu}Sv$, and $3.018{\mu}Sv$ in the parotid and sublingual glands, orbit, and thyroid gland, respectively. The RPL was more effective than the OSL for measuring the absorbed radiation dose in low-energy systems with a rotational X-ray tube.

Reliability of two different presurgical preparation methods for implant dentistry based on panoramic radiography and cone-beam computed tomography in cadavers

  • Hu, Kyung-Seok;Choi, Da-Yae;Lee, Won-Jae;Kim, Hee-Jin;Jung, Ui-Won;Kim, Sung-Tae
    • Journal of Periodontal and Implant Science
    • /
    • v.42 no.2
    • /
    • pp.39-44
    • /
    • 2012
  • Purpose: Special care is necessary to avoid invading important anatomic structures during surgery when presurgical planning is made based on radiographs. However, none of these types of radiography represents a perfect modality. The purpose of this study was to determine the reliability of presurgical planning based on the use of two types of radiographic image (digital panoramic radiography [DPR] and cone-beam computed tomography [CBCT]) by beginner dentists to place implants, and to quantify differences in measurements between radiographic images and real specimens. Methods: Ten fresh cadavers without posterior teeth were used, and twelve practitioners who had no experience of implant surgery performed implant surgery after 10 hours of basic instruction using conventional surgical guide based on CBCT or DPR. Two types of measurement error were evaluated: 1) the presurgical measurement error, defined as that between the presurgical and postsurgical measurements in each modality of radiographic analysis, and 2) the measurement error between postsurgical radiography and the real specimen. Results: The mean presurgical measurement error was significantly smaller for CBCT than for DPR in the maxillary region, whereas it did not differ significantly between the two imaging modalities in the mandibular region. The mean measurement error between radiography and real specimens was significantly smaller for CBCT than for DPR in the maxillary region, but did not differ significantly in the mandibular region. Conclusions: Presurgical planning can be performed safely using DPR in the mandible; however, presurgical planning using CBCT is recommended in the maxilla when a structure in a buccolingual location needs to be evaluated because this imaging modality supplies buccolingual information that cannot be obtained from DPR.

Development of a new ball-type phantom for evaluation of the image layer of panoramic radiography

  • Yeom, Han-Gyeol;Kim, Jo-Eun;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.48 no.4
    • /
    • pp.255-259
    • /
    • 2018
  • Purpose: This study proposes a new ball-type phantom for evaluation of the image layer of panoramic radiography. Materials and Methods: The arch shape of an acrylic resin phantom was derived from average data on the lower dental arch in Korean adult males. Metal balls with a 2-mm diameter were placed along the center line of the phantom at a 4-mm mesiodistal interval. Additional metal balls were placed along the 22 arch-shaped lines that ran parallel to the center line at 2-mm buccolingual intervals. The height of each ball in the horizontal plane was spaced by 2.5 mm, and consequently, the balls appeared oblique when viewed from the side. The resulting phantom was named the Panorama phantom. The distortion rate of the balls in the acquired image was measured by automatically calculating the difference between the vertical and horizontal length using $MATLAB^{(R)}$. Image layer boundaries were obtained by applying various distortion rate thresholds. Results: Most areas containing metal balls (91.5%) were included in the image layer with a 50% distortion rate threshold. When a 5% distortion rate threshold was applied, the image layer was formed with a small buccolingual width along the arch-shaped center line. However, it was medially located in the temporomandibular joint region. Conclusion: The Panorama phantom could be used to evaluate the image layer of panoramic radiography, including all mesiodistal areas with large buccolingual width.

Comparison of the reproducibility of panoramic radiographs between dentulous and edentulous patients

  • Park, Jong-Woong;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.44 no.2
    • /
    • pp.95-102
    • /
    • 2014
  • Purpose: This study was performed to evaluate the reproducibility of panoramic radiographs of dentulous and edentulous patients. Materials and Methods: The reproducibility of panoramic radiographs was evaluated using the panoramic radiographs acquired from 30 anterior dentulous patients by using a common biting positioning device (dentulous group) and 30 anterior edentulous patients by using chin-support devices to take a panoramic radiograph (edentulous group), respectively; these patients had undergone 3 or more panoramic radiographs. The widths and angles between the designated landmarks were measured on the panoramic radiographs, and the reproducibility was evaluated using the intraclass correlation coefficient (ICC) and the coefficient of variation. Results: In the dentulous and edentulous groups, the ICCs of the mandibular ramus and mandibular angle areas were higher than the condylar head and zygomatic areas. The mandibular ramus and angle areas showed statistically lower mean coefficients of variation than the condylar head and zygomatic areas in the dentulous group. The mandibular angle area showed a significantly lower mean coefficient of variation than the zygomatic area in the edentulous group. By comparing the two groups, each ICC of the edentulous group was lower than that of the dentulous group, and the mean coefficients of variation of the mandibular ramus area, zygomatic area, left condylar inclination, and ramus ratio between the right and the left in the edentulous group were significantly higher than those in the dentulous group. Conclusion: Biting positioning for dentulous patients provided better positioning reproducibility than chin-support positioning when performing panoramic radiography for edentulous patients.

Comparison of the diagnostic performance of panoramic and occlusal radiographs in detecting submandibular sialoliths

  • Kim, Jun Ho;Aoki, Eduardo Massaharu;Cortes, Arthur Rodriguez Gonzalez;Abdala-Junior, Reinaldo;Asaumi, Junichi;Arita, Emiko Saito
    • Imaging Science in Dentistry
    • /
    • v.46 no.2
    • /
    • pp.87-92
    • /
    • 2016
  • Purpose: The aim of this study was to assess and compare the diagnostic performance of panoramic and occlusal radiographs in detecting submandibular sialoliths. Materials and Methods: A total of 40 patients (20 cases and 20 controls) were included in this retrospective study. Cases were defined as subjects with a submandibular sialolith confirmed by computed tomography (CT), whereas controls did not have any submandibular calcifications. Three observers with different expertise levels assessed panoramic and occlusal radiographs of all subjects for the presence of sialoliths. Intraobserver and interobserver agreement were assessed using the kappa test. Sensitivity, specificity, accuracy, positive and negative predictive values, and the diagnostic odds ratio of panoramic and occlusal radiographs in screening for submandibular sialoliths were calculated for each observer. Results: The sensitivity and specificity values for occlusal and panoramic radiographs all ranged from 80% to 100%. The lowest values of sensitivity and specificity observed among the observers were 82.6% and 80%, respectively (P=0.001). Intraobserver and interobserver agreement were higher for occlusal radiographs than for panoramic radiographs, although panoramic radiographs demonstrated a higher overall accuracy. Conclusion: Both panoramic and occlusal radiographic techniques displayed satisfactory diagnostic performance and should be considered before using a CT scan to detect submandibular sialoliths.

Structural complexity of the craniofacial trabecular bone in multiple myeloma assessed by fractal analysis

  • Michels, Mariane;Morais-Faria, Karina;Rivera, Cesar;Brandao, Thais Bianca;Santos-Silva, Alan Roger;Oliveira, Matheus L
    • Imaging Science in Dentistry
    • /
    • v.52 no.1
    • /
    • pp.33-41
    • /
    • 2022
  • Purpose: This study aimed to evaluate the structural complexity of craniofacial trabecular bone in multiple myeloma by fractal analysis of panoramic and lateral skull radiography, and to compare the fractal dimension values of healthy patients (HPs), pre-treatment patients (PTPs), and patients during bisphosphonate treatment (DTPs). Materials and Methods: Pairs of digital panoramic and lateral skull radiographs of 84 PTPs and 72 DTPs were selected. After application of exclusion criteria, 43 panoramic and 84 lateral skull radiographs of PTPs, 56 panoramic and 72 lateral skull radiographs of DTPs, and 99 panoramic radiographs of age- and sex-matched HPs were selected. The fractal dimension values from panoramic radiographs were compared among HPs, PTPs, and DTPs and between anatomical locations within patient groups using analysis of variance with the Tukey test. Fractal dimension values from lateral skull radiographs were compared between PTPs and DTPs using the Student t-test. Pearson correlation coefficients were used to assess the relationship between the mandible from panoramic radiographs and the skull from lateral skull radiographs. Intra-examiner agreement was assessed using intraclass correlation coefficients (α=0.05). Results: The fractal dimension values were not significantly different among HPs, PTPs, and DTPs on panoramic radiographs or between PTPs and DTPs on lateral skull radiographs (P>0.05). The mandibular body presented the highest fractal dimension values (P≤0.05). The fractal dimension values of the mandible and skull in PTPs and DTPs were not correlated. Conclusion: Fractal analysis was not sensitive for distinguishing craniofacial trabecular bone complexity in multiple myeloma patients using panoramic and lateral skull radiography.

A RADIOGRAPHIC STUDY OF THE PANORAMIC INNOMINATE LINE II (파노라마 X선사진상의 무명선에 관한 연구 II)

  • Choi Karp-Shik;Lee Kang-Sook
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.25 no.1
    • /
    • pp.109-114
    • /
    • 1995
  • The purpose of this study was to investigate the changes of the shape of the panoramic innominate line and also to examine the relation of the panoramic innominate line to maxillary posterior wall according to positional changes in panoramic radiographs of the patients who had no pathoses in the maxillary sinus and adjacent bony structures. Thus these panoramic radiographs were obtained and evaluated in standard, forward 10mm, backward 10mm, chin down 10°, and chin up 10° positions. And the following results were obtained : 1. Panoramic innominate lines were not changed in shape according to various positional changes in panoramic radiography. 2. The panoramic innominate line was observed to be more clear images and decreased distance to the posterior wall of maxillary sinus at forward 10mm and chin down 10° positions. And the panoramic innominate line was observed more blurred images and increased distance to the posterior wall of maxillary sinus at backward 10mm and chin up 10° positions.

  • PDF

Is the diagnosis of calcified laryngeal cartilages on panoramic radiographs possible?

  • Cagirankaya, Leyla Berna;Akkaya, Nursel;Akcicek, Gokcen;Dogru, Hatice Boyacioglu
    • Imaging Science in Dentistry
    • /
    • v.48 no.2
    • /
    • pp.121-125
    • /
    • 2018
  • Purpose: Detecting laryngeal cartilages (triticeous and thyroid cartilages) on panoramic radiographs is important because they may be confused with carotid artery calcifications in the bifurcation region, which are a risk factor for stroke. This study assessed the efficiency of panoramic radiography in the diagnosis of calcified laryngeal cartilages using cone-beam computed tomography (CBCT) as the reference standard. Materials and Methods: A total of 312 regions(142 bilateral, 10 left, 18 right) in 170 patients(140 males, 30 females) were examined. Panoramic radiographs were examined by an oral and maxillofacial radiologist with 11 years of experience. CBCT scans were reviewed by 2 other oral and maxillofacial radiologists. The kappa coefficient(${\kappa}$) was calculated to determine the level of intra-observer agreement and to determine the level of agreement between the 2 methods. Diagnostic indicators(sensitivity, specificity, accuracy, and false positive and false negative rates) were also calculated. P values <.05 were considered to indicate statistical significance. Results: Eighty-two images were re-examined to determine the intra-observer agreement level, and the kappa coefficient was calculated as 0.709 (P<.05). Statistically significant and acceptable agreement was found between the panoramic and CBCT images (${\kappa}=0.684$ and P<.05). The sensitivity, specificity, diagnostic accuracy rate, the false positive rate, and the false negative rate of the panoramic radiographs were 85.4%, 83.5%, 84.6%, 16.5%, and 14.6%, respectively. Conclusion: In most cases, calcified laryngeal cartilages could be diagnosed on panoramic radiographs. However, due to variation in the calcifications, diagnosis may be difficult.